• Title/Summary/Keyword: 기준전극

Search Result 255, Processing Time 0.03 seconds

Electrochemical Study of Nanoparticle Li4Ti5O12 as Negative Electrode Material for Lithium Secondary Battery (리튬이차전지 음극재용 나노입자 Li4Ti5O12의 전기화학적 연구)

  • Oh Mi-Hyun;Kim Han-Joo;Kim Young-Jae;Son Won-Keun;Lim Kee-Joe;Park Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.9 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Lithium titanium oxide $(Li_4Ti_5O_{12})$ with spinel-framework structures as anode material for lithium-ion battery was prepared by sol-gel and high energy ball milling (HEBH) method. According to the X-ray diffraction (XRD), Particle Size Analyses(PSA) and scanning electron microscopy (SEM) analysis, uniformly distributed $Li_4Ti_5O_{12}$ particles with grain sizes of 100 nm were observed. Half cells, consisting of $Li_4Ti_5O_{12}$ as working electrode and lithium foil as both counter and reference electrodes showed the high performance of high rate discharge capacity and 173 mAh/g at 0.2C in the range of $1.0\sim2.5 V$. Furthermore, the crystalline structure of $Li_4Ti_5O_{12}$ didn't transform during the lithium intercalation and deintercalation process.

Photocurrent and Its Stability Enhancement of Dye-sensitized Nanoparticle $TiO_2$ Solar Cells (염료감응 나노입자 $TiO_2$ 태양전지의 광전류와 그 안정성 향상)

  • Chae Won-Weok;Kang Tae-Sik;Kim Kang-Jin
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.4
    • /
    • pp.232-236
    • /
    • 1999
  • A solar cell based on dye-sensitized photoelectric conversion was studied by electrochemical and spec-trofluorometric methods for the purposes of enhancing its efficiency and stability of $TiO_2$ solar cells. Nanocrystalline $TiO_2$ was used to prepare photoelectrodes, and photosensitizing dyes such as malachite green oxalate, basic blue3, rhodamine B, and bromocresol purple were chosen as sensitizers. Electrochemical oxidation potentials and absorption and emission wavelengths of dyes were used to determine energy levels of the dyes. By comparing excited energy levels of the dyes with the conduction band edge potential $(E_{c,s})\;of\;TiO_2$ calculated by using the flat-band potential $(E_{fb})\;of\;TiO_2$, properties of a dye required to fabricate a high efficient photosensitizing solar cell with high short-circuit current $(J_{sc})$ were suggested. Enhanced stability of photocurrent was obtained by coating a $TiO_2|ITO$ electrode with Polypyrrole that Possibly Prevented the recombination between the conduction band electrons and oxidized dyes and suppressed the direct electrode redox reactions of dyes on ITO.

A Study on the Electrochemical Properties of Langmuir-Blodgett Film Mixed with Saturated Fatty Acid and Phospholipid(DMPC) (포화지방산과 인지질(DMPC)혼합 Langmuir-Blodgett막의 전기화학적 특성에 관한 연구)

  • Woo, Seong-Hyup;Park, Keun-Ho
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.3
    • /
    • pp.359-366
    • /
    • 2014
  • We investigated an electrochemical properties for Langmuir-Blodgett (LB) films of saturated fatty acid and phospholipid(L-${\alpha}$-dimyristoylphosphatidyl choline, DMPC) mixture. LB films of saturated fatty acid and DMPC monolayer were deposited by the LB method on the indium tin oxide(ITO) glass. The electrochemical properties measured by cyclic voltammetry with three-electrode system(an Ag/AgCl reference electrode, a platinum wire counter electrode and LB film-coated ITO working electrode) in $NaClO_4$ solution. As a result, monolayer LB films of saturated fatty acid and phospholipid mixture was appeared on irreversible process caused by the oxidation current from the cyclic voltammogram. Diffusion coefficient (D) of saturated fatty acid and DMPC mixture(molar ratio 1:1, C12, C14, C16, C18) was calculated $1.2{\times}10^{-3}$, $2.1{\times}10^{-3}$, $1.4{\times}10^{-4}$ and $1.1{\times}10^{-3}cm^2/s$ in 0.05 N $NaClO_4$ solution, respectively.

