• Title/Summary/Keyword: 교정 계수

Search Result 185, Processing Time 0.026 seconds

Statistical Calibration and Validation of Mathematical Model to Predict Motion of Paper Helicopter (종이 헬리콥터 낙하해석모델의 통계적 교정 및 검증)

  • Kim, Gil Young;Yoo, Sung Bum;Kim, Dong Young;Kim, Dong Seong;Choi, Joo Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.8
    • /
    • pp.751-758
    • /
    • 2015
  • Mathematical models are actively used to reduce the experimental expenses required to understand physical phenomena. However, they are different from real phenomena because of assumptions or uncertain parameters. In this study, we present a calibration and validation method using a paper helicopter and statistical methods to quantify the uncertainty. The data from the experiment using three nominally identical paper helicopters consist of different groups, and are used to calibrate the drag coefficient, which is an unknown input parameter in both analytical models. We predict the predicted fall time data using probability distributions. We validate the analysis models by comparing the predicted distribution and the experimental data distribution. Moreover, we quantify the uncertainty using the Markov Chain Monte Carlo method. In addition, we compare the manufacturing error and experimental error obtained from the fall-time data using Analysis of Variance. As a result, all of the paper helicopters are treated as one identical model.

Lifetime Estimation of an Axle Drive Shaft by Calibrated Accelerated Life Test Method (CALT 방법을 이용한 액슬구동축의 수명 예측)

  • Kim, Do-Sik;Kim, Hyoung-Eui;Yoon, Sung-Han;Kang, E-Sok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.273-281
    • /
    • 2010
  • In this paper, a method to predict the fatigue life of an axle drive shaft by the calibrated accelerated life test (CALT) method is proposed. The CALT method is very effective for predicting lifetimes, significantly reducing test time, and quantifying reliability. The fatigue test is performed by considering two high stress and one low stress levels, and the lifetime at the normal stress level is predicted by extrapolation. In addition, in this study, the major reliability parameters such as the lifetime, accelerated power index, shape parameter, and scale parameter are determined by conducting various experiments. The lifetime prediction of the axle drive shaft is verified by comparing the experimental results with load spectrum data. The results confirm that the CALT method is effective for lifetime prediction and requires a short test time.

Evaluation of Nuclear Medicine Applications of 3D Printing Phantom - Gamma Camera Centrically (3D 프린팅 팬텀의 핵의학분야 적용 평가 - 감마카메라 중심으로)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Ji-Hyeon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.65-73
    • /
    • 2017
  • Purpose 3D 프린팅 기술은 3D 스캔이나 모델링을 통하여 적측가공 방식으로 제작하는 기공기술로서 금형 없이 직접 생산이 가능하고 빠른 시간 내에 제작이 가능하여 최근 다양한 산업분야에서 본격적으로 적용되고 있다. 3D 프린팅 기술은 의료분야에 있어, 영상의학 및 방사선 치료분야에서 다양하게 활용되고 있지만 핵의학 분야에서는 관련 연구가 미비한 실정이다. 그러므로 본 연구는 기존에 적용되고 있는 핵의학분야 팬텀과 3D 프린팅 기술로 제작된 텀의 특성을 비교하고 적용 가능성을 평가하는데 목적을 두었다. Materials and Methods 방사선 투과도 변화측정 국제기준 팬텀인 알루미늄(Aluminum) 계단 쐐기(step wedge)를 기준($140mm{\times}62mm{\times}35mm$)으로 PMMA(Poly Methyl Meta Acrylate)와 ABS(Acrylonitrile Butadiene Styrene)재질로 각각 동일한 크기의 팬텀을 제작하였다. PMMA 팬텀은 핵의학 분야에서 주로 적용되는 팬텀의 성분과 동일한 소재로 제작하였고, ABS 팬텀 제작은 3D 프린팅 기술의 액체 기반형의 SLA(Stereo Lithography Apparatus)기법을 사용하여 제작하였다. 본 연구는 SPECT/CT장비 BrightView XCT(Philips Health Care, Cleveland, USA)를 이용하였다. 영상 획득은 Rectangular Flood phantom(Biodex, New York, USA) $^{99m}TcO_4$ 3, 6 mCi와 $^{57}Co$ lood phantom(adqual, New Hampshire, USA) $^{57}Co$ 20 mCi를 이용하여 Aluminum, PMMA, ABS 팬텀에 대해 60 min 리스트모드(List mode)로 획득하였다. 획득한 영상의 분석을 위해 관심영역(ROI)을 설정하여 각 팬텀의 단계별로 평가하였다. Results 방사선원의 종류 및 방사선량에 따라 ABS 팬텀의 계수치는 PMMA 팬텀의 계수치와 유사한 값을 나타내며, 두께의 증가에 따라 선형적으로 감소하였다. Aluminum, PMMA, ABS 팬텀의 선감약계수를 비교했을 때, Aluminum 팬텀의 선감약계수는 나머지 두 팬텀보다 수치가 높았고, PMMA, ABS 팬텀에서는 근사치의 선감약계수가 나타났다. Conclusion 3D 프린팅 기술로 제작된 ABS 팬텀을 기준으로 PMMA 팬텀은 두께가 증가함에 따른 계수치의 변화가 유사하게 선형적으로 감소하였고, 선감약계수도 근사치로 나타내었다. ABS 팬텀의 핵의학적 적용 가능성을 확인할 수 있었으며, 추후 연구를 통해 세부적인 교정치(correction value)를 적용한다면 활발한 적용이 가능하리라 사료된다.

