• Title/Summary/Keyword: 구조 감쇠

Search Result 1,064, Processing Time 0.026 seconds

A Control Method of Semi-active TMD for Vibration Control (진동제어를 위한 준능동 TMD의 제어기법)

  • Lee, Ki-Hak;Kim, Gee-Cheol;Lee, Eun-Suk
    • Journal of Korean Association for Spatial Structures
    • /
    • v.7 no.2 s.24
    • /
    • pp.53-61
    • /
    • 2007
  • A conventional passive TMD is only effective when it is tuned properly. In many practical applications, inevitable off-tuning of a TMD occurs because the mass in a building floor could change by moving furnishings, people gathering, etc. When TMDs are offtuned, TMDs their effectiveness is sharply reduced. Moreover, the off-tuned TMs can excessively amplify the vibration levels of the primary structures. This paper discusses the application of a new class of MR damper, for the reduction of floor vibrations duo to machine and human movements. The STMD introduced uses a MR damper called to semi-active damper to achieve reduction in the floor vibration. Here, the STMD and the groundhook algorithm are applied to a single degree of freedom system representative or building floors. The performance or the STMD is compared to that or the equivalent passive TMD. In addition, the effects of off-tuning due to variations in the mass of the floor system. Comparison of the results demonstrates the efficiency and robustness of STMD with respect to equivalent TMD.

  • PDF

Wave Transformation Due to Energy Dissipation Region (에너지 감쇠영역으로 인한 파랑변형)

  • 윤종태
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.11 no.3
    • /
    • pp.135-140
    • /
    • 1999
  • To simulate the wave transformation by an energy dissipation region, a numerical model is suggested by discretizing the elliptic mild-slope equation. Generalized conjugate gradient method is used as solution algorithm to apply parabolic approximation to open boundary condition. To demonstrate the applicabil-ity of the numerical procedure suggested, the wave scattering by a circular damping region is examined. The feature of reflection in front of the damping region is captured clearly by the numerical solution. The effect of the size of dissipation coefficient is examined for a rectangular damping region. The recovery of wave height by diffraction occurs very slowly with distance behind the damping region.

  • PDF

Evaluation of Influence Bounds of the Soil for Soil-Footing Interaction System considering Damping Effect of the Soil (지반의 감쇠효과를 고려한 지반-기초 상호작용계에 대한 지반의 영향범위 산정)

  • 장병순;서상근;최태환
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.12 no.3
    • /
    • pp.281-292
    • /
    • 1999
  • 지반-기초 상호작용계를 해석할 때 실제로 지반은 다양한 지반종류와 다층으로 형성되어 있으므로 지반 특성의 변화를 고려해야 한다. 초기의 대부분의 상호작용계의 정·동적 해석은 지반의 복잡한 성질을 역학적으로 탄성거동을 한다고 가정한 Winkler 지반모델 혹은 지반을 등방성이고 균질한 반무한 탄성체로 가정한 반무한 탄성지반 모델로 보아 수행되었다. 본 연구는 유한 요소법을 이용하여 지반-기초 상호작용계의 동적 거동을 해석하기 위해 기초는 4절점 후판요소를 사용하고 지반은 지반특성을 고려할 수 있도록 8절점 6면체 요소를 사용하였고, 지반의 감쇠효과 및 지반특성을 고려한 지반-기초 상호작용계의 동적 거동을 유한요소법으로 해석하고 지반의 영향범위를 결정하는 것이다.

  • PDF

Equivalent Viscous Damping Ratio of a Friction Damper Installed in a SDOF Building (단자유도 건물에 설치된 마찰감쇠기의 등가점성감쇠비)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.2
    • /
    • pp.199-208
    • /
    • 2010
  • A friction damper installed at a building shows nonlinear behavior since its stick and slip states are occurred repeatedly depending on the amplitude of external loadings to dissipate input energy. Friction damping is existed for the building with a friction damper. In additionally viscous one is inherently included. Therefore, the building installed in such combined damping is quite involved to find the analytical solution. In this study, first, displacement and acceleration characteristics are identified based on the exact solution for a single-degree-freedom building with a friction damper having both friction and viscous damping. Second, in free vibration, the equivalent viscous damping ratio is obtained by the energy dissipation. Third, numerical analysis is carried out to find response configuration with various friction force ratios. Fourth, corresponding equivalent viscous damping ratio is derived with the finding that the response reaches into steady-state for both friction and viscous damped structure. It is deduced using balance of input external energy and output dissipation energy for steady-state response. Finally, the equivalent viscous damping ratios of free or harmonic vibration are verified through nonlinear analysis.

Vibration Control Effect of the Framed Building Structures according to the Stiffness Ratio of Exo-type Damping System and Damper Device Yield Ratio (Exo-type 감쇠시스템의 강성비와 감쇠장치의 항복비에 따른 라멘조 건물의 제진효과)

  • Hur, Moo-Won;Lee, Sang-Hyun;Chun, Young-Soo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.38-44
    • /
    • 2015
  • In this paper, the vibration control effect of the Exo-type damping system was investigated by applying the Kagome dampers to 15-story and 20-story frame structure apartment. A new Exo-type damping system composed of the dampers and supporting column was proposed in the previous work and numerical analysis were performed to investigate the effects of optimum stiffness ratio between controlled structure and supporting column, the size of damper and yield ratio of the damper. The numerical analysis results of a structure with Exo-type damping system up to the third story showed that the stiffness ratio should be higher than 7.0 and the damper device yield ratio be at least 8.0% ($V_{damper}/V_{base\;shear$) to effectively reduce the base shear and the maximum drift of the uppermost story. When the Exo-type damping system was installed up to the fifth story, the stiffness ratio should be higher than 2.5 and damper device yield ratio needs to be at least 3.5% ($V_{damper}/V_{base\;shear$) for obtaining the target performance.

