• Title/Summary/Keyword: 공기구

Search Result 702, Processing Time 0.032 seconds

A Study on the Optimum Design of Air-Conditioning Duct with Multiple Diffusers (다수의 취출구를 갖는 A/C덕트의 최적설계에 관한 연구)

  • 김민호;이대훈
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.98-106
    • /
    • 2002
  • The airflow characteristics of an air-conditioning duct with multiple diffusers were investigated through one-dimensional analysis, CFD simulation and experimental measurement. One-dimensional program based on Bernoulli's equation and minor loss equations was developed in order to evaluate the air distribution rate at each diffuser. In CFD simulation, three-dimensional flow characteristics inside air-conditioning duct were computed for incompressible viscous flow, adopting the RNG k-$\xi$turbulence model. Also, in an effort to equalize the discharge flow rate at each outlet, the optimization procedure has been performed to obtain the optimum diffuser area. In this process, square of difference between maximum discharge rate and minimum discharge rate is used as an object function. Diffuser area and discharge velocity are established as constraints. After optimization process, determined design variables are applied again in CFD simulation and experiment to validate the optimized result by one-dimensional program. Comparison with the experimental data of airflow rate distribution showed that the developed program seems to be acceptable and can be useful design tool for an automotive air-conditioning duct in an initial design stage.

Cause Diagnosis and Reduction Measures of Foaming in the Treated Wastewater Outlet of D Wastewater Treatment Plant (하수처리수 방류구의 거품발생 원인진단 및 저감방안: 국내 하수처리장 사례를 중심으로)

  • Shin, Jae-Ki;Cho, Youngsoo;Kim, Youngsung;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.2
    • /
    • pp.124-129
    • /
    • 2016
  • This study was conducted to suggest the cause analysis and mitigation measures of foaming generated in the effluent of wastewater treatment plant. The foam generated in the outlet connected with the tidal river system was identified as structural problems. And the main cause of foaming was air entrainment by an impinging jet and the internal accumulation by the diffusion barrier. In consideration of these conditions, it present the effective ways such as micro-screen and submerged outlet, to mitigate the foaming generated in the water channel and outlet end.

Evaluation of Rectangular Section Flutter Derivatives by CFD (CFD에 의한 사각단면의 플러터계수 산출)

  • Min, Won;Lee, Yong Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.6 s.67
    • /
    • pp.693-700
    • /
    • 2003
  • An evaluation method for flutter derivatives is proposed, using indicial functions of structural members produced by Computational Fluid Dynamics (CFD). Flutter derivatives are obtained by Fourier integration of indicial functions. Instead of direct simulation of oscillating objects, only the calculation of time-dependent lift and moment variations of fixed objects with constant attack angle are necessary.The Finite Element Method (FEM) is developed as a tool for the numerical method. For two rectangular sections having different aspect ratios, the numerical analysis and wind tunnel test are carried out to inspect the adequacy of this study. The results proved to be good, and they could be used for a preliminary design.

Effect of Different Packaging Methods on the Quality and Storage Characteristics of Domestic Broiler Breast Meat during Cold Storage (포장 방법의 차이가 냉장 저장 중 국내산 닭가슴육의 품질 및 저장 특성에 미치는 영향)

  • Yang, H.S.;Jeong, J.Y.;Choi, Y.H.;Joo, S.T.;Park, G.B.
    • Korean Journal of Poultry Science
    • /
    • v.36 no.1
    • /
    • pp.69-75
    • /
    • 2009
  • The effects of different packaging methods such as aerobic, vacuum, and wrap packaging, on quality characteristics of fresh chicken breast meat during cold storage were investigated. The results show that crude fat content in aerobic packaging method was significantly (P<0.05) higher compared to the others, whereas moisture, protein and ash contents were not significantly different. pH in wrap packaging was increased with storage time and reached the highest values at 10 days. Both lightness and redness of the meat were increased with storage time, but lightness was significantly (P<0.05) higher in wrap packaging than in the others. Thiobarbituric acid (TBA) and volatile basic nitrogen (VBN) values were increased in all treatments at 10 days. VBN at 5 days were over 20 mg%, and TBA values at 10 days were between 0.82~1.05 mg malondialdehyde/kg meat. TBA showed significantly (P<0.05) lower in vacuum packaging compared to the other methods. Therefore, our results suggested that vacuum packaging decreases lipid oxidation of chicken breast meat, thereby enhancing the shelf life, compared to aerobic and wrap packaging methods.