  • PDF

A Method for Determining Dead Times of a G.M. Defector as a Function of the Count Rate

  • Ro, Seung-Gy
    • Nuclear Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.3-7
    • /
    • 1971
  • A method for determining dead times of a G.M. detector as a function of the count rate has been investigated using the Mn$^{56}$ radioactive sample. The formula, (equation omitted), seems to be useful for determining a relation between the dead time and the count rate. Here (equation omitted)(N$_1$) is the dead time for the count rate N$_1$, N$_1$is the count rate at time zero, Nt is the count rate at time t, λ is the radioactive decay constant of the sample used, and t is the time between the first and second runs. When all the counting data were corrected for the dead times evaluated with this formula and then a variation of these corrected counting data with rime was observed, the results showed quite a good agreement with the published data for the radioactive decay of Mn$^{56}$ . Besides, it appears that the dead time decreases as the count rate increases in a dead time-to-count rate relation obtained by the same formula.

  • PDF

A COMPARATIVE STUDY ON THE POSTSURGICAL CHANGES BETWEEN ONE JAW SURGERY AND TWO-JAW SURGERY IN SKELETAL CLASS III PATIENTS (골격성 III급 부정교합자의 편악수술과 양악수술시 술후동태에 대한 비교연구)

  • Choi, Yang Sook;Son, Won-Sung
    • The korean journal of orthodontics
    • /
    • v.27 no.2
    • /
    • pp.297-313
    • /
    • 1997
  • The purposes of this study were to compare the soft tissue changes following hard tissue change after surgery between the one jaw and two-jaw surgery in skeletal class III patients and to get the reference of the incisal inclination at presurgical orthodontics. For this study 24 patients for the two-jaw surgery group and 18 patients for one jaw surgery group were selected. Lateral cephalograms were taken at pretreatment, after presurgical orthodontic treatment, immediately after surgical treatment and at least 6 months after surgery. They were traced and analyzed on skeletodental structure and soft tissue. The results were as follows: 1. After surgery, maxilla, maxillary incisors and upper lip were moved anteriorly and superiorly in two-jaw surgery group. Mandible and mandibular incisors were moved posteriorly and superiorly, and thickness of lower lip was increased in both group but there were no statistically significant difference. Anterior facial height was more decreased in two-jaw surgery group (p<0.05). At least 6 months after surgery, by the postorthodontic treatment, maxillary incisors were moved labially 1.44mm, mandible and mandiibular incisors were moved lingually 1.43mrn, 1.26mm respectively in one jaw surgery group. But there was no statistically significant changes of hard tissue in two :jaw surgery group. 2. The correlation coefficients of maxillary hard and soft tissue horizontal changes were high in two jaw surgery group and the ratios for soft tissue to A point were 19% at Sri, 80% at SLS, 82% at LS. The ratios for soft tissue to B point were 92% at LI, 104% at ILS in one jaw surgery group, 89% at LI, 101% at ILS in two-jaw surgery group. 3. The correlation coefficients and change ratios of mandibular incisors and LL HS on lower lip horizontal changes were 0 0.89 and 75%, 85% in one jaw surgery group, 0.93, 0.90 and 76%, 87% in two-jaw surgery group. The correlation coefficients of maxillary incisors and Sn, SLS and LS on upper lip horizontal changes were 072, 0.76 and 0.75 in two jaw surgery group and ratios of changes were 57%, 58% and 59%. 4. The regression equations between skeletal horizontal discrepancy and incisal inclinaton were taken in one jaw surgery group. Those were FMIA=57.48-2.17ANB, U1-SN=-75.02+2.17SNB and $R^2$ were 0.63, 063 respectively. So if there is skeletal horizontal discrepancy by mandibular prognathism in one jaw surgery case, we consider attaining more labial inclination of maxillary incisors than normal and more lingual inclination of mandibular incisors than normal. But correlation coefficient of the regression equations in two jaw surgery group was low, so, that equation was not reliable.

