• Title/Summary/Keyword: 기류제어

Search Result 60, Processing Time 0.024 seconds

Passive Control of the Supersonic Cavity Pressure Oscillations Using Porous Vertical Barrier (수직 다공벽을 이용한 초음속 공동 압력진동의 피동제어)

  • Kang, Min-Sung;Kwon, Joon-Kyeong;Kim, Heuy-Dong;Setoguchi, Toshiaki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.3
    • /
    • pp.27-33
    • /
    • 2009
  • A computational study has been performed out to evaluate the effect of a vertical porous barrier on the pressure oscillations in a supersonic cavity. The porous barriers with different perforations were vertically installed into a rectangular cavity at Mach numbers 1.50, 1.83 and 2.50. TVD finite difference MUSCL scheme was employed to solve the two-dimensional, unsteady, compressible Navier-Stokes equations. The present vertical porous barrier considerably altered the characteristics of the time-dependent shear layers that occur at the upstream edge of cavity and remarkably reduced the pressure oscillations inside the supersonic cavity. The present results showed that the effectiveness of passive control using the present porous vertical barrier is dependent on Mach number and the perforation of the porous barrier.

High Pressure Operation Characteristics of Pilot Scale Entrained-Bed Gasification System Using ABK Coal (ABK탄을 이용한 pilot급 분류층 석탄가스화기 시스템의 고압 운전특성)

  • Chung, Seokwoo;Yoo, Sangoh;Jung, Woohyun;Lee, Seungjong;Yun, Yongseung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.105.2-105.2
    • /
    • 2010
  • 석탄의 직접 연소 대신 고온/고압의 조건에서 불완전연소 및 가스화 반응을 통하여 일산화탄소(CO)와 수소($H_2$)가 주성분인 합성가스를 제조하여 이용하는 석탄 가스화 기술은 현실적인 에너지원의 확보를 위한 방법인 동시에 이산화탄소를 저감할 수 있는 기술이라 할 수 있다. 따라서, 본 연구에서는 non-slagging 방식의 pilot급 분류층 석탄가스화기를 대상으로 고압 미분탄공급장치, 합성가스 냉각장치, 고온 집진장치 등을 연계하여 상용급 석탄가스기와 유사한 $1,300^{\circ}C$, 20 kg/$cm^2$의 운전조건에서 미분탄의 안정적인 공급을 통한 양질의 합성가스 제조 및 제조된 합성가스의 분기 공급특성 시험을 진행하였다. 그리고, 고압 미분탄공급장치는 공급호퍼에 저장된 미분탄을 고온/고압 조건으로 운전되는 석탄가스화기에 공급하기 위한 설비로서, 이러한 고압 미분탄공급장치를 이용한 기류수송 방식의 미분탄 공급 기술은 가스화기 설계 및 운전제어 기술과 더불어 석탄가스화기 시스템의 안정적 연속운전을 위한 가장 핵심적인 기술 중 하나라고 할 수 있다. 따라서, 본 연구에서는 아역청탄인 인도네시아 ABK탄을 대상으로 향후 dense phase 고압 기류수송을 목적으로 하는 고압 미분탄공급장치의 성능특성을 시험을 진행하였는데, 시험 결과 73 kg/h 조건에서 20 kg/$cm^2$의 가스화기에 대한 안정적인 미분탄 공급특성을 확인할 수 있었으며, 이러한 미분탄 공급 조건에서 CO 40~45%, $H_2$ 16~20%, $CO_2$ 5~8% 조성의 양질의 합성가스를 평균적으로 $230{\sim}50Nm^3/h$ 안정적으로 제조할 수 있었다.

  • PDF

Numerical Study for Flow Uniformity in Selective Catalytic Reduction (SCR) (SCR 반응기 유동 균일화를 위한 수치적 연구)

