• Title/Summary/Keyword: 귀금속주조

Search Result 20, Processing Time 0.02 seconds

A Study of Margin Fitness in Metal-bond Porcelain Crown II (도재용착주조관 변연의 적합성에 관한 연구 II)

  • Lee, In-Kyu
    • Journal of Technologic Dentistry
    • /
    • v.5 no.1
    • /
    • pp.27-30
    • /
    • 1983
  • This study was undertaken to know the difference that margin fittness in metal bond porcelain crown. When we use porcelain precious metal and non-precious metal as porcelain-fused metal, the results were as following. 1. The precious metal was showed best result in margin fittness and shade. 2. The non-precious metals were showed good results, especially Gemini II was excellent, but that was not good than precious metal. 3. 10k. gold plating on non-precious metal cap showed same result as nonprecious metal in margin fittness, and not good in shade. 4. When we use the non-precious metals at upper part of crown, and using precious metal in 2mm cervical portion, the margin fittness were very good, and the results same as full veneer precious metal.

  • PDF

A Study on the Direct Casting of Photo-polymer (포토 폴리머의 직접 주조에 관한 연구)

  • Kim, Woo-Soon;Kim, Dong-Hyun
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.6
    • /
    • pp.127-133
    • /
    • 2006
  • Rapid prototyping technologies have been widely used to reduce the development cost of new products. Manufacturing industries are nowadays characterized by the flexibility and complexity of products. This to due to the rapid development of manufacturing technology and diverse needs of customers. In this paper, the best homing out and casting condition for getting casting product of resin pattern(photopolymer) have been examined experimentally. In generally, the burning out and casting conditions have effect on the casting products. Using the direct casting. we directly Producted the Jewelry. And in this paper, we used only gypsum. Many study of casting for resin have been used to dental investment. A dental investment is good for resin casting. but dental investment is too hard and not useful on the jewelry casting. Therefore we need to find the way of resin casting by gypsum.

MICROSTRUCTURE OF COMBINATION CLASP JOINTS IN REMOVABLE PARTIAL DENTURE (가철성(可撤性) 국부의치(局部義齒)에서 연합(聯合) Clasp 연결부위(連結部位)의 미세구조(微細構造))

  • Son, Han-Kee;Kim, Tae-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.123-132
    • /
    • 1984
  • To evaluate the microstructure of various combination clasp joint in removable partial denture, the auther selected framework alloys (Type IV gold alloy, Dentaurium, Ticonium 100) and wrought wires (gold alloy, Ticonium) for this study. Twelve series of combination joints were made by investment soldering technic and wrought wire embedded casting technic. All specimens were cut cross-sectionally and longitudinally, then examined with metallurgical microscope. The results were as follows; Some diffusion was observed in the properly constructed combination clasp joints. In soldered joints, empolying precious alloys were more favorable than non-precious alloys. In castion joints, assemblage of same alloy between framework and wrought wire was superior to other groups. Some impurities were observed in both joints by technical problems.

  • PDF

FIT OF ONE-PIECE CAST FIXED PARTIAL DENTURES (One-Piece cast법에 의한 가공의치의 적합성에 관한 연구)

  • Garlapo, Davis A.;Lee, Sun-Hyung;Choung, Chin-Koo;Sorensen, Soren E.
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.20 no.1
    • /
    • pp.19-23
    • /
    • 1982
  • 귀금속의 가격 앙등은 치과보철치료에 있어서 비귀금속합금의 이용을 촉진 시키고 있다. 가공의치 제작에 비귀금속합금을 이용할 경우에는 납착상태에 대한 신빙성 문제로 인하여 one-piece cast법이 널리 사용되고 있으나 이에 의하여 제작된 가공의치의 적합도에 관하여는 논의가 분분하다. 고로 저자는 one-piece cast법에 의한 비귀금속 가공의치에 있어서 경화수축에 따른 거리변화를 계측현미경을 이용하여 연구한 결과 다음과 같은 결론을 얻었다. 1. 4개 치아를 포함하는 가공의치 제작에 있어서 Hi-Temp 매몰재는 비귀금속합금(Lite-Cast B)의 수축을 보상하고도 남음이 있다. 2. Hi-Temp에 사용되는 액(液)을 증류수로 희석할 경우 그 농도 조절에 의하여 Hi-Temp 매몰재의 팽창을 크게 변화시킬 수 있다. 3. one-piece cast법에 의한 가공의치 제작의 문제점은 두 지대치의 서로 바라보고 있는 인접면간의 거리는 증가됨이 없이 외측 인접면간의 거리만 다소 증가되어야 한다는 것이다. 4. 비귀금속합금을 이용하여 수직적인 큰 변형없이 4개 치아가 포함되는 가공의치를 제작할 수 있다. 5. 수개 치아를 포함하는 가공의치의 주조 정확도를 계측할 수 있는 새로운 방법을 창안하였다.

