• Title/Summary/Keyword: 공기와 공사비

Search Result 231, Processing Time 0.025 seconds

Analyzing the Efficiency of Korean Rail Transit Properties using Data Envelopment Analysis (자료포락분석기법을 이용한 도시철도 운영기관의 효율성 분석)

  • 김민정;김성수
    • Journal of Korean Society of Transportation
    • /
    • v.21 no.4
    • /
    • pp.113-132
    • /
    • 2003
  • Using nonradial data envelopment analysis(DEA) under assumptions of strong disposability and variable returns scale, this paper annually estimates productive. technical and allocative efficiencies of three publicly-owned rail transit properties which are different in terms of organizational type: Seoul Subway Corporation(SSC, local public corporation), the Seoul Metropolitan Electrified Railways sector (SMESRS) of Korea National Railroad(the national railway operator controlled by the Ministry of Construction and Transportation(MOCT)), and Busan Urban Transit Authority (BUTA, the national authority controlled by MOCT). Using the estimation results of Tobit regression analysis. the paper next computes their true productive, true technical and true allocative efficiencies, which reflect only the impacts of internal factors such as production activity by removing the impacts of external factors such as an organizational type and a track utilization rate. And the paper also computes an organizational efficiency and annually gross efficiencies for each property. The paper then conceptualized that the property produces a single output(car-kilometers) using four inputs(labor, electricity, car & maintenance and track) and uses unbalanced panel data consisted of annual observations on SSC, SMESRS and BUTA. The results obtained from DEA show that, on an average, SSC is the most efficient property on the productive and allocative sides, while SMESRS is the most technically-efficient one. On the other hand. BUTA is the most efficient one on the truly-productive and allocative sides, while SMESRS on the truly-technical side. Another important result is that the differences in true efficiency estimates among the three properties are considerably smaller than those in efficiency estimates. Besides. the most cost-efficient organizational type appears to be a local public corporation represented by SSC, which is also the most grossly-efficient property. These results suggest that a measure to sort out the impacts of external factors on the efficiency of rail transit properties is required to assess fairly it, and that a measure to restructure (establish) an existing(a new) rail transit property into a local public corporation(or authority) is required to improve its cost efficiency.

Formalization of Productivity Metrics for Equipment in Multi-sectioned Road Construction Projects (다(多)공구 도로 공사 현장 장비들의 운영 실태 파악을 위한 생산성 지표 정립에 관한 연구)

  • Kim, Hong-Yeul;Koo, Bon-Sang
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.4
    • /
    • pp.100-109
    • /
    • 2012
  • Large road construction projects are typically partitioned into sections that are then contracted individually to contractors. Each section requires using similar heavy equipment including excavators, dump trucks and pavers, which constitute the highest cost. Normally the equipment is not shared between them, as each contractor wishes to have their equipment readily available. However, such practices result in very low utilization of these equipment. The goal of this research is to develop a programmatic resource sharing system in which contractors can share equipment depending on the changing needs of a multi-sectioned road project. This paper introduces the results of a survey performed to investigate how contractors currently manage the supply and demand of equipment and the equipment that are practical for sharing across a project. More importantly, the paper describes a set of metrics (DPR, nDPR, SDI) needed to quantify the amount of supply/demand variance occurring in each section. The metrics were used on an actual road construction project, and the results show that each section suffers from an imbalance between its monthly planned and actual utilization of equipment. The results also indicate that the sharing of the equipment can lead to potentially large savings as equipment requirements can be met within a project as to short leasing from outside vendors.

The PC concrete Rainwater Storage Facility development for a prevention of disaster and a water resources re-application (방재 및 수자원 재활용을 위한 PC콘크리트 빗물저류조의 개발)

