• Title/Summary/Keyword: 구리-은

Search Result 289, Processing Time 0.029 seconds

Technical trend of Surface treatment for FPCB (FPCB표면처리와 최신기술개발동향)

  • Kim, Yu-Sang
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2012.05a
    • /
    • pp.291-292
    • /
    • 2012
  • 플렉시블 (F-PCB, Flexible Printed Circuit Board)은 얇고 유연하며 모바일, 광학, 노트북, 프린터, LCD 등 IT산업전반에 걸쳐 사용되고 있다. 통신기기가 이동용으로 전환되면서 대용량, 고속의 정보 전달이 필요하다. 인접 회로간의 전자파 차폐, 구리성분의 편석방지와 고성능의 회로소재 확보가 요구된다. 본고에서는 최근의 플렉시블 인쇄회로기판의 주석도금의 위스커방지 품질향상을 중심으로 기술하였다.

  • PDF

Effects of Supplementary Copper Sources (Cu Sulfate, Cu-Methionine, Cu-Soy Proteinate) on the Performance Broiler Chickens (구리 공급원들(Cu Sulfate, Cu-Methionine, Cu-Soy Proteinate)의 첨가가 육계의 생산성에 미치는 영향)

  • Lee, Mun-Ku;Kim, Chan-Ho;Shin, Dong-Hun;Jung, Byoung-Yun;Paik, In-Kee
    • Korean Journal of Poultry Science
    • /
    • v.38 no.2
    • /
    • pp.121-128
    • /
    • 2011
  • This study was conducted to investigate the effects of dietary supplementation of Cu-sulfate, Cu-methionine chelate (Cu-Met) and Cu-soy proteinate (Cu-SP) on the performance, blood parameters and mineral contents of muscle. It was conducted with a total of 1,000 one d old broilers chickens (Ross$^{(R)}$) which were assigned to four dietary treatments; Control, Cu sulfate (200 ppm Cu as $CuSO_4{\cdot}5H_2O$), Cu-Met (200 ppm Cu as Cu-methionine chelate), Cu-SP (200 ppm Cu as Cu-soy proteinate). There were significant differences (p<0.05) among treatments in weight gain. Weight gain of Cu treated groups were higher than the control during 3~5 wk. There were significant differences (p<0.05) among treatments in feed intake during 0~3 wk. Cu-Met was significantly (p<0.05) lower than the control but the differences among Cu treatments were not significant. There were significant differences (p<0.05) among treatments in feed conversion rate (FCR). Cu treated groups were lower than the control during the whole period. Production efficiency factor (PEF) was significantly higher (p<0.01) in Cu treated groups than the control. Nutrient availabilities of diets were not significantly different among the treatments. The count of white blood cell (WBC) and eosinophil (EO) were lower in Cu-SP treatment than in the control. Copper concentration in the liver was significantly (p<0.01) higher in Cu treated groups than the control. Zinc concentration in the breast and wing muscle was lower in Cu treated and that of leg muscle was higher in Cu-Met than the control. The result of this experiment showed that Cu supplementation at the level of 200 ppm as Cu sulfate, Cu-Met and Cu-SP improves weight gain (4~5 wk), FCR and PEF. Differences among Cu sources were not significant.

Operational Characteristics for a Miniature Heat Pipe with a V-shaped Groove Wick (V형 그루브윅을 갖는 소형 히트파이프의 작동특성)

  • 강환국;김철주;홍성은
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1999.05a
    • /
    • pp.197-205
    • /
    • 1999
  • 소형 히트파이프에서 ?을 구리망사 또는 그루브를 적용할 수 있고 그루브 형상은 U, V 등 다양하다. 망사?은 모세압이 큰 잇점이 있어나 제작 단가가 높다. 그루브?은 대량생산이 용이하나 전밀 가공 기술이 요구된다. 현재까지 국내에서는 노트북 PC의 CPU 냉각에 사용한 소형 히트파이프의 전량을 해외에서 구매하고 있다. 본 연구에서는 직경 7 mm U형 그루브 관을 인발하여 관직경을 축소한 결과 내경 3.6 mm의 외경 4mm 의 V형 그루브관을 얻을 수 있었다. 이 관을 이용하여 소형 히트파이프를 제작하고 열전달 성능 시험을 수행하였다. 열전달 한계는 40~6$0^{\circ}C$ 범위작동온도 경사각 0$^{\circ}$ 에서 3 W를 얻을 수 있었다. U형 그루브 히트파이프에 비하여 모세압 저하로 인하여 낮은 값을 나타내었다. 열저항을 약 0.7~l.3 $^{\circ}C$/W 로 U형 그루브와 유사하였다.

