• Title/Summary/Keyword: 과도응답 제어

Search Result 206, Processing Time 0.035 seconds

Improvement of Transient Response Characteristics of Pneumatic Manipulator using MR Brake (MR Brake를 이용한 공압 머니퓰레이터의 과도응답특성의 향상)

  • Ahn K.K.;Song J.Y.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.1 no.1
    • /
    • pp.17-22
    • /
    • 2004
  • The goal of this paper is to improve the position control performance of pneumatic rotary actuator with variable brake using Magneto-Rheological Fluid. The air compressibility and the lack of damping of the pneumatic actuator bring the dynamic delay of the pressure response and cause the oscillatory motion. In this study, a variable rotary brake comprising Magneto-Rheological Fluid is equipped to the joint of a pneumatic manipulator. Experiments of step response have proved that the transient response of the manipulator could be improved compared with that of the conventional control algorithm by using a phase plane switching control algorithm.

  • PDF

A Study on Control Algorithm of a Switching Device for Junction of Photovoltaic Modules by Using Soft Starting (소프트 스타팅을 이용한 태양광모듈 접속장치용 스위칭 소자의 제어기법에 관한 연구)

  • Kim, Eun-Soo;Ha, Yong-Ho;Hwang, Seon-Hwan;Lee, Jaeseok
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.306-307
    • /
    • 2017
  • 본 논문에서는 태양광모듈과 전력변환장치간의 접속장치로 사용된 전력용 반도체 스위칭 소자의 소프트 스타팅 기법을 통해 초기 돌입전류를 저감하는 알고리즘을 제안하고자 한다. 태양광 모듈의 경우, 릴레이나 DC차단기 등을 사용하여 전력변환장치와 연동하는 것이 일반적이나, 이 경우 태양광모듈의 수명과 접속장치의 전압 강하 및 응답성 등의 문제를 야기한다. 또한, 전력변환장치 출력단의 커패시터에 초기 동작 시 과도한 동일전류가 발생하게 되고 이는 태양광모듈의 과전류 현상을 발생시켜 모듈의 수명과 더불어 퓨즈의 차단 및 발열 등 비이상적인 현상을 발생시킨다. 따라서, 본 논문에서는 이러한 문제점을 해결하고자 스위칭 소자를 사용한 접속장치 적용하였고, 소프트 스타팅 기법을 이용하여 돌입전류를 저감하고자 한다. 제안한 알고리즘의 경우, 시뮬레이션을 통해서 검증하고자 한다.

  • PDF

The Improvement of the transient Response Using the Switching Property of Multiple Control Systems. (다중 제어 시스템의 스위칭 특성을 이용한 과도 응답 개선)

  • Rhee, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.1100-1103
    • /
    • 1996
  • A well-known problem in adaptive control is the poor transient response which is observed when adaptation is initiated. This paper proposes a useful method to improve the transient response of adaptive control systems by using multiple models of the plant and switching mechanism by fuzzy inference. The models are identical except for initial estimates of the unknown plant parameteres. The control input to be applied is determined at every instant by the model which best approximates the plant. Simulation results are presented to indicate the performance improvement of adaptive control systems using the proposed method.

  • PDF

Preliminary Validation of Wind Turbine Generator System Performance Analysis S/W, WINSIM (풍력발전시스템 성능 해석 S/W의 초기 검증에 관한 연구)

  • Mun, Jung-Heu;No, Tae-Soo;Park, Jong-Hyuk;Kim, Sung-Ju
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.2
    • /
    • pp.209-214
    • /
    • 2009
  • The simulation software for predicting the performance of a wind turbine generator system (WTGS) is validated using the field measured data obtained from the idling test run of a dual rotor wind turbine recently developed and installed in Korea. Both steady-state and transient responses at low and high wind conditions are compared with the theoretically predicted ones from the simulation software WINSIM.

A fast transient control of EDPA gain on channel add/drop WDM networks (채널 가감 파장분할다중(WDM)망에서 EDFA 이득의 빠른 과도 응답 제어)

  • Park Jungmoon;Lee Sangheon;Shin Seoyong;Song Seongho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.4A
    • /
    • pp.233-240
    • /
    • 2005
  • In this paper, we have shown the gain recovery time of erbium-doped fiber amplifier(EDFA) in WDM add/drop networks can be reduced to less than $3\mu$sec by employing disturbance observer technique with PID controller which is based on 3-level EBFA model. The $3\mu$sec transient time is the fastest one ever reported and it is about $1\%$ of $250\mu$sec previously obtained from disturbance observer technique with PI controller which was based on 2-level EDFA model and it is also less than $200\mu$sec of commercially available EDFAs for WDM networks. We were able to obtain this result by analyzing various system characteristics as we change the parameters of disturbance observer and PID controller. If this result is applied to a commercial product, the product will do an important role in the future dynamic WDM networks.

