• 제목/요약/키워드: 기술신뢰

Search Result 6,491, Processing Time 0.035 seconds

A sea trial method of hull-mounted sonar using machine learning and numerical experiments (기계학습 및 수치실험을 활용한 선체고정형소나 해상 시운전 평가 방안)

  • Ho-seong Chang;Chang-hyun Youn;Hyung-in Ra;Kyung-won Lee;Dea-hwan Kim;Ki-man Kim
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.293-304
    • /
    • 2024
  • In this paper, efficient and reliable methodologies for conducting sea trials to evaluate the performance of hull-mounted sonar systems is discussed. These systems undergo performance verification during ship construction via sea trials. However, the evaluation procedures often lack detailed consideration of variabilities in detection performance due to seabed topography, seasonal factors. To resolve this issue, temperature and salinity structure data were collected from 1967 to 2022 using ARGO floats and ocean observers data. The paper proposes an efficient and reliable sea trial method incorporating Bellhop modeling. Furthermore, a machine learning model applying a Physics-Informed Neural Networks was developed using the acquired data. This model predicts the sound speed profile at specific points within the sea trial area, reflecting seasonal elements of performance evaluation. In this study, we predicted the seasonal variations in sound speed structure during sea trial operations at a specific location within the trial area. We then proposed a strategy to account for the variability in detection performance caused by seasonal factors, using results from Bellhop modeling.

Evaluation of Quality Standards of Bio-Diesel (BD100, BD20) Manufactured Using Waste Frying Oil (폐식용유를 이용하여 제조한 바이오디젤(BD100, BD20)의 품질기준 평가)

  • Na, Seong-Joo;Jeon, Byung-Gwan
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.1
    • /
    • pp.39-48
    • /
    • 2009
  • Biodiesel is estimated to be the best recycling energy source as an alternative fuel for transportation vehicles which represents the biggest share of greenhouse effect gas exhausts. Thus, in order to widely expand use of biodiesel and to enhancement its reliability, studies on quality improvement of biodiesel is needed. In this study, we have produced biodiesel(BD100, BD20) through esterification reaction using raw material of waste frying oil and analyzed compatibility with 24 items of quality criteria. As waste frying oil has high contents of unsaturated fatty acid such as Oleic acid, Linoleic acid and Linolenic acid, it is confirmed that there is no problem in using the same as a raw material of biodiesel. The result of analyzing the quality criteria items of biodiesel showed that it satisfied all the quality criteria except the oxidation stability of BD100, which was 2 hours, fatty acid methyl ester of BD20, which was 18.6w% and the filter plugging point, which was $-5^{\circ}C$. We believe that it will contribute to improved utilization of waste resources as alternative energy if studies on technology to improve quality of some items are provided.

Conceptual Understanding of Heritage Archives (헤리티지 아카이브의 개념적 이해)

  • Jong Chul Lim
    • Journal of Korean Society of Archives and Records Management
    • /
    • v.24 no.3
    • /
    • pp.85-104
    • /
    • 2024
  • While there have been ongoing discussions and attempts to utilize archives for marketing purposes in various organizations, including businesses, there has been a lack of clarity regarding what should be archived and what should be considered as marketing targets within an organization's history. Consequently, historical marketing has often been past-oriented, with results varying significantly based on the capabilities of those in charge. To introduce and effectively utilize archives in organizational settings, it is crucial to demonstrate that archives can positively impact organizational performance. The Heritage Archives is a utilization plan that offers an approach to digitizing and preserving the valuable heritage and assets of a business, explaining them to various stakeholders through records, serving as a foundation for building trust in the business, and linking them to marketing, branding, and other applications. This study focuses on fundamental concepts for constructing and utilizing heritage archives by defining and interpreting key concepts such as the affordance of records, organizational heritage, and heritage assets. To this end, the study incorporates Geoffrey Yeo's affordance and John M.T. Balmer's concept of heritage. In addition, it compares definitions of assets in KS Q ISO 55000:2021, KS X ISO 15489-1:2016, and KS X ISO 30300:2020. Through the study's findings, insights can be obtained for organizations seeking to implement heritage archives and leverage them for marketing, branding, and related purposes.

