• Title/Summary/Keyword: 기술 분류

Search Result 6,587, Processing Time 0.041 seconds

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

Application of Radiological Study by Small Bowel Disease - Comparison of Diagnostic Results of Small Bowel Series and Abdominal Pelvic Computed Tomography - (소장 질환별 방사선학적 검사의 적용에 관한 연구 - 소장조영술과 복부골반전산화단층촬영의 결과 분석을 중심으로 -)

  • Lee, Hee-Jung;Son, Soon-Yong;Lee, Won-Hong
    • Journal of radiological science and technology
    • /
    • v.28 no.4
    • /
    • pp.279-286
    • /
    • 2005
  • Purpose : There are two modalities, those are small bowel series(SBS) and abdominal pelvic computed tomography(CT), for diagnosis of small bowel disease. The aim of this study is to lend radiological technologists who are doing the two modalities assistance in the understanding characteristic of disease by comparing the two results. Meterials and method : 284 patients were examined the two SBS and abdominal pelvic CT together from 1999 to 2003. 250 ml $BaSO_4$ suspension 40 w/v% and 600ml carboxy methyl cellulose 0.5 w/v% were used for SBS. Abdominal Pelvic CT was examined in one hour before taking 450 ml $BaSO_4$ suspension 1.5 w/v%. The CT scan was done in 72 sec after 150 ml contrast media injection. the used protocol was helical mode 5:5 mm pitch 1.375:1, speed 27.50, exposure 120 kv, 240 mA, tube rotation time 0.5 sec. the statistic analysis was conducted with statistical program SPSS 10 version with frequency and crossing analysis. P-value less than 0.05 were considered significant. Results : In the results of SBS, normal findings were 131 patients(46.1%), inflammatory bowel disease(IBD) 64(22.9%), ischemia+ileocolitis+vasculitis 22(7.7%), Obstruction+stricture 21(7.7%) and Others 45(15.9%). In the results of abdominal pelvic CT, normal findings were 103 patients(36.3%), inflammatory bowel disease 65(22.9%), wall thickening+lymphadenopathy 42(14.8%), Fluid collection 17(6%), and Others 57case(20%). The same results of the two were 130patients(45.8%). 30patients(10.6%) of normal finding in SBS were diagnosed as wall thickening+lymphadenopathy and IBD in CT, and 15patients(5.3%) of normal finding in CT were diagnosed as ischemia+ileocolitis+vasculitis, mass and IBD in SBS(p<0.05). Transit time delay was diagnosed in 10patients(3.5%) on only SBS, wall thickening+lymphadenopathy was diagnosed in 20patients(7%) in only CT(p<0.05). Conclusion : We think that proper examination method will be selected in the small bowel disease, if we understand the characteristics of the disease and method.

  • PDF

The Effect of protein and lipioperoxide on White Ginseng(WG) and Fermenta Ginseng(FG) Extracts on the liver in Mice that was irradiated by radiation (방사선이 조사된 생쥐 간에서 백삼과 발효인삼추출물이 단백질 및 지질과산화에 미치는 효과)

  • Ko, In-Ho;Chang, Chae-Chul;Koh, Jeong-Sam
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.43-50
    • /
    • 2004
  • The effects of ginseng extracts on liver damage induced by high energy x-ray were studied. To one group of ICR male mice were given white(50 mg/kg/day for 7 days, orally) and fermenta ginseng extracts(500 mg/kg/day for 7 days, orally)before irrdiation. To another group were irradiated by 5 Gy dose of high energy x-ray. Contrast group were given with saline(0.1 ml). This study also investigated the effect between MDA, protein content and ginseng extracts on hepatic damage. This study measured the level of MDA(malondialdehyde), protein content in liver tissue. Administrating orally white (50 mg/kg/day for 7 days, orally)and fermenta ginseng extracts(500 mg/kg/day), the level of MDA were generally decreased and the inhibition was increased. And the protein contents were identical with control group. After irradiation, the protein contents were increased and MDA(malondialdehyde) was increased. Therefore, ginseng extracts increased antioxidative enzyme activity. And We know that the antioxidatant effect of extracts from white and fermenta ginseng protect radiation damage by direct antioxidant effect involving SOD, CAT, GPX. It was included that ginsengs can protect against the lipid peroxidation in radiation damage through its antioxidatant properties.

