• Title/Summary/Keyword: 과도장력

Search Result 28, Processing Time 0.033 seconds

Analysis of the Transient Dynamic Response of Ocean Mining Pipe System Due to Impulse (임펄스 가진에 의한 근해역 통합채광시험 양광시스템의 파이프 동적 과도응답 해석)

  • Cho, Kyu-Nam;Kim, Min;Park, Yong-Chan;Yoon, Chi-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.2
    • /
    • pp.105-111
    • /
    • 2007
  • A finite element analysis scheme is proposed to assess the dynamic response due to impulse excitation of ocean mining pipe system. Transient dynamic response analysis based on the proposed scheme was carried out for various types of impulses, and the magnitude of cable tension induced by impulse was discussed by using a model of 'Segero', a special purpose ship of KT-Submarine as well as ROV carrier 'Onnuri' A qualitative, prospective guideline for the relevant marine operation is obtained.

Transient Effects of Wind-wave Hybrid Platform in Mooring Line Broken Condition (부유식 파력-해상풍력 복합발전 구조물의 계류선 손상 시 과도 응답 해석)

  • Bae, Yoon Hyeok;Lee, Hyebin
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.2
    • /
    • pp.129-136
    • /
    • 2016
  • Floating offshore structures keep its position by a mooring system against various kind of environmental loadings. For this reason, a reliable design of the mooring system is a key factor for initial design stage of a floating structure. However, there exists possibility of mooring failure, even the system is designed with enough safety margin, due to the unexpected extreme environmental conditions or long-term fatigue loadings. The breaking of one of the mooring lines may change the tension level of the other mooring lines, which can potentially result in a progressive failure of the entire structure. In this study, time domain numerical simulation of 10MW class wind-wave hybrid platform was carried out with partially broken mooring line. Overall platform responses and variations of the mooring line tension were numerically evaluated.

Development of Magnetic Sensor for Measurement of the Cable Tension of Large Scale Bridge (대형교량 케이블 장력 측정을 위한 자기센서 개발)

  • Park, Hae-Won;Ahn, Bong-Young;Lee, Seung-Seok;Kim, Jong-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.339-344
    • /
    • 2007
  • Safety of large scale cable in bridge is very important because it may cause the unwanted catastrophic failure. Although the proof load were considered at the design stage, its soundness must be monitored continuously because the cable may be broken out without warning by the variable external load. The cable tension of in-use structures has been mainly measured by the resonance method and its use has been limited because of relatively large measurement uncertainty. Recently a new magnetic method was developed and its reliability is known to be good for evaluating the cable tension. In this study a system which can deliver the calibrated load to the cable was developed and the measurement reliability of developed magnetic sensor according to the change of external load was analyzed quantitatively. The effect of magnetization frequency, bias magnetic field, and temperature on the sensor output was also evaluated.

Dynamic Analysis of Long Distance Belt Conveyor System (장거리 벨트 컨베이어 시스템의 동적거동 해석)

  • 김원진;박태건;이신섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.307-312
    • /
    • 1995
  • 장거리 시스템의 경우에 있어서 기동과 정지 시의 동적하중은 구동부 입력크기의 변화와 구동부간이 기동 시간차이로부터 발생되며, 벨트로 전파되어 장력변화를 일으키고, 과도한 장력의 변화는 인장과 압축의 탄성파로 벨트요소의 응력을 증가시키며, 벨트, 풀리, 아이들러(idler)등의 벨트요소들을 파괴시킨다. 따라서 동적해석에 의한 설계가 필수적으로 요구되어 벨트의 동적거동 해석에 대한 연구가 많이 수행되고 있다. 본 연구에서는 벨트 컨베이어 시스템을 집중질량모델(lumped mass model)로 근사하여 모델링하는 방법을 도입하여 세부요소에 대한 운동방정식을 유도하고, 각 요소 모델링을 결합하여 전체 운동방정식을 수립하였으며, 예제 시스템에 적용하여 동적거동을 해석하였다. 예제 시스템에 있어서 기동시의 구동입력을 두 가지 형태의 입력을 이용하였고, 정지시에는 구동부 브레이크가 없는 경우로 정상운전상태에서 순간적으로 구동부의 동력을 제거하는 방법을 적용하였다. 시뮬레이션 결과를 통하여 기동시의 구동입력을 적절히 제어하므로 벨트 속도와 장력의 변화를 줄일 수 있는 입력형태를 결정할 수 있었고, 이 때의 테이크업의 운동도 구할 수 있었다.

  • PDF

Effects of Sulfonation Ratio in Petroleum Sulfonate Synthesis on Interfacial Properties and on Fluidity Properties of Cement Mortar (Petroleum Sulfonate의 합성에 있어서 황산화율이 계면활성 특성 및 시멘트 몰타르의 유동성에 미치는 영향)

  • Kim, Young-Ho
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.444-449
    • /
    • 2010
  • In this study, the petroleum sulfonate(PS) was synthesized from pyolyzed fuel oil by sulfonation reaction with sulfuric acid. The PS synthesized had surfactant behaviors relating to the interfacial properties such as surface tension, surface adsorption, and wetting, etc. These interfacial properties were affected by the sulfonation ratio in the synthesis. As the sulfonation ratio increased, the surface tension of the PS aqueous solution decreased. However, when the ratio was too high, the surface tension was increased due to the extremely higher value of hydrophilicity of PS. At the optimum sulfonation ratio, the PS had a good wettability on the cement particles and a good fluidity of the cement mortar with a high adsorption.

