Abstract

It is widely known that Environmental Tobacco Smoke(ETS) is not good for health. ETS is composed of a lot of chemicals. So indicators are needed to evaluate the risk of ETS in air. One of the indicators is Nicotine. Active sampler has been used to measure nicotine concentration in air. The experiments were conducted to compare the active sampler method with diffusive sampler in exposure chamber and smoking areas, respectively. Sampling rate was 40.5 ml/min in exposure chamber. Experimental sampling rate (40.5 ml/min) was more than theoretical sampling rate (33.52 ml/min). And the higher was the concentration in air, the higher was experimental sampling rate. The average desorption, rate was 113.6%. The overall precision was 7.31 %. The overall accuracy was 18.96%, which were under NIOSH criteria. The average(GM) concentrations of nicotine by two sampling methods were $8.29{\mu}g/m^{3}$ (active sampler), $7.54{\mu}/m^{3}$ (diffusive sampler) in smoking area and smoking room. There was no regression between active sampler and diffusive sampler ($R^{2}=0.2397$). But slope, coefficient of determination was 1.017, 0.9292, respectively after removing outliers. And the slope (1.017) was close to the theoretical slope (1). In conclusion, this study indicated that diffusive sampler can be used to evaluate concentration of nicotine in air instead of active sampler.

Keywords

References

  1. National Academy of Sciences, National Academy of Sciences Report : Environmental Tobacco Smoke, Measuring Exposure and Assessing Health Effect : GPO : Washington, DC, 1986
  2. U.S Department of Health and Human Services, The Health Consequences of Involuntary Smoking : A Report of the Surgeon General, U.S. Government Printing Office, Washington, DC, 1986
  3. 황규석, 백남원, 하권철 : 서울시내 PC방에서의 환경성담배연기(ETS) 농도에 관한 연구. 한국환경위생학회지 29(3), 46-47, 2003
  4. 고영림, 양원호, 정문호 : 서울시 일부 음식점 종업원의 간접흡연 노출량 측정. 한국환경위생학회지 28(2), 179-180, 2002
  5. 하권철 : 실내사무환경에서의 환경성담배연기(ETS) 중일부 휘발성유기화합물(VOC)에 관한 연구. 한국 환경위생학회지 27(3), 95-97, 2001
  6. National Institute for Occupational Safety and Health (NIOSH) : NIOSH Manual of Analytical Method, 4th ed., 1994
  7. Michael W. Ogden, Katherine C. Malolo : Comparative evaluation of diffusive and active sampling system for determining airborne nicotine and 3-ethenylpyridine. Environmental Science and Technology, 26(6), 1226-1234, 1992 https://doi.org/10.1021/es50002a612
  8. S. Katharine Hammond, Brian P. Leaderer : A diffusion monitor to measure exposure to passive smoking. Environmental Science and Technology, 21(5), 494-497, 1987 https://doi.org/10.1021/es00159a012
  9. David G. Taylor, Richard E. Kupel, and John M. Bryant : Documentation of the NIOSH Validation Tests. DHHS(NIOSH) : 1-12, 1997
  10. 하권철 : 실내환경의 환경성담배연기(ETS)중 일부 발암물질 노출지표에 관한 연구. 서울대학교 보건대학원 박사논문, 1996
  11. American Conference of Governmental Industrial Hygienists(ACGIH) : Threshhold Limit Value for Chemical substances and physical agents and biological exposure indices, 2001
  12. 산업안전공단 산업안전보건연구원 : 저농도 광역화 오염물질 포집형 확신식 채취기의 개발에 관한 연구, 2000