  • PDF

Magnetic Resonance Imaging uses 3D Printed Material of Headset (Noise Reduction Effect) (자기공명영상 검사 시 3D 프린팅 재료를 이용한 헤드셋 연구 (소음저감 효과))

  • Choi, Woo Jeon;Kim, Dong Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.335-341
    • /
    • 2018
  • With the improvement of medical state, patients' expectations for the most advanced medical equipment are increasing. Particularly, Magnetic Resonance Image (MRI) is used as one of the core image diagnosis methods in all clinical area. However, it has been reported that many of patients who go through the examination suffer from anxiety to the severe noise level during the examination. In this study, both the noise reduction evaluation of headsets with sound-blocking materials added to existing sound-absorbing materials and the existence of sound blocking materials as artifacts on the examination image are tested. An MRI test noise is recorded as a speaker by cross-ordination the sound material (sponge) and the sound material (acrylic plate, copper plate, and 3D copper plate) inside the headset made from 3D pring. A quantitative assessment of headsets showed that the average headset value was 81.8 dB. The average dB value of the most soundproof material combination(Copper, acrylic plate, sponge, sponge) headsets on headsets with added charactering material was measured at 70.4 dB, and MRI showed that the copper was diamagnetic substance and excluded. The second most soundproof headset(Sponge, acrylic plate, 3D copper plate, sponge) was measured at 70.6 dB and MRI showed no artifacts. The same simulation of the material printed with a 3D copper PLA containing approximately 40 % copper powder resulted in no artifacts, therefore, the material output as a 3D printing was better suited for use. For MRI related research, the mutual development of 3D printing is highly anticipated.

Effects of Process Variables on Preparation of Silver-Coated Copper Flakes Using Hydroquinone Reducing Agent (하이드로퀴논 환원제를 사용한 은코팅 구리 플레이크의 제조에서 공정 변수의 영향)

  • Chee, Sang-Soo;Lee, Jong-Hyun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.24 no.3
    • /
    • pp.57-62
    • /
    • 2017
  • In the process for preparing Ag-coated Cu flakes by electroless silver plating using hydroquinone reducing agent, Ag coating qualities were compared by changing various process parameters such as type of pretreatment solution, plating temperature, pH of plating solution, type and injection rate of plating solution, and pulp density. Effective pretreatment solution for removing the oxide layer on a Cu flake was preferentially suggested. The conditions of low plating temperature, pH value of 4.34, slow injection rate of Ag plating solution, elimination of deionized water in the Ag plating solution, and high pulp density significantly suppressed the formation of separated tiny Ag particles, and thus the surface coverage of Ag coating on Cu flakes was enhanced.

Heavy Metals in Paddy Soil of Korea (우리나라 논 토양중(土壤中) 중금속(重金屬) 자연함량(自然含量))

  • Kim, Bok-Young;Jung, Beung-Kan;Choi, Jeong-Weon;Yun, Eul-Soo;Choi, Sun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.28 no.4
    • /
    • pp.295-300
    • /
    • 1995
  • In order to find out the natural content of heavy metals(Cd, Cu, Pb, Zn, Cr, Ni)in paddy soil of Korea, a total of 1,196 soil samples of 15cm top layers all over the country 1995 were collected and analyzed. The average heavy metal contents in soils were 0.133mg/kg of Cd, 4.52mg/kg of Cu, 4.62mg/kg of Pb, 3.90mg/kg of Zn, 0.362mg/kg of Cr and 1.38mg/kg of Ni. These results are similar to the results of survey conducted in 1981.

