• Title/Summary/Keyword: 기술관리

Search Result 24,020, Processing Time 0.051 seconds

Coastal Water Fisheries Resources Research Division, National Institute of Fisheries Science (근해 유자망에 의해 어획되는 참조기자원의 관리를 위한 가입당 산란자원량 모델의 비교분석)

  • LEE, Eun Ji;SEO, Young Il;PARK, Hee Won;KANG, Hee Joong;ZHANG, Chang Ik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.4
    • /
    • pp.535-544
    • /
    • 2015
  • Yield per recruit model is the most popular method for fisheries stock assessment. However, stock assessment using yield per recruit model can lead to recruitment overfishing as this model only considers the maximum yield per recruit without spawning biomass for reproduction. For this reason, spawning biomass per recruit model which reveals variations of spawning stock biomass per fishing mortality (F) and age at first capture ($t_c$) is considered as more proper method for stock assessment. There are mainly two methods for spawning biomass per recruit model known as age specific selectivity method and knife-edged selectivity method. In the knife-edged selectivity method, the spawning biomass per recruit has been often calculated using biomass per recruit value by multiplying the maturity ratio of the recruited age. But the maturity ratio in the previous method was not considered properly in previous studies. Therefore, a new method of the knife-edged selectivity model was suggested in this study using a weighted average of the maturity ratio for ages from the first capture to the lifespan. The optimum fishing mortality in terms of $F_{35%}$ which was obtained from the new method was compared to the old method for small yellow croaker stock in Korea. The value of $F_{35%}$ using the new knife-edged selectivity model was 0.302/year and the value using the old model was 0.349/year. However, the value of $F_{35%}$ using the age specific selectivity model was estimated as 0.320/year which was closer to the value from the new knife-edged selectivity model.

Limits of STEAM Education and its Improvement Alternative : Based on the Viewpoints of STEAM Expert Teachers (STEAM 교육의 한계와 개선방향 -STEAM 교육 전문성을 가진 교사의 견해를 바탕으로-)

  • Son, Mihyun;Jeong, Daehong
    • Journal of The Korean Association For Science Education
    • /
    • v.39 no.5
    • /
    • pp.573-584
    • /
    • 2019
  • It is necessary to look at the essence of STEAM education from the viewpoint of the teacher who is the subject of education execution. We carry out questionnaires and telephone interviews for the purpose, definition, change, etc. of STEAM education from eight elementary, middle, and high teachers who are rich in policy and field application experience. As a result of the analysis, the purpose of the STEAM education that the specialists mentioned includes the active participation of the students. Most experts pointed out that the definition of STEAM education is ambiguous. So, it is necessary to express a clear goal of STEAM education. The category and level meaning "fields" from "a convergence of two or more fields" are not indicative definitions, but can be different depending on the situation, considering the context of activities and the level of students. The perception of the experts on framework may be a guide for STEAM education and stumbling block. It is necessary for "Context" to shift away from the emphasis on the real life connection and to the emphasis on the interest of the student and the guidance of the class. "Creative design" must be based on trial and error in the process of solving problems. "Emotional touch" needs to correct elements that cannot be observed, evaluated, and applied to lessons that are elements of emotional experience. As for the expansion of STEAM education, most expert teachers have recognized that STEAM education is becoming increasingly stable and that policy change has continued to slow the pace of stabilization.

A Study on the Current Status of Health Screening and the Health Type(Physical Activity, and etc) of the Disabled by Using the Statistics of Health Insurance Corporation (건강보험공단 통계를 이용한 장애인의 건강검진 현황 및 건강형태(신체활동 등)에 대한 소고)

  • Kim, Seck-Jin;Jung, Jin-Sung
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.433-444
    • /
    • 2018
  • This study aims to examine the screening rate of health screening of the disabled by screening the data of disability and health statistics of the National Health Insurance Corporation, to suggest the problems of health examination and the future improvement measures, and also to review the type of health management of the disabled based on the results of health examination interview. As people with limited daily life or social life for a long time because of their physical/psychological disabilities in accordance with the Article2 of , out of 2,479,080 registered people with disabilities on the basis of December 31st 2015, the research subjects were limited to people with disabilities who participated in the health screening and health type for presenting the opinions about policies. In conclusion, regarding the health screening for the disabled, first, it would be necessary to collect the opinions from people with disabilities in order to prepare the health screening service suitable for them. Second, it would be needed to develop the health screening items for each type of disability and severity. Third, it would be necessary to consider the medical equipments and amenities of health examination for the disabled. Fourth, there should be the securement of manpower and education for service providers. Fifth, the mobility right of the disabled should be secured. Regarding the health type of the disabled, first, the expert consultative group in each area should be composed for the health enhancement of the disabled. Second, it would be necessary to screening the current status of health enhancement programs for the disabled and operating facilities. Third, the Central Health Medical Center for the Disabled, shown in the law on the securement of health rights & medical accessibility of the disabled should develop the standardized health enhancement programs for each disability type and severity. After examining the contents of health examination and health type of the disabled, the opinions about policies were suggested. Thus, in the future, there should be more detailed researches based on the tasks suggested by this study, and also the causal relations between health of the disabled and relevant programs should be continuously revealed.

