• Title/Summary/Keyword: 기계인간

Search Result 58,810, Processing Time 0.078 seconds

Analysis of Fluidization in a Fluidized Bed External Heat Exchanger using Barracuda Simulation (바라쿠다 시뮬레이션을 이용한 유동층 외부 열교환기의 유동해석)

  • Lee, Jongmin;Kim, Dongwon;Park, Kyoungil;Lee, Gyuhwa
    • Korean Chemical Engineering Research
    • /
    • v.58 no.4
    • /
    • pp.642-650
    • /
    • 2020
  • In general, the circulation path of the fluidized particles in a CFB (Circulating Fluidized Bed) boiler is such that the particles entrained from a combustor are collected by a cyclone and recirculated to the combustor via a sealpot which is one of non-mechanical valves. However, when a fluidized bed heat exchanger (FBHE) is installed to additionally absorb heat from the fluidized particles, some particles in the sealpot pass through the FBHE and then flow into the combustor. At this time, in the FBHE operated in the bubbling fluidization regime, if the heat flow is not evenly distributed by poor mixing of the hot particles (800~950 ℃) flowing in from the sealpot, the heat exchanger tubes would be locally heated and then damaged, and the agglomeration of particles could also occur by formation of hot spot. This may affect the stable operation of the circulating fluidized bed. In this study, the unevenness of heat flow arising from structural problems of the FBHE of the domestic D-CFB boiler was found through the operating data analysis and the CPFD (Computational Particle Fluid Dynamics) simulation using Barracuda VR. Actually, the temperature of the heat exchanger tubes in the FBHE showed the closest correlation with the change in particle temperature of the sealpot. It was also found that the non-uniformity of the heat flow was caused by channeling of hot particles flowing in from the sealpot. However, it was difficult to eliminate the non-uniformity even though the fluidizing velocity of the FBHE was increased enough to fluidize hot particles vigorously. When the premixing zone for hot particles flowing in from the sealpot is installed and when the structure is changed through the symmetrization of the FBHE discharge line for particles reflowing into the combustor, the particle mixing and the uniformity of heat flow were found to be increased considerably. Therefore, it could be suggested that the structural modification of the FBHE, related to premixing and symmetric flow of hot particles, is an alternative to reduce the non-uniformity of the heat flow and to minimize the poor particle mixing.

An Evaluation of the Private Security Industry Regulations in Queensland : A Critique (호주 민간시큐리티 산업의 비판적 고찰 : 퀸즐랜드주를 중심으로)

  • Kim, Dae-Woon;Jung, Yook-Sang
    • Korean Security Journal
    • /
    • no.44
    • /
    • pp.7-35
    • /
    • 2015
  • The objective of this article is to inform and document the contemporary development of the private security industry in Queensland Australia, a premier holiday destination that provide entertainment for the larger region. The purpose of this review is to examine the comtemporary development of mandated licensing regimes regulating the industry, and the necessary reform agenda. The overall aim is threefold: first, to chart the main outcomes of the two-wave of reforms since the mid-'90s; second, to examine the effectiveness of changes in modes of regulation; and third, to identify the criteria that can be considered a best practice based on Button(2012) and Prenzler and Sarre's(2014) criteria. The survey of the Queensland regulatory regime has demonstrated that, despite the federal-guided reforms, there remain key areas where further initiatives remain pending, markedly case-by-case utilisation of more proactive strategies such as on-site alcohol/drug testing, psychological evaluations, and checks on close associates; lack of binding training arrangement for technical services providers; and targeted auditing of licensed premises and the vicinity of venues by the Office of Fair Trading, a licensing authority. The study has highlighted the need for more determined responses and active engagements in these priority areas. This study of the development of the licensing regimes in Queensland Australia provides useful insights for other jurisdictions including South Korea on how to better manage licensing system, including the measures required to assure an adequate level of professional competence in the industry. It should be noted that implementing a consistency in delivery mode and assessment in training was the strategic imperative for the Australian authority to intervene in the industry as part of stimulating police-private partnerships. Of particular note, competency elements have conventionally been given a low priority in South Korea, as exemplified through the lack of government-sponsored certificate; this is an area South Korean policymakers must assume an active role in implementing accredited scheme, via consulting transnational templates, including Australian qualifications framework.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010 (설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Lee, Dae-Young;Kim, Seo-Young;Choi, Jong-Min;Kim, Su-Min;Kwon, Young-Chul;Baik, Yong-Kyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.6
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