Shear Force Variation of Stiffening Girder caused by Vibration of Stay Cable (사장 케이블 진동에 의한 보강형의 전단력 변화)

  • Kim, Hyeon Kyeom;Hwang, Jae Woong;Lee, Myeong Jae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.1A
    • /
    • pp.1-8
    • /
    • 2009
  • Stay cable is easily exposed to vibration induced rainy wind effects. There are some problems for not only unexpected vibration but also well-known vibration. An outbreak of displacement by the said effects brings damages such as over-tension of cables and barriers, fatigue of anchorages and dampers, and additional shear force variation of stiffening girders. This study suggests analytic methodology for dynamic tension variation of cables and shear force variation of stiffening girders. Additionally this study announces with dynamic problems for cable stayed bridge briefly. To realize this subject, we divide restoring force into chord component and normal component and then make up the differential equations which can satisfy physical phenomenon for each component. Finally we apply adequate functions such as sinusoidal and parabola in order to reduce these differential equations. Therefore we can meet with good results through a series of above process. As a remarkable result, CIP recommendations (2002) give inadequate solution with over 10% error. However it gives very good solution if parts of our study are reflected at the said recommendations. The fact means that CIP recommendations (2002) well-known as international standard of stay cables are not even concern about this subject yet. For verification of this study, F.E. analysis using E.C.C. with external forces was fulfilled, and the accuracy and conciseness of this study were shown.

Cable Adjustment of Composite Cable Stayed Bridge with Fuzzy Linear Regression Analysis (선형퍼지회귀분석기법을 이용한 합성형 사장교 케이블의 장력보정)

  • Kwon, Jang Sub;Chang, Seung Pil;Cho, Suh Kyoung
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.4 s.33
    • /
    • pp.579-588
    • /
    • 1997
  • During the construction of cable stayed bridge, errors are always caused by various reasons, accumulated and amplified through the complex construction steps. It is likely that the undesirable stress distribution of members and the large deflection of the bridge different from design values come out The adjustment of cables during construction is absolutely indispensable to correct the stress distribution of the members and the geometrical configuration of the bridge. In the conventional method, weight coefficients are used to consider the difference of units between cable forces and girder deflections during the optimization process of cable adjustment. However, it is not easy to determine weight coefficients and the adjustment must be repeated several times with the time consuming process of the determination of new weight coefficients in case that errors are out of design allowable limits. In this paper, fuzzy linear regression analysis is applied to the cable adjustment to overcome those problems. In the application of fuzzy linear regression analysis method the designer's intention and the design allowable limits can be formulated in the form of the constraints of the linear optimization problem. Therefore, the cable adjustment in construction site can be carried out with the fuzzy linear regression analysis more rapidly than with the convetional method.

  • PDF

Dynamic Analyis of Long Distance Belt Conveyor During Starting and Stopping (장거리 벨트 컨베이어의 기동 및 정지시의 동적거동 해석)

  • Kim, Won-Jin;Park, Tae-Geon;Lee, Shin-Sup
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.2
    • /
    • pp.585-593
    • /
    • 1996
  • According to the considerable increase of the length of belt conveyors, the dynamic analysis of systme becomes necessary to consider the variation of tensions and transient motion of components during starting and stopping of conveyor. The mathematical model of system is derived using the lumped parameter method. The input driving force is represented with two functions of time and pulley speed to count the characteristics of motor and fluid coupling. An example system was studied with 14 km in the distance of carrying. At head, it has two drivers and one gravity take-up and at tail ond driver and one power winch take-up. In the example, the transient tensions and responses, calculated using two cases of driving force, are mutually compared in starting mode. Also, the position of maximum tension and the braking force of take-up are obtained in stopping mode.

Experimental study on stripping mechanism of tension controlled bolts (TC볼트의 스트리핑 메카니즘에 대한 실험적 연구)

  • 신근하
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.9 no.1
    • /
    • pp.111-118
    • /
    • 2000
  • Over tightening experiments of the tension-controlled bolts are carried out and the stripping mechanism is reviewed base on the observed results. There are two modes of bolt failure due to the over tightening : one the fracture of the bolt the other the thread stripping Bifurcation between these two modes is rather delicate but it seems being related with the elastic flexibility of the bolt which depends upon the unused thread length. The fracture mode occurs in the bolts with good flexibility while the latter with bad one. According to the ISO Standard some meter coarse threads like M20 and M22 have the same pitch which causes bigger fastener to less resistance in shear and bending compared with the smaller one. however since UNC thread system adapts different pitch for different nominal diameter unified coarse threads show better stripping resistance than their corresponding meter threads.

  • PDF