• Title/Summary/Keyword: 공기포집

Search Result 144, Processing Time 0.036 seconds

Isolation and Characterization of Airborne Bacteria and Fungi in Indoor Environment of Elementary Schools (초등학교 실내환경에서 공기 중 세균과 진균의 분리 및 특성)

  • Kim, Na-Yeong;Kim, Young-Ran;Kim, Min-Kyu;Cho, Du-Wan;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.43 no.3
    • /
    • pp.193-200
    • /
    • 2007
  • Indoor airborne bacterial and fungal concentrations were examined at classrooms and corridors of 3 elementary schools in Ulsan. Airborne microorganisms were collected with an impaction-type air sampler using plate count agar and dichloran rose bengal chloramphenicol agar. During the semester, concentrations of bacteria ranged $168{\sim}3,887 MPN/m^3$ at classrooms and $168{\sim}6,339 MPN/m^3$ at corridors, while those of fungi ranged $34{\sim}389 MPN/m^3$ at classrooms and $91{\sim}507 MPN/m^3$ at corridors. The bacterial concentrations showed larger variations between situations and schools compared to those of fungi. When airborne bacteria were isolated and identified, 84% were observed as Gram-positive, and Micrococcus spp. was the most abundant group with 61% of tested isolates, followed by genus Staphylococcus with 10%. The Micrococcus spp. isolates, of which 75% were identified as M. luteus, appeared to be from human origins. The protective pigments and substantial cell wall of Micrococcus may provide selective advantage for their survival in the air. We also isolated and identified 15 genera of filamentous fungi. The most common culturable fungi were Cladosporium, Aspergillus and Penicillium, and these 3 genera were 69% of fungal isolates. Genus Stachybotrys, of which S. chartarum is a well known producer of many potent mycotoxins, was also detected from one of the schools. further systematic studies are necessary with an emphasis on species identification and mycotoxin production of isolated fungal genera, including Aspergillus, Penicillium, and Stachybotrys.

Discharge model of gliding arc plasma for benzene decomposition process (벤젠 분해처리를 위한 글라이딩 아크 플라즈마의 방전 모델)

  • Ko, K.;Kim, C.J.;Shin, P.K.;Hwang, M.H.;Kim, J.S.;Nam, K.Y.;Lee, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1383-1384
    • /
    • 2007
  • 직류 고전압을 사용한 글라이딩 아크 플라즈마 반응기에서 휘발성 유기 화합물(Volatile Organic Compounds, VOCs)의 일종인 기상의 벤젠 분해 연구가 진행되었다. 실험에는 압축공기와 벤젠(500ppm)으로 이루어진 혼합가스와 그 농도를 조절하기위한 압축공기가 사용되었다. 기본 방전 특성을 오실로스코프를 이용하여 분석하였다. 벤젠가스의 분해율은 글라이딩 아크 플라즈마와의 반응 전후의 가스를 포집하여 GC(Gas Chromatography)를 통해 정량 분석하여 비교하였다.

  • PDF

Simple Analytical Method for Acrylamide in the Workplace Air Adsorbed by Charcoal Tube (활성탄관을 사용하여 포집한 작업환경 공기중 아크릴아마이드의 분석법)

  • Yang, J.S.;Lee, M.Y.;Park, I.J.;Kang, S.K.
    • Analytical Science and Technology
    • /
    • v.11 no.2
    • /
    • pp.139-144
    • /
    • 1998
  • For the ambient monitoring of acrylamide, the adequate condition of sampling and analysis was checked. The adequate adsorbents and desorption solvents were tested. The combination of charcoal tube as a adsorbent and acetone as a desorption solvent showed 87% desorption efficiency. Flame ionization detector was used to detect acrylamide. The detection limit was 0.814 mg acrylamide in 1 L acetone. It is the equivalent concentration of 0.0203 mg acrylamide in $1m^3$ air if the volume of air collected was 40L. The permissible exposure level (PEL) of acrylamide in the workplace air recommended by Occupational Safety and Health Administration (OSHA, USA) is 0.3 mg acrylamide in $1m^3$ air. So, it is very simple and economic analytical method for acrylamide to be set in the industrial hygiene laboratories.