Seismic Responses Control of Coupled Shear Wall Structures Using LRBs (LRB를 이용한 병렬전단벽 구조물의 지진응답제어)

  • Park, Yong-Koo;Kim, Hyun-Su;Ko, Hyun;Kim, Min-Gyun;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.1-9
    • /
    • 2010
  • Most of shear wall structures require openings in shear walls and thus shear walls are linked by floor slabs or coupling beams resulting in the coupled shear wall structures. When these structures are subjected to seismic excitations, excessive shear forces are induced in coupling beams. Accordingly, brittle failure of coupling beams may occur or shear walls may yield first. To avoid this problem, damping devices can be installed in coupling beams. It can increase the vibration control effect and improve the seismic resistance performance of the coupled shear wall structure by avoiding stress concentration and the brittle failure of coupling beams. Based on this background research, an LRB (lead rubber bearing) was introduced in the middle of the coupling beam in this study and the authors investigated the seismic response control effect and stress distribution of the proposed system. To this end, a modeling technique that can effectively predict the structural behavior of coupled shear wall structures has been proposed. With this proposed technique, time history analyses of the example coupled shear wall structure subjected to seismic excitation were performed and the vibration control effects of the seismic responses were investigated.

A Study on the Characteristics of Thyristor Controlled Shunt Compensator (싸이리스터제어 병렬보상기의 특성 연구)

  • 정교범
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.368-376
    • /
    • 1999
  • This paper studies the operational characteristics of thyristor controlled shunt compensator in a simple power t transmission system. With Fourier series representation of the thyristor switching action and the system parameters, t the thyristor current equations are derived, which transmit the required real power of the simple power transmission s system. Bisection algorithm is used to solve the thyristor current equations, which informs the thyristor firing an밍e, t the thyristor conduction an밍e, the power flows and the harmonic characteristics. The stability analysis is performed w with the theory of Poincare mapping for the nonlinear discrete periodic dynamic system. EMTP simulations at the v various operating points show the transient characteristics of the thyristor controlled shunt compensator and C correspond to the results calculated with Fourier series representation and the stability analysis.

  • PDF

Tuning-free Anti-windup Strategy for High Performance Induction Machine Drives (고성능 유도전동기 구동을 위한 자동 튜닝 Anti-windup 기법)

  • Seok Jul-Ki;Lee Dong-Choon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2005
  • This paper presents a tuning-free conditional integration anti-windup strategy for induction machine with Proportional-Integral(PI) type speed controller. The on/off condition of integral action is determined by the frequency domain analysis of machine torque command without a prior knowledge of set-point changes. There are no tuning parameters to be selected by users for anti-windup scheme. In addition, the dynamic performance of the proposed scheme assures a desired tracking response curve with minimal oscillation and settling time even in the change of operating conditions. This algorithm is useful in many high performance induction machine applications not to allow the oscillation and overshoot of speed/torque responses. The main idea can be extended to general applications such as chemical processes and industrial robots.

Instantaneous Voltage Control Scheme of Auxiliary Power Supply System for Electric Railway Vehicles (철도차량 보조전원장치의 순시전압제어)

  • 김재식;최재호;임성수;이은규
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.349-356
    • /
    • 1999
  • This paper presents an instantaneous voltage control scheme of au킹liary power supply system for the electric railway v vehicles, The resonance problem of the LC filter and the existing steady state error are more serious as the use of l instantaneous voltage control techniques for the fast transient response at the nonlinear load, A filter capacitor current f feedback loop is considered to increase the damping ratio of the voltage transfer function for the suppression of the resonance problem of the LC inverter output filter. To eliminate the steady state en‘or existing in case of the AC l instantaneous voltage control. the high gain transfer function is added to the conventional PI controller. The theoretical a analysis is well described with the simulation results. The validity of the proposed schemes is well verified through the s simulation and expelimental results for the 5 kVA prototype.

  • PDF

A Study on Cooling Effect and Power Control of a Mini Ozonizer (소형 오존발생장치의 전력제어와 냉각효과에 관한 연구)

  • Woo, Sung-Hoon;Park, Seung-Cho;Yoon, Sung-Yoon;Park, Jee-Ho;Woo, Jung-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.1
    • /
    • pp.97-103
    • /
    • 2006
  • In this paper, a control method of a mini ozone generator is proposed, and also a cooling technique is described which is cooling down the flowing air gap into a silent discharger to $2^{\circ}C$ to generate ozone of high density and diffusing power. As the digital control system for this method, a double feedback loop is designed which detects the voltage and current of equivalent capacitor of the discharger and compensates for the poor power waveform caused by the noise at high discharging frequency. During the plant modeling of this system, computing time factor is considered as a unique parameter of the power system to improve the transient responses with regard to fluctuating load and to replenish the computing time delay of the controller. Through the experiment, sinusoidal input current for discharger can be acquired and all the effectiveness of this accurate control system over unstable ozone discharger are proved.