  • PDF

Study of Radiological Approach to Treat a Chronic Constipation (만성변비환자의 방사선학적 접근방법에 관한 고찰)

  • Yoon, Seok-Hwan
    • Journal of radiological science and technology
    • /
    • v.27 no.3
    • /
    • pp.5-12
    • /
    • 2004
  • I. Introduction : The constipation is one of the common gastrointestinal symptoms seen in the clinical practice. When people come to the clinic complaining of the constipation, it is generally one of the cases of infrequent, painful or difficult evacuation as well as the hardened feces and unsatisfactory evacuation sense. Since the constipation is heavily influenced by dietary habit as well as the social and medical environment, the diagnostic radiology is useful to establish the objective and standardized definition in consideration of those various factors before diagnosis and treatment of the constipation patient. This paper describes the study of such diagnosis. II. Main Subject : Testing of CTT (colon transit time) is key study of the colon performance. CTT is very helpful in classifying the pathologic physiological types and defining the treatment plan for the chronic constipation. The study methods include using the radipaque marker, multiple marker technique and scintigraphic measurement. The defecography is the functional radiologic examination a that provides not only the anatomical information of anorectal but also performance of the pelvic floor and rectal change during evacuation. Study of dynamic movement of the anorectal during evacuation is helpful for diagnosis and treatment planning as well as follow-up testing for the constipation patient. One of the issues essential for the case history is the thorough observation of whether the patient shows the psychic psychological symptoms such as the behavior disorder or emotional disturbance. In that case, the decision must be made whether or which type of medication is needed for such psychiatric problem. III. Conclusion : The main causes of the constipation are insufficient intake of fiber or liquid. The key objective of such tests is to check etiology of the constipation. In general, the radiological examination does not provde the colon or anorectal performance information. It is envisaged that this study will provide the information to decide the testing and treatment plans and predict the prognosis of the patient by classifying the pathologic physiological types.

  • PDF

The Clinical Usefulness Measurement of the Whole Body Percent Fat Calculated by the Part Bone Mineral Density Measurement (부분골밀도 측정을 통해 산출되는 체지방률의 임상적 유용성에 대한 평가)

  • Kang, Young-Eun;Kim, Eun-Hye;Kim, Ho-Sung;Choi, Jong-Sook;Choi, Woo-Jun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.3-9
    • /
    • 2011
  • Purpose: Generally dual energy X-ray absorptiometry has been used for the purpose of evaluation of osteoporosis and treatment. Recently the interest of obesity came to be high and body percent fat test is increasing. Existing measure of body fat have to scan the whole body can be evaluated, but only lumbar spine and hip measurements was assumed to be whole body fat as well as improving the software. It tries to check whether the part measured value not being whole body measurement has the validity or not compared with the value calculated with the method that it is different, it forgives through a correlation with a (BIA) and (BMI). Materials and Methods: In 2010, the body percent fat was measured among the examinee coming to the Asan Medical Center public health care center from March till August against 90 females more than 40 years old through (DXA) and BIA. BMI utilized the value which wrote an hight and weight measured through the body measuring instrument in the examinee information and is automatically calculated. In addition, it classified as the low weight ($13-18.5kg/m^2$), normal ($18.5-25kg/m^2$), and corpulence ($25-30kg/m^2$) based on BMI and so that it could check whether there was the difference according to the weight or not BMI and BIA and correlation between DXA were analyzed in each group. The statistical program for the analysis used SPSS 12.0. Results: The comparison of DXA at 3 which it divides into the low weight and normal and corpulence groups and BIA did not show the difference noted statistically in all groups and the between group comparison was exposed to do not have a meaning. The body percent fat measured by the correlation analysis result DXA at the state that it doesn't divide into the group showed the high correlation (r=0.908, p0.01) noted statistically compared with BMI and showed the high correlation noted statistically in a comparison with BIA (r=0.927, p0.01). Conclusion: It confirmed that the whole body percent fat presumed from the part bone density measurement showed the excel correlation compared with BIA and BMI and information is high. There is still no clear standard about the presumed whole body percent fat and it is difficult to evaluate the fat evaluation by the bone mineral density measurement. However, it is determined that the information offering which is more objective through the comparative study with the body percent fat which is very efficient and in that it can obtain till the information about a fat as well as diagnosis of the osteoporosis through the bone density checkup is measured by the afterward telegraph bone density checkup and is clinically useful is possible.