  • PDF

A Study on the Interaction Effect Between Spray Fan Formed by Gas/Liquid Swirl Injector (기체/액체를 사용하는 Swirl 인젝터의 간섭효과에 관한 연구)

  • Joung, Rae-Hyuck;Kim, Yoo;Cha, Young-Ran;Park, Joung-Bae;Park, Uoo-Dong
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 1997
  • Experimental study was carried out to investigate the interaction effect between spray fan formed by gas/liquid swirl injector. Test variables were supply pressure and injector distance. Water and air were the simulant for the experiment. For water supply only; Collected water mass was concentrated at the lower part of the two spray fan, but this effect was reduced with increasing supply pressure. Both air and water supply1; Collected water mass was again concentrated at the lower part of the impingement point, but this effect was reduced when air/water supply pressure ratio was increased.

  • PDF

Influence of Oxygen Supply Method on the Performance of IGCC Plants (IGCC 플랜트에서 산소공급방식이 성능에 미치는 영향)

  • Ahn, Ji-Ho;Kim, Tong-Seop
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.3
    • /
    • pp.264-273
    • /
    • 2012
  • In this paper, two types of integrated gasification combined cycle (IGCC) plants using either an air separation unit (ASU) or an ion transport membrane (ITM), which provide the oxygen required in the gasification process, were simulated and their thermodynamic performance was compared. Also, the influence of adopting a pre-combustion $CO_2$ capture in the downstream of the gasification process on the performance of the two systems was examined. The system using the ITM exhibits greater net power output than the system using the ASU. However, its net plant efficiency is slightly lower because of the additional fuel consumption required to operate the ITM at an appropriate operating temperature. This efficiency comparison is based on the assumption of a moderately high purity (95%) of the oxygen generated from the ASU. However, if the oxygen purity of the ASU is to be comparable to that of the ITM, which is over 99%, the ASU based IGCC system would exhibit a lower net efficiency than the ITM based system.

Numerical Investigation of Collection Efficiency of Virtual Impactor with Electro-Aerodynamic Lens (전기-공기역학적 렌즈를 이용한 가상임팩터 포집효율에 관한 수치적 연구)

  • Zahir, Muhammad Zeeshan;Yook, Se-Jin
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.7
    • /
    • pp.63-70
    • /
    • 2019
  • An electro-aerodynamic lens for improving the performance of virtual impactor has been proposed in this study. ANSYS FLUENT Release 16.1 was used for numerical analysis of virtual impactor with and without the electro-aerodynamic lens, used to collimate the incoming aerosol particles into a particle beam before injecting the particles into the virtual impactor. Particles supplied to the electro-aerodynamic lens were assumed to be highly charged. By using an aerodynamic lens before the virtual impactor, without any electrostatic effect, it was found that the cut-off diameter of the virtual impactor was reduced from $4.2{\mu}m$ to $0.68{\mu}m$ and that the fine particle contamination problem became more serious. However, by employing the combined electrostatic and aerodynamic effects, that is, by applying electric voltage potential to the electro-aerodynamic lens, the cut-off diameter was found to be further reduced to $0.45{\mu}m$ and the fine particle contamination was eliminated.

Sampling efficiencies of the activated carbon fiber and 3M diffusive samplers for organic vapors (공기중 유기용제 측정을 위한 활성탄섬유 확산포집기와 3M 확산포집기의 시료포집효율에 대한 연구)

  • Byeon, Sang-Hoon;Oh, Se-Min;Lee, Chang-Ha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.7 no.1
    • /
    • pp.21-31
    • /
    • 1997
  • Toluene, n-hexane, and methyl ethyl ketone(MEK) were exposed to the activated carbon fiber(ACF) and 3M(Model 3500) diffusive samplers under low and high humidity levels. In order to evaluate these two samplers, the sampling capacity, sampling rate, reverse diffusion, and storage stability were obtained. At low humidity level($8{\pm}3%RH$), the adsorption amount of all three organic vapors to the ACF diffusive sampler showed a positive linear relationship up to 8 hours. However, at high humidity level($90{\pm}5%RH$), n-hexane and MEK maintained a positive linear relationship up to 1.5 hrs, but decreased in their adsorption amounts afterwards. On the other hand, the adsorption amount of n-hexane, MEK, and toluene to 3M diffusive sampler showed almost a positive linear relationship up to 8 hours at both humidity levels. At low humidity level, there was almost no reverse diffusion for both 3M and ACF diffusive samplers. However, when the ACF diffusive sampler was used at high humidity level, there was about 52.63% of MEK sample loss and about 92.59% of n-hexane sample loss. The storage stabilities of the ACF and 3M diffusive samplers were both relative stable except for MEK. In the case of MEK, the difference between the analysis of the organic vapor right after the sampling and that of 3 weeks later at room temperature was 45% for the ACF diffusive sampler and 18% for the 3M diffusive sampler. Since the storage stability of the samples stored in a refrigerator was relatively stable, they need to be refrigerated until the analysis is done.