  • Chang, Young-Cheol;Cho, Cheong-Hwi;Kim, Ok-Soo;Oh, Se-Eun;Lee, Jun-Gu
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.879-883
    • /
    • 2005
  • 우리나라는 하천유역의 도시화 추세 속에 불투수층의 증가로 빗물의 일시 유출로 인한 홍수발생으로 많은 인명과 재산피해가 발생하고 있어 방재적 차원에서의 수자원관리가 시급한 실정이다. 또한, 초기 빗물과 합류식 하수도의 월류수에 의한 하천, 호소, 및 습지의 수질오염문제도 많이 발생하고 있다. 이러한 문제를 해결하기 위하여 콘크리트로 제작된 PC 지하식 빗물저류시설로서 상부의 공간은 공원, 운동장, 주차장 등 다양하게 이용하면서 방재와 치수를 가능케 할 수 있다. 또한, PC 콘크리트 빗물저류조는 현장 타설이 아닌 PC콘크리트 블록을 현장에서 조립하여 시공기간이 대폭적으로 단축되고, 작업환경 및 주변환경을 개선시킬 수 있다. 또한, 지하수의 보전, 회복을 위한 빗물저류 침투 시설 역할도 수행하여 비상용수를 확보하고 여름철 홍수 시 빗물을 가두어 재해를 방지하는 등의 다목적 시설로 활용된다. 지하 매립형 빗물저류조는 기존의 암거설계기준을 참조하여 일본의 내진설계 기준을 반영하였으며, 고강도 콘크리트를 사용하여 강도 또한 뛰어나다. 그리고 시공이 간편하고 공기의 단축에 탁월한 효과를 나타내며, 빗물저류조 설치는 다음과 같은 특징이 있다. 1. 지하저류형 빗물저류조 시설로 설계되어 토지의 효과적인 이용이 기대된다. 2. 공사기간이 짧아 경제적이다. 3. 안정된 구조체이다. 4. 부지의 형태에 맞춘 시공이 가능하다. 5. 소규모에서 대규모의 유수지까지 광범위하게 대응이 가능하다. 6. 방재역할 수행 및 빗물이용의 역할을 담당할 수 있다. 7. 불투수층이 증가하고 있는 도시지역에서 적극 활용가능하다.로 판단된다.한 예비방류의 시행과 강우종료 후에도 이수용량에는 손실이 없는 저수지의 관리방안의 지침이 되는데 효율적이라 판단되었다. 방법을 개발하여 개선시킬 필요성이 있다.>$4.3\%$로 가장 근접한 결과를 나타내었으며, 총 유출량에서도 각각 $7.8\%,\;13.2\%$의 오차율을 가지는 것으로 분석되어 타 모형에 비해 실유량과의 차가 가장 적은 것으로 모의되었다. 향후 도시유출을 모의하는 데 가장 근사한 유출량을 산정할 수 있는 근거가 될 것이며, 도시재해 저감대책을 수립하는데 기여할 수 있을 것이라 판단된다.로 판단되는 대안들을 제시하는 예비타당성(Prefeasibility) 계획을 수립하였다. 이렇게 제시된 계획은 향후 과학적인 분석(세부평가방법)을 통해 대안을 평가하고 구체적인 타당성(feasibility) 계획을 수립하는데 토대가 될 것이다.{0.11R(mm)}(r^2=0.69)$로 나타났다. 이는 토양의 투수특성에 따라 강우량 증가에 비례하여 점증하는 침투수와 구분되는 현상이었다. 경사와 토양이 같은 조건에서 나지의 경우 역시 $Ro_{B10}(mm)=20.3e^{0.08R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며

  • PDF

Applying CVM for the Reinvestment Ratio of Development Profits Generated by Renewing Old Industrial Park in Daegu Metropolitan City (CVM 분석을 이용한 개발이익 재투자 비율 설정에 관한 연구: 대구광역시 노후산업단지 재생사업을 중심으로)

  • Shin, Woo-Hwa;Shin, Woo-Jin
    • Land and Housing Review
    • /
    • v.13 no.4
    • /
    • pp.27-44
    • /
    • 2022
  • In December 2019, the Ministry of Land, Infrastructure and Transport announced the revision of the Enforcement Decree of the Industrial sites and Development Act. In this revision, the reinvestment ratio of development profits generated by renewing the old industrial park is delegated to the local government ordinance. According to this announcement, the reinvestment ratio can be adjusted to less than 50% of sales revenue from construction projects and 25% of land sales for non-industrial use depending on local government conditions. This study aims to investigate the policy rationale for the adjusted ratio of reinvestment in development profits and explore how Daegu City can use this policy when revising ordinances in the future. A survey was conducted with a total of 320 experts, including public corporations, public officials, and industrial site workers in the Industrial Complex Committee. We employ contingent value measurement (CVM) based on 262 valid responses. The results showed that 27% of sales from the construction business and 22% of sales from non-industrial land were derived with an appropriate reinvestment ratio. Although the results in this study might not be generalized in other regions, we provide a potential reference for other local governments who are interested in ordinance revisions in the future. Another contribution of this study is to suggest the statistical method to derive the relevant ratio.