An Histopathological Investigation on the Resistant Tong-Il Cultivar by Inoculating Rice Blast Fungus, Pyricularia oryzae Cav. (수도(水稻) 도열병(稻熱病)에 저항성(抵抗性)인 통일품종(統一品種)에 대한 침입생리(侵入生理)에 관(關)한 연구(硏究))

  • Chung, Bong-Koo;Kim, Kwang-Suk
    • The Korean Journal of Mycology
    • /
    • v.5 no.1
    • /
    • pp.13-19
    • /
    • 1977
  • In order to investigate histopathologically the nature of varietal resistance and infection process of the rice bast fungus, Pyricularia oryzae. this experiment was undertaken by using the resistant cultivar Tongil and susceptible cultivars Norin No.6 and Jinheung in 1973 to 1974. 1) It was found that appressorium of the fungus forms not only at 4 hours after incubation under the favorable conditions but also peak of appressorial formation is at 48 hours treatment. Physical stimulus known to be a definite factor for appressorial formation. The optimum temperature range for appressorial infection was at $24^{\circ}C$ to $28^{\circ}C$, and pH was between 4.8 to 8.0 with 6.8 as the optimum. 2) Although percent of appressorial formation on the leaves of resistant Tongil and susceptiible Norin No.6 were only slightly different, there was a remarkable difference between resistant and susceptible cultivars with regard to percent of hyphal infection and index for hyphal extension. Index of hyphal extension was 1.6-2.7 in Tonyil. while in susceptible cultivar was 3.4-6.6. The rate of discoloration of infected cells, a indication of hypersensitivity, was greater in the resistant than in susceptible cultvar. 3) Therefore, it could be concluded that resistance of Tongil cultivar may be attributable to a higher degree of mechanical barriers as well as a higher level of antifungal substance accumulation.

  • PDF

Anticoagulation Management after Mitral Valve Replacement with the St. Jude Medical Prosthesis (승모판치환 환자의 항응혈제 치료)

  • 김종환;김영태
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1172-1182
    • /
    • 1998
  • Background: Primary goal of anticoagulation treatment in patients with mechanical heart valve is the effective prevention of thromboembolism and safe avoidance of bleeding as well. Material and Method: Two-hundred and nine patients with the St. Jude Medical prosthesis operated on between 1984 and 1995, for mitral(MVR 122), aortic(AVR 39) and double mitral and aortic valve replacement(DVR 48) respectively, were studied on the practically achieved levels of anticoagulation and the clinical outcomes. Patients were on Coumadin and followed up by monthly visit to outpatient clinic for examination and prothrombin time measurement to adjust the International Normalized Ratios(INRs) within the low-intensity target range between 1.5 and 2.5. Result: A total anticoagulation follow-up period was 1082.0 patient- years(mean 62.1 months) and INRs of 10,205 measurements were available for evaluation. The accomplished INRs among the replacement groups were not significantly different and only 65% of INRs were within the target range. And, in individual patients, only 37% of patients had INRs included within the target range in more than 70% of tests during follow-up period. The levels of INRs in patients with atrial fibrillation, which was found in 57% of patients, were definitely higher than the ones measured in patients with regular rhythm(p<0.001). Thromboembolisms were experienced by 15 patients with the incidence of 1.265%/patient- year(MVR 1.412%, AVR 0.462% and DVR 1.531%/patient-year) and major bleeding by 4 patients with the incidence of 0.337%/patient-year(MVR 0.424%, AVR none and DVR 0.383%/patient-year). Frequent as well as prolonged missing of prothrombin time tests was the main risk factor strongly associated with the thromboembolic complications(odds ratio 1.99). The proportion of INRs within target range of less than 60% in individual patient was the highly significant risk factor of both thromboembolic and overall embolic and bleeding complications(p<0.004 and p<0.002 respectively). Conclusion: In conclusion, the low-intensity therapeutic target range of INRs was adequate in patients with AVR and in sinus rhythm. However, the patients with replacement of the mitral valve were more likely to require higher target range of INRs, especially in the presence of atrial fibrillation, to achieve the practical levels of anticoagulation enough to prevent thromboembolic complications effectively. For the higher therapeutic target range of INRs between 2.0∼3.0, further accumulation of clinical evidences are required. It is highly desirable to improve the patients' compliance under continuous instructions in visiting outpatient clinic and in taking daily Coumadin without omission and to keep INRs consistently within optimal range with tight control for minimization of chances and of periods of exposure to the risk of complications. And, particularly, patients with high risk of complications and with wide fluctuation of INRs should be better managed with frequent monitoring anticoagulation levels.

