• Title/Summary/Keyword: 관측망

Search Result 935, Processing Time 0.042 seconds

Investigation of Frost Reduction Effect using Mesh Net (그물망을 이용한 서리 저감 효과 구명)

  • Yu, Seok cheol;Kim, Yu yong;Lim, Seong yoon;Song, Ho sung
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.448-455
    • /
    • 2020
  • This study was carried out to investigate reduction of the frost damage using the mesh net used for the purpose of non-bagged cultivation. A device measuring the weight of frost was developed and installed in both the control and the experimental, and the effect of frost reduction was evaluated with their weights. As a result, weight of frost in the control was reduced from 37% to 59% with mesh net on the day the frost was observed. In addition, the device for automatically observing the amount of frost was developed and the height of the windbreak of the frost measuring device was determined to be 30 cm through wind tunnel experiment. The results of this study are expected to reduce frost damage during the flowering season of fruit trees by installing mesh net and it is expected to be used as basic data for agricultural use of mesh net.

Network Configuration Study for Multi-Satellite Operations (다중위성운영을 위한 네트워크 구성 방안 연구)

  • Baek, Hyun Chul;Jang, In Sik;Lee, Sang Jeong;Kim, Byung Chul;Lee, Jae Yong
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.4
    • /
    • pp.1-9
    • /
    • 2019
  • Integration of satellites with diverse missions, such as broadcast-communication, earth, meteorologicaland marine observations, and navigation, is vulnerable. The problems of the currently constructed ground station network were analyzed by constructing the test environment. Based on this, we designed a network that was capable of operating multiple satellites by one ground station. In addition, we proposed an interface and network configuration method with domestic and foreign ground stations. The network linking the domestic and foreign ground stations was composed of KREONET (Korea Research Environment Open Network) and GLORIAD (Global Ring Network for Advanced Application Development) of the KISTI(Korea Institute of Science and Technology Information). The internal network consists of VPN (Virtual Private Network), DMZ(De-Militarized Zone), and 1-way USB and so forth. By constructing the network by using the proposed method, harmful data, such as virus inflow and infection, can be blocked.

Current State of the Ground Observations for Soil Moisture and Evapotranspiration in 2018 (2018년 토양수분·증발산량 관측소 운영 현황)

  • Kim, Kiyoung;Lee, Yeongil;Jung, Sungwon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.10-15
    • /
    • 2019
  • 국내 수자원 관리의 중요성이 대두되면서 선진화된 하천의 수위, 유량 및 유사량 자료들을 취득할 수 있게 되었으나 제약이 많은 수문 인자로서 인식된 토양수분량과 증발산량에 관한 연구는 비교적 더디게 진행되고 있는 실정이었다. 하지만 최근 토양수분 증발산량 같은 인자들은 대기와 지표 사이의 상호작용에 직접적으로 관여하여 가장 중요한 수문기상학적 인자로 인식되어오면서 많은 프로젝트와 연구들이 진행되고 있다. 2002년 이전 토양수분 증발산량은 학술연구 목적으로 측정하였으며, 그 후 2005년도까지 기관별로 특정 목적을 위해 제한적 측정을 수행하였다. 또한, 한국수자원조사기술원에서도 2007년 하천법에 따라 국가 물 관리에 활용되는 기초 수문 자료생산의 목적으로 증발산량 관측소 2개소, 토양수분량 관측소 2개소를 우선적으로 설치 및 운영을 하고 있었으며, 2015년 이후로 홍수통제소에서도 증발산량관측소를 지속적으로 추가 설치하여 관측망을 구축 운영하고 있다. 이러한 관측소들에서 정기적으로 산출된 데이터들을 축적 및 분석하는 연구들은 장기적인 수문학적 연구로서 중요한 가치이다. 본 연구에서는 2018년 청미천과 설마천 유역에 설치된 증발산량 관측소(Eddy covariance method)와 토양수분량관측소(Time Domain Reflectometer method)에서 관측된 데이터의 특성을 분석하였다. 분석 결과는 유역의 물 순환을 규명하는데 가장 중요한 연구로써 활용될 것으로 기대 된다.

