• Title/Summary/Keyword: 공시체 콘크리트

Search Result 264, Processing Time 0.026 seconds

Axial Behavior of Concrete Cylinders Confined with FRP Wires (FRP 와이어 보강 콘크리트 공시체의 압축거동)

  • Cho, Baiksoon;Lee, Jong-Han;Choi, Eunsoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.5
    • /
    • pp.1765-1775
    • /
    • 2013
  • The application of FRP wire as a mean of improving strength and ductility capacity of concrete cylinders under axial compressive load through confinement is investigated experimentally in this study. An experimental investigation involves axial compressive test of three confining amounts of FRP wire and three concrete compressive strengths. The effectiveness of FRP wire confinement on the concrete microstructure were examined by evaluating the internal concrete damage using axial, circumferential, and volumetric strains. The axial stress-strain relations of FRP wire confined concrete showed bilinear behavior with transition region. It showed strain-hardening behavior in the post-cracking region. The load carrying capacity was linearly increased with increasing of the amount of FRP wire. The ultimate strength of the 35 MPa specimen confined with 3 layer of FRP wire was increased by 286% compared to control one. When the concrete were effectively confined with FRP wire, horizontal cracks were formed by shearing. It was developed from sudden expansion of the concrete due to confinement ruptures at one side while the FRP wire was still working in hindering expansion of concrete at the other side of the crack. The FRP wire failure strains obtained from FRP wire confined concrete tests were 55~90%, average 69.5%, of the FRP wire ultimate uniaxial tensile strain. It was as high as any other FRP confined method. The magnitude of FRP wire failure strain was related to the FRP wire effectiveness.

Investigation on Failure Behavior of Varying Ratios of Recycled Aggregate (순환골재 치환률에 따른 압축강도 비교분석)

  • Jang, Hoon;Chung, Wonseok;An, Zu-Og
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.160-160
    • /
    • 2011
  • 현대의 건설기술은 자원절약과 환경보전이라는 시대적 흐름 속에, 자원순환과 지속 가능한 친환경 건설기술 개발은 차세대 연구분야로써, 연구가 시급한 분야가 되었다. 최근에는 골재 수급불균형 문제를 해결하고 동시에 자원순환을 위한 방안으로서 건설폐기물로부터 생산된 순환골재를 콘크리트용 천연골재의 대체재로 활용하기 위한 연구개발이 이루어지고 있다. 지속가능형 건설기술을 국내 독자 기술로 확립하고 건설현장에서 발생하는 폐기물의 순환시스템을 확고하게 구축하여 순환자원에 의한 국가경쟁력 강화를 기대할 수 있다. 본 연구의 목적은 순환골재 콘크리트의 역학적 특성을 개선하기 위해 순환골재 콘크리트 공시체를 제작하여 강도 및 강성을 검증하는 것이다. 실험방법으로 순환굵은골재의 치환 비율을 0%에서 100%까지 변화시킨 공시체를 제작하고 각 공시체의 정적 극한강도 거동을 비교 분석하였다. 하중은 공시체가 파괴가 발생 할 때까지 변위제어 방식으로 재하 하였으며 이 때 공시체의 파괴거동은 설치된 계측센서들을 이용하여 계측 및 분석하였다. 실험결과 공시체의 압축강도는 순환굵은골재 치환률이 25% 미만일 경우 일반 콘크리트 압축강도의 95% 이상의 구조성능을 갖지만, 순환굵은골재 치환률이 100%인 경우, 일반콘크리트 압축강도의 85% 수준의 구조성능을 나타냈다. 강성은 FRP 부재의 순환골재 치환률에 따라 최대 14%의 강성차이를 보였다. 이를 통해 순환골재 치환률이 높을수록 순환골재 표면의 폐모르타르와 이물질의 영향으로 재료간의 부착강도가 감소되어 강도와 강성이 저하되었음을 확인하였다.

  • PDF

Axial Load Behavior of Concrete Cylinders Confined with Fiber-Sheet and Steel-Plate Composites Plate (FSP) (섬유-강판 복합플레이트로 보강된 콘크리트 압축부재의 압축성능)

  • Cho, Baik-Soon;Choi, Eunsoo;Chung, Young-Soo;Kim, Yeon-Wook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.4A
    • /
    • pp.331-340
    • /
    • 2011
  • The application of newly developed fiber-sheet and steel-plate composite plate (FSP) as a means of improving strength and ductility capacity of concrete cylinders under axial compression load through confinement is investigated experimentally in this study. An experimental investigation involves axial load tests of two types of FSP strengthening material, two anchoring methods, and three concrete strengths. The FSP-confined cylinder tests showed that FSP provided a substantial gain in compressive strength and deformability. The performance of FRP-confined cylinders was influenced by type of the FSP strengthening material, the anchoring method, and concrete compressive strength. The FSP failure strains obtained from FSP-confined cylinder tests were higher than those from FRP-confined cylinder tests. The magnitude of FSP failure strain was related to the FSP composite effectiveness. The effects of FSP confinement on the concrete microstructure were examined by evaluating the internal concrete damage using axial, radial, and volumetric strains. From the observations obtained in this investigation, it is believed that FSP is one of the best solutions for the confinement of concrete compressive members.