  • PDF

Clinical Experiences of Continuous Tepid Blood Cardioplegia; Valvular Heart Surgery (미온혈 심정지액의 임상적 고찰)

  • 이종국;박승일;조재민;원준호;박묘식
    • Journal of Chest Surgery
    • /
    • v.32 no.2
    • /
    • pp.130-137
    • /
    • 1999
  • Background: In cardiac surgery, hypothermia is associated with a number of major disadvantage, including its detrimental effects on enzymatic function, energy generation and cellular integrity. Warm cardioplegia with normothermic cardiopulmonary bypass cause three times more incidence of permanent neurologic deficits than the cold crystalloid cardioplegia with hypothermic cardiopulmonary bypass. Interruptions or inadequate distribution of warm cardioplegia may induce anaerobic metabolism and warm ischemic injury. To avoid these problems, tepid blood cardioplegia was recently introduced. Material and Method: To evaluate whether continuous tepid blood cardioplegia is beneficial in clinical practice during valvular surgery, we studied two groups of patients matched by numbers and clinical characteristics. Warm group(37$^{\circ}C$) consisted of 18 patients who underwent valvular surgery with continuous warm blood cardioplegia. Tepid group(32$^{\circ}C$) consisted of 17 patients who underwent valvular surgery with continuous tepid blood cardioplegia. Result: Heartbeat in 100% of the patients receiving continuous warm blood cardioplegia and 88.2% of the patients receiving continuous tepid blood cardioplegia converted to normal sinus rhythm spontaneously after removal of the aortic cross clamp. There were no differences between these two groups in CPB time, ACC time, the amount of crystalloid cardioplegia used and peak level of potassium. During the operation, the total amount of urine output was more in the warm group than the tepid group(2372${\pm}$243 ml versus 1535${\pm}$130 ml, p<0.01). There were no differences between the two groups in troponin T level measured 1hr and 12hrs after the operation. Conclusion: Continuous tepid blood cardioplegia is as safe and effective as continuous warm blood cardioplegia undergoing cardiac valve surgery in myocardial protection.

  • PDF

The Effects of Additional Tetracycline Pleurodesis during Thoracoscopic Procedures for Treating Primary Spontaneous Pneumothorax (일차성 자연 기흉의 흉강경 수술 시 추가로 시행한 Textracycline 흉막 유착술의 효용)