Effect of Day/Night Temperatures during Seedling Culture on the Growth and Nodes of Early Flower Cluster Set of 'Seokwang' Tomato (Lycopersicum esculentum Mill.) (육묘시의 주야간 기온이 서광 토마토의 생육 및 초기 착화 절위에 미치는 영향)

  • 김오임;정병룡
    • Journal of Bio-Environment Control
    • /
    • v.8 no.2
    • /
    • pp.75-82
    • /
    • 1999
  • This study was carried out to examine the effect of day/nignt temperatures during seedling culture on the vegetative and reproductive growth of Lycopersicum esculentum ‘Seokwang’. The study was consisted of two culture stages, plug seedling production in the growth chamber and hydroponic culture of the plant in a glasshouse. Experiments were replicated over time. The germinated seedlings were raised for 33 days (experiment 1) and 35 days (experiment 2) in 4 growth chambers, each with day/night temperatures of either $25^{\circ}C$/$25^{\circ}C$, 16$^{\circ}C$/16$^{\circ}C$, 16$^{\circ}C$/$25^{\circ}C$ or $25^{\circ}C$/16$^{\circ}C$. Cool-white fluorescent lamps provided 140$\mu$mol.m$^{-2}$ .s$^{-1}$ light for 12h each day. In the second experiment, all chambers were supplied with 1000$\mu$mol.mol$^{-1}$ CO$_{2}$ during the photoperiod and had an air velocity of 0.3m.s$^{-1}$ and relative humidity of 80%. Plug seedlings raised were transplanted to rockwool slabs in a glasshouse and were grown hydroponically using the same nutrient solutions used for seedling culture for 37 days (experiment 1) and 35 days (experiment 2). Plant height was affected more by mean daily temperature than by interaction of day and night temperatures. Plant height was the highest in 16/16$^{\circ}C$ treatment. Leaf count was not affected by day and night temperatures, and the chlorophyll concentration was the highest in 16/$25^{\circ}C$ treatment. Fresh and dry weights of stem tended to be greater in treatments of constant day and night temperature. The number of node on which first and second flower clusters were set was significantly higher in 25/$25^{\circ}C$ treatment than in the other treatments. Days to flower of the first flower on the first flower cluster were the greatest in 25/$25^{\circ}C$ and the least in 16/$25^{\circ}C$ treatment. Vegetative and reproductive growth, such as height, fresh and dry weights, days to flower, and nodes of the 1st and 2nd flower cluster set were affected by day/night temperatures.

  • PDF

Effects of Modified Atmosphere Packaging on the Quality of Chitosan and $CaCl_2$ Coated Mushroom (Agaricus bisporus) (환경가스조절 포장이 키토산 및 $CaCl_2$로 코팅 처리된 양송이 버섯의 품질에 미치는 영향)

  • Lee, Jin-Sil
    • Korean Journal of Food Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.1308-1314
    • /
    • 1999
  • The effects of modified atmosphere(MA) packaging and coating on the quality of mushroom (Agaricus bisporus) were investigated. Whole mushrooms(100 g) were packed with polyvinyl chloride(PVC) film wrap, PD941 and PD961 film bags and were stored in a chamber at $12^{\circ}C$ and 80% RH for 6 days. Gas composition of packages, respiration rate, weight loss, color and maturity index of MA packaged mushrooms were examined. The wrap packaged mushrooms showed different level of internal $CO_2$ concentrations among water washed, chitosan coated and $CaCl_2$ coated subgroups significantly at 5% level. The maximum $CO_2$ concentration of PD941 and PD961 packages for all coated showed $4.1{\sim}4.7%$ and $10.4{\sim}11.7%$, respectively, for the first day. PD961 package showed the lowest $O_2$ concentration compared to other groups. There were no significant respiration rate differences between wrap packed and PD941 packaged. Respiration rate of water washed. chitosan coated and $CaCl_2$ coated in PD961 packaged was 192 mg, 226 mg and 245 mg, respectively. Maturity index of PD961 packaged were not significantly different among the water washed, chitosan and $CaCl_2$ coated packages. Chitosan coating showed a negative effect on color change of mushrooms. The weight loss of 961 packaged was lower $(7.0{\sim}8.0%)$ that those of wrap packaged and PD941 packaged.