Experimental Study on Field Applicability of Tightened Coupler with Two-Way Threading (양방향 나사산 체결방식을 활용한 완전밀착형 커플러의 시공성 분석)

  • Park, U-Yeol;Hong, Seong-Wook;Yang, Jin-Kook;Ko, Suck-Hwa;An, Sung-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.1
    • /
    • pp.87-93
    • /
    • 2014
  • A tightened coupler with two way-threading is suggested to overcome the previous one-way threaded coupler. The experiment and a mock-up test were conducted to analyze the constructability of the suggested coupler. The aim of the mock-up test was to assemble the suggested coupler in horizontal rebar of mat footing and vertical rebar of semi-fabricated column bars. The method using the suggested coupler in semi-fabricated column bars is developed by analyzing the problem of fabricated column bars using the one-way threaded coupler. The result of the mock-up test showed that the time required to assemble the suggested coupler in the horizontal bars is shorter than it is for the one-way threaded coupler. In addition, the method using the suggested coupler in semi-fabricated column bars has advantages such as lower working loads, supporting safe work and strongly tightening the rebar. From these results, it is revealed that the suggested coupler is adequate to use in rebar work in terms of cost, quality and time.

Research on the Architectural Applications of High-Performance Vacuum Insulation Panel (고성능 진공단열재의 건축적인 적용에 관한 연구)

  • Kwon, Young Cheol;Kim, Suk
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.23-32
    • /
    • 2019
  • Vacuum Insulation Panel(VIP) has the lowest thermal conductivity among present insulations. It is composed of envelope, core material and getter. Aluminum film is usually used as the envelope of VIP, and it is important component to decide the useful life of VIP. In this research, the thermophysical properties of incombustible fiber glass core VIP were investigated with the possibility of its architectural applications. The results of this research can be summarized as follows: 1) The thermal conductivity of 20mm-thick fiber glass core VIP is resulted as 0.00177W/m·K, which means that 20mm-thick VIP can meet all the reinforced insulation guideline and it can be used in any envelope of any region in Korea. 2) As a result of the test of incombustion and gas toxicity, fiber glass core VIP was suitable for incombustible material. 3) As the test result for the long term thermal conductivity, fiber glass core VIP was found out that it would keep above 10 times insulating performance than polystyrene foam and glass fiber. 4) To meet the thermal transmittance of 0.12W/㎡K, limited-combustible insulation of expanded polystyrene foam and phenolic foam should be used respectively as thick as above 280mm and 170mm, incombustible VIP can meet the same insulation level with 20mm thickness. 5) The price competitiveness of incombustible VIP to meet the thermal transmittance of 0.12W/㎡·K was about 1,500won/㎡ higher than that of phenolic foam.

A study on the Effect of Calcium Chloride Admixture on strengths of Concrete (혼화제인 염화칼슘이 콘크리트 강도에 미치는 영향에 관한 연구)

  • Jun, Hyun-Woo;Lim, Chong-Kook
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.13 no.4
    • /
    • pp.2419-2425
    • /
    • 1971
  • In many cold weather concrete constructison jobs calcium chloride $CaCl_2$ can be used safely as an accelerating admixture. For producing satisfactory concrete during cold weather calcium chloride is used to develop the level of strength required in a shorter period by obtaining higher early strength, the resulting in crease in heat of hydration. In this paper, to get adequated data and information of the effect on strength of concrete in using calcium chloride as an accelerating admixture, Portland cement (Type I), High-early-strength cement(Type II) and Pozzolans cement with certain 1.5 percentage of calcium chloride by weight of the cement were tested. As the result of this experiment, followings were founded: 1. At the 1.5 percent of calcium chloride cement ratio, the early strength was accelerated to the highest level, and some 1.5 percent of calcium chloride cement ratio was suitable for the stabilization of the concrete structures. 2. For Some 50 percent of Water Cement ratio was suitable, making good Concrete in the Cold weather by admixture of Calicum Chloide. 3. The concrete of Pozzorans cement in early strength was weak but that in later rised by degree. 4. As abtaining higher early strength the curing period can be reduced, but the finishing work should be done as early as possible.