The Factors Influencing Intention to Use Bit Coin of Domestic Consumers (국내 소비자들의 비트코인 사용 의도에 영향을 미치는 요인 연구)

  • Shin, Dong-Hee;Kim, Yong-Moon
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.24-41
    • /
    • 2016
  • Study is about Bit Coin that is electronic cash that is received attention globally in recent. It is increasing domestically that uses bit coin for convenience of micro payment, and also bit coin is possible to exchange each countries' currency. In this point, we searched understanding degree and acceptance of bit coin. Also we applied transformed TAM(Technology Acceptance Model) to search factors that have an effect on consumers' intention to use it. In advance, we analyze features of bit coin, and extract factors through preceding researches for existing electronic cash, because studies for intention to use bit coin are weak in internal and external. First of results is that 'economic efficiency' which is a characteristic variable of bit coin influences 'intention to use,' a dependent variable through 'perceived usefulness,' a parameter. It was investigated that monetary and mental costs that was costed when we use bit coin were less than using other cash. Secondly, 'payment convenience' that is a characteristic variable affects 'intention to use', a dependent variable through 'perceived usefulness,' a parameter. It was measured that problems of inconvenience that include transaction process, cash management time shortage and exchange changes will be solved by using bit coin. Thirdly, 'reliability' that is a perceived risk variable of bit coin has a direct effect on 'intention to use,' a dependent variable. It was investigated that we could achieve purpose of payment because we weren't influenced by breakdown on system by processing distributed database in some computers. Fourthly, 'perceived usefulness,' a parameter of bit coin directly affects 'intention to use,' a dependent variable. Then consumers who want to use bit coin are fascinated bit coin for various usability. Moreover, we want to provide implications to all of finance corporations, companies related electronic cash and bit coin users based on these results.

Forecasting Hourly Demand of City Gas in Korea (국내 도시가스의 시간대별 수요 예측)

  • Han, Jung-Hee;Lee, Geun-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.2
    • /
    • pp.87-95
    • /
    • 2016
  • This study examined the characteristics of the hourly demand of city gas in Korea and proposed multiple regression models to obtain precise estimates of the hourly demand of city gas. Forecasting the hourly demand of city gas with accuracy is essential in terms of safety and cost. If underestimated, the pipeline pressure needs to be increased sharply to meet the demand, when safety matters. In the opposite case, unnecessary inventory and operation costs are incurred. Data analysis showed that the hourly demand of city gas has a very high autocorrelation and that the 24-hour demand pattern of a day follows the previous 24-hour demand pattern of the same day. That is, there is a weekly cycle pattern. In addition, some conditions that temperature affects the hourly demand level were found. That is, the absolute value of the correlation coefficient between the hourly demand and temperature is about 0.853 on average, while the absolute value of the correlation coefficient on a specific day improves to 0.861 at worst and 0.965 at best. Based on this analysis, this paper proposes a multiple regression model incorporating the hourly demand ahead of 24 hours and the hourly demand ahead of 168 hours, and another multiple regression model with temperature as an additional independent variable. To show the performance of the proposed models, computational experiments were carried out using real data of the domestic city gas demand from 2009 to 2013. The test results showed that the first regression model exhibits a forecasting accuracy of MAPE (Mean Absolute Percentage Error) around 4.5% over the past five years from 2009 to 2013, while the second regression model exhibits 5.13% of MAPE for the same period.

