• 제목/요약/키워드: 공동 주택

검색결과 2,629건 처리시간 0.031초

하야카와 쿠니히코 초기 공동주택의 공용공간 특성에 관한 연구 - 도쿄 라비린스(ラビリンス)를 중심으로 - (A Study on the Common Space Characteristics of Early Housing by Hayakawa Kunihiko - Focusing on Labyrinth housing in Tokyo -)

  • 기유미;전병권;김경연
    • 대한건축학회논문집:계획계
    • /
    • 제35권1호
    • /
    • pp.55-62
    • /
    • 2019
  • Hayakawa Kunihiko introduced community space as an open space in Housing in Japan for the first time. We can find the continuity of his architectural intent from his three works (Atrium, Steps, Labyrinth) during the early period of his Housing buildings, In particular, from Labyrinth, his intent was expanded to cities through 'Urban Void', seeking communication and harmony. Accordingly, based on the architectural overview and a field survey of Labyrinth, an analysis was conducted using Space Syntax to investigate whether the space of an inner courtyard is being used as a community space for neighbors who pass through the courtyard and whether the courtyard plays the role of 'Urban Void' as intended by the architect. For this investigation, according to VGA, the courtyard showed the role of great visual connectivity and integration and facilitated connections to the center of the entire space. On the other hand, according to J-Graph, the access stairway connected to each household from the courtyard helped secure privacy in the midst of common space. Step Depth noted that a hierarchy of space was formed to ensure visual privacy within each unit household in addition to privacy for each household.

외기 중 미세먼지의 공동주택 실내 유입에 관한 연구 (Analysis of Infiltration of Outdoor Particulate Matter into Apartment Buildings)

  • 방종일;조성민;성민기
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.61-68
    • /
    • 2018
  • Recently, concentration of fine and ultra-fine particulate matter(PM) has been increased in KOREA. The increase of PM in KOREA is due to increase of domestic industries and yellow dust from china. PM is known to cause diseases such as dyspnoea, asthma, arrhythmia. Since PM is harmful to human, KOREA Ministry of Environment(ME) warns people to stay indoors when the outdoor PM concentration is high. However, prior studies has shown that indoor PM concentration can be relatively high when outdoor PM concentration is high due to infiltration of PM into buildings though leakage areas. In this study, airtightness, indoor and outdoor pressure difference and PM 2.5 & 10 concentration were measured in an apartment complex to observe PM infiltrating into building. Field measurement was conducted in newly-built apartment buildings to avoid the influence of indoor PM which can be generated by residents. The airtightness test was conducted to identify the leakage areas of the apartment, such as electric outlets and supply/exhaust diffusers. The airtightness test result showed that the air leakage area of the building was dominant in buildings envelop. According to indoor and outdoor pressure difference measurement result and PM concentration measurement result, it can be concluded that outdoor PM can infiltrate into indoor by leakage areas when wind is blown toward the apartment. As a result, pressure difference formed by the external weather condition and architectural characteristics such as the airtightness in building can influence PM to infiltrate into buildings. In further studies, I/O ratio, stack-effect, infiltration and penetration factor will be considered.

자동 베이크 아웃 시스템을 이용한 휘발성유기화합물 및 포름알데히드 저감효과 (Reduction Effect of VOCs and Formaldehyde Using Auto Bake-Out System)

  • 김형진;이갑수;조진규;이준범;노형래;윤홍수
    • 공업화학
    • /
    • 제22권3호
    • /
    • pp.291-295
    • /
    • 2011
  • 초등학교의 신축된 실내체육관을 대상으로 자동 개폐장치를 이용하여 실내의 휘발성유기화합물 및 포름알데히드 농도 저감효과를 평가하기 위하여 5일간 베이크 아웃을 진행하였다. 베이크 아웃을 실시한 결과 베이크 아웃 실시 전의 농도에 비해 벤젠의 경우 38.2%, 톨루엔은 64.2%, 에틸벤젠은 86.3%, 자일렌은 80.2%, 스티렌은 71.5%의 저감률을 보였으며, 환경부의 신축공동주택의 실내공기질 기준치를 만족하는 것으로 나타났다. 총휘발성유기화합물의 저감률은 67.0%이었으며 포름알데히드의 경우 24.7%의 저감률을 보여 자동 개폐장치를 이용한 베이크 아웃이 실내오염물질을 제거하는 데 유용함을 확인하였으며, 자동 베이크 아웃 시스템을 이용할 경우 효과적인 베이크 아웃이 가능함을 확인하였다.

