• Title/Summary/Keyword: 기술계수

Search Result 3,661, Processing Time 0.036 seconds

Analysis of the Impact of Satellite Remote Sensing Information on the Prediction Performance of Ungauged Basin Stream Flow Using Data-driven Models (인공위성 원격 탐사 정보가 자료 기반 모형의 미계측 유역 하천유출 예측성능에 미치는 영향 분석)

  • Seo, Jiyu;Jung, Haeun;Won, Jeongeun;Choi, Sijung;Kim, Sangdan
    • Journal of Wetlands Research
    • /
    • v.26 no.2
    • /
    • pp.147-159
    • /
    • 2024
  • Lack of streamflow observations makes model calibration difficult and limits model performance improvement. Satellite-based remote sensing products offer a new alternative as they can be actively utilized to obtain hydrological data. Recently, several studies have shown that artificial intelligence-based solutions are more appropriate than traditional conceptual and physical models. In this study, a data-driven approach combining various recurrent neural networks and decision tree-based algorithms is proposed, and the utilization of satellite remote sensing information for AI training is investigated. The satellite imagery used in this study is from MODIS and SMAP. The proposed approach is validated using publicly available data from 25 watersheds. Inspired by the traditional regionalization approach, a strategy is adopted to learn one data-driven model by integrating data from all basins, and the potential of the proposed approach is evaluated by using a leave-one-out cross-validation regionalization setting to predict streamflow from different basins with one model. The GRU + Light GBM model was found to be a suitable model combination for target basins and showed good streamflow prediction performance in ungauged basins (The average model efficiency coefficient for predicting daily streamflow in 25 ungauged basins is 0.7187) except for the period when streamflow is very small. The influence of satellite remote sensing information was found to be up to 10%, with the additional application of satellite information having a greater impact on streamflow prediction during low or dry seasons than during wet or normal seasons.

A Study on the Development and Validation of Three Systems of Action Scale in Home Economics for Middle and High School Students (중⋅고등학생용 가정교과 세 행동체계 척도 개발 및 타당화 연구)

  • Choi, Seong Youn
    • Journal of Korean Home Economics Education Association
    • /
    • v.35 no.3
    • /
    • pp.67-96
    • /
    • 2023
  • The purpose of this study was to develop and validate a scale that can grasp the reality of the three systems of action for middle and high school students in home economics. For this purpose, a total of 105 questions, 35 questions for each systems of action, were developed as a 5-point Likert scale in order to measure technical action, communicative action, and emancipative action as preliminary questions by reviewing domestic and international literature related to the three systems of action. The procedure for revising and supplementing the developed preliminary questions by reviewing the content validity of the home economics education expert was executed twice. A preliminary survey was conducted on middle and high school students with 70 developed preliminary questions, and 166 copies were collected. As a result of exploratory factor analysis of the collected questionnaires to test the validity of the scale, it was found that 38 questions 7 factors were appropriate. After constructing this survey based on the results of exploratory factor analysis, this survey was conducted on middle and high school students, and 548 copies were collected and a confirmatory factor analysis was performed. A total of 38 questions were finally selected through confirmatory factor analysis, including basic living ability 5 questions, self-management ability 4 questions, information processing ability 4 questions, communication/interpersonal ability 12 questions, critical thinking ability 3 questions, decision-making ability 7 questions, empowerment 3 questions. The Model Fit was χ2=1846.741(p<.001), CFI=0.865, TLI=0.853, RMSEA=0.058, and the Standardized Regression Weights for each question was more than 0.5, so it can be seen as a suitable measurement instrument for measuring the status of the three systems of action of middle and high school students in home economics. The three systems of action scales were found to have significant correlations with self-acceptance, future planning, intimacy, uniqueness, which are sub-factors of the self-identity scale, and social participation scales therefore confirmed that they have recognized concurrent validity.