Studies on the evaluation method of structural concrete strength using joint separation test body (접합분리 시험체를 사용한 구조체 콘크리트 강도 평가에 관한 실험적 연구)

  • Kim, Seong-Deok;Lee, Seon-Ho;Kim, Kwang-Ki;Jung, Kwang-Sik;Lim, Nam-Ki;Jung, Sang-Jin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.993-996
    • /
    • 2008
  • It has been reported that destruction test by core collection is the most reliable of the structural concrete strength in present building construction field. But it causes low efficiency by damage and cutting in structure due to the core collection. It also has some problems in repairing. Additionally in case of strength test with management specimen, different environment compared to the structure environment cause problems about estimation precise structure strength. Therefore, it is required to develop structure direct strength test that has test values and credibility above the ones obtained by core specimen collection strength test and seasonal specimen test to suggest a reasonable and practical management method of structural concrete.

  • PDF

Effect of Specimen Sizes and Shapes on Compressive Strength of Concrete (콘크리트의 압축강도에 공시체의 크기와 형상이 미치는 영향)

  • Yang Eun-Ik;Choi Joong-Cheol;Yi Seong-Tae
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.3 s.81
    • /
    • pp.375-382
    • /
    • 2004
  • The compressive strength of concrete is used as the most basic and important material Property when reinforced concrete structures are designed. It has become a problem to use this value, however, because the control specimen sizes and shapes are different from every country. In this study, the effect of specimen sizes and shapes on compressive strength of concrete specimens was experimentally investigated based on fracture mechanics. Experiments for the Mode I failure was carried out by using cylinder, cube, and prism specimens. The test results are curve fitted using least square method(LSM) to obtain the new parameters for the modified size effect law(MSEL). The analysis results show that the effect of specimen sizes and shapes on ultimate strength is apparent. In addition, correlations between compressive strengths with size, shape, and casting direction of the specimen are investigated. For cubes and prisms the effect of placing direction on the compressive strength was investigated.

Estimation of Concrete Strength Based on 7-day Strength (콘크리트의 7일강도를 이용한 28일 강도의 추정)

  • 김선영;권태수;이수곤
    • Magazine of the Korea Concrete Institute
    • /
    • v.10 no.1
    • /
    • pp.119-124
    • /
    • 1998
  • 콘크리트는 시멘트, 잔골재 및 굵은 골재, 물 및 첨가제의 양이나 투입순서 ,혼합방법등 여러 가지 요인에 따라 성질이 바뀌게 되는 복합재료이다. 따라서 넓은 의미에서 품질 판정의 한 수단이 되는 콘크리트의 설계기준강도 또는 압축강도 fc'(=28일 압축강도)는 물론 기타의 성질도 정확한 예측이 불가능하다. 즉 소요강도를 목표로 배합된 공시체의 시험결과는 예외없이 통계적 가변성을 나타낸다. 여기에서는 공시체의 7일 강도의 평균치 및 표준 편차와 공시체의 28일 강도 측정치로부터 콘크리트의 압축강도를 추정하는식을 제안하였다. 이를 위하여 7,320개의 강도시험자료를 수집한 후 이들을 선형 회귀 분석법으로 처리하였다. 제안된 식에 의한 콘크리트의 압축강도는 타 추정식에 의한 값보다 실측치에 좀 더 근접함을 보여주었다. 또한 제안식의 검정을 위해 서울지역 자료 5,200개를 수집하여 제안식과 JIS, Slater식과의 오차를 비교한 결과에 따르면 제안식이 더 안전측임을 알 수 있었다. 그리고 슈미트 햄머에 의한 현장 실측 강도와 제안식과의 콘크리트 강도 오차는 대체로 2.3%이었다.