도심에서의 드론 Last-mile 배송 기술의 정밀 측위 기법 (A Precision Positioning Method of Drone Last-mile Delivery Technology in Urban Areas)

  • 김규석
    • 한국항행학회논문지
    • /
    • 제25권1호
    • /
    • pp.60-67
    • /
    • 2021
  • 미국을 비롯한 전 세계 국가는 드론을 이용한 물류 서비스의 상용화를 위해 활발한 연구를 진행하고 있다. 국내에서도 물류 배송 기업을 비롯하여 이동통신사에서도 드론 물류 배송 서비스의 연구, 개발을 진행 중이다. 그러나 우리나라와 미국은 last-mile 물류 배송 환경이 다르다. 우리나라는 인구의 77% 이상이 아파트 등의 공동주택에 살고 있으며 인구 밀도가 전 세계 4위에 달하는 나라이다. 이에 따라 드론 물류 배송에 있어 우리나라 환경에 맞는 연구가 필요하다. 본 연구에서는 도시 지역에서의 근거리 무선통신과 기압계를 활용한 드론 물류 배송의 정밀 위치 판단의 방법을 제안한다. 실험 결과 제안하는 방법을 통해 2.5m 이내의 창문도 탐지할 수 있음을 확인하였다. 본 연구에서 제안하는 방법을 통해 도심에서의 드론 물류 배송 기술의 향상에 도움이 되길 기대한다.

공동주택 내의 기계환기 설비에 따른 라돈농도 평가 (Evaluation of Radon Concentration according to Mechanical Ventilation Systems in Apartments)

  • 최지원;홍형진;이정섭;유주희;박보람;김가현;윤성원;이철민
    • 한국환경보건학회지
    • /
    • 제47권4호
    • /
    • pp.330-338
    • /
    • 2021
  • Background: This study was conducted to provide background information for the proper management of radon contamination in apartments using mechanical ventilation facilities in residential environments. Objectives: To this end, this study compared and evaluated changes in radon concentrations based on different operating intensities of mechanical ventilation with or without natural ventilation. Methods: For the continuous measurement of radon concentrations, an RAD7 instrument was installed in four apartments equipped with a ventilation system. The measurements were done for comparison of ventilation types and different ventilation intensities ("high", "middle", "low"). Results: The results confirmed that both mechanical and natural ventilation sufficiently reduced the radon concentration in the apartments. In particular, mechanical ventilation at "high" intensity was the most effective. Natural ventilation combined with mechanical ventilation and then natural ventilation alone were the second and the third most effective, respectively. Conclusions: When using ventilation to reduce indoor radon concentrations, it is most effective to operate mechanical ventilation ("high") or natural ventilation and mechanical ventilation at the same time. In cases where mechanical ventilation is available alone, it is recommended to operate it at a minimum of "middle" intensity.

IoT 기반 주택형 건물 에너지 모니터링 시스템 설계 (Design of IoT-based Energy Monitoring System for Residential Building)

  • 이민구;정경권
    • 한국전자통신학회논문지
    • /
    • 제16권6호
    • /
    • pp.1223-1230
    • /
    • 2021
  • 최근 에너지 자원관리는 전 세계적인 주요 관심사이다. 에너지원 생산의 한계 조건 속에서, 효과적인 에너지 관리 활동은 에너지 수요 및 생산을 최소화하고 이는 환경이 미치는 영향을 최소화할 수 있다. 본 논문은 주거형 건물에서 에너지 소비자에게 전기 사용에 대한 실시간 정보를 제공할 수 있는 가정용 전기에너지 모니터링 시스템의 프로토타입 설계를 제안하고자 한다. 제안된 시스템은 자체 개발된 센싱 시스템, 데이터처리시스템, 원격 모니터링 서버 시스템으로 구성된다. 주거형 건물내에 설치 적용된 센싱 시스템은 전원 공급을 제어하는 릴레이, 부하 전기기기의 전류를 감지하는 CT센서, Kmote로 구성된 무선 스마트 플러그로 구성된다. 공동/단독 주거형 건물에서 3개월 동안의 가전제품별 에너지 소비량 데이터를 분석하여 제시하였으며, 실험결과는 에너지 소비 패턴과 현황을 추정할 수 있는 가능성을 확인하여 제시하고 있다.

AIoT와 Mobile기술을 활용한 건설현장 안전관리 활성화 방안에 관한 연구 (A Study on the Promotion of Safety Management at Construction Sites Using AIoT and Mobile Technology)

  • 안형도
    • 한국재난정보학회 논문집
    • /
    • 제18권1호
    • /
    • pp.154-162
    • /
    • 2022
  • 연구목적: 건설현장 안전관리를 인적 역량 중심에서 첨단기술인 AIoT와 Mobile 기술을 활용한 시스템 중심의 관리체계로의 전환을 위한 건설현장 안전관리 활성화 방안을 마련하고자 한다. 연구방법: AIoT와 Mobile 기술을 활용한 건설현장 안전관리 모니터링 시스템이 건설현장의 유효성에 대하여 공동주택현장의 골조공종에 종사하고 있는 작업자를 대상으로 가상휀스, 화재감시, 안전모 미착용 인식 3개의 알고리즘을 적용하여 실험을 실시 하였다. 연구결과: 실험대상 근로자는 215명, 가상휀스 침입은 7.61명으로 불안전 행동 발생율은 실험대상 인원 대비 3.5%, 화재감지는 0.16건으로 실험대상 대비 불안전 행동 발생율이 0.07% 나타났으며, 안전모 미착용 인지는 월 평균 안전모 미착용은 8.79명으로 실험대상 대비 불안전 행동 발생율 4.05% 나타났다. 결론: AIoT와 Mobile 기술을 활용한 건설현장 안전관리 모니터링 시스템이 건설현장에 유효한 영향을 미치는 것으로 나타났다.