A Structural Relationship among Job Requirements, Job Resources and Job Burnout, and Organizational Effectiveness of Private Security Guards (민간경비원의 직무요구 직무자원과 소진, 조직유효성의 구조적 관계)

  • Kim, Sung-Cheol;Kim, Young-Hyun
    • Korean Security Journal
    • /
    • no.48
    • /
    • pp.9-33
    • /
    • 2016
  • The purpose of the present study was to find out cause-and-effect relationship between job requirements and job resources, with job burnout as a mediator variable, and the effects of these variables on organizational effectiveness. The population in the present study was private security guards employed by 13 private security companies in Seoul and Gyeonggi-do areas, and a survey was conducted on 500 security guards selected using purposive sampling technique. Out of 460 questionnaires distributed, 429 responses, excluding 31 outliers or insincere responses, were used for data analysis. For analysis, data were coded and entered into SPSS 18.0 and AMOS 18.0, which were used to analyze the data. Descriptive analyses were performed to find out sociodemographic characteristics of the respondents. The exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) were used to test the validity of the measurement tool, and the Cronbach's Alpha coefficients were calculated to test the reliability. To find out the significance of relationships among variables, Pearson's correlation analysis was performed. Covariance Structure Analysis (CSA) was performed to test the relationship among latent factors of a model for job requirements, job resources, job burnout, and organizational effectiveness of the private security guards, and the fitness of the model analyzed with CSA was determined by the goodness-of-fit index ($x^2$, df, p, RMR, GFI, CFI, TLI, RMSEA). The level of significance was set at .05, and the following results were obtained. First, even though the effect of job requirements on job burnout was not statistically significant, it had a positive influence overall, and this result can be considered such that the higher the perception of job requirements by the member of the organization, the higher the perception of job burnout. Second, the influence of job resources on job burnout was negative, which can be considered that the higher the perception of job resources, the lower the perception of job burnout. Third, even though the influence of job requirements on organizational effectiveness was statistically nonsignificant, it had a negative influence overall, and this result can be considered that the higher the perception of job requirements, the lower the perception of organizational effectiveness. Fourth, job resources had a positive influence on organizational effectiveness, and it can be considered that the higher the perception of job resources, the higher the perception of organizational effectiveness. Fifth, the results of the analysis between job burnout and organizational effectiveness revealed that, even though the influence of job burnout on organizational effectiveness was statistically nonsignificant, it had partial negative influences on sublevels of organizational effectiveness, and this may suggest that the higher the perception of job burnout by the organization members, the lower the organizational effectiveness. Sixth, the analysis of mediating role in the relationship between job requirements and organizational effectiveness, job burnout was taking partial mediating role between job requirements and organizational effectiveness. These results suggest that reducing job burnout by managing job requirements, organizational effectiveness that leads to job satisfaction, organizational commitment, and turnover intention can be maximized. Seventh, the analysis of mediating role in the relationship among job requirements, job resources, and organizational effectiveness, job burnout was assuming a partial mediating role in the relationships among job requirements, job resources, and organizational effectiveness. These results suggest that organizational effectiveness can be maximized by either lowering job requirements or burnout management through reorganizing job resources.

  • PDF

Studies on the Virus in Silkworm Bombyx mori L. -Resistance to Virus Disease- (가잠 Virus에 관한 연구 -저항성에 관한 기초조사-)

  • 박광의;강석권
    • Journal of Sericultural and Entomological Science
    • /
    • v.9
    • /
    • pp.67-87
    • /
    • 1969
  • 1. Objectives and Importance. Many silkworms have been damaged by nuclear polyhedrosis virus diseases thoughout the country every year causing a decease in cocoon production by approximately ten per cent per year. The damage caused by the infections virus has occured in spite of complete disinfection. In this respect, it is well known it is impossible, at the present time, to protect the silkworm from these virus infections through chemical and physical control methods. Therefore, this author has attempted to solve this urgent problem from the view point of heredity and breeding, discovering the different resistances and heritabilities among 120 stains collected from throughout the country, and selecting the ones with highest resistance for the basic materials in the silkworm breeding. 2. Results of work 1) The strains with strong resistance to the nuclear polyhedrosis virus diseases are N$_4$, N$\sub$15/, N$\sub$48/, C$\sub$55/ and Em. the log ED$\sub$50/ values of them vary between 0.799 and 1.611. The susceptible strains are N$\sub$20/, C$\sub$62/, N$\sub$76/, N$\sub$79/ and C$\sub$108/, the log ED$\sub$50/ values of them vary between 5.159 and 7.258. (Reference Table 4) The Japanese strain with a log ED$\sub$50/, value of 3.770 is the strongest, followed by the Chinese strain with a log ED$\sub$50/ value of 3.564. The weakest is the European strain with a log ED$\sub$50/ value of 3.3381. The direction coefficient of the regression equation of the susceptibility varies between 0.1 and 0.6, the uniformness of the resistance of the preserved strains of this country is comparatively low. The hereditary henomena of the resistance of each strain and the conerete method of its application for silkworm breeding main the subjects for later studies. 2) The content of water and ash in silkworm has not been correlated with the capability for resistance to the virus diseases(Reference. Table 8). but it is very significantly correlated with mortality rate (in common reaning). In the case of the silkworms which have just completed the fourth moulting the content of water and ash is not related to the mortality rate. In the case of the silkworms which have just completed the third moulting, however, the water( +0.326) and ash (+0.362) registered a high significance. The ash content in the first ($\div$0.520) and second ($\div$0.386) moults is highly significant but water content in both cases is not significant (Reference Table 7). 3) The No. 205 strain proved to be the best in character among the various F$_1$ hybrids. No. 204 was very good in strength but a little lower in cocoon character than the control. No. 212 was a little low in coccon character and mortality was average, but the cocoon harvest was the best among all the varieties offered for (Reference Table 9). 4), In short, the above mentioned strains which are known to have strong resistance to the virus disease are expected to provide basic data for breeding strong varieties. It is proposed that continued research should be conducted on the characteristics of various strains for a satisfactory preservation of various characteristics.research should be conducted on the characteristics of various strains for a satisfactory preservation of various characteristics.

