• Title/Summary/Keyword: 교체기준

Search Result 269, Processing Time 0.025 seconds

Evaluation of Toothbrush Bristles' Wear Index and Wear Rate Used by Preschool Children (일부 어린이집 유아의 칫솔 마모도 및 마모율 평가)

  • Kim, Sun-Ju
    • Journal of dental hygiene science
    • /
    • v.13 no.2
    • /
    • pp.151-157
    • /
    • 2013
  • The purpose of this study was to examine the toothbrush bristles' wear index and wear rate used by preschool children to provide information on the establishment of criteria for toothbrush replacement cycle for preschool children. One thousand twenty-two toothbrushes were collected from September 20 to November 16, 2012 was analyzed. The findings of the study were as follows: 1. As a result of analyzing the toothbrush wear index, 48.5% of the collected toothbrushes was above 0.400, and the average wear index was $0.421{\pm}0.239$. 2. As a result of analyzing the wear rate of the toothbrushes, score 2 and 3 accounted for 70.4%, and the average wear rate stood at $1.936{\pm}0.848$. 3. As a result of analyzing the state of toothbrush management, the most common average toothbrush replacement cycle was one or two months (63.9%). Concerning the method of toothbrush replacement, the largest group (52.7%) replied they changed toothbrushes based on the abrasivity of toothbrush bristles, and 16.7 percent did that at the request of parents. Given the above-mentioned findings of the study, preschool teachers and parents should be educated to ensure the successful management of preschool children toothbrushes. In addition, it's required to set evident criteria for the right toothbrush replacement cycle for preschool children, and how to provide oral health education in an efficient way should be considered as well.

The Fatigue Life Evaluation of Aged Continuous Welded Rail on the Urban Railway (도시철도 장기 사용레일의 피로수명 평가)

  • Kong, Sun-Young;Sung, Deok-Yong;Park, Yong-Gul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.821-831
    • /
    • 2013
  • As a result of recent research, it is reported that the periodic replacements criterion of rails is able to extend as grinding rail surface and using the continuous welded rail (CWR). In this study, we carried out fatigue tests on existing laid rails. Based on the test results, an S-N curve expressing the remaining life of laid rails at a fracture probability of 50% was obtained using weighted probit analysis suitable for small-sample fatigue data sets. As rails used for testing had different histories in terms of accumulated tonnage, the test data were corrected to average out the accumulated tonnage. We estimated the remaining service lives for laid rails on the urban railway using equations developed in the past to estimate rail base bending stress and that surface irregularities into consideration. Therefore, estimating the remaining service life of laid rails showed that the rail replacement period could be extended over 200 MGT, although it is necessary to remove longitudinal rail surface irregularities at welds by grinding. Also, the fatigue test results under fatigue limit, Haibach's rule appling half slope of S-N curve under the fatigue limit was considered more reasonable than modified Miner's rule for estimating rail fatigue life.

A Study on the Supply and Perception of Personal Protective Equipments for Fire Fighters (화재진압대원의 개인보호장구 지급 실태 및 인식에 관한 연구)

  • Choi, Jaehyeong;Kim, Woojae;Kang, Shinwook;Kim, Junggon
    • Journal of the Society of Disaster Information
    • /
    • v.12 no.4
    • /
    • pp.381-388
    • /
    • 2016
  • In this study, we surveyed the supply and perception of Personal Protective Equipments for firefighters. As a result, most of the respondents answered that they were paid in accordance with the supply standard, but 12% of the respondents said that there were insufficient equipment. Also, satisfaction with the performance of the equipment is mostly satisfied, but the safety gloves are more than 50% dissatisfied. In summing up the results of the survey, it is urgently necessary to improve the current supply standard, which is determined by the life of PPE, to the replacement period according to the using time or frequency. Also, a new standard should be prepared through the follow - up study.