  • PDF

Sonochemical Synthesis of Copper-silver Core-shell Particles for Conductive Paste Application (초음파를 이용한 구리-은 코어-쉘의 합성 및 전도성 페이스트 적용)

  • Sim, Sang-Bo;Han, Jong-Dae
    • Applied Chemistry for Engineering
    • /
    • v.29 no.6
    • /
    • pp.782-788
    • /
    • 2018
  • Submicron copper-silver core-shell (Cu@Ag) particles were synthesized using the sonochemical combined transmetallation reaction and the application to printed electronics as a low cost conductive paste was evaluated. $Cu_2O$ of the $Cu_2O/Cu$ composite used as a core in the reaction for the synthesis of core-shell was sonochemically reduced to Cu, and Cu atoms functioned as a reducer for silver ions in transmetallation to achieve the copper-silver core-shell structure. The characterization of submicron particles by TEM-EDS and TG-DSC confirmed the core-shell structure. Conductive pastes in which 70 wt% Cu@Ag was dispersed in solvents were prepared using a binder and wetting agents, and coated on the polyamide film using a screen-printing method. Printed paste films containing synthesized Cu@Ag particles with 8 at% and 16 at% Ag exhibited low resistivity of 96.2 and $38.4{\mu}{\Omega}cm$ after sintering at $180^{\circ}C$ in air, respectively.

Development of Low-Cost High-Performance Antibacterial Tempered Glass (저비용 고기능성 항균강화유리 개발을 위한 연구)

  • Kim, Jun-Sub
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.562-567
    • /
    • 2021
  • To develop an antibacterial tempered glass for applications to various building facilities and household products, the antibacterial activity of domestic materials was investigated, and a tempered glass sample was produced with silver, copper, and zinc, having an antibacterial activity of 99% or more at a specific concentration. The measured antibacterial activity of the samples, in which silver, copper, and zinc were dispersed in ethylene glycol + glycerol, was more than 99%. Measurements of the thickness of the coated metal material by washing using a surface analyzer showed that the thickness decreased by less than 1% in various types of detergents, including water, but only approximately 10% in the alkaline detergents. To check the human safety of the samples, a cytotoxicity test was performed through an MTT assay; the samples showed no cytotoxicity. Finally, a Live/Dead kit or film adhesion method showed that the antibacterial activity of the prototype was more than 99%. Therefore, the high-functional antibacterial effect of tempered glass was developed using domestic materials and may be used in various products in the future.

SUITABILITY OF SHELLFISH FOR PROCESSING 2. Seasonal Changes in Heavy Metal Content of Baby Clam (패류의 가공적성 2. 바지락 중금속함량의 시기적 변화)

  • LEE Eung-Ho;RYU Byeong-Ho;YANG Syng-Tack
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.8 no.2
    • /
    • pp.85-89
    • /
    • 1975
  • Heavy metal content have been determined in baby clams from March 1973 to April 1974 in Depori, Samchunpo, Korea. Monthly changes of mercury, lead, copper ana cadmium in the samples were irregular but as a whole, the content of mercury, lead, copper and cadmium were relatively high in summer season. The content of total mercury, lead, copper and cadmium in the samples ranged from 0.003 to 0.038 ppm, 0.096 to 0.931 ppm, 0.023 to 0.139 ppm and 0.009 to 0.038 ppm respectively. In the consideration of heavy metal content, it was concluded that baby clams in Depori, Samc hunpo, Korea is suitable for processing materials.

  • PDF

Analysis of Characteristic of Graphene Thin Film Transistor and Properties of Graphene using Copper Substrate (구리기판을 이용한 그래핀 박막 특성 및 그래핀을 이용한 트랜지스터의 특성 분석)

  • Oh, Teresa
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.9
    • /
    • pp.2127-2132
    • /
    • 2013
  • Graphene thin film was prepared on the copper foils by chemical deposition, and the characteristic of graphene depending on $H_2$ and CH4 gas flow rates was analyzed by the Raman spectra. The graphene formation was improved with increment of methan gas flow rates. The increment of hydrogen gas flow rate made high intensity of D($1350cm^{-1}$) and G($1580cm^{-1}$). The peak of D($1350cm^{-1}$) is related with the defects, and the 2D($2700cm^{-1}$) increased depending on the increment of amount of methan gas flow rate. The rate of G/2D indicates the quality of garphene to like a monolayer, and the small value of G/2D means better grapheme. The G/2D of graphene after annealed at $200^{\circ}C$ was 0.55 and improved the characteristic of graphene than the deposited-grapnene. Thin film transistor with graphene as an active channel was p-type semiconductor.