• Title/Summary/Keyword: 구조벽

Search Result 1,091, Processing Time 0.032 seconds

Effect of Cap Truss on Optimal Outrigger Location in Tall Building (초고층건물에서 아웃리거 구조의 최적위치에 대한 캡 트러스가 미치는 영향)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.6
    • /
    • pp.40-49
    • /
    • 2013
  • This study purposed to investigate the optimal outrigger location in tall building with cap truss after a structural schematic design of 80 stories building was performed by using MIDAS-Gen. In this paper, the main parameters of structural analysis were the outrigger location and stiffness of main structural elements (outrigger, exterior column, shear wall etc). In order to search the optimal outrigger position in high-rise building with cap truss, we analysed and examined the lateral displacement of top floor which is one of the very important considering factors of tall building structural design. The paper results indicated that the outrigger location and the stiffness of main structural elements such as outrigger, exterior column and shear wall had an effect on the optimal outrigger location. And it is verified that the study results provided the basic engineering data for fixing the most optimal outrigger location for minimizing the lateral displacement of tall building.

Analysis of Lateral Behavior in Core and Offset Outrigger System (코어 및 오프셋 아웃리거 구조시스템의 수평거동에 대한 분석)

  • Kim, Hyong-Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.1-11
    • /
    • 2021
  • The research intended to understand the lateral behavior in core and offset outrigger system. To achieve this goal, a structural analysis and design of 70 stories building was carried out by making use of MIDAS-Gen. And the primary parameters of this analysis were the stiffness of outrigger and the location of outrigger in plan. On the basis of the analysis results, we analyzed the lateral behavior of structural elements such as slab, outrigger and exterior columns in core and offset outrigger. In this analysis research, it is indicated that the stiffness of outrigger and the outrigger location in plan had an any impact on lateral behavior in outrigger system of tall building. Specially, slab stresses in core outrigger system were highly distributed in the slab near the outrigger system to connect shear walls and exterior columns while slab stresses in offset outrigger system were highly distributed in the slab between the outrigger system and shear walls. Also the study results can be of significant help to obtaining the engineering data for the reasonable structure design of the high-rise outrigger system.

Consideration of the Stage-Discharge Relation in Spiral Intake (나선식 유입구 수위-유량 관계 검토)

  • Rhee, Dong-Sop;Kim, Chang-Wan
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2007.05a
    • /
    • pp.894-898
    • /
    • 2007
  • 지하방수로는 도시의 지하에 대규모 수로 터널을 시공하여, 도시 지역에 발생한 집중 호우를 초기에 배제하여 제내지 침수 피해를 줄이는 목적으로 사용되는 대표적인 구조적 홍수 피해 경감 대책이다. 효과적으로 침수피해를 줄일 수 있을 뿐만 아니라, 특히 지하에 설치되어 토지 수용에 대한 부담이 줄어들기 때문에 일본 등지에서 최근 주요 홍수 방어 대책으로 활용되고 있다. 지하방수로 유입부는 크게 접근수로, 유입구, 수직 갱도(vertical shaft)로 구분되며, 접근 수로를 통하여 유입된 흐름은 유입구를 통하여 가속된 후 수직 갱도로 유입되게 된다. 따라서 지하방수로의 배제 능력을 평가하기위해서는 유입구에서의 유량 및 흐름 특성을 정확히 평가하는 것이 매우 중요하다. 나선식 유입구(spiral intake)는 지하방수로 유입구 중 가장 일반적으로 사용되는 형식으로 일반적으로 접근수로 수위를 측정하여 유입량을 예측할 수 있다. 본 연구에서는 수리 모형 실험을 통하여 나선식 유입구에 대한 수위-유입량 관계를 검토하였다. 평탄한 입구를 가지는 안내벽이 있는 형식의 나선식 유입구 모형을 이용하여 수위-유입량 관계를 검토하였다. 또한 측정된 수위 및 유입량을 바탕으로 기존 연구자들이 제시한 안내벽이 없는 형식의 나선식 유입구에 대한 수위-유입량 관계와 비교 검토하였다. 검토 결과 안내벽이 있는 형식의 나선식 유입구는 안내벽이 없는 경우에 비하여 유량 배제 효율이 떨어지는 것으로 나타났다.

  • PDF

Pilot Application of Fire Barrier Penetration Seal Evaluation in Nuclear Power Plant (원자력발전소 방화벽 관통부 성능평가 시범 적용)

  • Park, Jun-Hyun
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.98-104
    • /
    • 2006
  • The Fire Protection Regulatory documents require the fire-resistive rating of fire barrier penetration seals be same as that of fire barriers. Pilot application of penetration seal evaluation for K nuclear plant, built before penetration seal requirements were made, was done. In this evaluation, visual inspection and estimating fire rating by comparing installed configuration with tested configuration of penetration seals, called bounding approach method, were applied. Further improvements for retrofit and maintenance are recommended with penetration seal evaluation results also. The practical use of the methodology adopted in this study and the evaluation result of K nuclear plant will be anticipated for other plant's penetration seal evaluation.

