• 제목/요약/키워드: 관막음

검색결과 21건 처리시간 0.039초

다관원통형 열교환기의 파울링 현상을 고려한 관막음 여유 평가법 개발 연구 (A Study on the Development of Plugging Margin Evaluation Method Reflected the Fouling of a Shell-and-Tube Heat Exchanger)

  • 황경모;진태은
    • 대한기계학회논문집B
    • /
    • 제28권11호
    • /
    • pp.1384-1389
    • /
    • 2004
  • As operating time of heat exchangers progresses, fouling generated by water-borne deposits and the number of plugged tubes increase and thermal performance decreases. Both fouling and tube plugging are known to interfere with normal flow characteristics and to reduce thermal efficiencies of heat exchangers. The heat exchangers of domestic nuclear power plants have been analyzed in terms of the heat flux and heat transfer coefficient at test conditions as a means of heat exchanger management. Except for the fouling level generated in operation of heat exchangers, also, all of the tubes of heat exchangers have been replaced when the number of plugged tubes exceeds the plugging criteria based on design performance sheet. This paper describes the plugging margin evaluation mettled reflected the fouling of shell-and-tube heat exchangers, which can evaluate the thermal performance for heat exchangers, estimate the future fouling variations, and reflect the current fouling level. To identify the effectiveness of the developed method, the fouling and plugging margin evaluations were performed for a component cooling heat exchanger in a nuclear power plant.

관막음된 증기발생기 전열관의 유체유발진동 특성 평가 (Estimation of Flow-induced Vibration characteristics on Plugged Steam Generator)

  • 조봉호;유기완;박치용;박수기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.921-926
    • /
    • 2002
  • In this study, we investigate the plugging effect on the CE type steam generator tube. The natural frequency and mode shape will be changed due to decrease of the effective mass distribution along the tube. We compared the variation of stability ratio for plugged tube with that for unplugged one. The natural frequency increased because of removing the cooling water inside the steam generator tube, but the stability ratio decreased inversely because of changing the vibrational model shape. We also investigated the turbulent excitation effect.

  • PDF

관막음된 증기발생기 전열관의 유체유발진동 특성 평가 (Estimation of Flow-induced Vibration Characteristics on Plugged Steam Generator Tube)

  • Cho, Bong-Ho;Ryu, Ki-Wahn;Park, Chi-Yong;Park, Su-Ki
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.390.1-390
    • /
    • 2002
  • In this study, we investigate the plugging effect on the CE type steam generator tube. The natural frequency and mode shape will be changed due to decrease of the effective mass distribution along the tube. We compared the variation of stability ratio for plugged tube with that fur unplugged one. The natural frequency increased because of removing the cooling water inside the steam generator tube, but the stability ratio decreased inversely because of changing the vibrational mode shape. We also investigated the turbulent excitation effect.

  • PDF

집단 관막음된 한국표준원전 증기발생기 전열관의 유체탄성불안정성 특성 평가 (Estimation of Fluid-elastic Instability Characteristics on Group Plugged KSNP Steam Generator Tube)

  • 조봉호;유기완;박치용;박수기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.670-676
    • /
    • 2003
  • To investigate the group plugging effect the fluid-elastic instability analysis has been performed on various column and row number of the KSNP steam generator lutes. This study compares the stability ratio of the plugged tube with that of the intact one. The information on the thermal-hydraulic data of the steam generator have been obtained by using the ATHOS3-MOD1 code with and without the thermal energy transfer at the plugged region. Both of the boundary conditions of hot-leg temperature and feedwater mass flow rate are fixed for this investigation. From the results of this study the stability ratios inside the group plugging zone are decreased slightly. At the outside of group plugging zone, however, most of the stability ratios tend to be increased.