Development of checklist questions to measure AI capabilities of elementary school students (초등학생의 AI 역량 측정을 위한 체크리스트 문항 개발)

  • Eun Chul Lee;YoungShin Pyun
    • Journal of Internet of Things and Convergence
    • /
    • v.10 no.3
    • /
    • pp.7-12
    • /
    • 2024
  • The development of artificial intelligence technology changes the social structure and educational environment, and the importance of artificial intelligence capabilities continues to increase. This study was conducted with the purpose of developing a checklist of questions to measure AI capabilities of elementary school students. To achieve the purpose of the study, a Delphi survey was used to analyze literature and develop questions. For literature analysis, two domestic studies, five international studies, and the Ministry of Education's curriculum report were collected through a search. The collected data was analyzed to construct core competency measurement elements. The core competency measurement elements consisted of understanding artificial intelligence (6 elements), artificial intelligence thinking (4 elements), artificial intelligence ethics (4 elements), and artificial intelligence social-emotion (3 elements). Considering the knowledge, skills, and attitudes of the constructed measurement elements, 19 questions were developed. The developed questions were verified through the first Delphi survey, and 7 questions were revised according to the revision opinions. The validity of 19 questions was verified through the second Delphi survey. The checklist items developed in this study are measured by teacher evaluation based on performance and behavioral observations rather than a self-report questionnaire. This has the implication that the measurement results of competency are raised to a reliable level.

Development and Performance Evaluation Results of Remote Control Systems for Maritime Autonomous Surface Ships (자율운항선박의 원격제어 시스템 개발과 성능평가 결과)

  • Hong-Jin Kim;Hwa-Sop Roh;Jeong-Bin Yim
    • Journal of Navigation and Port Research
    • /
    • v.48 no.4
    • /
    • pp.335-341
    • /
    • 2024
  • Recently, research, development, and commercialization of maritime autonomous surface ships (MASS) and remote control are in progress. Remote control is intended to secure autonomous navigation environments for existing ships or early-stage MASS using a remote control system (RCS). The main function of an RCS is to control MASS using data transmission between the MASS and the remote control centre. Remote control by a remote control officer also has an important function. The purpose of this study was to develop RCS and a performance evaluation technique for operation data provided by the RCS. The experiment was conducted during the navigation period of a training ship 'Hannara' after building experimental equipment at both an onshore remote control center and a training ship. As a result of evaluating data transmitted and received using the developed RCS, it was confirmed that data transmission was possible within an error range of 0.1%p. Fourteen types of ship information reflecting the navigation environment of the training ship were confirmed to be transmitted and received. The RCS developed in this work complies with the three principles of remote control: safety, reliability, and availability. This study provides a core technology for the development of RCSs for MASS and the evaluation of data transmission performance.

A Study on the Effects of Support Service of Gyeonggi-do Cultural Contents Area Business Incubating Center on Corporate Performance: Focusing on the Business Validity of Business Start-Up Items (경기도 문화콘텐츠분야 창업보육센터 지원서비스가 입주기업 성과에 미치는 영향에 관한 연구: 창업아이템의 사업타당성을 중심으로)

  • Hong, Dae Ung;Lee, Il han;Son, Jong Seo
    • Asia-Pacific Journal of Business Venturing and Entrepreneurship
    • /
    • v.12 no.4
    • /
    • pp.47-60
    • /
    • 2017
  • As the recent cultural contents area start-ups are creating remarkable outcomes such as investment attraction together with the reinforced institutional supports from the government, this study aimed to reverify the significance of researches related to correlation analysis between service of Business Incubating Center of Small & Medium Business Administration operated with no separation of business type, and corporate performance, in the aspect of Business Incubating Center in cultural contents area, and also to suggest the importance of establishing the business incubating system in the systematic and rational cultural contents area through the differentiated business incubating service by verifying the significant effects of the business validity of items on corporate performance, and then discovering services suitable for business incubating in cultural contents area, targeting Gyeonggi-do cultural contents area Business Incubating Center recently showing the biggest growth. Especially, contrary to the existing researches, in order to verify the characteristics of Gyeonggi-do Cultural Contents Business Incubating Center, the personal support service and marketing support service were included. It also aimed to understand the effects of the business validity of start-up items on corporate performance. Summarizing the results of this study, contrary to the results of the existing researches saying that spatial & additional support service, management support service, technical support service, personal support service, and marketing support service had significant effects on corporate performance, among the support service of Gyeonggi-do cultural contents area Business Incubating Center, the spatial & additional support service, personal support service, and marketing support service had significantly positive(+) effects on corporate performance while the management support service and technical support service had no significant effects on it. Comparing with the results of the researches on the support service of Business Incubating Center(BI) of Small & Medium Business Administration, the effects of the management support service and technical support service of Gyeonggi-do cultural contents area Business Incubating Center on corporate financial/non-financial performance were not huge. Also, in the results of analyzing the business validity of star-up items, the spatial & additional support service, management support service, and technical support service did not have significant effects on the business validity of start-up items while the personal support service and marketing support service had significantly positive(+) effects on it. In case when selecting companies, Gyeonggi-do Business Incubating Center emphasized the business validity of start-up items. However, the support service provided after the selection did not have huge effects on the business validity of start-up items. Lastly, in the results of analyzing the effects of the business validity of start-up items in Gyeonggi-do cultural contents area on corporate performance, among the success factors of business start-up, the business validity of start-up items was an important element having effects on corporate performance(financial/non-financial) in the cultural contents area.

