• Title/Summary/Keyword: 극초음속 풍동

Search Result 20, Processing Time 0.02 seconds

Design/Construction and Performance Test of Hypersonic Shock Tunnel Part Ⅰ: Design Method of Hypersonic Shock Tunnel (극초음속 충격파 풍동 설계/구축 및 성능시험 Part Ⅰ: 극초음속 충격파 풍동 설계 방법)

  • Lee, Bok-Jik;Lee, Hyoung-Jin;Kim, Sei-Hwan;Jeung, In-Seuck
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.4
    • /
    • pp.321-327
    • /
    • 2008
  • The shock tunnel as a hypersonic ground test facility was designed, constructed and its performance test was conducted to reproduce the high speed flow which the hypersonic propulsion system is encountered. The design points were understood and the conceptual design was completed using the quasi one dimensional operation analysis code. After that, the specific performance and compartment design were completed using CFD simulation as the part analysis. The facility was then constructed according to those design results and the performance test was conducted for various operation conditions. In this paper, we suggested the design method of hypersonic shock tunnel including the conceptual and performance design using theoretical analysis and the quasi 1D Multi-species computational fluid dynamics code.

Design/Construction and Performance Test of Hypersonic Shock Tunnel Part ii : Construction and Performance Test of Hypersonic Shock Tunnel (극초음속 충격파 풍동 설계/구축 및 성능시험 Part II : 극초음속 충격파 풍동 구축 및 성능 시험)

  • Lee, Hyoung-Jin;Lee, Bok-Jik;Kim, Sei-Hwan;Jeung, In-Seuck
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.36 no.4
    • /
    • pp.328-336
    • /
    • 2008
  • The shock tunnel as a hypersonic ground test facility was designed, constructed and its performance test was conducted to reproduce the high speed flow which the hypersonic propulsion system is encountered. The design points were understood and the conceptual design was completed using the quasi one dimensional operation analysis code. After that, the specific performance and compartment design were completed using CFD simulation as the part analysis. The facility was then constructed according to those design results and the performance test was conducted for various operation conditions. In this paper, we suggested the compartment design method using CFD analysis, construction process and various performance test results in detail.

Construction and Performance Test of Ground Test Facility for the Hypersonic Propulsion System (극초음속 추진기관 지상시험 설비 구축 및 성능 시험)

  • Lee, Hyoung-Jin;Lee, Bok-Jik;Kim, Sei-Hwan;Jeung, In-Seuck
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.41-44
    • /
    • 2007
  • Ground test facility for the hypersonic propulsion system was designed, constructed and performance test was conducted. The design point was selected using quasi,1-Dimensional CFD analysis before the conceptual design for construction of hypersonic facility After that, specific designs for performance and components were completed using unit analysis CFD code and performance tests were conducted for the various operation conditions.

  • PDF

Aerodynamic Measurement over a Protuberance in Hypersonic Flows Using Coaxial Thermocouple and TSP (동축열전대 및 TSP를 이용한 극초음속 유동 내 돌출물 주위 공력가열 계측)

  • Lee, Hyoung-Jin;Lee, Bok-Jik;Jeung, In-Seuck;Kim, Seong-Lyong;Kim, In-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.967-974
    • /
    • 2009
  • Experiments were conducted to measure the heat flux and temperature over a protuberance, using an impulse hypersonic shock tunnel-coaxial thermocouples and a blowdown hypersonic wind tunnel-temperature sensitive paints(TSP). Experimental data were compared with the heat flux data using a blowdown hypersonic wind tunnel-heat flux gauges and it was confirmed data sets agreed well. The measured heat flux is large when the height of the protuberance is large. Also, the heat flux measurements at the upper positions are larger than at the lower positions. For high protuberances, a severe jump in the heat flux is observed, from about 0.6~0.7 of the height of the protuberances. However, when the protuberance is sufficiently short, a rise in the heat flux is rarely observed as the protuberance is submerged totally under the separation region.

A Study on the Hypersonic Air-breathing Engine Ground Test Facility Composition and Characteristics (극초음속 공기흡입식 추진기관 지상 시험설비의 구성 및 특성에 관한 연구)

  • Lee, Yang-Ji;Kang, Sang-Hun;Yang, Soo-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.6
    • /
    • pp.81-90
    • /
    • 2015
  • In order to know the characteristics of the hypersonic air-breahting engine, high altitude and Mach number ground test is necessary. Therefore, high pressure and high temperature condition should be simulated to do ground test of the hypersonic air-breathing engine. In this paper, the hypersonic air-breathing engine ground test facility of the Korea Aerospace Research Institute was introduced and the composition and characteristics were described.