Optimization of Electrolysis Using Sacrificial Electrode for the Treatment of Electroless Nickel Plating Wastewater (희생전극을 이용한 무전해 니켈 도금 폐수의 전기분해처리 최적화)

  • Kim, Young-Shin;Jeon, Byeong-Han;Cho, Soon-Haing
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.4
    • /
    • pp.204-209
    • /
    • 2015
  • The effluent limit of nickel from electroplating wastewater has been strengthened from 5 mg/L to 3 mg/L from 2014. However, currently applied treatment process for nickel plating wastewater is unable to meet the effluent limit, most of the treatment concept conducted by treatment plant is dilution with other metal bearing wastewater. This can cause very significant impact to the environment of nickel contamination. With this connection, the feasibility test has been conducted with the use of electrolysis by using sacrificial electrodes. Experiments were conducted in synthetic and electroless nickel plating wastewater. Optimal condition of current density, pH were derived from the synthetic wastewater. It was found that the removal efficiency of nickel exceeded 94% at the operation condition of at pH 9 and the current density of $1{\sim}2mA/cm^2$. At this conditions, the iron sludge was generated very low amount. However, it was unsuccessful to meet the effluent limit by applying these treatment conditions to the real electroplating wastewater. This can be explained due to the matrix effect of other metals and anions contained real electroplating wastewater. From the result of further study, the optimal conditions for the real wastewater treatment were found out to be at pH 9, current density $6{\sim}7mA/cm^2$, for 5 minutes of operating time. At these conditions, 88% removal of nickel was achieved, which results the residual nickel concentration was below 3 mg/L.

Characterization of Water-Filled Ag/AgCl Reference Electrode

  • Bahn Chi Bum;Oh Sihyoung;Hwang Il Soon;Chung Hahn Sup;Jegarl Sung
    • Journal of the Korean Electrochemical Society
    • /
    • v.4 no.3
    • /
    • pp.87-93
    • /
    • 2001
  • Pressure-balanced external Ag/AgCl electrode has been extensively used for both Pressurized Water Reactor (PWR) and Boiling Water Reactor (PWR) environments. The use of KCI-based buffer solution often becomes the source of electrode potential drift due to slow leakage through its porous plug, typically made of zirconia. It is reported that results of our effort to improve the stability of electrode potential by using high purity water as the filling solution in which $Cl^-$ ion activity can be established and maintained at the solubility of AgCl even with the sustained leakage for a long period. Stability tests have been made in boron and lithium mixture solution at $288^{\circ}C$. The electrode potential remained stable within 10 mV over one week period. And after a thermal cycle between 288 to $240^{\circ}C$ the potential shift of Ag/AgCl electrodes did not exceed 15 mV By using the limiting equivalent ionic conductances and Agar's hydrodynamic theory, the thermal liquid junction potential (TLJP) of the electrode has been predicted. The calculated values for the water-fiued Ag/AgCl electrode potential, in which the chlorine concentration in the filling solution was derived from the measured data at ambient temperature, had a good agreement with the experimental values.

접지 시스템 계획(마지막회)

  • Lee, Seong-U;Kim, Jin-Gon
    • Electric Engineers Magazine
    • /
    • v.264 no.8
    • /
    • pp.14-21
    • /
    • 2004
  • 접지 시스템의 계획은 접지전극 형상의 설계와 계통접지 방식에 따른 접지 시스템으로 구성하여야 하고 접지 또는 급속체간 전위차가 발생하지 않도록 Bonding 기술을 충분히 고려하여야 한다. 그러나 국내의 기술기준 및 내선규정은 이에 대한 규정이 없으며 단지 접지종별 접지저항 값만을 규정하고 있어 실무에서 많은 이견이 발생하고 있고 전력기술인 협회지 2~4월호에서 살펴보았듯이 자동화 되는 생산 Line에서는 피해가 커지고 있다.<중략>

  • PDF

A Study on the Quality Evaluation Model for Cyber Education Supporting System (가상학습 지원시스템의 품질평가 모델에 관한 연구)

  • 강호영;박만곤
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2000.11a
    • /
    • pp.432-436
    • /
    • 2000
  • 가상학습은 지식 정보화시대를 맞이하여 국내외으로 새로운 교육훈련 패러다임으로서 시간과 공간을 초월한 얼린 학습공간으로 부각되고 있다. 특히 정보처리 기술의 급속한 발전으로 국내외 각종 정규·사회 교육기관에서는 인터넷을 이용한 가상학습 교육훈련을 전극 도입하고 있는 추세이다. 가상학습을 기반으로 하는 코스웨어 개발이냐 학습평가에 관한 연구는 많으나 품질평가에 관한 연구는 아직까지 미비하여 본 논문에서는 가상학습 지원시스템의 품질평가 모델을 제시하여 교육 현장에서 가상학습 지원시스템 구축 시 품질평가 기준으로 활용하고자 한다.