The Properties of Compressive Strength of Non-standard Specimens Considered Strength Level (강도수준을 고려한 비표준형 공시체의 압축강도 특성)

  • Lee, Seung-Han;Jung, Yong-Wook;Yun, Yong-Ho;Jang, Seck-Soo;Yeo, In-Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.781-784
    • /
    • 2008
  • Recently as application of high-strength concrete on concrete structures has been on the rise, use of non-standard specimen is increasing. Therefore, this study investigated the effect of specimen's size effect, ratio of height/diameter and curing conditions on concrete compressive strength. Results of experiments showed that as size of specimen increased as much as 1 mm, standard design compressive strength of 24MPa fell as much as0.15MPa 40MPa fell as much as 0.1MPa 80MPa fell as much as 0.3MPa, and it indicates that as the level of strength is intensified, the decrement of compressive strength increases. As ratio of height/diameter increased as much as 1.0, compressive strength of 24MPa fell as much as 2.9MPa 40MPa fell as much as 3.7MPa 80MPa fell as much as 9.8MPa, and it means that as strength of concrete is higher, influence of ratio of height/diameter becomes bigger.

  • PDF

A Study on the Strength Properties of High-Strength concrete under Various curing conditions (각종 양생방법에 따른 고강도 콘크리트의 강도발현 특성에 관한 연구)

  • Cho, Hyun-Dae;Jaung, Jae-Dong
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.965-968
    • /
    • 2008
  • The KS F 2403 method used on domestic sites for checking the compressive strength of a structure, sets the compressive strength of the concrete used in structural specimens as the compressive strength of testing specimens. Under this regulation, the curing method used for testing the specimens must be the standard ponding curing method (20$\pm$2$^{\circ}$C). However, because in-placed concrete is exposed to open air and cured under the seasonal temperature changes, the compressive strength of a real structure is different from the tested compressive strength. (Therefore,) This thesis first identifies the distinct characteristics of the strength development by applying the curing method listed under the KS and used for testing specimens on compressive strength tests; the atmospheric curing method, the sealed curing method, and the structural specimen core strength testing methods used for the in-sites quality checks including reckoning of the compressive strength of the structural specimens and form-demolding period; and the curing method suggested in this research, which sets the internal conditions of the structural specimens as the conditions of the applied curing method. Then, the thesis suggests the specimen curing method that most closely reenacts the compressive strength of the concrete used on the structural specimens

  • PDF

A Study on the Effect of Blast-Vibration on Curing Lining-Concrete (발파진동이 양생중인 라이닝 콘크리트에 미치는 영향에 관한 연구)

  • 신일재;이정인
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.6
    • /
    • pp.59-68
    • /
    • 2000
  • 현재까지 진동이 양생중인 콘크리트에 미치는 영향을 알아보기 위해 수행된 대부분의 연구에서는 콘크리트 공시체나 콘크리트 블록에 대해 100Hz 미만의 주주파수를 가지는 충격진동이나 진동테이블을 이용한 진동을 가한 후 콘크리트의 강도 변화를 평가하는 방법이 사용되었다. 이 연구에서는 발파진동이 양생중인 라이닝 콘크리트에 미치는 영향을 알아보기 우해 실험실 충격진동 시험과 터널 현장에서의 발파진동 시험을 수행하였다. 터널발파진동과 유사한 100~300Hz의 주주파수를 가지 충격진동을 각각 재령 3, 7, 12 시간에 다한 실험실 시험결과 2cm/sec의 진동속도는 모르타르 라이닝의 P파속도를 증가시키지만, 5 cm/sec, 10cm/sec의진동의 모르타르 라이닝의 P파 속도를 감소시킬 수 있는 것으로 나타났다. 양생기간동안 2.5 cm/sec 이하의 발파진동이 가해진 양생중인 라이닝 콘크리트는 진동을 가하지 않고 양생시킨 콘크리트 공시체에 비해 압축강도가 더 큰 값을 나타내었다. 재령 5시간에 콘크리트 라이닝애 대한 소규모 시험발파로 발파진동을 가한 콘크리트 시료와 진동을 가하지 않고 터널 내에서 양생시킨 공시체에 대해 압축강도를 비교한 결과 콘크리트의 강도 및 탄성파 속도를 저하시킬 수 있는 진동수준은 3~4cm/sec 인 것 으로 나타났다.로 나타났다.

  • PDF

A new steel jacketing method for RC columns and a modified constitutive model of jacketed concrete (RC 기둥 보강을 위한 새로운 강판 보강기법 및 수정 연속체 모델)

  • Tae, Ghi Ho;Choi, Eun Soo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.675-681
    • /
    • 2008
  • This study introduced a new steel-jacketing method to retrofit RC columns. It also estimated the performance of steel-jacketed concrete cylinders. Twelve concrete cylinders were fabricated with varying steel jacket thicknesses of 1.0, 1.5, and 2.0 mm. Lateral confining pressure was applied with three clamps and the performance of plain concrete cylinders was compared with that of steel-jacketed cylinders. Steel jacket proved to be effective in increasing the strength of the cylinder. Finally, Li's constitutive model was compared with that of the experimentalresults. However, Li's model showed incongruity in Region II, which indicates the region after the yield of steel jackets. Therefore, the modified value of n was used for the region and the model showed a good agreement.