• Title/Summary/Keyword: 구조물 안전진단

Search Result 560, Processing Time 0.023 seconds

Derivation of the Mechanical Properties of Structural Steels at High Temperatures (고열 환경에서의 구조용 강재 특성 데이터베이스 구축)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.47-55
    • /
    • 2007
  • The mechanical properties such as 0.2% and 1% offset proof strength and elastic modulus are essential for a structural steel structure when the structure would be evaluated and designed to identify the performance of the structural stability exposed to fire condition. To obtain the mechanical properties for the structural steels at high temperature which are consisted of ordinary and marine ones, the tensile tests at various high temperatures had been conducted with two kinds of specimen of general structural steel SS 400 and welded steel SM 490 at the range of room temperature to $900^{\circ}C$ at interval of $100^{\circ}C$.

Performance-Based Evaluation on Evacuation Safety of Road Tunnels Considering Fire Size and Evacuation Exit (화재 크기와 피난연결통로를 고려한 도로터널의 성능기반 피난안전성 평가)

  • Si-Hyun Oh;In-Wook Heo;Sang-Ki Lee;Seung-Ho Choi;Sunnie Haam
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.4
    • /
    • pp.28-36
    • /
    • 2024
  • In this study, an analytical evaluation of evacuation safety in typical road tunnels was conducted. The Fire Dynamics Simulator (FDS) was employed to perform fire simulations with varying fire sizes to determine the allowable evacuation time in road tunnels. Additionally, evacuation simulations were performed using Pathfinder, considering the width of barrier doors and the spacing of evacuation passageways, to calculate the required evacuation time. A comparison between the allowable and required evacuation times was conducted to assess the impact of fire size, passageway spacing, and barrier door width on tunnel evacuation safety. The results from the fire and evacuation simulations indicated that an increase in fire size and passageway spacing, along with a decrease in door width, resulted in an increase in the number of casualties. Conversely, increasing the barrier door width to more than 1.2meters led to a reduction in casualties as passageway spacing increased.

Analysis of Scaling Factor applied to Lab-Scale Model for Estimating Dynamic Characteristics of Real Structures (실구조물의 동특성 파악을 위한 축소모형에 적용되는 상사비 분석)

  • Park, Gun;Yoon, Hyungchul;Kim, Sung Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.1
    • /
    • pp.59-66
    • /
    • 2021
  • The earthquakes are the natural disasters that can cause the most serious damage to civil structures. Therefore, various studies are being conducted to secure the safety of structures against earthquakes. Most studies on the safety or mechanism of civil structures during earthquakes are being conducted based on lab scale test, because real structure tests are impossible when considering the scale of civil structures. The scaling factor proposed by Iai is mainly cited, but when applying the scaling factor proposed by Iai, there are many difficulties in selecting the structural members necessary for the production of the lab scale model. This is because when applying the scaling factor proposed by Iai, the scaling factor must be applied to the elastic modulus, which is the material property of the structure. Therefore, a new method based on Iai's 's similarity law for determining scale factor is applied in this study where the material property of real structure is same as that of lab-scale model. Through the results of this study, it is considered that the characteristics of the structure calculated through the lab scale model test can more accurately reflect the characteristics of the real structure.

부유체식 Container Yard 접안선박의 계류안전성 분석에 관한 연구

  • Kim, Seung-Yeon;Park, Seong-Hyeon;Kim, Cheol-Seung;Lee, Sang-Do
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.06a
    • /
    • pp.47-49
    • /
    • 2013
  • 항만 확장 시 기존의 매립 방식은 건설비용 및 환경 파괴 등의 문제가 발생함으로써, 부유체식 구조물을 이용한 해상 부두의 활용이 국내외에서 주목받고 있다. 이와 관련하여 본 연구에서는 선박의 계류안전성평가에 대한 개념을 정립하고 이를 부유체식 Container Yard에 적용하기 위한 자연환경, 선박 및 부두 모델링을 수행하였다. 본 연구 자료를 토대로 향후 부유체식 Container Yard에 접안한 선박의 환경외력 및 계류삭의 장력 평가, 방충재와 계선주에 작용하는 반력 및 견인력 평가, 부두의 운동에 따른 안전성을 파악하고, 해상 부두로서의 적용 가능성을 검토하여 안전한 부두의 설계 기준 및 활용 방안을 마련하고자 한다.