  • PDF

Comparison of Blood Glucose Level in Pancreatic Cancer on $^{18}F$-FDG PET (췌장암 환자의 양전자방출단층촬영(PET) 검사 시 혈당치와 영상에 관한 분석)

  • Oh, Shin-Hyun;Lee, Seung-Jae;Park, Hoon-Hee;Park, Yong-Sung;Kang, Chun-Goo;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.65-69
    • /
    • 2011
  • Purpose: Normal pancreas has low uptake rate in $^{18}F$-FDG PET scan. However, it is possible to diagnose malignancy of pancreatic cancer which has high uptake rate. Many studies approve a high prevalence of diabetes in pancreatic cancer and if the blood glucose level (BGL) is over the normal range, FDG uptake will be decreased and there will be inconvenience for patients from the delay time to reduce the high BGL or could cause difficulty to arrange the schedule. Therefore, we studied the relation of BGL and image quality in pancreatic cancer on PET. Materials and Methods: A hundred patients had PET scan. The prevalence of pancreatic cancer and diabetes were evaluated using SPSS ver. 17. The fasting BGL of patients were examined and sorted as diabetes mellitus (DM) group and Non-DM group. For the evaluation, patients were divided into 3 groups (Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L). The ROI was drown on Liver and Lung for the PET imaging analysis. Results: Fifty three male and forty seven female were in the patients. The average age was $60.1{\pm}13.5$. There were 36 patients (male: 22, female: 14, 36%) who had pancreatic cancer with DM. There were 15 patients who showed over 7.0 mmol/L in their fasting BGL and 85 patients who showed under 7.0 mmol/L in their fasting BGL. Among the Non-DM, DM; BGL${\geq}7.0mmol/L$, and DM; BGL<7.0 mmol/L, there was not a statistical significance (p>0.05). Conclusion: The prevalence of pancreatic cancer was comparatively high in this study. If the fasting BGL was slightly over the normal BGL, we believe it will not give a severe disturbance when the patients have PET scan. Furthermore, the examination schedule doesn't need to change and the inconvenience from the delay of patients preparation will be reduced.

  • PDF

The Evaluation of Usefulness of Wide Beam Reconstruction Method on Segmental Perfusion and Regional Wall Motion in Myocardial Perfusion SPECT (심근관류 SPECT의 분절별 관류 및 국소벽 운동에서 Wide Beam Reconstruction기법의 유용성 평가)

  • Seong, Yong-Joon;Kim, Tae-Yeob;Moon, Il-Sang;Cho, Seong-Wook;Woo, Jae-Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • Purpose: The aim of this study is to identify clinical usefulness of Wide Beam Reconstruction (WBR) which is called Xpress.cardiac$^{TM}$ to confirm the agreement between segmental perfusion and regional wall motion in myocardium compared to conventional OSEM method. Materials and Methods: Subjects were separated two groups. First group was composed of 20 normal control group. Second group was composed of 10 patients (abnormal group) who had coronary artery disease. Subjects underwent myocardial perfusion SPECT ($^{201}Tl$ rest and $^{99m}Tc$-MIBI stress). Image acquisition and reconstruction were that rest stage was each step per 30, 15 seconds and stress stage was each step per 25, 13 seconds, OSEM and WBR methods were applied. Segmental perfusion and regional wall motion were applied 20-segment model of QPS, QGS algorithm in AutoQuant. Status of perfusion was composed of 5 point scoring system (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). Status of regional wall motion was also composed of 5 point scoring (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). We evaluated the agreement between conventional OSEM and WBR through automatic quantification value. Results: The agreement of rest segmental perfusion between conventional OSEM and WBR in normal patients was 99% (396/400, k=0.662, p<0.0001) and one of rest regional wall motion was 83.8% (335/400, k=0.283), the agreement of stress segmental perfusion was 95.8%(383/400, k=0.656), one of stress regional wall motion was 87.3% (349/400, k=0.390). The match rate of rest segmental perfusion in abnormal patients was 83% (166/200, k=0.605, p<0.0001) and one of rest regional wall motion was 55.5% (111/200, k=0.385), the agreement of stress segmental perfusion was 79.5% (159/200, k=0.682), one of stress regional wall motion was 63.5% (127/200, k=0.486). Conclusion: Compared to conventional OSEM, WBR method had a good agreement of segmental perfusion in myocardium in normal and abnormal groups. However regional wall motion showed meaningful low agreement. Although WBR offers high resolution and contrast ratio, it is not useful method for gated myocardial perfusion SPECT.

  • PDF

Assessment and Comparison of SUVs of Three Different PET/CT Scanners (장비에 따른 SUV의 차이와 이에 관한 고찰)