  • PDF

A Comparison of Nicotine Diffusive Sampler and XAD-4 Tube for Determination of Nicotine in ETS (공기 중 니코틴 포집에 있어 국산 확산포집기와 능동포집기의 비교 평가)

  • Kim, Hyo-Cher;Paik, Nam-Won;Lee, Kyung-Suk;Kim, Kyung-Ran;Kim, Won
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.485-491
    • /
    • 2006
  • It is widely known that Environmental Tobacco Smoke(ETS) is not good for health. ETS is composed of a lot of chemicals. So indicators are needed to evaluate the risk of ETS in air. One of the indicators is Nicotine. Active sampler has been used to measure nicotine concentration in air. The experiments were conducted to compare the active sampler method with diffusive sampler in exposure chamber and smoking areas, respectively. Sampling rate was 40.5 ml/min in exposure chamber. Experimental sampling rate (40.5 ml/min) was more than theoretical sampling rate (33.52 ml/min). And the higher was the concentration in air, the higher was experimental sampling rate. The average desorption, rate was 113.6%. The overall precision was 7.31 %. The overall accuracy was 18.96%, which were under NIOSH criteria. The average(GM) concentrations of nicotine by two sampling methods were $8.29{\mu}g/m^{3}$ (active sampler), $7.54{\mu}/m^{3}$ (diffusive sampler) in smoking area and smoking room. There was no regression between active sampler and diffusive sampler ($R^{2}=0.2397$). But slope, coefficient of determination was 1.017, 0.9292, respectively after removing outliers. And the slope (1.017) was close to the theoretical slope (1). In conclusion, this study indicated that diffusive sampler can be used to evaluate concentration of nicotine in air instead of active sampler.

Analysis on Antifungal Activity of Paulownia-Wood Storage Box and Application of Natural Biocide for the Activity Enhancement (오동나무상자의 항균활성 분석 및 활성 증진을 위한 천연 살생물제 적용연구)

  • Chung, Yong-Jae;Kang, So-Yeong;Choi, Yun-A
    • Journal of Conservation Science
    • /
    • v.24
    • /
    • pp.75-83
    • /
    • 2008
  • In order to assess antifungal activity of a wooden storage box, which was made of Paulownia tomentosa and used for keeping ancient documents, antifungal activity of volatile organic compounds emitted from the box was investigated along with qualitative analysis on major substances of the compounds. After collecting floating microorganisms inside air tester, the fungal activity was assessed by counting the number of colonies growing on TSA media. Compared to the control which collected 85 colonies from outdoor, 72 colonies were observed showing reduction rate of 14.82%. Through GC/MS and TDS system analysis, limonene was detected from the volatile organic compounds as characteristic features. When the fungal activity was assessed through fumigation by adding natural biocide BI and BII containing eugenol and anethole as major substances, both biocides showed a strong fungal activity with respectively 92.6%(inside the box) and 99.9%(outdoor) of reduction rate. Although these results didn't clarify antifungal activity of the volatile organic compounds emitted from the Paulownia-wood storage box and their functional components, it was at least confirmed that there is application possibility of natural biocide to use for preservation of ancient documents with increased efficiency in controlling pests of wooden storage boxes.

  • PDF

Analysis of didecydimethylammonium chloride (DDAC) aerosol in inhalation chamber (흡입챔버 내 didecyldimethylammonium chloride(DDAC) 에어로졸의 분석)

  • Yang, Jeong-Sun;Choi, Sung-Bong;Park, Sang-Yong;Lee, Sung-Bae
    • Analytical Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.307-312
    • /
    • 2012
  • To perform inhalation toxicity test by using experiment animals, we set up an analytical method to monitor didecyldimethylammonium chloride (DDAC) in aerosol nebulized into inhalation chambers by ion chromatography. DDAC was adsorbed by XAD-2 resin and analyzed with conductivity detector. Recovery of DDAC desorbed by acetonitrile from XAD adsorbent was 87.8%. The method detection limit (MDL) and the limit of quantitation (LOQ) were 2.97 ${\mu}g/m^3$ and 8.92 ${\mu}g/m^3$, respectively. Repeatability was calculated as RSD 7.8% in the range of 0~20 ${\mu}g/mL$. Time needed to analyze a sample was less than 5 minutes. Therefore, the analysis of DDAC by ion chromatography was practically useful in monitoring DDAC in inhalation chambers with rapidity and sensitivity manner to perform inhalation toxicity test using experimental animals.