  • PDF

Interlaboratory Comparison of Blood Lead Determination in Some Occupational Health Laboratories in Korea (일부 산업보건기관들의 혈중연 분석치 비교)

  • Ahn, Kyu Dong;Lee, Byung Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.1
    • /
    • pp.8-15
    • /
    • 1995
  • The reliable measurement of metal in biological media in human body is one of critical indicators for the proper evaluation of its toxic effect on human health. Recently in Korea the necessity of quality assurance of measurement in occupational health and occupational hygiene fields brought out regulatory quality control program. Lead is often used as a standard metal for the program in both fields of occupational health and hygiene. During last 20 years lead poisoning was prevalent in Korea and still is one of main heavy metal poisoning and the capability of the measurement of blood lead is one of prerequisites for institute of specialized occupational health in Korea. Furthermore blood lead is most important indicator to evaluate lead burden of human exposure to lead and the reliable and accurate analysis is most needed whenever possible. To evaluate the extent of the interlaboratory differences of blood lead measurement in several well-known institute specialized in occupational health in Korea, authors prepared 68 blood samples from two storage battery industries and all samples were divided into samples with 2 ml. One set of 68 samples were analyzed by authors's laboratory(Soonchunhyang University Institute of Industrial Medicine: SIIM) and 40 samples of other set were analyzed by C University Institute of Industrial Medicine(CIIM) and the rest 28 samples of other set were analyzed by Japanese institute(K Occupational Health Center:KOHC). Authors also prepared test bovine samples which were obtained from Japanese Federation of Occupational Health Organization (JFOHO) for quality control. Authors selected 2 other well-known occupational health laboratories and one laboratory specialized for instrumental analysis. A total of 6 laboratories joined the interlaboratory comparison of blood lead measurement and the results obtained were as follows: 1. There was no significant difference in average blood lead between SIIM and CIIM in different group of blood lead concentration, and the relative standard deviation of two laboratories was less than 3.0%. On the other hand, there was also no significant difference of average blood lead between SIIM and KOHC with relative standard deviation of 6.84% as maximum. 2. Taking less than 15% difference of mean or less than 6 ug/dl difference in below 40 ug/dl in whole blood as a criteria of agreement of measurement between two laboratories, agreement rates were 87.5%(35/40) and 78.6%(22/28) between SIIM and CIIM, SIIM and KOHC respectively. 3. The correlation of blood lead between SIIM and CIIM was 0.975 (p=0.0001) and the regression equation was SIIM = 2.19 + 0.9243 ClIM, whereas the correlation between SUM and KOHC was O.965(p=0.0001) with the equation of SIIM = 1.91 + 0.9794 KOHC. 4. Taking the reference value as a dependent variable and each of 6 laboratories's measurement value as a independent variable, the determination coefficient($R^2$) of simple regression equations of blood lead measurement for bovine test samples were very high($R^2>0.99$), and the regression coefficient(${\beta}$) was between 0.972 and 1.15 which indicated fairly good agreement of measurement results.

