• Title/Summary/Keyword: 기능성 재료

Search Result 1,038, Processing Time 0.041 seconds

Application of MicroPACS Using the Open Source (Open Source를 이용한 MicroPACS의 구성과 활용)

  • You, Yeon-Wook;Kim, Yong-Keun;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Tae-Sung;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: Recently, most hospitals are introducing the PACS system and use of the system continues to expand. But small-scaled PACS called MicroPACS has already been in use through open source programs. The aim of this study is to prove utility of operating a MicroPACS, as a substitute back-up device for conventional storage media like CDs and DVDs, in addition to the full-PACS already in use. This study contains the way of setting up a MicroPACS with open source programs and assessment of its storage capability, stability, compatibility and performance of operations such as "retrieve", "query". Materials and Methods: 1. To start with, we searched open source software to correspond with the following standards to establish MicroPACS, (1) It must be available in Windows Operating System. (2) It must be free ware. (3) It must be compatible with PET/CT scanner. (4) It must be easy to use. (5) It must not be limited of storage capacity. (6) It must have DICOM supporting. 2. (1) To evaluate availability of data storage, we compared the time spent to back up data in the open source software with the optical discs (CDs and DVD-RAMs), and we also compared the time needed to retrieve data with the system and with optical discs respectively. (2) To estimate work efficiency, we measured the time spent to find data in CDs, DVD-RAMs and MicroPACS. 7 technologists participated in this study. 3. In order to evaluate stability of the software, we examined whether there is a data loss during the system is maintained for a year. Comparison object; How many errors occurred in randomly selected data of 500 CDs. Result: 1. We chose the Conquest DICOM Server among 11 open source software used MySQL as a database management system. 2. (1) Comparison of back up and retrieval time (min) showed the result of the following: DVD-RAM (5.13,2.26)/Conquest DICOM Server (1.49,1.19) by GE DSTE (p<0.001), CD (6.12,3.61)/Conquest (0.82,2.23) by GE DLS (p<0.001), CD (5.88,3.25)/Conquest (1.05,2.06) by SIEMENS. (2) The wasted time (sec) to find some data is as follows: CD ($156{\pm}46$), DVD-RAM ($115{\pm}21$) and Conquest DICOM Server ($13{\pm}6$). 3. There was no data loss (0%) for a year and it was stored 12741 PET/CT studies in 1.81 TB memory. In case of CDs, On the other hand, 14 errors among 500 CDs (2.8%) is generated. Conclusions: We found that MicroPACS could be set up with the open source software and its performance was excellent. The system built with open source proved more efficient and more robust than back-up process using CDs or DVD-RAMs. We believe that the operation of the MicroPACS would be effective data storage device as long as its operators develop and systematize it.

  • PDF

Clinical Analysis to the Early Results of the CABG (관상동맥우회술의 조기 성적에 대한 임상적 고찰)

  • Kim, Dae-Sig;Yang, Jin-Young;Koo, Won-Mo;Moon, Seung-Chul;Lee, Gun;Lee, Hyeon-Jae;Lim, Chang-Young
    • Journal of Chest Surgery
    • /
    • v.31 no.11
    • /
    • pp.1043-1048
    • /
    • 1998
  • Background: As coronary arterial disease is increasing, we evaluated the patients who underwent CABG(Coronary Artery Bypass Grafting) and thus report the early results and risk factors related to mortality and morbidity. Materials and methods: Between July 1996 and February 1998, 42 patients underwent CABG. We analyzed age, sex, preoperative ejection fraction, Canadian heart classification, prevalence factors of CAD(Coronary Artery Disease), angiographic findings, graft vessel numbers, IMA(Internal Mallary Artery) use, ECC* (extracorporeal circulation) time and morbidity. We also evaluated the mortality rate and the causes of death. Results: Complication was developed at 17cases. The average age of the complication group was 61±11.9 years and that of the noncomplication group was 51±10.5 years(p=0.004). ECC time was 198±42.5(min) in the complication group and 158±47.4(min) in the noncomplication group(p=0.008). The other factors had no correlation to the morbidity, statistically. The average follow up duration was 12.5 months and all the patients were alive except for the 2 expired cases. The mortality rate was 4.7%, among which one patient who underwent CABG with aortic valve replacement died due to multiorgan failure and the other died due to sepsis with pneumonia and wound infection. Conclusions: We conclude that the risk factors related to morbidity were age and ECC time, and that there were no correlations between other factors and morbidity.