  • Kim, Tae-Yeob;Lim, Jung-Jin;Lee, Hong-Jae;Kim, Hyun-Joo;Kim, Joong-Hyun;Lee, Jae-Sung
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.34-38
    • /
    • 2011
  • Purpose: The SUV is a widely used semi-quantitative index in PET for the estimation of radio-tracer accumulation in VOI. In this study, SUVs from three different PET/CT scanners were assessed, and differences between SUVs were evaluated. Materials and Methods: The PET/CT scanners which were assessed in this study were GEMINI, GEMINI TF 64 (Philips) and Biograph True Point True V 40 (Siemens). The NEMA PET phantom (Data Spectrum Corp., USA) was used to evaluate SUVs. The NEMA PET phantom has6.8 kg weight and three hot inserts. Two different activity distributions for the background and inserts were tested. The activity ratio were 3.7:3.7:7.4:11.1 MBq (1:1:2:3) and 1.85:7.4:9.25:11.1MBq (1:4:5:6) for each of background, insert 1, insert 2 and insert 3. Acquisition time was 2 minutes per bed position and NEMA PET phantom could be covered by two bed positions for all PET/CT scanners. The SUVs from each PET/CT scanner were compared with calculated true value. Results: For both activity ratios, all scanners showed similar results. The differences between each scanner were insignificant. Each scanner showed 91.2%, 85.9% and 87.2% of true SUV for GEMINI, GEMINI TF 64, Biograph True Point TrueV, respectively. Conclusion: For all scanners, SUVs were slightly lower than true value. However, the difference between scanners was insignificant. The SUVs from these scanners would be clinically meaningful if their consistent underestimation is kept in mind.

  • PDF

A Study on the Hull-dimension of 89 ton class Stow-net Vessel with Stern-fishing (89톤급 선미식 안강망어선의 선형치수에 관한 연구)

  • Park, Je-Ung;Lee, Hyeon-Sang
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.3
    • /
    • pp.159-165
    • /
    • 1997
  • This paper presents the optimum dimension of 89 ton class stow-net vessel with stern-fishing. The model of basic design is developed by using the optimization techniques referring to objective function and numerous constraints as follows; speed, fishing quantity, fishing days, catch per unit effort(CPUE), and weight/ratio of main dimensions, etc. Thus, the basic design of stow-net fishing vessel is built up by using the optimization of the design variables called the economic optimization criteria, and the objective function represents the criterion which is cost benefit ratio(CBR). The main conclusions are as follows. 1. S/W for decision of optimum hull size is developed in 89 ton class stow-net fishing vessel which is constructed with optimization of the design variables called the economic optimization criteria. 2. For optimum ship dimensions in 89 ton class stow-net fishing vessel, the hull dimensions can be obtained in the range of L= 27.3m, B = 6.6m, D = 2.80m, Cb = 0.695, T/D = 0.80, $\Delta$(displacement)=281.7ton with 10 knots.

  • PDF

Comparing the Change in SUVmax Over Time by the Type of Ductal Breast Carcinoma (유방암 환자 중 유관에서 발병되는 암의 종류(IDC와 DCIS)별 시간경과에 따른 SUVmax 변화에 대한 비교)

  • Hyoung, Mi-Jin;Kim, Jeong Nip;Moon, Pyeong Soo;Kim, Kil Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.140-144
    • /
    • 2014
  • Purpose: The recent surge in breast carcinoma patients is reported in a variety of statistics. Breast cancer occurs mainly from duct and lobulus: 85% is from the breast ducts. The present study is aimed to distinguish the difference in $SUV_{max}$ changing over time by identifying the type of cancers attacking from the duct. Materials and Methods: The subjects of the study are 291 female breast cancer patients who have visited the present PET/CT center from July 1, 2012 to July 23, 2013. Based on the pathological results, 248 IDC (invasive ductal carcinoma) patients and 43 DCIS (ductal carcinoma in situ) patients were selected. In the same manner as the general PET/CT scan (3.7 MBq/Kg), F-FDG was injected, followed by the primary test (Routine tests) after 1 hr, and the secondary test (Delay test) after another hr. $SUV_{max}$ was measured after setting ROI in the lesion based on the data from the two tests. Results: As the comparative result of the change in the lesion $SUV_{max}$ between the two groups, IDC group's $SUV_{max}$ showed M=7.11 and SD=5.405 in the primary test and increased M=7.11 and SD=5.405 in the secondary test (P<0.05); DCIS group's $SUV_{max}$ showed M=2.739, SD=1.229 in the primary test and increased M=2.614, SD=1.470 in the secondary test (P<0.05). Conclusion: As the comparative result of $SUV_{max}$ over time between the groups, IDC showed increased $SUV_{max}$ in the secondary test (Delay test) compared to the primary test (Routine test) (P=0.000); DCIS showed decreased $SUV_{max}$ in the secondary test (Delay test) compared to the primary test (Routine test) (P=0.039). It was confirmed through this study that the change in $SUV_{max}$ has occurred over time by the type of breast cancer (IDC or DCIS) occurring from the breast ducts. However, the onset of breast cancers (ILC, LCIS) from the lobulus was not discussed due to the lack of samples. Future research on the breast cancers from the lobulus is suggested.

  • PDF