  • PDF

Development of X-Band weather radar quality control technology for non-weather echo removal (비기상에코 제거를 위한 X-밴드 기상레이더 품질관리 기술 개발)

  • Jin-woo Park;Sun-Jin Mo;Ji-Young Gu;Seungwoo Lee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.114-114
    • /
    • 2023
  • 기상레이더는 대류권의 기상 관측에 널리 사용되며, 기상예보를 비롯하여 항공, 농업, 수문학 등 다양한 분야에서 활용하고 있다. 기상레이더센터는 SSPA(Solid State Power Amplifier) 기반 X-Band 주파수대역(9GHz)을 사용하는 연구용 소형기상레이더 관측망을 운영하고 있다. 주로 수도권 저층 대기에서 발생하는 위험 기상현상을 1분 단위로 빠르게 관측하면서 정확한 강수 정보생산을 위한 연구를 수행하고 있다. 레이더 관측 자료는 전파를 이용하여 넓은 범위에 분포하는 눈, 비, 우박 등 대기수상체를 관측하여, 강수량 추정을 통해 강수 정보를 생산한다. 이에 따라 레이더 관측 자료의 정확성과 신뢰도를 높이기 위해서 레이더 품질관리 기술 적용은 필수적이다. 기상레이더센터는 소형기상레이더로 관측한 이중편파 자료의 효과적인 품질관리를 위한 각종 자료처리 모듈을 개발하여, 실시간 자료처리 프로그램에 적용하였다. 우선, 저층 대기 관측 시 기상에코와 더불어 강한 반사도로 나타나는 지형에코를 판별하는 모듈과 선형 또는 쐐기형태의 전파간섭에코를 비롯한 비기상에코를 효과적으로 제거하는 기술을 개발하였다. 다음으로, X-Band 주파수대역 기상레이더 관측 자료의 취약점인 강한 강수 시 발생하는 반사도 감쇠 현상을 보정하기 위한 기술도 개발하였다. 소형기상레이더 품질관리 개발과 적용을 통하여 생산된 자료는 HSR(Hybrid Surface Rainfall), 레이더 강수량 추정, 대기수상체 등 다양한 기상 산출물 생산과 동시에 기상 감시 및 연구 분야에 효과적으로 활용하고 있다.

  • PDF

Development and Observation Result of High Speed Digital Conversion System of Astronomical Radio Siginal (우주 전파 신호의 고속 디지털 변환 장치 개발과 적용)

  • Kang, Yong-Woo;Song, Min-Gyu;Wi, Seog-Oh;Je, Do-Heung;Lee, Sung-Mo;Kim, Seung-Rae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.6
    • /
    • pp.1009-1018
    • /
    • 2017
  • We developed new Digital Sampler for KVN(: Korean VLBI Network). The sampler has 1024MHz sampling frequency with 2bits/sample. The sampler's input reference frequencies are 1pps(: pulse per second) and 10MHz, also UTC(: Universal Time Coordinated) time information out with 1PPS signal, synchronized. The output of sampling data is adapted VSI(: VLBI Standard Interface) specification including the time information. In order to confirm the performance of the sampler, we carried out the astronomical radio observation test in Ulsan Radio Observatory of KVN. It was confirmed the stable performance. In this paper, We introduce the new developed sampler and present the observational test result.

Complexity of Groundwater Flow System in a Site Reflected in the Fluctuations of Groundwater Level and Temperature (지하수위와 수온 변동에 나타난 부지 규모 지하수 흐름장의 복잡성)

  • Jonghoon Park;Dongyeop Lee;Nam C. Woo
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.563-570
    • /
    • 2022
  • This study was objected to show the complexity of groundwater flow system in a site-scale area as a design parameter of the groundwater monitoring network for early detection of pollutant leakage from a potential source of groundwater contamination (e.g., storage tank). Around the tanks, three monitoring wells were installed at about 22~25 m deep and groundwater level and temperature had been monitored for 22 months by 2-minute interval, and then compared with precipitation and temperature data from nearby weather station. Annual variation of groundwater level and its response to precipitation event, variation of groundwater temperature and delayed response to that of atmospheric temperature indicate the complexity of groundwater flow and flow paths even in the relatively small area. Thus, groundwater monitoring network for early detection of contaminant leakage should be designed with full consideration of the complexity of groundwater flow system, identified from the detailed hydrogeological investigation of the site.

Adjustment of 1st order Level Network of Korea in 2006 (2006년 우리나라 1등 수준망 조정)

  • Lee, Chang-Kyung;Suh, Young-Cheol;Jeon, Bu-Nam;Song, Chang-Hyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.1
    • /
    • pp.17-26
    • /
    • 2008
  • The 1st order level network of Korea was adjusted simultaneously in 1987. After that, the 1 st order level network of Korea was adjusted simultaneously by National Geographic Information Institute in 2006. The levelling data were acquired by digital level with invar staff from 2001 through 2006. The 1st order level network consists of 36 level lines. Among them, 34 level lines comprise 11 level loops. Among 36 level lines, 4 level lines have fore & back error larger than the regulations for the 1st order levelling of NGII, Korea. Also, the closing error of 3 loops of level network exceed the regulation for the 1st order levelling of NGII. The standard error of fore and back leveling between bench marks(${\eta}_1$) are distributed between 0.2 $mm/{\surd}km$ and 1.7 $mm/{\surd}km$. The standard error of loop closing(${\eta}_2$) is 2.0 $mm/{\surd}km$. This result means that the 1st order level network of Korea qualifies for the high precision leveling defined by International Geodetic Association in 1948. As the result of the 1st order level network adjustment, the reference standard error($\hat{{\sigma}_0}$) of the level network was 1.8 $mm/{\surd}km$, which is twice as good as that of the 1st adjustment of level networks in 1987.