  • Jung, Yu-Jin;Hong, Sung-Gil;Lee, Gang-Woo;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.151-154
    • /
    • 2011
  • $NO_x$ 제어 기술로는 크게 연소 전 탈질, 연소 개선 및 연소 후 탈질 기술로 구분할 수 있으며, 연소 후 탈질 기술에 속하는 SCR은 촉매를 사용하여 $NO_x$를 환원하는 대표적인 배연탈질기술이다. SCR의 $NO_x$ 저감 성능은 촉매 요인(촉매 구성물질, 형태, 공간속도 등)과 배가스의 온도, 유속 분포, 공정 운전 조건 등의 다양한 인자에 의해 좌우되는데 특히, 촉매층으로 유입되는 유동의 균일도는 가장 중요한 요소가 된다. 유동이 균일하지 않을 경우 촉매 전단에 편류가 발생하게 될 것이며 일정 촉매만 사용하게 되어 촉매 사용주기 감소 및 SCR 성능 저하를 초래할 수 있기 때문이다. 본 연구에서는 3차원 수치 해석 기법을 이용하여 설계 초기의 SCR 반응기 내 유동 특성을 모사하여 기류 균일도 여부를 확인하고, SCR 내 유동 균일도를 최적화시키기 위한 설계를 목적으로 설치하는 가이드 베인과 배플, 다공판이 반응기 내부 유동 및 촉매층의 기류 균일도에 미치는 영향에 대하여 연구를 수행하였다. 그 결과, 유동 개선을 위해 인입 덕트 곡관부에 가이드 베인을 설치하여 처리가스를 적절하게 배분시키고, 반응기 상단에 3단 배플을 설치한 결과 반응기 내부 유동의 편류 개선에 매우 효과적임을 알 수 있었다. 또한 다공판을 예비 촉매층 하단부 위치에 추가로 설치함에 따라 유동을 한번 더 완충시킬 수 있어 기류 균일도가 매우 양호해짐을 알 수 있었다.

  • PDF

Effect of Photoperiod on the Evapotranspiration and Graft-taking of Grafted Seedlings (접목묘의 증발산과 활착에 미치는 광주기의 영향)

  • 김용현;박현수
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.23-26
    • /
    • 2000
  • 인공광하에서 접목묘의 활착을 촉진시키려면 접목묘에 대한 최적 활착조건이 제시되어야 하나, 이에 관한 연구는 최근에 이루어지고 있다. 접목묘의 활착 단계에서 접수의 위조를 방지하면서 활착율을 높이려면, 접목 직후 접목묘로부터의 증발산을 억제하는 것이 요구된다. 이 가운데 기온, 상대습도, 기류속도, 광환경의 제어가 가능한 폐쇄형 활착실과 접목묘의 증발산속도 계측 시스템이 개발되었으며(Kim, 2000a; Kim과 Park, 2000a), 접목묘의 증발산과 활착 특성에 미치는 기온, 상대습도 및 광항성유효광량자속의 효과가 보고되었다(Kim, 2000b; Kim과 Park, 2000a) (중략)

  • PDF

Analysis of New Air Control System in Clean Stocker(II) (Clean Stocker내 새로운 방식의 기류제어에 관한 연구(II))

  • Choi, Gi-Han;Han, Chang-Woo;Lee, Sang-Ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1178-1186
    • /
    • 2002
  • Clean stockers are being used by semiconductor and TFT-LCD manufacturers to store and buffer work in process. The only way to keep the stored product clean is to provide constant clean airflow the product and through stocker. Up to now, stockers typically have been configured to receive their laminar airflow from fan filter units that are located on the side of the stocker. This type of stocker may have such problems as complexity of structure, increment of temperature, mechanical vibration, initial investment and running cost. In this study, in order to solve the above mentioned problems, new air control system in stocker is proposed, which is to control open ratios of exits that are located on the side of the stocker without fan filter units. In this study, static pressure regain was used for the analysis of the open ratios of exits theoretically and experiment was also conducted using actual clean stocker for TFT-LCD manufacturers and CFDesign, was used for simulating airflow in stocker. As a result, open ratios of exits can be obtained by the analysis of static pressure regain and was verified by experiment and simulation results. Therefore, new air control system in stocker can be used by the semiconductor and TFT-LCD manufacturers.

A real scale test on performance of water spray systems in tunnel fire (터널화재시 물분무소화설비의 성능에 대한 실대시험)

  • Park, Kyung-Hwan;So, Soo-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.4
    • /
    • pp.341-347
    • /
    • 2010
  • The performance of water spray system installed to reduce risks of tunnel fire is investigated by a real tunnel fire test. In case of A class fire, Pool fire, and car fire, the nozzle of water spray has had a marvelous effect to reduce the temperature of hot smoke. And it is verified to have remarkable cooling effects when there is the air flow in a tunnel. Though this results, water spray system will be able to prevent a fire jump to decrease the air temperature in a tunnel and to protect tunnel facilities by the fire control.