  • PDF

Quantitative Analysis of Carbohydrate, Protein, and Oil Contents of Korean Foods Using Near-Infrared Reflectance Spectroscopy (근적외 분광분석법을 이용한 국내 유통 식품 함유 탄수화물, 단백질 및 지방의 정량 분석)

  • Song, Lee-Seul;Kim, Young-Hak;Kim, Gi-Ppeum;Ahn, Kyung-Geun;Hwang, Young-Sun;Kang, In-Kyu;Yoon, Sung-Won;Lee, Junsoo;Shin, Ki-Yong;Lee, Woo-Young;Cho, Young Sook;Choung, Myoung-Gun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.3
    • /
    • pp.425-430
    • /
    • 2014
  • Foods contain various nutrients such as carbohydrates, protein, oil, vitamins, and minerals. Among them, carbohydrates, protein, and oil are the main constituents of foods. Usually, these constituents are analyzed by the Kjeldahl and Soxhlet method and so on. However, these analytical methods are complex, costly, and time-consuming. Thus, this study aimed to rapidly and effectively analyze carbohydrate, protein, and oil contents with near-infrared reflectance spectroscopy (NIRS). A total of 517 food samples were measured within the wavelength range of 400 to 2,500 nm. Exactly 412 food calibration samples and 162 validation samples were used for NIRS equation development and validation, respectively. In the NIRS equation of carbohydrates, the most accurate equation was obtained under 1, 4, 5, 1 (1st derivative, 4 nm gap, 5 points smoothing, and 1 point second smoothing) math treatment conditions using the weighted MSC (multiplicative scatter correction) scatter correction method with MPLS (modified partial least square) regression. In the case of protein and oil, the best equation were obtained under 2, 5, 5, 3 and 1, 1, 1, 1 conditions, respectively, using standard MSC and standard normal variate only scatter correction methods with MPLS regression. Calibrations of these NIRS equations showed a very high coefficient of determination in calibration ($R^2$: carbohydrates, 0.971; protein, 0.974; oil, 0.937) and low standard error of calibration (carbohydrates, 4.066; protein, 1.080; oil, 1.890). Optimal equation conditions were applied to a validation set of 162 samples. Validation results of these NIRS equations showed a very high coefficient of determination in prediction ($r^2$: carbohydrates, 0.987; protein, 0.970; oil, 0.947) and low standard error of prediction (carbohydrates, 2.515; protein, 1.144; oil, 1.370). Therefore, these NIRS equations can be applicable for determination of carbohydrates, proteins, and oil contents in various foods.