DEEP SPACE NETWORK MEASUREMENT MODEL DEVELOPMENT FOR INTERPLANETARY MISSION (행성간 탐사를 위한 심우주 추적망 관측모델 개발)

  • Kim, Hae-Yeon;Park, Eun-Seo;Song, Young-Joo;Yoo, Sung-Moon;Rho, Kyung-Min;Park, Sang-Young;Choi, Kyu-Hong;Yoon, Jae-Cheol;Yim, Jo-Ryeong;Choi, Jun-Min;Kim, Byung-Kyo
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.361-370
    • /
    • 2004
  • The DSN(Deep Space Network) measurement model for interplanetary navigations which is essential for precise orbit determination has been developed. The DSN measurement model produces fictitious DSN observables such as range, doppler and angular data, containing the potential observational errors in geometric data obtained from orbit propagator. So the important part of this research is to model observational errors in DSN observation and to characterize the errors. The modeled observational errors include the range delay effect caused by troposphere, ionosphere, antenna offset, and angular refraction effect caused by troposphere. Non-modeled errors are justified as the parameters. All of these results from developed models show about $10\%$ errors compared to the JPL's reference results, that are within acceptable error range.

Performance Test and Analysis of High-Speed Satellite Network Pilot System (고속 위성망 Pilot 시스템 성능시험 결과분석)

  • Hong, Sung-Taek;Shin, Gang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1775_1776
    • /
    • 2009
  • 위성을 이용한 통신 및 방송은 양방향 서비스 시대를 맞이하고 있으며, 위성 인프라는 통신망 back-up 개념을 벗어나 이동 휴대 그리고 지상 인프라 구축 및 운영이 어려운 지역 및 시설을 중심으로 광역통신 및 방송의 근간 망 구성으로 나아가고 있고, 재난 방재 및 긴급 복구, 산업 시설 감시 및 측정데이터 모니터링 등 지상 인프라와 상호 보완적인 이중망 또는 기간망으로 활용되고 있다. 한국수자원공사에도 1998년부터 수문관측망 및 감시제어를 포함한 원격 데이터 취득 및 정보제공 등 많은 부분에 위성통신망을 이용하고 있다. 위성통신망의 사용이 10여년이 지난 시점에서 위성통신장비의 내용년수 도래에 따른 시스템 개선과 대체방안이 필요하게 되었으며, 기존의 수위, 우량과 같은 저용량, 저속인 현재의 위성망에 비하여 기술발전 및 데이터의 다양화에 따른 화상, 동영상과 같은 멀티미디어 데이터 등을 전송할 수 있는 대용량, 고속인 위성망 Pilot 시스템을 구축하였으며, 구축된 시스템에 대하여 성능시험을 한 결과를 분석하고자 한다.

  • PDF

A Study of the Application of Earthquake Early Warning System for the Enhancements in Protective Action by Korea National Park (국립공원의 지진 대응 체계 개선을 위한 지진 조기경보 시스템의 적용에 관한 연구)

  • Yang, Eomzi;Ha, Seong Jun;Kim, Won Kyung;Yun, Tae Sup
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.38 no.3
    • /
    • pp.439-448
    • /
    • 2018
  • Conventional Earthquake Early Warning System (EEWS) detects the propagated P-wave from epicenter which should be achieved within 5 seconds to provide seconds to minutes of warning, allowing people to prepare for protective actions. EEWS in Korea is currently capable of providing a warning within 50 seconds after the primary P-wave detection, however, it is well-known that earthquake warning systems operating around Korean National Parks (KNP) have limited capability to fully monitor earthquake events. This study, therefore, presents a strategy to quantify the potential vulnerability to earthquake hazards by superimposing the distribution of Korea Integrated Seismic System (KISS) and the discretized map of KNP. Total 22 national parks are evaluated, and the results suggest that the improvement of the on-site systems should be necessitated for Gyoengju, Gyeryongsan, Songnisan, Gayasan, and Deogyusan national parks, whereas enhancement of regional systems is required for Bukhansan national park.