  • PDF

A Study on the Effect of the Changes of Play Facilities on Rules Changes - Focusing on the City of Seoul - (관련법규 변천이 아파트단지 내 어린이놀이터 변화에 미치는 영향 연구 - 서울시 소재 현장을 중심으로 -)

  • Kim, Dong-Chan;Suh, Joo-Hwan;Park, You-Jeong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.37 no.2
    • /
    • pp.26-35
    • /
    • 2009
  • This study is an analysis of the design changes of children's play facilities and the related rules and regulations which causes these changes. Accordingly, it is noticed that a site's change of design by legislation and by yearly alternation influences playground design. First, after revising the provisions for the distance from roads and parking lots, the constructing of safety fences between play facilities and the using of durable materials, alterations of the designs have been made a reality. Second, the design changes after the period of regulation transitions were caused by provisions related to the shelter of evergreens and conditions of the sun. Third, the changes of the playgrounds were related to the substitution of exercise facilities for the local residents and in carrying out a hygiene exam more than twice a year. Because a lack of regulatory standards for the design of playgrounds resulted in compliance based on individual interpretation and because a substitution of exercise facilities is part of the way to alleviate these regulations, the conditions of the site under investigation could be projeced. By such changes of regulations and analysis of alterations of playground design, programs for improvement were suggested. It turned out that the composition of the concrete standard in conformity with regulations required closer observance. Moreover, design standards for children's playgrounds are needed, such as the provision of variation in external appearance, the creation of more flexible layouts and the outlining of spaces by themes.

Chemo-Mechanical Analysis of Bifunctional Linear DGEBA/Linear Amine (DDM, DDS) Resin Casting Systems (DGEBA/방향족 아민(DDM, DDS) 경화제의 벤젠링 사이의 관능기 변화가 물성 변화에 미치는 영향에 대한 연구)

  • 명인호;정인재;이재락
    • Composites Research
    • /
    • v.12 no.4
    • /
    • pp.71-78
    • /
    • 1999
  • To determine the effect of chemical structure of linear amine curing agents on thermal and mechanical properties, standard epoxy resin DGEBA was cured with diaminodiphenyl methane (DDM), diaminodiphenyl sulphone (DDS) in a stoichiometrically equivalent ratio. From this work, the effect of aromatic amine curing agents. In contrast, the results show that the DGEBA/DDS cure system having the sulfone structure between the benzene rings had higher values in the conversion of epoxide, density, shrinkage (%), glass transition temperature, tensile modulus and strength, flexural modulus and strength than the DGEBA/DDM cure system having methylene structure between the benzene rings, whereas the DGEBA/DDM cure system presented higher values in the maximum exothermic temperature, thermal expansion coefficient, and thermal stability. These results are caused by the relative effects of sulfone group having strong electronegativity and methylene group having (+) repulsive property and stem from the effect of the conversion ratio of epoxide group. The result of fractography shows that the each grain size of the DDM/DGEBA system with feather-like structure is larger than that of the DDS/DGEBA system.

  • PDF

Mechanism and Spray Characteristics of a Mini-Sprinkler with Downward Spray for Prevention of Drop Water (하향 분사식 미니스프링클러의 낙수방지 메카니즘과 살수 특성)

  • Kim, Hong-Gyoo;Chung, Sung-Won
    • Journal of Bio-Environment Control
    • /
    • v.16 no.3
    • /
    • pp.210-216
    • /
    • 2007
  • A study was conducted to find mechanism and spray characteristics of a mini-sprinkler with downward spray to develop a new design type to be able to prevent drop water. The experiments were executed in a plastic greenhouse to minimize the effect of the wind. Data was collected at five different operation pressures and at 4 different raiser heights. Spray characteristics of the sprinkler such as effective radius, effective area, mean application depth, absolute maximum application depth, effective maximum application depth and coefficient of variation were determined. In order to analyze the mechanism and packing supporter of sprinkler, the numerical simulation using ABAQUS was performed. The optimum pressure for preventing drop water was determined.