Design to Control Vibration for Stay Cable with Damper (댐퍼도입에 의한 사장 케이블의 제진설계)

  • Kim, Hyeon Kyeom;Hwang, Jae Woong;Lee, Myeong Jae;Seo, Ju Won
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1A
    • /
    • pp.51-58
    • /
    • 2008
  • A cable element happens to vibration easily rather than other elements because a cable element has few rotational stiffness. Dynamic motion of stay cable is distinguished from vibration by wind and/or rain and excitation by support movement. Mostly a stay cable is vibrated by wind and/or rain except that when natural periods coincide between stiffening girder and stay cable. It happens to deterioration of serviceability and durability by vortex shedding, rainy-wind induced vibration, and galloping. Additional damping generated by installation of cable damper is well known good scheme against above phenomena. Researchers have lack of effort to develop the recommendations even if cable stayed bridges are designed and constructed in Korea. Therefore, development of the domestic recommendations should be achieved as soon as possible. This study suggests the consistent and systematic recommendations on vibration controlling design of stay cable by installation of damper. It gives readers two important methodologies that one evaluates required damping ratio, the other determines installing point considering efficiency.

Effects of Mach Number on the Control of Supersonic Cavity Pressure Oscillations (초음속 공동내부의 압력진동 제어에 미치는 기류 마하수의 영향)

  • Shin, Choon-Sik;Suryan, Abhilash;Kim, Heuy-Dong
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.119-122
    • /
    • 2009
  • Numerical computations were carried out to analyze the effect of inlet Mach number and sub-cavity on the control of cavity-induced pressure oscillations in two-dimensional supersonic flow. A passive control method wherein a sub-cavity was introduced on the front wall of a square cavity was studied for Mach numbers 1.50, 1.83 and 2.50. The results showed that sub-cavity is effective in reducing the oscillations at different inlet Mach numbers. The resultant amount of attenuation of pressure oscillations depended on the inlet Mach number, length of the flat plate, and the depth of the sub-cavity used as an oscillation suppressor.

  • PDF

A study on the smoke control performance of the damper exhaust system at FCEV fire in tunnel for small vehicles (소형차 전용터널 내 수소연료전지차 화재시 집중배기방식의 제연성능에 관한 연구)

  • Hong, Seo-Hee;Baek, Doo-San
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.745-756
    • /
    • 2022
  • The road tunnel is a semi-closed space that is blocked on all sides except the entrance and exit, and in the event of a fire, the smoke of the fire spreads longitudinally due to heat buoyancy caused by the fire and air currents that always exist in the tunnel. To solve this problem, smoke removal facilities are installed in road tunnels to secure a safe evacuation environment by controlling the direction of movement of smoke or directly smoking at fire points. In urban areas, the service level of urban roads decreases due to the increase in traffic due to the increase in population, and as a solution, the construction of underground roads in urban areas is increasing. When a fire occurs during hydrogen leakage through TPRD of a hydrogen fuel cell vehicle (FCEV), the fire intensity depends on the amount of leakage, and the maximum fire intensity depends on the orifice diameter of the TPRD. Considering the TPRD orifice diameter of 1.8 mm, this study analyzed the diffusion distance of fire smoke according to the wind speed of the roadway and the opening interval of the large exhaust port when the maximum fire intensity was 15 MW. As a result, it was analyzed that air flow in the tunnel could be controlled if the wind speed of the road in the tunnel was less than 1.25 m/s, and smoke could be controlled within 200 m from the fire if the damper interval was 50 m and 100 m.

A Study on Reducing Method for Stack effect in High-rise Building (고층 건축물 연돌효과 저감 방법에 대한 연구)

  • Kim, Jin-Soo
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.252-257
    • /
    • 2011
  • 고층 건물에서 혹한기에 심하게 발생하는 연돌효과는 건물 외벽 및 창문에 구조적 영향을 미치고, 제연기능을 기능을 저해하고, 승강기 문 개폐 장애와 소음 및 공조기능 장애 등 설비 기능에 부정적 영향을 미치며, 화재시 승강기 승강로 등 수직 샤프트를 통해 연기를 전파시킨다. 계단실의 상하부를 화재 시 자동으로 개방함으로써 계단실의 기류 유동 마찰을 이용하여 연돌효과를 대폭 줄일 수 있고, 승강기 승강로 또한 상하부를 개방함으로써 승강로와 거실 사이의 차압을 줄여서 연기의 전파를 막을 수 있다. 샤프트 복합효과를 이용하여 차압을 상당부분 제어할 수 있으며, 일반용 샤프트만으로 샤프트 복합효과를 일으키기에 부족한 경우에는 연돌효과 제어 전용 보조 샤프트를 검토할 필요가 있다.

  • PDF