건축 프로젝트 특성을 고려한 초기 단계에서의 Off-Site Construction 공법 도입 여부 의사 결정 시스템 개발 - 공동주택 골조공사 중심으로 - (A Study of the Decision Making System in adopting Off-Site Construction Method in the Initial Stage Considering the Building Project Characteristics -Focused on Structure Work of Apartment Housing-)

  • 이성호;차희성;손보식
    • 한국건설관리학회논문집
    • /
    • 제23권1호
    • /
    • pp.89-97
    • /
    • 2022
  • 최근 국내 건설산업에는 생산성 저하, 기능 인력 유입 부족, 품질 저하, 안전사고 증대 우려 등 다양한 문제점들이 나타남에 따라, 이를 해결하기 위한 대안으로 Off-Site Construction (OSC)이 주목을 받고 있다. 그에 따라, 건설 프로젝트의 주체들은 기존의 현장 타설 공법뿐만 아니라, OSC의 도입 또한 하나의 대안으로 고려를 하고 있다. OSC의 도입은 초기 단계에서의 의사결정이 매우 중요함에도 불구하고, 합리적인 의사 결정을 위한 방법론이 부족한 실정이다. 본 연구에서는 프로젝트 특성을 도출하여 그에 대한 공사 난이도 지수를 선정하고 각 공법별 cost model을 개발하여 표준 공사비를 산정하여 최종 공사비 점수를 도출하는 의사 결정 시스템을 개발하였다. 본 연구에서 개발한 의사 결정 시스템을 활용하여 초기 단계에서 OSC 공법의 효율적인 도입을 위한 의사 결정을 할 수 있을 것으로 기대한다.

투입구 기능 개선을 통한 음식물쓰레기종량제 활성화 방안에 관한 연구 (A study on the Activation Methods of Food Volume Meter by improving the Inlet Function)

  • 김용일;김승천
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권3호
    • /
    • pp.75-81
    • /
    • 2022
  • 정부의 배출자 부담 원칙에 따라 배출량에 비례하여 수수료를 차등 부과하는 RFID 기반 음식물류폐기물 종량제가 2012년 전면 시행되었다. 2018년말 기준 전국 149개 지자체, 공동주택 아파트를 기준으로 약 40%의 보급률을 보이고 있다. 장비 도입으로 약 20~30%의 감량 효과가 나타났다. 이와 더불어 기존 장비들에 대한 문제점도 나타나기 시작하였다. 본 연구는 이러한 투입구의 근본적인 문제점의 해결책으로 기존에 나와 있는 기술들을 응용하고 통합하여 개선하고자 하였다. 즉, 음식물쓰레기 종량기 내부의 음식물쓰레기통 안쪽으로 호퍼를 깊숙이 들어가도록 설계를 변경하여 음식물쓰레기가 만수가 되어 수거통 교체 시 원활하도록 고안하여 음식물쓰레기종량기 주변 환경을 개선하고자 한다.

빅데이터 표준분석모델을 활용한 초등돌봄 수요예측 사례연구 (The Case Study for Childcare Service Demand Forecasting Using Bigdata Reference Analysis Model)

  • 윤충식;정승렬
    • 인터넷정보학회논문지
    • /
    • 제23권6호
    • /
    • pp.87-96
    • /
    • 2022
  • 행정이 고도의 전문성과 설득력을 갖추기 위해서는 행정 영역에서 '빅데이터'를 활용하고 이러한 과학적 근거에 기반하여 정책의 수립·집행·평가가 이뤄져야 한다는 관점에서 데이터기반 행정에 대한 시대적 요구가 높아지고 있다. 본 연구는 신규 공동주택단지의 초등돌봄 수요예측을 위해 지역의 특성을 기계학습 기반으로 분석·예측하였다. 이를 위해 전용면적, 세대당 주차대수, 건폐율 등 아파트의 구조와 관련된 데이터, 초등학교까지의 거리 등 아파트 주변의 환경 데이터 및 행정구역의 인구 데이터 등 총 292종의 변수가 활용되었다. 다양한 변수의 활용에 큰 의의가 있으며 복합적인 분석에도 의미가 있다. 또한 실제 기초 지방자치단체의 실제값과 비교를 통해서 모델의 신뢰성을 높인 실증기반 사례연구이다.