  • PDF

About Korean Precious Metal Industrial Activation Plan Research (With a Focus on Synthetic Gem) (한국 귀금속산업 활성화 방안분석(CAD/CAM을 중심으로))

  • Park, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.613-621
    • /
    • 2009
  • Except for traditional industrial art and history of design development, Korea jewelry industry before 1980's, had little meaning in the aspect of marketing and business. Domestic jewelry market which have changed from the value of goods to value of ornaments, faced important transition point for jewelry industry by the chance of in Asian Game held in 1986, and money of overseas traveler after 1980s. The rapidly-grown Jewelry field by the introduction of detail casting method to make it possible mass-production of the products before 1990's, began to change into new system, with introducing CAD/CAM after 1990's. Jewelry industry has changed from manual work called handmade to the detail casting industry based on master for mass-production. For this, the development of master, with the design development, have been suggested as important task to jewelry industry firms, and by the introduction of CAD/CAM, the diversification of design and master development has been made up. In this study, we would try to find out current status of domestic jewelry field and to understand CAD/CAM, and advantage of CAD/CAM, and through this, suggest good solution to precipitate domestic jewelry market.

The Comparative Study on the Castability to the Frequency of Reuse with Precious Metal Alloys and Base Metal Alloys widely used in the Production of Partial Denture (국부의치(局部義齒) 제작(製作)에 사용(使用)되는 귀금속합금(貴金屬合金)과 비귀금속합금(非貴金屬合金)의 재(再) 사용(使用) 횟수에 따른 주조성(鑄造性) 비교(比較) 연구(硏究))

  • Chung, Kyung-Pung;Choi, Un-Jae
    • Journal of Technologic Dentistry
    • /
    • v.17 no.1
    • /
    • pp.10-25
    • /
    • 1995
  • The purpose of this study is to get the difference of the castability in the production of partial denture between Precious Metal Alloys and Base Metal Alloys accompanied with the frequency of reuse. As materials for an experiment, we selected Baker-444 and Soo-444 and Soo-sung as Precious Metal Alloys, New Crown and Chrome Cobalt as Base Metal Alloys. And we tired to case all of them seven times. The experimental results were as follows : 1) In the probability of segments, Baker-444 showed 100$\pm$0.00%, Soo-sung 97.24$\pm$1.58%, New Crown 95.63$\pm$4.28%, and Chrome Cobalt 91.03$\pm$7.76%. Consequently, Precious Metal Alloys were decidely superior to Base Metal Alloys in the castability. 2) In the view of the acheived result, burn-out temperature and smocking time had greatly affected the castability. 3) After casting, Precious Metal Alloys were much less than Base Metal Alloys in the quantity of consumption. It made much difference from the the compiled stastics(p<0.01)

  • PDF

AN EXPERIMENTAL STUDY OF LASER EFFECTS ON A BASE METAL ALLOY FOR DENTAL CASTING (레이저가 치과주조용 비귀금속합금에 미치는 영향에 관한 실험적 연구)

  • Kim, Kyoung-Nam
    • The Journal of the Korean dental association
    • /
    • v.22 no.9 s.184
    • /
    • pp.781-792
    • /
    • 1984
  • The purpose of this experiment was to study the effects of laser on a base metal alloy for dental casting. In this study, microhardness, corrosion resistance, wear resistance, interaction behavior of metal-ceramic interface, and bond strength were tested before and after the laser treatment for metal-ceramic alloy. The conclusion arised from this study are as follows: 1. The hardness of lased area was higher than that of unlased area. 2. The corrosion resistance was higher in lased specimen than in unlased specimen. 3. the wear resistance was higher in Iased specimen than in unlased specimen. 4. The EDAX showed that Mo, Si and Al were increased in lased surface but Ni and Cr not increased. 5. The SEM of lased area revealed a typical microstructure. 6. The bond strength of lased specimen was increased in 11.2% than of unlased specimen.

  • PDF

Microstructure Property of Silver Clay (성형 은 점토 소재의 미세구조와 경도 변화)

  • Song Ohsung;Kim Kyungah
    • Proceedings of the KAIS Fall Conference
    • /
    • 2005.05a
    • /
    • pp.58-60
    • /
    • 2005
  • 기존의 금속조형물은 만드는 공정으로 주조-후처리 또는 정밀 기계가공방법은 많은 시간과 노력이 필요한 단점이 있었다. 최근에 귀금속 성형점토 (PMC)라는 마이크로 크기의 분말과 바인더가 혼합되어 마치 점토와 같이 직접 수공 또는 치공구를 이용하여 완성하고 $650-850^{\circ}C$ 정도의 저온에서 소결하여 단시간 안에 최종 조형물을 만들 수 있는 신공정이 개발된 바 있다. 본 연구에서는 선진사와 비슷한 $1{\~}3{\mu}$m급은 분말을 1:1로 혼합하고 고형 바인더를 첨부하여 기존 선진사와 동등하거나 우수한 미세조직과 표면경도를 확보하고 조형비가 있는 시작품을 만드는데 성공하였다.

  • PDF