  • PDF

An Experimental and Numerical Study on the Stemming Effect of a Polymer Gel in Explosive Blasting (화약발파에서 폴리머 겔의 전색효과에 관한 실험적 및 수치해석적 연구)

  • Baluch, Khaqan;Kim, Jung-Gyu;Ko, Young-Hun;Kim, Seung-Jun;Jung, Seung-Won;Yang, Hyung-Sik;Kim, Youg-Kye;Kim, Jong-Gwan
    • Explosives and Blasting
    • /
    • v.36 no.4
    • /
    • pp.35-47
    • /
    • 2018
  • In this study, several concrete-block blast tests and AUTODYN numerical analyses were conducted to analyze the effects of different stemming and coupling materials on explosion results. Air, sand, and polymer gel were used as both the stemming and coupling materials. The stemming and coupling effects of these materials were compared with those of the full-charge condition. Soil-covered or buried concrete blocks were used for field crater tests. It was found from the concrete block tests and numerical analyses that both the crater size and the peak pressure around the blast hole were higher when the polymer gel was used than when the sand and the decoupling condition were used. The numerical analyses revealed the same trend as those of the field tests. Pressure peaks in concrete block models were calculated to be 37, 30, and 16 MPa, respectively, for the cases of the polymer gel, sand, and no stemming and decoupling condition. The pressure peak was 52 MPa in the case of full-charge condition, which was the highest pressure. But the damage area for the case was smaller than that obtained from the use of polymer gel. Full-charge was also used as a reference test.

Establishment of Risk Database and Development of Risk Classification System for NATM Tunnel (NATM 터널 공정리스크 데이터베이스 구축 및 리스크 분류체계 개발)

  • Kim, Hyunbee;Karunarathne, Batagalle Vinuri;Kim, ByungSoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.25 no.1
    • /
    • pp.32-41
    • /
    • 2024
  • In the construction industry, not only safety accidents, but also various complex risks such as construction delays, cost increases, and environmental pollution occur, and management technologies are needed to solve them. Among them, process risk management, which directly affects the project, lacks related information compared to its importance. This study tried to develop a MATM tunnel process risk classification system to solve the difficulty of risk information retrieval due to the use of different classification systems for each project. Risk collection used existing literature review and experience mining techniques, and DB construction utilized the concept of natural language processing. For the structure of the classification system, the existing WBS structure was adopted in consideration of compatibility of data, and an RBS linked to the work species of the WBS was established. As a result of the research, a risk classification system was completed that easily identifies risks by work type and intuitively reveals risk characteristics and risk factors linked to risks. As a result of verifying the usability of the established classification system, it was found that the classification system was effective as risks and risk factors for each work type were easily identified by user input of keywords. Through this study, it is expected to contribute to preventing an increase in cost and construction period by identifying risks according to work types in advance when planning and designing NATM tunnels and establishing countermeasures suitable for those factors.

An Evaluation of Allowable Bearing Capacity of Weathered Rock by Large-Scale Plate-Bearing Test and Numerical Analysis (대형평판재하시험 및 수치해석에 의한 풍화암 허용지지력 평가)

  • Hong, Seung-Hyeun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.10
    • /
    • pp.61-74
    • /
    • 2022
  • Considering that the number of cases in which a structure foundation is located on weathered rock has been increasing recently, for adequate design bearing capacity of a foundation on weathered rock, allowable bearing capacities of such foundations in geotechnical investigation reports were studied. With reference to the study results, the allowable bearing capacity of a foundation on weathered rock was approximately 400-700 kN/m2, with a large variation, and was considered a conservative value. Because the allowable bearing capacity of the foundation ground is an important index in determining the foundation type in the early design stage, it can have a significant influence on the construction cost and period according to the initial decision. Thus, in this study, six large-scale plate-bearing tests were conducted on weathered rock, and the bearing capacity and settlement characteristics were analyzed. According to the test results, the bearing capacities from the six tests exceeded 1,500 kN/m2, and it shows that the results are similar with the one of bearing capacity formula by Pressuremeter tests when compared with the various bearing capacity formula. In addition, the elastic modulus determined by the inverse calculation of the load-settlement behavior from the large-scale plate-bearing tests was appropriate for applying the elastic modulus of the Pressuremeter tests. With consideration of the large-scale plate-bearing tests in this study and other results of plate-bearing tests on weathered rock in Korea, the allowable bearing capacity of weathered rock is evaluated to be over 1,000 kN/m2. However, because the settlement of the foundation increases as the foundation size increases, the allowable bearing capacity should be restrained by the allowable settlement criteria of an upper structure. Therefore, in this study, the anticipated foundation settlements along the foundation size and the thickness of weathered rocks have been evaluated by numerical analysis, and the foundation size and ground conditions, with an allowable bearing capacity of over 1,000 kN/m2, have been proposed as a table. These findings are considered useful in determining the foundation type in the early foundation design.