  • Lee, Hyeon-Woong;Lee, Jae-Ik;Kim, Keun-Woo;Park, Kook-Yang;Park, Chul-Hyun;Hyun, Sung-Youl;Jeon, Yang-Bin;Choi, Chang-Hyu
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.729-735
    • /
    • 2008
  • Background: This study was performed to evaluate the safety and efficacy of performing additional tetracycline pleurodesis during the thoracoscopic treatment of primary spontaneous pneumothorax. Material and Method: Between March 2004 and December 2007, 91 cases of primary spontaneous pneumothorax were treated by video-assisted thoracoscopic surgery. The thoracoscopic procedures included resection of the blebs and mechanical pleurodesis by scrubbing the parietal pleura. For 27 cases (Tetracycline group, group I), 20 mg/kg tetracycline was instilled into the pleural space through a trocar before closing the chest. The control group (group II) consisted of 64 cases of primary spontaneous pneumothorax for which the same thoracoscopic procedures alone were performed during the same study period. Result: There was no significant difference between the two groups in terms of the demographic data, the operative findings and the operation time. The percentage of cases that needed intravenous analgesics and the duration of intravenous analgesics were comparable in both groups. There was no significant difference in the duration of air leaks and complications between the two groups. The patients treated with tetracycline pleurodesis had a longer period of postoperative chest drainage (4.2 days vs 3.5 days, respectively, p=0.03) and hospitalization (5.0 days vs 4.0 days, respectively, p=0.006). During the follow up period, the ipsilateral recurrence rate was much lower for the patients who were treated with tetracycline pleurodesis (0% vs 10.9%, respectively, p=0.099), and freedom from recurrence tended to be more favorable for group I (p=0.077), although this was not statistically significant. Conclusion: Additional tetracycline pleurodesis during thoracoscopic treatment for primary spontaneous pneumothorax caused prolongation of chest drainage and a prolonged hospital stay. However, further investigations are needed because tetracycline pleurodesis can be performed safely without serious complications and it showed a distinct tendency to reduce the rate of recurrence.

Midterm Results of the Bioprosthesis in Mitral Position (조직판막을 이용한 승모판 치환술의 중기 성적)

  • Cho, Hyun-Jin;Lee, Jae-Won;Jung, Sung-Ho;Je, Hyoung-Gon;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.695-702
    • /
    • 2008
  • Background: The choice between a bioprosthetic and a mechanical valve is an important decision in cardiac valve surgery, and the durability of the tissue valve is a major decision factor. We retrospectively evaluated the midterm results of bioprosthetic valve replacement in the mitral position. Material and Method: The subjects were all patients who had undergone mitral bioprosthesis replacement between July 1989 and August 200.7. Among the 216 patients, there were 236 surgical cases. The mean age was $63{\pm}15$ years, and the male to female ratio was 1 : 3. We retrospectively analyzed hospital and outpatient records such that the total follow-up duration amounted to 760.2 patient-years, and the mean follow-up duration was $41.9{\pm}40.7$ months (range $0{\sim}212$ months). Result: Early death occurred in 18 patients (8.3%), and 13 of these underwent concomitant cardiac procedures. The survival rate after 5 years was $79.9{\pm}3.5%$, and the survival rate after 8 years was $65.5{\pm}5.5%$, while freedom from structural valve deterioration (SVD) was $96.2{\pm}2.2%$ at 5 years and $85.9{\pm}5.3%$ at 8 years. Freedom from reoperation was $90.6{\pm}1.7%$ at 5 years and $90.4{\pm}4.2%$ at 8 years, while freedom from reoperation for SVD was $98.1{\pm}1.2%$ at 5 years and $92.3{\pm}4.1%$ at 8 years. On multivariate analysis of preoperative risk factors, small valve size (between 25mm and 27mm) was a significant risk factor for reoperation, and low LV ejection fraction (<40%) was a significant risk factor for SVD and mortality. Conclusion: Survival and freedom from reoperation for SVD in mitral bioprosthesis replacement had acceptable midterm results, but freedom from SVD Was relatively low. In particular, since SVD increased sharply at the eighth postoperative year, frequent follow-up and echocardiograms around that time will be helpful for the early detection of SVD. It will be necessary to conduct further studies involving long-term follow-up and more patients.