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF

The hydrodynamic characteristics of the canvas kite - 1. The characteristics of the rectangular, trapezoid canvas kite - (캔버스 카이트의 유체역학적 특성에 관한 연구 - 1. 사각형 캔버스 카이트의 특성 -)

  • Bae, Bong-Seong;Bae, Jae-Hyun;An, Heui-Chun;Lee, Ju-Hee;Shin, Jung-Wook
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.3
    • /
    • pp.196-205
    • /
    • 2004
  • As far as an opening device of fishing gears is concerned, applications of a kite are under development around the world. The typical examples are found in the opening device of the stow net on anchor and the buoyancy material of the trawl. While the stow net on anchor has proved its capability for the past 20 years, the trawl has not been wildly used since it has been first introduced for the commercial use only without sufficient studies and thus has revealed many drawbacks. Therefore, the fundamental hydrodynamics of the kite itself need to ne studied further. Models of plate and canvas kite were deployed in the circulating water tank for the mechanical test. For this situation lift and drag tests were performed considering a change in the shape of objects, which resulted in a different aspect ratio of rectangle and trapezoid. The results obtained from the above approaches are summarized as follows, where aspect ratio, attack angle, lift coefficient and maximum lift coefficient are denoted as A, B, $C_L$ and $C_{Lmax}$ respectively : 1. Given the rectangular plate, $C_{Lmax}$ was produced as 1.46${\sim}$1.54 with A${\leq}$1 and 40$^{\circ}$${\leq}$B${\leq}$42$^{\circ}$. And when A${\geq}$1.5 and 20$^{\circ}$${\leq}$B${\leq}$22$^{\circ}$, $C_{Lmax}$ was 10.7${\sim}$1.11. Given the rectangular canvas, $C_{Lmax}$ was 1.75${\sim}$1.91 with A${\leq}$1 and 32$^{\circ}$${\leq}$B${\leq}$40$^{\circ}$. And when A${\geq}$1.5 and 18$^{\circ}$${\leq}$B${\leq}$22$^{\circ}$, $C_{Lmax}$ was 1.24${\sim}$1.40. Given the trapezoid kite, $C_{Lmax}$ was produced as 1.65${\sim}$1.89 with A${\leq}$1.5 and 34$^{\circ}$${\leq}$B${\leq}$44$^{\circ}$. And when A=2 and B=14${\sim}$48, $C_L$ was around 1. Given the inverted trapezoid kite, $C_{Lmax}$ was 1.57${\sim}$1.74 with A${\leq}$1.5 and 24$^{\circ}$${\leq}$B${\leq}$36$^{\circ}$. And when A=2, $C_{Lmax}$ was 1.21 with B=18$^{\circ}$. 2. For a model with A=1/2, an increase in B caused an increase in $C_L$ until $C_L$ has reached the maximum. Then there was a tendency of a gradual decrease in the value of $C_L$ and in particular, the rectangular kite showed a more rapid decrease. For a model with A=2/3, the tendency of $C_L$ was similar to the case of a model with A=1/2 but the tendency was a more rapid decrease than those of the previous models. For a model with A=1, and increase in B caused an increase in $C_L$ until $C_L$ has reached the maximum. Soon after the tendency of $C_L$ decreased dramatically. For a model with A=1.5, the tendency of $C_L$ as a function of B was various. For a model with A=2, the tendency of $C_L$ as a function of B was almost the same in the rectangular and trapezoid model. There was no considerable change in the models with 20$^{\circ}$${\leq}$B${\leq}$50$^{\circ}$. 3. The tendency of kite model's $C_L$ in accordance with increase of B was increased rapidly than plate models until $C_L$ has reached the maximum. Then $C_L$ in the kite model was decreased dramatically but in the plate model was decreased gradually. The value of $C_{Lmax}$ in the kite model was higher than that of the plate model, and the kite model's attack angel at $C_{Lmax}$ was smaller than the plate model's. 4. In the relationship between aspect ratio and lift force, the attack angle which had the maximum lift coefficient was large at the small aspect ratio models, At the large aspect ratio models, the attack angle was small. 5. There was camber vertex in the position in which the fluid pressure was generated, and the rectangular & trapezoid canvas had larger value of camber vertex when the aspect ratio was high, while the inverted trapezoid canvas was versa. 6. All canvas kite had larger camber ratio when the aspect ratio was high, and the rectangular & trapezoid canvas had larger one when the attack angle was high.