Modificaion and Performance Test for improving ability of Supersonic/Hypersonic Wind Tunnel(MAF) (초음속/극초음속 풍동(MAF)의 성능 향상을 위한 개조 및 검증)

  • Choi, Won-Hyeok;Seo, Dong-Su;Lee, Jae-Woo;Byun, Yung-Hwan
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.717-722
    • /
    • 2010
  • Supersonic/Hypersonic wind tunnel is a facility which is intended to test and to observe the physical phenomena around a model by creating supersonic flow in the test section. In designing an airplane, the wind tunnel test is demanded to analyzing aerodynamic characteristics of the model without making a prototype. In this research, the model aerodynamic facility(MAF) is modified for the purpose of increasing running time and its functionality. New pneumatic valves for remote control was installed for safety requirement, and new air tanks was installed on MAF as well. A pipe system is also modified to use those new valves and tanks, and the ceiling and side glasses of the test section are switched to ones with the larger surface area. After the MAF modification, a test is performed at Mach 2, 3 and 4. In this test, shadow graph technique, one of the flow visualization methods, is used to visualize supersonic flow field. The pressure in the settling chamber and working section at Mach 2, 3 and 4 was measured in each case. As a result, the possible model size and running time are obtained.

  • PDF

Concept Design of Ludwieg Tube at Konkuk University (건국대학교 Ludwieg Tube 개념 설계에 관한 연구)

  • Kim, Young Ju;Byun, Yung Hwan;Park, Soo Hyung;Park, Gisu;Lee, Jongkook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.9
    • /
    • pp.703-711
    • /
    • 2018
  • A preliminary design tool of a hypersonic Ludwieg tube facility which simulates real-flight environment was developed and its performance was verified by CFD(Computation Fluid Dynamics) calculations. The operating theory of Ludwieg tube was studied to develop the preliminary design tool. Using the preliminary design tool, Ludwieg tube specifications were determined to satisfy target performance. The Ludwieg tube which produces high speed flows(the Mach number ranging 4 to 10) was designed. Especially altitude simulation at Mach 4 flow could be performed.

Measurement of Aerodynamic Heating over a Protuberance in Hypersonic Flow of Mach 7 (Mach 7 극초음속 유동 내의 돌출물 공력가열 계측)

  • Lee, Hyoung-Jin;Lee, Bok-Jik;Jeung, In-Seuck;Kim, Seong-Lyong;Kim, In-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.6
    • /
    • pp.562-570
    • /
    • 2009
  • An Experimental study was conducted on the flow characteristics and interference heating caused by a two-dimensional object protruding from a flat plate using a blow-down type of hypersonic wind tunnel. Inflow condition was a free-stream Mach number of 7.0 and a unit Reynolds number of $2.0{\times}10^6/m$. Experimental conditions were varied with three heights of protuberance for two flat plate models which have different lengths. Experimental data were obtained from Schlieren visualization images and heat flux measurements. Also, this paper suggests hypersonic experimental techniques such as boundary-layer detection method in detail. A Large separation region was observed in front of the protuberance and that region was very sensitive to the height of protuberance and the length of the flat plate. For only the highest protuberance, a severe jump of heat flux was observed at the top station among the measuring points. Measured heat flux is large when the height of protuberance is large and the length of flat plate is long.

A Study on the Wind Tunnel Facility Performance Improvement of ADD Ludwieg Tube (국방과학연구소 Ludwieg Tube 풍동설비 성능개량 연구)

  • Sangjun Ma
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.4
    • /
    • pp.118-125
    • /
    • 2023
  • The wind tunnel test is one of the essential processes in the development of guided missile systems, and various wind tunnel facilities exist depending on the test requirements, various conditions, and their purposes. The Ludwieg tube is very useful in the development of guided missile systems, and we have necessitated the upgrade of the Ludwieg tube in ADD to acquire various test requirements, such as high angle of attack, repeatability, and stability. In this paper, upgrading the nozzle, vacuum tank, and model support is suggested to improve the Ludwieg tube performance, and we demonstrate a result of the solution through pressure measurement.

Characteristics of Hypersonic Airbreathing Propulsion System and Preliminary Design of Supersonic Combustion Tunnel (극초음속 추진기관의 특성 및 초음속 연소 풍동 기초 설계)

  • 김정용;허환일
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.35-38
    • /
    • 2001
  • The aerothermodynamic characteristics of SCRamjet engine for the airbreathing populsion system of the next generation flight vehicle are described. As the flow is passing by, combustion caused the total pressure loss and the Mach number decrease, but nozzle exit velocity is large enough to produce net thrust. To simulate supersonic combustion test, preliminary design of ground-based blowdown type supersonic combustion tunnel is attained. Minimum allowable operating pressure and mass flow rate are calculated for the design Mach number of 2.5 at the test section of a supersonic combustion tunnel.

  • PDF