  • PDF

A Study on the Environmental Characteristics of a Two-storey Pig House for the Control of Manure (고상식돈사의 분뇨처리에 관한 연구)

  • Jeong, J.W.;Yoo, Y.H.;Park, K.H.;Kam, D.H.;Lee, M.J.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.3
    • /
    • pp.175-182
    • /
    • 2008
  • This research was conducted to examine proper manure treatment methods for a high-rise swine barn with results of the fact-finding survey on manure treatment methods used in high-rise swine barns and sawdust swine barns In Korea. The average temperatures on bedding of control, T1, and T2 were between $25.3{\sim}25.4^{\circ}C$ with little difference. Air flow rate of T2 was slower than those of control and T1. Dust generation in control was 54 cpm which was higher than T1 and T2. The average ammonia concentration in control was highest showing 6.0 ppm, ranged from 0.5 to 14.5 ppm, with statistical difference (p<0.05), compared to T1 (2.8 ppm) and T2 (2.6 ppm). Sawdust spreading used in control and T1 decreased ammonia concentration. T1 showed the lowest concentration of $CO_2$. Water contents of control and T2 were close to the proper water content, 65%. T1 had the highest water content and pH, and the lowest organic matter and C/N ratio. The volumes of sawdust spread per head were 0.26 and $0.27m^3$ in control and T2, respectively, which was less than T1. Operating cost such as an electricity bill for blowers was cheap in T2. Hence, T2 bedding sawdust up to 10 cm thick and periodically spreading additional sawdust from second story was recommended.

  • PDF

Effects of Size and Environmental Condition on Burrowing of Artificial Seedling of Ark Shell, Scapharca broughtonii (Schrenck) (피조개, Scapharca broughtonii (Schrenck) 인공치패의 크기 및 환경조건이 잠입에 미치는 영향)

  • Kim, Byeong-Hak;Shin, Yun-Kyung;Choi, Nack-Joong;Oh, Bong-Se;Sohn, Sang-Gyu;Jung, Choon-Goo;Son, Tai-Sun;Kang, Kyoung-Ho
    • The Korean Journal of Malacology
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2007
  • The influence of individual size, sediment, gain size, water temperature, salinity and air exposure on burrowing rate was investigated in order to obtain the basic biological data on applying shellfish farm for a sustainable production of ark shell, Scapharca broughtonii (Schrenk). The burrowing rate on individual size 300 minutes after starting the experiment was the highest in the shell length $16.3\;{\pm}\;1.2\;mm$, 97.7%. The highest burrowing rates were 97.0% in $12.8\;{\pm}\;0.8\;mm$, 96.7% in $9.2\;{\pm}\;1.0\;mm$, and 96.3% in $5.9\;{\pm}\;0.7\;mm$. The clams over 6 mm of shell length had burrowing ability and the burrowing rate was not related to the shell size. The burrowing rate depending on the kind of grain at the bottom after 300 minutes was the highest, 98.3%, in the mixture of sand and silt with a ratio of 75:25. The rates were 98% in silt (100%), 97.3% in mixture sand and silt with a ratio of 50:50, 97.3% in sand and silt ratio of 25:75, and 86.3% in sand (100%) in this specific order. On grain size of the soil in the seafloor, the burrowing rates after 300 minutes was at its highest in the group of sand in pore size 1 mm with 85.0%, and the $12\;{\mu}m$ to 1 mm in the grain size was fitted to burrowing of artificial seed. In the case of water temperature, the burrowing rates were at its highest after 300 minutes. In $30^{\circ}C$ group, the rate was 96.7% and in $25^{\circ}C$ and $20^{\circ}C$, 90.0%. The rates decreased as the water temperature decreased below $15^{\circ}C$. The burrowing rates on salinity were the highest in 30 psu with 93.3% and at 15 psu and below, there was no noticeable change in the burrowing rate. On air exposure, the burrowing rates after 300 minutes were the highest in 1 hour with 93.3%, and remarkably decreased as air exposure time is longer after 12 hours of air exposure.