Calcium Removal from Effluent of Electronics Wastewater Using Hydrodynamic Cavitation Technology (수리동력학적 캐비테이션을 이용한 전자폐수 처리수에 함유된 칼슘저감에 관한 연구)

  • Park, Jin-Young;Kim, Sun-Jip;Lee, Yong-Woo;Lee, Jae-Jin;Hwang, Kyu-Won;Lee, Won-Kwon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.6
    • /
    • pp.715-721
    • /
    • 2007
  • Residual calcium concentration is high, in general, at the effluent of the fluoride removal process in the electronics industry manufacturing semiconductor and LCD. To increase the stability of the membrane process incorporated for reuse of wastewater, the residual calcium is required to be pre-removed. Hyperkinetic Vortex Crystallization(HVC) process was installed in the electronics industry manufecturing semi conductor as a pilot scale for accelerating calcification of calcium ion. Compared to the conventional soda ash method, the 31% higher calcium removal efficiency was achieved when HVC was applied at the same sodium carbonate dosage. In order to maintain the economic calcium removal target of 70% preset by manufacturer, the dosing concentration of the soda ash was 530 mg/L based on influent flowrate. The seed concentration in the reactor was one of the critical factors and should be maintained in the range of $800\sim1,200mg$ SS/L to maximize the calcium removal efficiency. The calcite production rate was 0.30 g SS/g $Na_2CO_3$ in the average. The economic HVC passing time of the mixture was in the range of $2\sim5$ times. Relatively, stable calcium concentration was maintained in the range of $30\sim72$ mg/L(average 49 mg/L) although the calcium concentration in the feed was severely fluctuated with $74\sim359$ mg/L(average 173 mg/L). The HVC process was characterized as environment-friendly technology reducing chemical dosage and chemical sludge production and minimizing maintenance cost.

Analysis of the Spatial Dose Rates during Dental Panoramic Radiography (치과 파노라마 촬영에서 공간선량률 분석)

  • Ko, Jong-Kyung;Park, Myeong-Hwan;Kim, Yongmin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.509-516
    • /
    • 2016
  • A dental panoramic radiography which usually uses low level X-rays is subject to the Nuclear Safety Act when it is installed for the purpose of education. This paper measures radiation dose and spatial dose rate by usage and thereby aims to verify the effectiveness of radiation safety equipment and provide basic information for radiation safety of radiation workers and students. After glass dosimeter (GD-352M) is attached to direct exposure area, the teeth, and indirect exposure area, the eye lens and the thyroid, on the dental radiography head phantom, these exposure areas are measured. Then, after dividing the horizontal into a $45^{\circ}$, it is separated into seven directions which all includes 30, 60, 90, 120 cm distance. The paper shows that the spatial dose rate is the highest at 30 cm and declines as the distance increases. At 30 cm, the spatial dose rate around the starting area of rotation is $3,840{\mu}Sv/h$, which is four times higher than the lowest level $778{\mu}Sv/h$. Furthermore, the spatial dose rate was $408{\mu}Sv/h$ on average at the distance of 60 cm where radiation workers can be located. From a conservative point of view, It is possible to avoid needless exposure to radiation for the purpose of education. However, in case that an unintended exposure to radiation happens within a radiation controlled area, it is still necessary to educate radiation safety. But according to the current Medical Service Act, in medical institutions, even if they are not installed, the equipment such as interlock are obliged by the Nuclear Safety Law, considering that the spatial dose rate of the educational dental panoramic radiography room is low. It seems to be excessive regulation.

Analysis of Bone Mellow Density in Adults of Domestic Local Area Using Multi-Detector Computed Tomography: Focus on Corelation About Eating Habits, Lifestyle, Physical Features and Social Characteristics (다중 검출 전산화단층촬영을 이용한 국내 일부 지역 성인의 골밀도 현황 분석: 식습관, 생활습관, 신체적, 사회적 특성과의 상관관계를 중심으로)

  • Lee, Tae Hui;Kim, Tae-Hyung;So, Woon Young;Lim, Hei Gyeom;Lim, Cheong-Hwan;Park, Myeong Hwan;Cheoun, Myung-Ki
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.517-526
    • /
    • 2016
  • This study analyzed the correlation between BMD (bone mineral density) value calculated in the MDCT (multidetector computed tomography) and lifestyle, physical features and social characteristics. From July 15 2015 to June 6 2016, we converted from HU (hounsfield unit) value measured by using MDCT to T-score for BMD of 141 patients (male: 63, female: 78) in W medical center. We measured the 2nd, 3rd and 4th lumbar spine and analyzed the correlation between gender differences in BMD and lifestyle, physical features and social characteristics. Statistical significance was validated using independent sample T test with one way Anova. Gender BMD was confirmed that a statistically significant difference (p<0.05). BMD values decreased with increasing age but for the statistically men, there was no significant difference from 20s to 50s, it only showed a significant difference in 20s and 60s (p<0.001). For the statistically women, there was no significant difference from 20s to 40s. but since 50s BMD was decreased rapidly, which showed a significant difference (p<0.001). women showed significant differences for the menstruation and menopause, childbirth, alcohol, cereals and greasy food in bone mineral density (p<0.05) but there were no significant differences in men. The bone mineral density values calculated by the MDCT and lifestyle, physical features and social characteristics correlation analysis method is considered to be used as a basis for estimating the state in BMD and osteoporosis management.