Monitoring of Major Viral Pathogen Contamination in New and Reused Broiler Farm Litter (육계 농장 깔짚에서의 주요 바이러스 병원체 오염 실태 조사)

  • Choi, Kang-Seuk;Jeon, Woo-Jin;Lee, Eun-Kyoung;Kwon, Jun-Hun;Lee, Jin-Hwa;Sung, Haan-Woo
    • Korean Journal of Poultry Science
    • /
    • v.38 no.3
    • /
    • pp.181-189
    • /
    • 2011
  • A 5-month (May to November in 2009) monitoring program for five viral pathogens in litter, such as avian influenza virus A (AIV), infectious bronchitis virus (IBV), infectious bursal disease virus (IBDV), fowl adenovirus (FAdV), and chicken infectious anemia virus (CIAV) was conducted in 62 flocks at 31 broiler farms (two flocks in each farm) in Korea in 2009. Viral pathogens were examined twice (before and at the end of the rearing period) at 31 broiler farms, and included fresh litter (n = 16) and recycled litter (n = 15) farms. Thirty-seven viruses (14 IBVs, 2 IBDVs, 9 FAdVs, and 12 CIAVs) were isolated from 75% (12/16) and 73% (11/15) of fresh litter and reused litter farms during the period, respectively, indicating no difference in viral contamination rate between farms using new and reused litter. Of these isolates, three (two CIAVs and one IBDV) were isolated from recycled litter samples collected before the rearing period at three broiler farms, whereas the others (n=34) were isolated from fresh and recycled litter samples collected at the end of the rearing period. When the performances, involving viability, body weight, and feed conversion ratio, were compared, no significant differences were found between farms using fresh and recycled litter during the period.

A Study on the Effective Controlling System of Radio-activity Ventilation (RI사용 의료기관의 효율적인 배기관리 방안)

  • Lee, Kyung-Jae;Lee, Jin-Hyung;Kim, Kyung-Hoon;Kwack, Dong-Woo;Jo, Hyun-Duck;Ko, Kil-Man;Park, Young-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.1
    • /
    • pp.91-98
    • /
    • 2008
  • Purpose: Radio-isotopes (RI) use has been steadily developing due to industrial and technical development in the modern medical society. Particularly, popularization of domestic cyclotrons dramatically enable hospitals to produce and use diagnostic radio-isotopes. Generally, only specific facilities such as hospitals, research institutes, nuclear power plants and universities can use radio-isotopes, they are also responsible for ventilation system. The strength of radioactivity in the air is strongly regulated and controlled by korea atomic energy law in Korea Institue of Nuclear Safety (KINS), so that air radioactivity exposure can lead to environmental pollution surrounding places. In this study, we'd like to find out the investigation and the present condition of the controlled ventilation system in domestic hospitals by an emission standard from KINS, and try to reach an agreement about how to use the ventilation system. Result: Definition of filters, features and structures of pre-filters, hepa-filters, charcol filters, filter exchange procedures and precautions are explained. RI deflation concentration and filter exchange cycle have been presented as a standard prescribed in the rules of KINS. The Radiation Control Management System (RCMS) introduced by Seoul National University Bundang Hospital linking to digital pressure gauge with computer controller in another medical facilities were described in details. Conclusions: The system of medical facilities using RI has been remarkably developing in 21 century. Especially, radiation safety control system has also been grown rapidly into the subdivision, specialization, advanced technology along with international technical improvement. However, As far as current RI ventilation system is concerned, it has nothing better than doing in the past. Preferentially, to reinforce this, more sophisticated system with strict periodic filter exchange and exhaust air control guidance should be introduced by applying brilliant domestic information technology for RCMS and digital gauge method. From personal point of view as a radiation safety manager, I have provide with present problems and improvements. Futhermore, more improved guidance should be conducted.