  • PDF

Evaluation of Air Ion According to the Distance in Large Flat Park - Focused on Olympic Park in Songpa-gu, Seoul - (대규모 평지형 공원 내 거리별 공기이온 평가 - 서울시 송파구 올림픽공원을 사례로 -)

  • Kim, Jeong Ho;Lee, Sang Hoon;Lee, Myung-Hun;Yoon, Yong Han
    • Korean Journal of Environment and Ecology
    • /
    • v.34 no.5
    • /
    • pp.491-499
    • /
    • 2020
  • Increasing impervious surfaces can cause various physical and mental illnesses as well as further problems like deterioration of the thermal environment and disconnection of the water circulation system in the downtown area. This study is intended to suggest baseline data for the future creation or remodelation of large-scaled urban parks in consideration of human health on the aspect of climate by analyzing air ions condition and correlation analysis between air ions and meteorological elements depending on distances from the center in the urban park. The study site was divided into four types by distances from the center of Olympic Park in Songpa-gu, Seoul, then classified as A and B. After selecting 80 points to record, land coverage and vegetation status were investigated, and then meteorological elements and air ions were measured. First, the green space rate by section is A section Center (90%)> Inner (70%)> Outer-inner (10%) = Outer (10%), B section Center (100%)> Inner (60%)> Outer- In order of inner (30%)> Outer (0%). Second, for weather factors, the temperature was analyzed by Outer (24.18℃) > Outer-inner (22.90℃) > Inner (22.43℃) > Center (21.719℃). For relative humidity, center (46.49%) > Inner (43.36%) > Outer-inner (42.41%) > Outer (38.53%) was analyzed. Third, In the case of cations in the air ions, Outer(435.71ea/㎤) > Outer-inner(415.16ea/㎤) > Inner (389.46ea/㎤) > Center (352.64ea/㎤). In the case of negative ions, Center (569.72ea/㎤) > Inner (499.83ea/㎤) > Outer-inner(410.58ea/㎤) > Outer (292.02ea/㎤). It was analyzed to increase toward Center, and analyzed to decrease with increasing distance from road. For the Air ion index, it was analyzed as Center (1.67) > Inner (1.31) > Outer-inner (1.08) > Outer (0.71). Negative irons was analyzed to increase when its measuring points close to the center and decrease with shortening distance to the road. Fourth, as a result of correlation analysis, positive(+) correlation is negative ions and ion index. These were measured to increase as the recording points closing to the center of the park from the road. The negative(-) correlation is temperature, solar radiation, and positive ions. These increased as getting closer to the road.

Air-staging Effect for NOx Reduction in Circulating Fluidized Bed Combustion of Domestic Unused Biomass (국내 미이용 바이오매스 순환유동층 연소에서 NOx 저감을 위한 air-staging 효과)

  • Yoon, Sang-Hee;Beak, Geon-Uk;Moon, Ji-Hong;Jo, Sung-Ho;Park, Sung-Jin;Kim, Jae-Young;Seo, Myung-Won;Yoon, Sang-Jun;Yoon, Sung-Min;Lee, Jae-Goo;Kim, Joo-Sik;Mun, Tae-Young
    • Korean Chemical Engineering Research
    • /
    • v.59 no.1
    • /
    • pp.127-137
    • /
    • 2021
  • Air emission charge for nitrogen oxide as a precursor of fine dust has been introduced and implemented within the country from 2020. Therefore, the development of economical combustion technology for NOx reduction has got more needed urgently. This study investigated the air-staging effect as a way to reduce the NOx during combustion of domestic unused forest biomass, recently possible to secure REC (Renewable Energy Certification) as a substitute for overseas wood pellets in a 0.1 MWth circulating fluidized bed combustion test-rig. Operating conditions were comparison with and without air-staging, the supply position of tertiary air (6.4 m, 8.1 m, 9.4 m in the combustor) and variation of air-staging ratio (Primary air:Secondary air:Tertiary air=91%:9%:0%, 82%:9%:9%, 73%:9%:18%). NO and CO concentrations in flue gas, profiles of temperature and pressure at the height of the combustion, unburned carbon in sampled fly ash and combustion efficiency on operating conditions were evaluated. As notable results, NO concentration with air-staging application under tertiary air supply at 9.4 m in the combustor reduced 100.7 ppm compared to 148.8 ppm without air-staging while, CO concentration increased from 52.2 ppm without air-staging to 99.8 ppm with air-staging. However, among air-staging runs, when tertiary air supply amount at 6.4 m in the combustor increased by air-staging ratio (Primary air:Secondary air:Tertiary air=73%:9%:18%), NO and CO concentrations decreased the lowest 90.8 ppm and 66.1 ppm, respectively. Furthermore, combustion efficiency at this condition was improved to 99.3%, higher than that (98.3%) of run without air-staging.