Comparison of Estradiol Results according to Manufacturer (제조회사에 따른 Estradiol 결과값의 비교)

  • Kim, Dae-Woon;Shin, Hee-Jung;You, Tae-Min;Noh, Gyeong-Woon;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.101-105
    • /
    • 2011
  • Purpose: Estradiol in the menstrual cycle and ovulation induction as an important test of currently national nuclear medicine laboratory in the normal patients and patients with infertility tests are being performed. For the diagnosis of menopause is an important test with follicle stimulating hormone (FSH) and Luteinizing hormone (LH). Currently participating in external quality control of the nation's hospitals that is 54 percent of 37 hospitals, 20 hospitals have been using A's reagent. The kit's test results are highly different from other kit comes with the test results of specimens have been found. And for the phenomenon is to study the problem. Materials and Methods: Estraiol test were referred to our hospital which results of samples as more than 100pg/ml 75 specimens measured by radioimmunoassay(RIA) test with company A company B company C company D Kit, Chemiluminescent assay (CMIA) to examine and compare to the results from april to August in 2010. Results: Kit for each manufacturing company as measured by the results obtained using the average value of the correlation coefficient (R2) and A company 0.8906 B 0.9527 C 0.9547 and D company correlation coefficient of 0.873 showed a good correlation that measuring the results of A company high concentrations when Company B Company C Company D with CMIA test concentrations measured low results that the two cases were discovered specimens. Conclusion: Most of the test results of 75 samples came up with a similar trend, but two cases were reported in the patients very differently. A company result reported higher than 700 pg/ml, while the rest of other test results report was approximately 10 pg/ml. The common point of two samples more than 50 years patients are estimated to be diagnosed with cancer in postmenopausal patients receiving treatment and levels of FSH were found to be greater than 50 mIU/ml. Did not identify the exact cause. I suggest if you are using A company kit that need to again check when Estradiol result and follicle stimulating hormone results is higher.

  • PDF

Usefulness of wearing pocket dosimeter in nuclear medicine (핵의학 영상검사에서 Pocket dosimeter 착용의 유용성 평가)

  • Kim, Young-Bin;Lee, Eun-Ji;Kim, Kun-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.25-28
    • /
    • 2011
  • Purpose: The aim of study is to find accuracy of pocket dosimeter in measuring exposed dose in compared with survey meter and to compare exposed dose according as Nuclear medicine exams. Materials and Method: First, radiation dose to point source(185 MBq,370 MBq, ${\ldots}$, 1665 MBq, 1850 MBq) were measured in using a pocket dosimeter and a survey meter. Second, radiation dose to 12 patients injected $^{18}F$-FDG 370 MBq were measured in using a pocket dosimeter and a survey meter. Third, radiation dose to 10 patients injected $^{99m}Tc$-DPD 925 MBq were measured in using a pocket dosimeter and a surveymeter. Result: The average is $70.12{\pm}39.36{\mu}Sv/h$ in measurement of point source with Surveymeter and $5{\pm}3.06{\mu}Sv$ in measurement of point source with Pocket dosimeter. The average is $25.04{\pm}6.16{\mu}Sv/h$ in measurement of PET/CT patients with Surveymeter and $2.41{\pm}0.51{\mu}Sv$ in measurement of PET/CT with Pocket dosimeter. The average is $8.58{\pm}0.96{\mu}Sv/h$ in measurement of Bone Scan patients with Surveymeter and $1{\mu}Sv$ in measurement of Bone Scan patients with Pocket dosimeter. Significant difference found between Survey meter value and Pocket dosimeter value in all experimentation (p<0.001). Conclusion: Accoring to rusult Wearing Pocket dosimeter is usefulnee in manerage of exposed dose in nucler medicine exams.

  • PDF