  • PDF

A Study on the Response Characteristics Depending on Service Life of Ionization Smoke Detector (이온화식연기감지기의 사용기간에 따른 응답특성 연구)

  • Baek, Won-Don;Kim, Shi-Kuk;Ok, Kyung-Jea;Lee, Chun-Ha;Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.61-64
    • /
    • 2008
  • This paper studied on the response characteristics depending on service life of ionization smoke detector. The experimental samples used ionization smoke detectors (360 EA) for over 5 years which were influenced by environment set up with fire objects. The experimental method performed operate and non-operate test according to 'Type Approval and Technical Regulation of Detector (KOFEIS 0301)', for estimate the response characteristics of ionization smoke detector depending on service life. The results showed that their response characteristics were rapidly decreasing when the longer their using period. Accordingly, it is desirable that ionization smoke detector has to be changed for early fire detection when passed their service life.

A study of sensitive reduction from cable when off-line partial discharge measuring (OFF-LINE 부분방전 측정 시 CV케이블에 의한 방전량 감도저하 현상 고찰)

  • Yi, Jong-Seuk;Lee, Eun-Chun;Chae, Ji-seog;Ham, Dong-Younf;Ok, Yeon-Ho;Byun, Du-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1177-1178
    • /
    • 2015
  • 국내 전력설비는 70년대 이후 제3차 경제개발 5개년 계획에 따라 중화학공업의 발전과 함께 급속히 성장해왔다. 과거 개발 위주의 산업구조에서 급속히 팽창한 전력설비는 21세기에 들어서면서 30~40년 장기 사용에 따른 노후화가 진행되었고, 증가하는 전력수요에 대응하기 위한 발전 및 송전 용지 확보의 어려움으로 인하여 전력설비의 신규 증설에 많은 어려움을 격고 있는 실정이다. 따라서 전력설비의 안전성과 신뢰성을 확보하기 위해 적절한 교체시기 선정 및 최적의 자산관리 필요성에 대해서 최근 관심을 가지기 시작하였고, 이러한 전력설비의 최적 자산관리에 핵심적인 전력설비의 상태평가 기술의 발달로 과거 시간기준의 유지보수(Time Based Maintenance)에서 최근 노후설비의 증가와 진단기술의 발달에 따른 예방보전(Preventive Maintenance)에 의한 상태기준 유지보수(Condition Based Maintenance)개념으로 전환되고 있다. 고전압 회전기기(발전기, 전동기)의 상태평가를 위한 핵심기술인 Off-line 부분방전시험이 널리 적용되고 있으며, 본 논문에서는 부분방전 측정 시험 시 대상설비 단자부의 인출케이블에 의한 감도저하 현상에 대해 고찰 하였다.

  • PDF

An Analysis of Classroom Illuminance with Simulation Program and Improvement of Classroom Illumination (시뮬레이션프로그램을 활용한 교실조도 분석 및 개선방안)

  • Shin, Hyun-Man;Jang, Woo-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.129-134
    • /
    • 2009
  • The actual conditions of school illumination was investigated. The illumination state was classified by the number of installed luminaires per 1 classroom. The illuminance state was measured and analyzed. The work surface illuminance was up to the standard, but the illuminance on blackboard was below standard when there was no local illumination. As a result of conducting a simulation based on the mesurement of the reflection factors of the classroom finishing materials and lamp replacement and lamp cleaning, nine luminaires for general lighting and local lighting for the blackboard were required, and the kind of design considered illumination maintenance was called for.

  • PDF

An Analysis of Classroom Illuminance with Simulation Program end Improvement of Classroom Illumination (시뮬레이션 프로그램을 활용한 교실조도 분식 및 개선안)

  • Shin, Hyun-Man;Jang, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.14-23
    • /
    • 2009
  • The actual conditions of school illumination was investigated. The illumination state was classified by the number of installed luminaires per 1 classroom. The illuminance was measured and analyzed. The work surface illuminance was up to the standard, but the illuminance on blackboard was below standard when there was no local lighting. As a result of conducting a simulation based on the measurement of the reflection factors of the classroom finishing materials and lamp replacement and lamp cleaning, nine luminaires for general lighting and local lighting for the blackboard were required, and a design considering illumination maintenance was called for.