Analysis of Variation for Parallel Test between Reagent Lots in in-vitro Laboratory of Nuclear Medicine Department (핵의학 체외검사실에서 시약 lot간 parallel test 시 변이 분석)

  • Chae, Hong Joo;Cheon, Jun Hong;Lee, Sun Ho;Yoo, So Yeon;Yoo, Seon Hee;Park, Ji Hye;Lim, Soo Yeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.2
    • /
    • pp.51-58
    • /
    • 2019
  • Purpose In in-vitro laboratories of nuclear medicine department, when the reagent lot or reagent lot changes Comparability test or parallel test is performed to determine whether the results between lots are reliable. The most commonly used standard domestic laboratories is to obtain %difference from the difference in results between two lots of reagents, and then many laboratories are set the standard to less than 20% at low concentrations and less than 10% at medium and high concentrations. If the range is deviated from the standard, the test is considered failed and it is repeated until the result falls within the standard range. In this study, several tests are selected that are performed in nuclear medicine in-vitro laboratories to analyze parallel test results and to establish criteria for customized percent difference for each test. Materials and Methods From January to November 2018, the result of parallel test for reagent lot change is analyzed for 7 items including thyroid-stimulating hormone (TSH), free thyroxine (FT4), carcinoembryonic antigen (CEA), CA-125, prostate-specific antigen (PSA), HBs-Ab and Insulin. The RIA-MAT 280 system which adopted the principle of IRMA is used for TSH, FT4, CEA, CA-125 and PSA. TECAN automated dispensing equipment and GAMMA-10 is used to measure insulin test. For the test of HBs-Ab, HAMILTON automated dispensing equipment and Cobra Gamma ray measuring instrument are used. Separate reagent, customized calibrator and quality control materials are used in this experiment. Results 1. TSH [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [14.8 / 4.4 / 3.7 / 0.0 ] C-2(middle concentration) [10.1 / 4.2 / 3.7 / 0.0] 2. FT4 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [10.0 / 4.2 / 3.9 / 0.0] C-2(high concentration) [9.6 / 3.3 / 3.1 / 0.0 ] 3. CA-125 [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 4.3 / 4.3 / 0.3] C-2(high concentration) [6.5 / 3.5 / 4.3 / 0.4] 4. CEA [%diffrence Max / Mean / median] (P-value by t-test > 0.05) C-1(low concentration) [9.8 / 4.2 / 3.0 / 0.0] C-2(middle concentration) [8.7 / 3.7 / 2.3 / 0.3] 5. PSA [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(low concentration) [15.4 / 7.6 / 8.2 / 0.0] C-2(middle concentration) [8.8 / 4.5 / 4.8 / 0.9] 6. HBs-Ab [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [9.6 / 3.7 / 2.7 / 0.2] C-2(high concentration) [8.9 / 4.1 / 3.6 / 0.3] 7. Insulin [%diffrence Max / Mean / Median] (P-value by t-test > 0.05) C-1(middle concentration) [8.7 / 3.1 / 2.4 / 0.9] C-2(high concentration) [8.3 / 3.2 / 1.5 / 0.1] In some low concentration measurements, the percent difference is found above 10 to nearly 15 percent in result of target value calculated at a lower concentration. In addition, when the value is measured after Standard level 6, which is the highest value of reagents in the dispensing sequence, the result would have been affected by a hook effect. Overall, there was no significant difference in lot change of quality control material (p-value>0.05). Conclusion Variations between reagent lots are not large in immunoradiometric assays. It is likely that this is due to the selection of items that have relatively high detection rate in the immunoradiometric method and several remeasurements. In most test results, the difference was less than 10 percent, which was within the standard range. TSH control level 1 and PSA control level 1, which have low concentration target value, exceeded 10 percent more than twice, but it did not result in a value that was near 20 percent. As a result, it is required to perform a longer period of observation for more homogenized average results and to obtain laboratory-specific acceptance criteria for each item. Also, it is advised to study observations considering various variables.

Current Status and Perspectives in Varietal Improvement of Rice Cultivars for High-Quality and Value-Added Products (쌀 품질 고급화 및 고부가가치화를 위한 육종현황과 전망)