Transmission Dose Estimation Algorithm for Tissue Deficit (조직 결손에 대한 투과선량 계산 알고리즘 보정)

  • Yun Hyong Geun;Chie Eui Kyu;Huh Soon Nyung;Lee Hyoung Koo;Woo Hong Gyun;Shin Kyo Chul;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.20 no.2
    • /
    • pp.186-192
    • /
    • 2002
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry. In this study, previous algorithm for estimation of transmission dose was modified for use in cases with tissue deficit. Materials and Methods : The beam data was measured with flat solid phantom in various conditions of tissue deficit. New algorithm for correction of transmission dose for tissue deficit was developed by physical reasoning. The algorithm was tested in experimental settings with irregular contours mimicking breast cancer patients using multiple sheets of solid phantoms. Results : The correction algorithm for tissue deficit could accurately reflect the effect of tissue deficit with errors within ${\pm}1.0\%$ in most situations and within ${\pm}3.0\%$ in experimental settings with irregular contours mimicking breast cancer treatment set-up. Conclusion : Developed algorithm could accurately reflect the effect of tissue deficit and irregularly shaped body contour on transmission dosimetry.

Feed Value, Growth and Dry Matter Yield of High Yielding Rice(Oryza sativa L.) for the Twice-cutting System (2회 예취 재배법을 이용한 초다수 벼(Oryza sativa L.) 계통의 생육·수량 및 사료가치 평가)

  • 백진수;이점호;정오영;홍하철;이규성;진일두;이상복;최용환;양창인;김종근;김병완;김홍열;양세준;이영태
    • Journal of Animal Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.443-452
    • /
    • 2006
  • The four rice(Oryza sativa L.) lines, previously demonstrated to have vigorous herbage production at the vegetative growth stage, were investigated for their growth traits, dry matter yield and feed value using the twice-cutting system that 1st-cut is harvested at panicle formation stage and 2nd-cut at the yellow ripen stage. The twice-cutting system is regarded as an effective method in the production of forage rice by escaping lodging and insect damages caused by the overgrowth and typhoon around the heading stage.The feed value of the twice-cut rice plant of there lines were compared with the control of normal, cutting at the yellow ripen stage. The relative feed value(RFV), the total digestible nutrient(TDN) and the crude protein(CP) content of the twice-cut straw were higher the control in every lines. However, the dry matter yield (DMY), represented by the summed forage production of 1st and 2nd cut-rice plant, were lower the control, and the DMY of straws were increase but grains were decrease for twice-cutting system. In addition, TDN yield showed the similar tendency with DMY.Recently, as one of the breeding aims the researches for improving the digestibility of rice straw have been required. In this regard, twice-cutting system is recognized with the fact that it has the effect which raises the digestibility of the straw. Especially, the 2nd cut of IR73111-B-R-15-3-1 line was similar to the control at the TDN yield of straw, and would be used as a breeding material for product the roughage of good quality.

Facile Fabrication of Animal-Specific Positioning Molds For Multi-modality Molecular Imaging (다중 분자 영상을 위한 간편한 동물 특이적 자세 고정틀의 제작)

  • Park, Jeong-Chan;Oh, Ji-Eun;Woo, Seung-Tae;Kwak, Won-Jung;Lee, Jeong-Eun;Kim, Kyeong-Min;An, Gwang-Il;Choi, Tae-Hyun;Cheon, Gi-Jeong;Chang, Young-Min;Lee, Sang-Woo;Ahn, Byeong-Cheol;Lee, Jae-Tae;Yoo, Jeong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.401-409
    • /
    • 2008
  • Purpose: Recently multi-modal imaging system has become widely adopted in molecular imaging. We tried to fabricate animal-specific positioning molds for PET/MR fusion imaging using easily available molding clay and rapid foam. The animal-specific positioning molds provide immobilization and reproducible positioning of small animal. Herein, we have compared fiber-based molding clay with rapid foam in fabricating the molds of experimental animal. Materials and Methods: The round bottomed-acrylic frame, which fitted into microPET gantry, was prepared at first. The experimental mice was anesthetized and placed on the mold for positioning. Rapid foam and fiber-based clay were used to fabricate the mold. In case of both rapid foam and the clay, the experimental animal needs to be pushed down smoothly into the mold for positioning. However, after the mouse was removed, the fabricated clay needed to be dried completely at $60^{\circ}C$ in oven overnight for hardening. Four sealed pipet tips containing $[^{18}F]FDG$ solution were used as fiduciary markers. After injection of $[^{18}F]FDG$ via tail vein, microPET scanning was performed. Successively, MRI scanning was followed in the same animal. Results: Animal-specific positioning molds were fabricated using rapid foam and fiber-based molding clay for multimodality imaging. Functional and anatomical images were obtained with microPET and MRI, respectively. The fused PET/MR images were obtained using freely available AMIDE program. Conclusion: Animal-specific molds were successfully prepared using easily available rapid foam, molding clay and disposable pipet tips. Thanks to animal-specific molds, fusion images of PET and MR were co-registered with negligible misalignment.