Control Effectiveness of Shear Walls Connected by Beams with Friction Dampers (인방보에 마찰형 감쇠기가 설치된 전단벽의 제진효과)

  • Chung, Hee-San;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.105-115
    • /
    • 2009
  • Numerical analysis of shear walls governed by flexural behavior is conducted for the seismic control performance of proposed friction dampers installed at the center of coupling beams. Control effectiveness of shear walls connected by beams with the proposed dampers are compared for single shear wall with same flexural rigidity. Average responses of the shear walls with the dampers are found with seven scaled-downed earthquakes based on KEC 2005 design spectrum. Slip load is the most important design parameter. It is designed to be 5, 10, 20, 30, 60, 90% of total vertical shear force at damper location to prevent damper slip in specific stories. Nonlinear time-history analysis is conducted by using SeismoStruct analysis program. Seismic control performance of the dampers is evaluated for base shear, energy dissipation, curvature and top-floor displacement. Results show that the dampers are the most effective in reducing the responses when their total slip load is 30% of total vertical shear force.

Damping Characterization of the Double-skin Aluminum Extruded Panels for Rolling Stock Carbody (철도차량 차체용 더블 스킨 알루미늄 압출 패널의 감쇠특성)

  • Kang, Gil-Hyun;Kim, Chul-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3197-3202
    • /
    • 2013
  • When car builder designs the large carbody structure of railway vehicles, it is necessary to optimize the damping characteristics through the analysis of structure borne noise such as sound pressure level(SPL). This paper is a study on the structure borne noise analysis by characterizing the damping of double skin aluminum extruded panels for rolling stock carbody. The normalized SPL was calculated based on the simple source theory using measured mechanical mobility parameters from vibration tests(i.e. point, transfer and modal mobility). The reduced SPL was predicted by using finite element method by applying loss factor of damping material into laminated shell elements. It was found out that the damping material coated on the panels like underframe, which part is seriously affected by vibration during train run, took effect to reduce noise level.

Attenuator using Lossy Left-Handed Transmission Line and Vector Modulator Application (손실이 있는 Left-Handed 전송선로를 이용한 감쇠기와 벡터 변조기 응용)

  • Kim, Seung-Hwan;Kim, Ell-Kou;Kim, Young;Yoon, Young-Chul
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.3
    • /
    • pp.399-405
    • /
    • 2009
  • This paper proposes a design of attenuator based on meta-material structure and its application. The unit-cell attenuator based on the lossy transmission line consists of the CRLH(Composite Right/Left Handed) transmission line and PIN diodes to be controlled internal loss according to diode bias voltage to change resistance of diode. Also, to reduce the initial losses, there is used parallel connection of PIN diodes. To increase attenuations, it is connected a cascade unit-cell of attenuator with periodic structure. The attenuation quantities of unit-cell are about 10dB and phase variations are 15o maximum at 1.5 GHz ~ 2.5 GHz. Also, its application is represented a vector modulator.

  • PDF

블럭형 진동기초의 설계

  • 윤정방
    • Computational Structural Engineering
    • /
    • v.6 no.1
    • /
    • pp.11-16
    • /
    • 1993
  • 진동기초의 해석 및 설계에서의 주요사항은 진동하중자체의 특성을 산정하는 것과 기초구조의 수평, 수직, Rocking, Pitching 응답의 해석 및 수평-Rocking이 연계된 운동의 해석이다. 현재 사용되는 진동기초설계의 해석방법은 Reissner(1936)의 반무하지반영역 위에 놓인 원형강판에 대한 해석적 결과를 이용한 여러가지 변형된 방법이 사용되고 있다. 이러한 진동기초의 해석방법은 지반의 모형화하는 방법에 따라 탄성 반무한영역으로 지반을 모형화하는 경우 (Reissner(1936), Shekhter(1948), Sung(1953), Quinlan(1953), 등)와 감쇠-탄성스프링에 의해 지반을 모형화하는 경우 (Lysmer and Richart(1966), Barkan(1962), 등)로 나눌 수 있다. 최근의 실제 설계에는 선형스프링 이론을 바탕으로 하여, 감쇠효과와 진동에 참여하는 흙의 질량영향을 무시하는 Barakan(1962)의 방법이 많이 사용되고 있다.

  • PDF

Dissipation Effects Induced by Substructures Comprised of Multiple oscillators (다수의 진동체로 구성된 부 구조물에 의한 감쇠 효과)

  • Choi, Sung-Hoon;Kim, Yang-Hann
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.12 no.6
    • /
    • pp.445-452
    • /
    • 2002
  • The goal of this paper Is to characterize the vibration damping induced in a main structure by a large number of sub-oscillators. A simple expression is obtained for the substructure impedance when the number of sub-oscillators approaches Infinity. It is found that the induced damping depends on the total mass of the sub-oscillators resonating in a frequency band of interests and nearly independent of their Individual loss factors. A modal overlapping condition. which corresponds to bandwidths that exceed the spacing of those natural frequencies, is required for the sub-oscillators to have such effects. An impulse response of the system is also considered. When the sub-oscillators lack damping and do not satisfy the modal overlapping condition, the vibratory energy is returned from the sub-oscillators to the main structure at later times. The result of this paper is consistent with that found with the fuzzy structure and SEA framework.