  • 최해춘
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.47
    • /
    • pp.15-32
    • /
    • 2002
  • The endeavors enhancing the grain quality of high-yielding japonica rice were steadily continued during 1980s-1990s along with the self-sufficiency of rice production and the increasing demands of high-quality rices. During this time, considerably great progress and success was obtained in development of high-quality japonica cultivars and quality evaluation techniques including the elucidation of interrelationship between the physicochemical properties of rice grain and the physical or palatability components of cooked rice. In 1990s, some high-quality japonica rice cultivars and special rices adaptable for food processing such as large kernel, chalky endosperm, aromatic and colored rices were developed and its objective preference and utility was also examined by a palatability meter, rapid-visco analyzer and texture analyzer, Recently, new special rices such as extremely low-amylose dull or opaque non-glutinous endosperm mutants were developed. Also, a high-lysine rice variety was developed for higher nutritional utility. The water uptake rate and the maximum water absorption ratio showed significantly negative correlations with the K/Mg ratio and alkali digestion value(ADV) of milled rice. The rice materials showing the higher amount of hot water absorption exhibited the larger volume expansion of cooked rice. The harder rices with lower moisture content revealed the higher rate of water uptake at twenty minutes after soaking and the higher ratio of maximum water uptake under the room temperature condition. These water uptake characteristics were not associated with the protein and amylose contents of milled rice and the palatability of cooked rice. The water/rice ratio (in w/w basis) for optimum cooking was averaged to 1.52 in dry milled rices (12% wet basis) with varietal range from 1.45 to 1.61 and the expansion ratio of milled rice after proper boiling was average to 2.63(in v/v basis). The major physicochemical components of rice grain associated with the palatability of cooked rice were examined using japonica rice materials showing narrow varietal variation in grain size and shape, alkali digestibility, gel consistency, amylose and protein contents, but considerable difference in appearance and texture of cooked rice. The glossiness or gross palatability score of cooked rice were closely associated with the peak, hot paste and consistency viscosities of viscosities with year difference. The high-quality rice variety "IIpumbyeo" showed less portion of amylose on the outer layer of milled rice grain and less and slower change in iodine blue value of extracted paste during twenty minutes of boiling. This highly palatable rice also exhibited very fine net structure in outer layer and fine-spongy and well-swollen shape of gelatinized starch granules in inner layer and core of cooked rice kernel compared with the poor palatable rice through image of scanning electronic microscope. Gross sensory score of cooked rice could be estimated by multiple linear regression formula, deduced from relationship between rice quality components mentioned above and eating quality of cooked rice, with high probability of determination. The $\alpha$-amylose-iodine method was adopted for checking the varietal difference in retrogradation of cooked rice. The rice cultivars revealing the relatively slow retrogradation in aged cooked rice were IIpumbyeo, Chucheongyeo, Sasanishiki, Jinbubyeo and Koshihikari. A Tonsil-type rice, Taebaegbyeo, and a japonica cultivar, Seomjinbyeo, showed the relatively fast deterioration of cooked rice. Generally, the better rice cultivars in eating quality of cooked rice showed less retrogradation and much sponginess in cooled cooked rice. Also, the rice varieties exhibiting less retrogradation in cooled cooked rice revealed higher hot viscosity and lower cool viscosity of rice flour in amylogram. The sponginess of cooled cooked rice was closely associated with magnesium content and volume expansion of cooked rice. The hardness-changed ratio of cooked rice by cooling was negatively correlated with solids amount extracted during boiling and volume expansion of cooked rice. The major physicochemical properties of rice grain closely related to the palatability of cooked rice may be directly or indirectly associated with the retrogradation characteristics of cooked rice. The softer gel consistency and lower amylose content in milled rice revealed the higher ratio of popped rice and larger bulk density of popping. The stronger hardness of rice grain showed relatively higher ratio of popping and the more chalky or less translucent rice exhibited the lower ratio of intact popped brown rice. The potassium and magnesium contents of milled rice were negatively associated with gross score of noodle making mixed with wheat flour in half and the better rice for noodle making revealed relatively less amount of solid extraction during boiling. The more volume expansion of batters for making brown rice bread resulted the better loaf formation and more springiness in rice breed. The higher protein rices produced relatively the more moist white rice bread. The springiness of rice bread was also significantly correlated with high amylose content and hard gel consistency. The completely chalky and large grain rices showed better suitability far fermentation and brewing. The glutinous rice were classified into nine different varietal groups based on various physicochemical and structural characteristics of endosperm. There was some close associations among these grain properties and large varietal difference in suitability to various traditional food processing. Our breeding efforts on improvement of rice quality for high palatability and processing utility or value-adding products in the future should focus on not only continuous enhancement of marketing and eating qualities but also the diversification in morphological, physicochemical and nutritional characteristics of rice grain suitable for processing various value-added rice foods.ice foods.