  • PDF

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF

The Evaluation of Clinical Usefulness on Application of Myocardial Extract in Quantitative Perfusion SPECT (QPS 프로그램에서 Myocardial extract 적용에 따른 임상적 유용성 평가)

  • Yun, Jong-Jun;Lim, Yeong-Hyeon;Lee, Mu-Seok;Song, Hyeon-Seok;Jeong, Ji-Uk;Park, Se-Yun;Kim, Jae-Hwan;Kim, Jeong-Uk
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.88-93
    • /
    • 2011
  • Purpose: As to analytical method of data, the AutoQUANT software in which it is used quantitative rating of the myocardial perfusion SPECT are reported that there is a difference. Therefore the measured value error of the mutual program is expected to be generated even if the quantitative analysis is made data of the same patient. The purpose of this study is to offer the comparative analysis of myocardial extract method in Quantitative Perfusion SPECT. Materials and methods: We analyzed the 51 patients who were examined by Tc-99m MIBI gated myocardial SPECT in nuclear medicine department of Pusan National University Hospital from June to December 2010(34 men, 17 women, mean age $66.5{\pm}9.9$). We acquired the extracted image in myocardial extract protocol. QPS program that uses the AutoQUANT software measured TID(Transient Ischemic Dilation), ESD(Extent of Stress Defect), SSS(Summed Stress Score). Then analyzed the results. Results: The correlation of appyling myocardial extract is TID(r=0.98), ESD(r=0.99), SSS(r=0.99). In the 95% confidence limit, there was no satistically significant difference(TID p=0.78, ESD p=0.31, SSS p=0.19). After blinding test with a physician for making a qualitative analysis, there was no difference. Conclusion: Quantitative indices in QPS program showed good correlation and the results showed no statistically signigicant difference. The variance between method was small. therefore, the functional parameters by each method can be used interchangeably. Also, we expect patient's satisfaction.

  • PDF

The Reduction ways of Medicine Material Costs of Nuclear Medicine In Vitro (핵의학 체외검사의 진료재료비용 절감 방안)

  • Song, Hun-Kang;Seo, Jung-Mi;Yang, Joon-Ho;Kim, Eun-Jung;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.111-115
    • /
    • 2011
  • Purpose: In vitro uses dose response curve with 6 to 7 standard concentrations in every examination to analyze examination results and this use of dose response curve comprises a large portion of the consumption of medicine material. At this present, some ones of in-hospital examination items have shown mostly low result of distribution in the analyzed features and these examinations have been judged that it would be unnecessary to use the last standard concentration. Hence, this study selects those examination items showing low result of distribution and reviews the cases contributed to less consumption of medicine material and revenue growth of hospital by reduction of medicine material used in the place of the last standard concentration. Materials and Methods: The study was made targeting 11 examination items out of total 43 items of the in-hospital examination and since these examination items were mostly low in the features as the examination results of patients or the examination results were distributed to show lower concentration than the previous last standard concentration, it carried out the examination without using the last standard concentration, which could generate the effect to reduce medicine material (examination tube) used in the last standard concentration as many as the number of examination carried out. For this, it examined the number of medicine material reduction by month during the period from July, 2009 to February, 2011 and estimated the reduction amount of medicine material calculated the number of reduction by the unit cost of medicine material as well as the profit generated by the reduced medicine material to use for the medicine material of patient examination. Results: The total number of medicine material reduced during the period from July, 2009 to February, 2011 was 3,131 pieces, which had the effect to reduce the medicine material equivalent to about 31 kits of reagent. To calculate this by the unit cost of the medicine material, it analyzed to reduce about 6.4 million won of medicine material cost. Also the reduced medicine materials were used for medicine materials of patient examination and this was analyzed to generate about 13.75 million won of profit based on the ABC cost accounting. Conclusion: It showed no problem in the analysis of examination result even without using the last standard concentration regarding those examination items with low distribution of the patient examination result. For these examination items, it was able to reduce medicine material used for the last standard as many as the number of examination carried out. Also, the adjustment of concentration range was found to have no problem in the reliability of examination result. Therefore, this case will be applicable in those occasions of when the analysis of patient examination result is mostly distributed at the lower level or when an examination with the distribution of patient results in the range of lower concentration than the previous last standard concentration is carried out and this is considered to increase the efficiency in the use of medicine material in vitro as well as contribute to the profit of hospitals.

  • PDF