  • PDF

Wavelet Based Image Coding Design Using Zerotree (제로트리를 이용한 웨이브렛 기반 영상 부호화 설계)

  • 지연숙;변혜란;유지상
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1998.10c
    • /
    • pp.523-525
    • /
    • 1998
  • 웨이브렛 변환을 사용한 영상은 인간의 시각체계(HVS)에 적적한 양자화 및 부호화를 위한 계층적 구조를 제공한다. 인간의 시각이 민감하게 감지하는 부분을 더 정확하게 부호화 하고, 그렇지 못한 부분에서는 적절한 정보의 손실을 허용하는 원리를 이상적으로 적용할 수 있다. 이런 웨이브렛 변환영상의 통계적 특성을 이용한 제로트리 부호화 기법은 중요한 영상계수를 선별하여 영상전체에서 의미있는 계수를 순서대로 부호화 함으로써 매입 파일(Embeded File)을 생성한다. 본 연구에서는 제로트리 부호화 과정중 불확실 구간(Uncertainty Interval)에서 발생하는 오차(Error)를 줄이기 위하여 LBG(Line Bute Gray) 알고리즘을 도입하여 최적의 오차 코드북을 생성한 후 복원시 사용함으로써 결과의 향상을 보였다. 오차교정(Error Correction)은 EZW(Embeded Zerotee Wavelet) 부호화 과정에서 손실되기 쉬운 고주파수 밴드에 적용하여 복원시 영상의 자세한(detail) 성분을 살리는데 효과적이다. JPEG과 같은 DCT 기반 영상압축 결과에 비하여 화질에서 더 좋은 성능을 보일뿐아니라, DCT 특유의 블록화 현상도 제거되었다.

  • PDF

A/D Converter for Digital Voltmeter (계수형 전압계를 위한 A/D 변환기)

  • No, Hong-Jo;Gang, Jeong-Su;Lee, Gwon-Ha
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.5
    • /
    • pp.1-9
    • /
    • 1971
  • An analog to digital converter Ivhich is applicable to mass production of digital multimeter is developed. The solid state digital instrument has accuracy $\pm$0.1% of feading $\pm$1 digit over 1 mV to 1000 volts with high input impedance and automatic function. All possibility to affect the distortion of A/D converter is tudied. As a result, useful linearity with high temperature stability of integrating waveforms is achieved by the very simplified circuit configuration to assure the proposed accuracy under various ambient condition.

  • PDF

DESIGN OF A RISE TIME DISCRIMINATION CIRCUIT FOR X-RAY PROPORTIONAL COUNTER (X-선 비례계수관용 상승시간 선별회로 제작)

  • 남욱원;최철성
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.1
    • /
    • pp.66-77
    • /
    • 1995
  • It is possible to distinguish X-ray events from non X-ray events in proportional conters using the method of rise time discrimination (RTD). In order to subtract non X-ray background, we have developed a simple RTD circuit which will be applied to the proportional counter planned for a sounding rocket experiment. The entire circuit consists of two parts ; the rise time measurement circuit and the time to amplitude conversion circuit which includes the self-calibration mode. From the test with X-ray detecting system, we obtained that the background can be rejected more than 80% in the energy band 2∼12 keV. However we confirmed that the RDT method is not proper to be used for the energy range above 12kV.

  • PDF

Calibration Techniques for Low-Level Current Measurement in the Characteristic Analysis System for Semiconductor Devices (저전류 측정을 위한 반도체 소자 특성 분석 시스템에서의 보상 기법)

  • Choi, In-Kyu;Park, Jong-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.111-117
    • /
    • 2002
  • In this paper, we proposed calibration techniques to improve measurement accuracy in the characteristic analysis system for semiconductor devices. Systematic errors can be reduced using proposed calibration techniques. Also, error current reduction procedures including leakage current and offset current are proposed to measure low-level current in pA level. Calibration parameters are calculated and stored by microprocessor using least-square fitting with measured sample data. During measurement time microprocessor corrects measured data using stored calibration parameters. Experimental results show that current measurement error above nA level is less than 0.02%. And they also show that current measurement in pA level can be performed with about 0.2% accuracy.

The determinants of vertical overbite and overbite depth indicator(ODI) (수직피개의 결정요인과 수직피개 심도지수(ODI)의 상호관계)

  • Yang, Sang-Duk
    • The korean journal of orthodontics
    • /
    • v.29 no.3 s.74
    • /
    • pp.349-360
    • /
    • 1999
  • The concept of denture frame, both the vertical and horizontal relationship of the dentitions are ultimately related to a skeletal configuration, leads to postulate that the vertical overbite will be determined by the jaw rotations and anteroposterior jaw relationship. Also, ODI is analyzed to be composed of the determinant factors of overbite such as FMA PPA and FABA. From the geometric analyses of an interrelationship between the ODT and the overbite determinants, the following formula can be induced. ODI norm=$85^{\circ} - 0.5 PMA-(1.08 - 0.01 FMA)(FABA - 81^{\circ})$. This formula indicates that the norm of ODI is not constant value but variable one according to the individual skeletal frames. Through the application of the formula to the various clinical cases, it is proved that the new concept, relativity of the ODI norm, is very diagnostically useful.

  • PDF