Effect of Microwave Hyperthermia on Radiotherapy of Human Malignant Tumors -An Analysis of Clinical Response of 42 Patients- (극초단파를 이용한 국소온열 치료 효과 -표재성 종양 42예의 분석-)

  • Yoon Sei Chul;Oho Yoon Kyung;Gil Hak Jun;Chung Su Mi;Shinn Kyung Sub;Bahk Yong Whee
    • Radiation Oncology Journal
    • /
    • v.5 no.1
    • /
    • pp.31-36
    • /
    • 1987
  • Radiobiological and clinical evidences indicate that hyperthermia combined with ionizing radiation produces a significant improvement in therapeutic effect of cancer. In general, malignant cells are more sensitive to heat than normal cells in the heat range of $41\~45^{\circ}C$. We report the experiences obtained from 42 patients with advanced malignant neoplasms managed with 2,450MHz microwave-induced local hyperthermia and ionizing radiation at the Department of Radiology, Kangnam St. Mary's Hospital, Catholic University Medical College. A clinical analysis of 42 thermoirradiated patients showed result of 11(26\%),\;15(36\%),\;11(26\%)\;and\;5(12\%)$ patients with complete response (CR), partial response (PR), minor response (MR) and no response (NR), respectively. Histologically there were $17(40.2\%)$ squamous cell carcinomas, $12(28.6\%)$ adenocarcinomas and $6(14.3\%)$ miscellaneous cancers. Eleven patients with CR consisted of five squamous cell carcinomas, five adenocarcinomas, and one chloroma. Among 15 patients with PR were five squamous cell carcinomas, five adenocarcinomas, three unknown primary tumors, and one poorly differentiated, and miscellaneous tumor each.

  • PDF

Changes in CGRP-immunoreactive Nerve Fibers during Expansion of Midpalatal Suture of the Rat (백서 정중구개봉합 확대후의 CGRP 면역반응 신경섬유의 변화)

  • Kim, Bo-Kyung;Park, Kuk-Pil;Kyung, Hee-Moon;Kwon, Oh-Won;Sung, Jae-Hyun
    • The korean journal of orthodontics
    • /
    • v.29 no.1 s.72
    • /
    • pp.73-81
    • /
    • 1999
  • Midpalatal suture expansion is often used for patients haying narrow maxillary arch, cleft palate, respiratory handicap with narrow nasal cavity. CGRP has been known as a modulator of pain transmission in central nervous system and a local effector to peripheral tissue causing vasodilation, increase of blood flow, modulation of immune system, regulation of macrophagic function and stimulation of bone formation. To investigate changes of CGRP-immunoreactive nerve fibers in midpalatal suture during the expansion, immunohistochemical study was performed by using rats. Experimental rats (10 weeks, 250 gm) were divided into five groups (control, 1, 4, 7, 14 days group (each n=4) and applied orthodontic force (approximately 200gm) to upper anterior incisors. Frozen sections of midpalatal suture area were immunostained by using rabbit antisera. The results were as follows. ${\cdot}$ The CGRP-immunoreactive nerve fibers were hardly observed in control group. ${\cdot}$ In 1 day group, the CGRP-immunoreactive nerve fibers were more increased around the vessels than control group. ${\cdot}$ In 4 days group, the CGRP-immunoreactive nerve fibers were more increased than control group, but not more increased than 1 day group. Vascular diameter was more enlarged. ${\cdot}$ In 7 days group, especially, hematoxilin affinity of cells was remarkable and cells were arranged along the bone margin. The CGRP-immunoreactive nerve fibers were more reduced than 4 days group and vascular diameter was also reduced. ${\cdot}$ In 14 days group, the CGRP-immunoreactive nerve fibers were similar to those of 7 days group and the irregularity of bone margin was almost recoverd. In Conclusion, the CGRP-immunoreactive nerve fibers nay be related to initial neurogenic inflammatory reaction in expanding mid-palatal suture.

  • PDF