TOOTH MOVEMENTS TO THE SITE OF ALVEOLAR BONE GRAFT (구순구개열 환아에서의 치조골이식)

  • Cho, Hae-Sung;Park, Jae-Hong;Kim, Gwang-Chul;Choi, Seong-Chul;Lee, Keung-Ho;Choi, Yeung-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.140-149
    • /
    • 2007
  • Cleft lip and palate are congenital craniofacial malformation. Reconstruction of dental arch in patient with alveolo-palatal clefts is very important, because they have many problems in functions and esthetics. Malnutrition, poor oral hygiene, respiratory infections, speech malfunctions, maxillofacial deformity, and psychological problems may be occured without proper treatment during the long period of management of the cleft lip and palate. So the treatment should be managed with a multidisciplinary approach. Bone grafting is a consequential step in the dental rehabilitation of the cleft lip and palate patient A complete alveolar arch should be achieyed of the teeth to erupt in and to form a stable dentition. And the presence of the cleft complicate the orthodontic treatment. Therefore bone grafting in patients with cleft lip and palate is a widely adopted surgical procedure. Grafted bone stabilizes the alveolar process and allows the canine or incisor to move into the graft site. After the bone grafting, orthodontic closure of the maxillary arch has become a common practice for achieving dental reconstruction without any prosthodontic treatment. Various grafting materials have been used in alveolar clefts. Iliac bone is most widely fovoured, but tibia, rib, cranial bone, mandible have also been used. And according to its time of occurrence, the bone graft may be divided into primary, early secondary, secondary, late secondary. Bone grafting is called secondary when performed later, at the end of the mixed dentition. It is the most accepted procedure and has become part of treatment of protocol A secondary bone graft is performed preferably before the eruption of the permanent canine in order to provide adequate periodontal support for the eruption and preservation of the teeth adjacent to the cleft. In this report, we report here on a patient with unilateral cleft lip and palate, who underwent iliac bone graft. The cleft was fully obliterated by grafted bone in the region of the alveolar process. The presence of bone permitted physiologic tooth movement and the orthodontic movement of adjacent tooth into the former cleft area. Satisfactory arch alignment could be achieved in by subsequent orthodontic treatment.

  • PDF

Comparison of chewing ability and quality of life before and after the dental implantation (임플란트 시술환자의 시술 전.후의 저작능력과 삶의 질 비교)

  • Kim, Kyeong-Won;Lee, Kyeong-Soo;Kang, Pock-Soo;Kim, Woo-Shik;Lee, Hee-Kyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.215-221
    • /
    • 2009
  • Statement of problem: Recently the populations of patients receiving implant surgery are greatly increase for maintaining oral health. Purpose: This study was conducted for implanted patients to assess the chewing ability patient satisfaction level and changes in quality of life before and after the implant surgery. Material and methods: The current study subjected 109 adult patients, older than 20 years of age, who received implant surgery from December, 2006 to October, 2007 at the 6 dental clinics located at Daegu and Ulsan metropolitan cities. Twice of surveys were conducted for the patients before and after receiving the dental implant surgery. Results: As the motivation of receiving implant surgery, 45.9% of the patients selected the surgery for the chance o "f chewing function recovery", and " failure of treatment and complications" was found to be the most worrisome at the time of surgery by recording 38.5%.The satisfaction level before the implant surgery scored 30.37, while the score was increased to 45.01 after the surgery by showing a significant difference before and after receiving the surgery(P<.001). Regard on the surgery, 91.8% of the patients responded as "Satisfy", and 89% of the study subjects responded that they have willingness to recommend the surgery to their families and friends. The chewing ability score measured by using the surveys on edible foods, the score before the surgery was 15.24, while the score was increased to 19.11 after the surgery by showing a significant difference before and after receiving the surgery(P<.001). The quality of life score was also found to be increased to 11.17 after the surgery from 9.99 before the surgery by showing a significant difference(P<.001). Conclusion: In a future, the studies on the numbers of implanted loss teeth and the location of tooth loss are necessary, more long-term follow study are needed, and it is thought to be necessary to enlarge the sample size of subjects in conducting the studies.