  • PDF

Analysis of Heavy Metals in $[^{201}Tl]$TICI Injection Using Polarography (폴라로그래피를 이용한 $[^{201}Tl]$염화탈륨 주사액의 중금속 분석)

  • Chun, Kwon-Soo;Suh, Yong-Sup;Yang, Seung-Dae;Ahn, Soon-Hyuk;Kim, Sang-Wook;Choi, Kang-Hyuk;Lee, Dong-Hoon;Lim, Sang-Moo;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.336-343
    • /
    • 2000
  • Purpose: Thallous-201 chloride produced at Korea Cancer Center Hospital(KCCH) is used in detecting cardiovascular disease and cancer. Thallium impurity can cause emesis, catharsis and nausea, so the presence of thallium and other metal impurities should be determined. According to USP and KP, their amounts must be less than 2 ppm in thallium and 5 ppm in total. In this study, the detection method of trace amounts of metal impurities in $[^{201}Tl]$TICI injection with polarography was optimized without environmental contamination. Materials and Methods: For the detection of metal impurities, Osteryoung Square Wave Stripping Voltammetry method was used in Bio-Analytical System (BAS) 50W polarograph. The voltammetry was composed of Dropping Mercury Electrode (DME) as a working electrode, Ag/AgCl as a reference electrode and Pt wire as a counter electrode. Square wave stripping method, which makes use of formation and deformation of amalgam, was adopted to determine the metal impurities, and pH 7 phosphate buffer was used as supporting electrolyte. Results: Tl, Cu and Pb in thallous-201 chloride solution were detected by scanning from 300 mV to -800 mV Calibration curves were made by using $TINO_3,\;CuSO_4\;and\;Pb(NO_3){_2}$ as standard solutions. Tl was confirmed at -450 mV peak potential and Cu at -50 mV Less than 2 ppm of Tl and Cu was detected and Pb was not detected in KCCH-produced thallous-201 chloride injection. Conclusion: Detection limit of thallium and copper is approximately 50 ppb with this method. As a result of this experiment, thallium and other metal impurities in thallous-201 chloride injection, produced at Korea Cancer Center Hospital, are in the regulation of USP and KP Polarograph could be applied for the determination of metal impurities in the quality control of radiopharmaceuticals conveniently without environmental contamination.

  • PDF

Micromachined pH Sensor Using Open Well Structures (개방형 우물 구조를 이용한 마이크로머신형 pH 센서)

  • Kim, Heung-Rak;Kim, Young-Deog;Jeong, Woo-Cheol;Kim, Kwang-Il;Kim, Dong-Su
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.347-353
    • /
    • 2002
  • A structure of a glass electrode-type pH sensor for measuring any concentration of $H^+$ in an aqueous solution was embodied with bulk micromachining technology. Two open well structures were formed, and a reference electrode was secured by the Ag/AgCl thin film in the sloped side of the etched structure. A sensitive membrane of an indicator electrode for generating a potential by an exchange reaction to $H^+$ was made with a glass containing Na 20% or more finely so that its thickness might be $100{\mu}m$ or so, and then it was bonded to one pyramidal structure. A liquid junction for a current path was formed by filling an agar in the anisotropically etched part of the Si wafer, which had a size of $50{\mu}m{\times}50{\mu}m$, and then bonded it to the other. After complete fabrication of each part, it was filled with a 2M KCl reference solution and encapsulated the sensor structure with a cold expoxy. The potential value of fabricated pH sensor was about 90mV/pH in the standard pH solutions.

Embeddable reference sensors for corrosion monitoring in concrete structures (콘크리트 구조물의 부식감시용 매설형 기준전극의 전기화학적 안정성에 관한 연구)

  • Ha, Tae-Hyun;Bae, Jeong-Hyo;Ha, Yoon-Cheol;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.11a
    • /
    • pp.160-163
    • /
    • 2005
  • Several sensors are involved in the cor개sion monitoring of concrete structures. This paper deals with the monitoring of concrete structures by embeddable reference sensors. $MnO_2$, MMO and graphite reference sensors are fabricated in the laboratory as suitable as embeddable type into the concrete structures. Sensors are embedded into the mortars and the performance was studied in the absence and presence of chloride ions. The electrochemical stability of the sensors was carried out for the exposure period of one year. Polarisation behaviour and impedance of the sensors in mortar was carried out in three aqueous solutions namely distilled water, 3% NaCl and natural sea water.

  • PDF