  • PDF

A Safety Analysis of Tunnel Lining for Monitoring (계측에 의한 터널 라이닝의 안전성 분석)

  • Woo, Jong-Tae;Lee, Song
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.3
    • /
    • pp.103-110
    • /
    • 2002
  • Maintenance monitoring of the tunnel which offers continuous data during and after tunneling has been applying to tunnels in order to meet the maintenance of tunnel and to confirm continuous security of the tunnel after tunneling. But, the maintenance monitoring of tunnel results for long period is not easy to find, and moreover, the rational analysis method on tunnel monitoring has not been established yet. In this study, the relationships between displacement and stress of the tunnel concrete lining using various analysis methods are compared with maintenance monitoring. The tunnel behavior were measured in the subway tunnel passing comparative soft the weathering and analyzed both security and mechanical characteristics of the tunnel concrete lining. Also, analyzed relationship between residual water pressure applied on tunnel design and one obtained by monitoring.

A Safety Assessment of Weld Defective Steel Bridges (강교량의 용접불량에 따른 안전도 분석)

  • Park, Seung-Bum;Bang, Myeung-Sug;Kim, Do-Gyeum
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.1 no.2
    • /
    • pp.107-113
    • /
    • 1997
  • Nondesructive test and structural analysis have been conducted to assess the safety of weld defective steel bridges in service. In the nondestructive test, using the radioactive ray and ultrasonic, the defective welding patterns in the steel bridges are identified. A major defective welding pattern is identified as the lack of welding area due to the insufficient welding penetration. By considering the welding defect in the above, structural analysis is conducted to evaluate the influence of welding defect on the safety of steel bridges. The results indicate that, due to the insufficient welding penetration, the stress obtained in the analysis is over the allowable fatigue stress level, and its influence on safety of the bridges is significant.

  • PDF

A Study on the Development of Safety Demolition Work System by using Work Breakdown Structure (작업분류체계(WBS)를 이용한 안전해체공사 시스템 개발에 관한 연구)

  • Kim, Kyang-Seo;Yang, Keek-Young;Lee, Yung-Su;Yoon, Yer-Wan;Kim, Chun-Hak
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.3
    • /
    • pp.176-187
    • /
    • 1998
  • The Dismantlement and Construction of the buildings have the characteristic of floating change with repetition within a Time Schedule which has fixed resources, that is, Manpower, Materials and Equipments, and involve many disaster factors in performing each processes. But as these factors are variable, a work supervisor should be able to understand data analysed distinctive factors of each activities systematically, organizationally, and scientifically, and diagrammatic information media so that he can control any complex and situation beyond forecast. Thus this study is intended to be a barometer of weighing if the existing process schedule has taken security into consideration by making the characteristics of organization and action of Work package per process in a building field with more factors like these into a network system and is intended to minimize construction disasters by systematizing this into a Transformational Network.

  • PDF

Safety Estimation of Repaired Finger Joint (교체된 Finger Joint의 안전성 평가)

  • Kim, Ji-Hoon;Han, Kyung-Bong;Park, Sun-Kyu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.6 no.1
    • /
    • pp.241-254
    • /
    • 2002
  • Though there are many kinds of type in the expansion joint of bridges, Transflex joint was usually used from 1970's to 1980's. But it made of rubber is needed to exchange to new one often because of the breakage by wheel load. This study performed the safety estimation which is to exchange the transflex joint to finger joint kept the part of situ-cast-concrete. The standard of finger joint is same as that of transflex joint, we investigated the safety of finger joint with experimental results and FEM (Finite element method) analysis.

Steel Rod Damper and Rocking Behavior (강봉 댐퍼와 록킹 거동)

  • Lee, Hyun-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.1-9
    • /
    • 2020
  • In this study, a seismic reinforcement system was developed considering the rocking behavior of walls. The rocking behavior is to rotate left and right around the vertical axis of the wall, and the development system is a method of dissipating energy by installing a damper to a large displacement part. Developed steel rod damper was used, and steel rod diameter and length(aspect ratio) were selected as variables. As a result of the experiment, it was evaluated to have excellent seismic performance when the damper length was 260mm.

Development and Performance Evaluation of Under Cut Anchor Stone Curtain Wall Construction Method (언더컷 앵커 방식의 석재 커튼월 공법 개발 및 성능평가)

  • Chang, Kug-Kwan;Park, Nam-Wook
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.4
    • /
    • pp.138-146
    • /
    • 2014
  • Structural safety as well as variety and aesthetics of building facade are currently gathering more attention in building construction and stone curtain wall is widely used in exterior wall. However, two main problems are existed in curtain wall construction method. One is an uniformity of construction quality and the other is a repair work of stone panels. Also, the noise and vibration occurring in construction may be cause of civil complaint. Therefore, a new method is needed to overcome these problems. This paper presents a new stone curtain wall system using under cut anchor and secondary holes that was developed in this study. Additionally, structural performance evaluation was conducted to verify the constructability and structural safety for wind pressure and seismic load. Through the evaluation of this method, improved constructability and economic efficiency were verified.