Prediction of Inelastic Force-Displacement Relationships of Reinforced Concrete Shear Wall Systems Based on Prescribed Ductilities (강성저하 실험식 및 연성계수를 이용한 철근콘크리트 전단벽 구조시스템의 비탄성 하중-변위 관계식 예측)

  • 홍원기
    • Computational Structural Engineering
    • /
    • v.8 no.4
    • /
    • pp.159-171
    • /
    • 1995
  • The parameters describing a complete hysteresis loop include pinch force, drift offset, effective stiffness, unloading and reloading trangential stiffness. Analytical equations proposed to quantify the nonlinear, inelastic behavior of reinforced shear walls can be used to predict these parameters as a function of axial load and drift ratio. For example, drift offset, effective stiffness, and first and second unloading and reloading tangential stiffness are calculated using equations obtained from test data for a desired drift ratio or ductility level. Pinch force can also be estimated for a given drift ratio and axial load. The effective virgin stiffness at the first yield and its post yield reduction can be estimated. The load deflection response of flexural reinforced concrete shear walls can now be estimated based on the effective wall stiffness that is a function of axial force and drift ratio.

  • PDF

Experimental Study on the Composite Bridge Deck of Hollow Section (중공단면 복합소재 교량 바닥판의 시험을 통한 구조적 특성 분석)

  • Lee, Sung-Woo;Kim, Byung-Suk;Hong, Kee-Jeung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.4 s.74
    • /
    • pp.325-335
    • /
    • 2006
  • In this paper, flexural test, girder-connection test and barrier-connection test for the pultruded composite bridge deck of hollow section, were carried out and its structural characteristics were evaluated. In the flexural test specimen, deflection was measured at center of the span and strains were measured at various locations to see the structural behavior up to the failure. In addition, finite element analysis was performed for the flexural test specimen and the results were compared with experiments, and load carrying capacity was evaluated. Also, field load test was conducted for the demonstration plate girder bridge and other field applications were described.

A Study on The Composition and Characteristics of WaIls through Visual Configuration Analyses - Focusing on the Exhibition Space for Paintings - (시각구조분석을 통한 벽의 구성과 특성에 관한 연구 -회화위주 전시공간을 대상으로-)

  • Lee, Jong-Sook;Park, Jong-Won
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.8 no.2
    • /
    • pp.57-64
    • /
    • 2008
  • The walls of art museums become the background of exhibits, and they form a unit space depending on the of each exhibit. In addition, the walls are configured and presented depending on the rhythm of space, or the structure of an axis. In this study, according to the axis composed for each unit space, the presentation methods of walls were classified as follows: The central type, the skewed type, the crossed type, the one-side corridor type, and the two-way corridor type. By analyzing visual configurations formed by the arrangement of each unit space, the value and the hierarchy of walls are discussed To analyze the classified types with the physical change of unit space, the factors of visual integration, connectivity, depth, and visual axis are compared, and various configurations of walls and space change are applied.

  • PDF

Numerical Simulations of Gravity Currents Using Unsteady Statistical Turbulence Models (비정상 통계적 난류모형을 이용한 중력류의 수치모의)

  • Paik, Joong-Cheol
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.570-574
    • /
    • 2009
  • 벽 근처에서의 흐름(near wall flow)을 해석하기 위한 낮은 레이놀즈수 수정(low-Reynolds number modification)을 포함하는 통계학적 난류모형을 이용한 3차원 비정상 레이놀즈-평균 나비어-스톡스 (URANS) 계산을 실시하여 사각형 수로에서의 중력류를 모의하였다. 3차원 계산 결과를 2차원 URANS 모의에 의한 계산 결과 그리고 실험결과와 비교하였다. 이 연구 결과는 적정 시 공간적 수치해상도를 가지고 벽 근처에서의 흐름을 주의 깊게 직접 해석하는 3차원 URANS 수치모의는 2차원 계산으로는 해석할 수 없는 대규모 Kelvin-Helmholtz 와구조 (vortical structure)의 붕괴(breakdown) 그리고 중력류 선단부에서 발달하는 Lobe-and-Cleft 흐름 불안정 등을 포함하는 중력류의 동적 특성을 높은 정확도로 재현할 수 있음을 보여준다.

  • PDF

Wave Reflection and Transmission Characteristics of Flap-type Floating Breakwaters (플랩형 부유 방파제의 파랑 반사 및 전달 특성)

  • Jeong, Shin-Taek;Park, Woo-Sun;Kim, Jeong-Dae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2141-2145
    • /
    • 2008
  • Three kind of system composed with buoyant flap hinged at the sea floor are modeled experimentally. The mechanically coupled system provides shelter by reflecting incident waves and by attenuating wave energy through structural and viscous damping. The characteristics of wave reflection, transmission and dynamic angle of the flap oscillation for various conditions were investigated. The structure can minimize wave transmission by attaching offshore wing wall.

  • PDF

Study on the Composite Blast Wall Test (복합 재료 폭파 방화벽 실험 연구)

  • Yang, Hyun-jung;Kang, Young-Jong
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.1 no.4
    • /
    • pp.6-12
    • /
    • 2010
  • This study investigates how to apply composite material to the blast loading protection devices, mainly used for military purpose. Traditionally, earth-filled blast walls have been used for protecting important parts of military facilities and personnels. However these types of blast walls show difficulty in fabrication and portability because of their nature of heavy weight. Composite materials are known to have relatively higher specific stiffness and strength than any other metallic and earth-filled materials such as sand and gravels. Totally 4 times of TNT blast experiments were performed on the carbon/epoxy blast walls. After the end of each test, the improvement of blast wall was implemented to the structure. The test results show that the use of composite material in the blast protecting area is the one of very effective and reliable alternatives.

  • PDF