  • PDF

원전 증기발생기 전열관 관막음 한계 고찰 (A Review of Plugging Limit for Steam Generator Tubes in Nuclear Power Plants)

  • 강용석;이국희
    • 한국압력기기공학회 논문집
    • /
    • 제16권2호
    • /
    • pp.10-17
    • /
    • 2020
  • Securing the integrity of steam generator tubes is an essential requirement for safe operation of nuclear power plants. Therefore, tubes that do not satisfy integrity requirements are no longer usable and must be repaired according to the related requirements. In general, the repair criterion is that the damage depth is more than 40% of the tube wall thickness. However, the plugging limit can be changed and be applied, provided a technical proof is given that integrity can be secured against specific degradation at a specific plants and that approval can be obtained from a regulatory agency. A typical example is alternative repair criteria for defects within the tube sheet or tube support plates. In this paper, a background of establishing the plugging limit for steam generator tubes and changes in maintenance criteria are reviewed as examples.

다관원통형 열교환기의 파울링 및 관막음 여유 평가법 (A Study on the Development of Fouling and Plugging Margin Evaluation Methods for Shell-and-Tube Heat Exchangers)

  • 황경모;진태은
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.55-60
    • /
    • 2003
  • As operating time of heat exchangers progresses, fouling generated by water-borne deposits increases and thermal performance decreases. The fouling is known to interfere with normal flow characteristics and reduce thermal efficiencies of heat exchangers. The heat exchangers of nuclear power plants have been analyzed in terms of the heat flux and heat transfer coefficient at test conditions based on the ASME OM-S/G-Part 2 as a means of heat exchanger management. It is hard to estimate the heat performance trend and to establish the future management plan. This paper describes the fouling evaluation method which can evaluate the thermal performance for heat exchangers and estimate the future fouling variations and the plugging margin evaluation method which can reflect the current fouling level developed in this study. To develop the fouling and plugging margin evaluation methods for heat exchangers, fouling factor was introduced based on the ASME O&M codes and TEMA standards. For the purpose of verifying the two evaluation methods, the fouling and plugging margin evaluations were performed for a component cooling heat exchanger in a nuclear power plant.

  • PDF

한국표준원전 증기발생기의 관막음 집중 영역 근방에서의 유체유발진동 특성해석 (Characteristics of Flow-induced Vibration for KSNP Steam Generator Tube at Concentrated Tube Plugging Zone)

  • 유기완;조봉호;박치용;박수기
    • 한국소음진동공학회논문집
    • /
    • 제13권6호
    • /
    • pp.452-459
    • /
    • 2003
  • The characteristics of fluid-elastic instability and effects of turbulent excitations for the KSNP steam generator tubes were investigated numerically. The information for the thermal-hydraulic data of the steam generator has been obtained by using the ATHOS3-MOD1 code and the flow-induced vibration(FIV) analysis has been conducted by using the PIAT(program for Integrity assessment of SG tube) code. The KSNP steam generator has the concentrated plugging zone at the vicinity of the stay cylinder inside the SG. To investigate the cause of the concentrated tube plugging zone, the FIV analysis has been performed for various column and row number of the steam generator tubes. From the results of FIV analysis the stability ratio due to the fluid-elastic instability and vibrational amplitude due to the turbulent excitation in the concentrated plugged zone have a trend of larger values than those of the outer concentrated tube Plugging zone.

I-형 마멸 손상된 증기발생기 전열관의 파열압력해석

  • 신규인;박재학;정명조;최영환
    • 한국산업안전학회:학술대회논문집
    • /
    • 한국안전학회 2003년도 추계 학술논문발표회 논문집
    • /
    • pp.38-43
    • /
    • 2003
  • 증기발생기 전열관의 마멸은 유체 유발 진동(flow induced vibration)에 의한 전열관과 증기발생기 상부 지지구조물 사이에서 발생하게 되며 원통 지지대(stay cylinder)상부의 중앙 공공(central cavity) 주변에 집중적으로 발생되는 것으로 보고되고 있다. 국내에서는 1997년 영광 4호기의 증기발생기에 마멸 손상이 보고된 이후 영광 3호기와 울진 3, 4호기에서도 마멸 손상이 발견되고 있으며, 외국에서는 1992-1993년 기간동안 대략 500∼600 개의 전열관이 마멸에 의해 관막음(p1u99ing)된 것으로 보고되었다.(중략)

  • PDF