• Title/Summary/Keyword: 공기구

Search Result 701, Processing Time 0.025 seconds

A Study on Buzz Margin Control in Supersonic Engine Intake using PID Controller (PID 제어기를 이용한 초음속 엔진 흡입구의 버즈마진 제어에 관한 연구)

  • Kong, Chang-Duk;Ki, Ja-Young;Kho, Seong-Hee;Kang, Myoung-Cheol
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.88-92
    • /
    • 2009
  • Total pressure recovery ratio in intake is crucial factor to the operational characteristics of supersonic propulsion system because it does not compress inlet air mechanically by compressor, but does compress inlet air by ram compression. As the result of that the dynamic characteristic analysis of engine was performed before the controller was designed, it could be ascertained when the AoA of flight vehicle increases, the buzz margin decreases so that the shock wave produced outside intake in the specified area according to flight operation's characteristics. Therefore the PID control algorithm was designed to be controlled buzz margin that the characteristic of shock wave could meet the requirement of performance in intake. The PID controller was designed that the buzz margin value is being positive number using the control variables; fuel flow and nozzle throat area.

  • PDF

The Variation of Air Temperature and Humidity of Rock Bed Storage for Solar-Heated Greenhouse in Summer Season (여름철 자갈축열 태양열 온실의 축열층 온.습도 변화)

  • 이석건;이종원;이현우;김길동
    • Proceedings of the Korean Society for Bio-Environment Control Conference
    • /
    • 2000.10b
    • /
    • pp.128-131
    • /
    • 2000
  • 자갈축열 태양열 온실에 있어 여름철 냉방에너지의 효과적인 절감 방안을 모색하고자 축열 및 배기시스템의 작동방식을 다르게 하여 주ㆍ야간 축열과 방열시 자갈축열층의 온습도환경을 분석한 결과를 요약하면 다음과 같다. 1. 주간에 외기온이 28.5$^{\circ}C$-35.3$^{\circ}C$범위에서 변화할 때 자갈축열층내로 유입되는 공기의 온도는 30.5$^{\circ}C$-36.2$^{\circ}C$, 자갈축열층에서 온실내부로 유출되는 공기의 온도는 28.2$^{\circ}C$-30.1$^{\circ}C$, 축열층 내부온도는 27.4$^{\circ}C$-35.9$^{\circ}C$ 범위였다. 또한, 10시간 축열시 자갈축열층 내부온도는 측점에 따라 1.7$^{\circ}C$-7.$0^{\circ}C$의 온도상승이 있었으며 유입구에서 멀어질수록 축열층 온도는 낮게 나타났으며 온도상승 속도 또한 감소하는 경향으로 나타났다. 그리고, 야간에 축열시스템을 작동하지 않고 배기팬만을 작동하였을 경우, 외기온이 27.4$^{\circ}C$-34.4$^{\circ}C$범위일 때 자갈축열층 내부온도는 29.7$^{\circ}C$-34.9$^{\circ}C$(평균 31.4$^{\circ}C$)범위였으며 온실외부에 설치되어 있는 배기구와 배기팬의 영향으로 축열층 내부온도는 시간이 경과함에 따라 감소하는 경향으로 나타났으며 측점에 따라 2.2$^{\circ}C$-5.1$^{\circ}C$(평균 2.8$^{\circ}C$)의 온도하강 효과가 있는 것으로 나타났다. 2. 여름철 주간에 10시간 축열시 자갈축열층 내부습도는 측점에 따라 8.1%-26.3%의 감소현상이 있었다. 또한, 유입구에서 멀어질수록 축열층 습도는 높게 나타났으며 습도하강속도 또한 감소하는 경향으로 나타나 유입구에서 멀어질수록 외부습도의 영향을 적게 받는 것으로 분석되었다. 하지만, 야간에는 배기시스템의 영향으로 자갈축열층의 습도는 외기의 영향을 많이 받는 것으로 나타났다.

  • PDF

Mach 5 Performance Tests of Scramjet Engine Intake Using Free-jet Type Ground Propulsion Test Facility (자유제트형 지상추진 시험설비를 사용한 스크램제트 엔진 흡입구의 마하 5 성능시험)

  • Lee, Yang Ji;Yang, Inyoung;Lee, Kyung Jae;Oh, Jung Hwan;Choi, Jin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.4
    • /
    • pp.10-20
    • /
    • 2022
  • The performance analysis test of the scramjet engine intake was conducted under the Mach 5 condition of the scramjet engine test facility, a free-jet ground test facility of the Korea Aerospace Research Institute. A pitot/static pressure rake installed at the rear of the isolator was designed and manufactured to measure the total pressure recovery rate and mass capture ratio, which are typical performance factors of the scramjet engine intake. The effect of the rake mounted at the rear of the isolator on the intake, the performance analysis measured by the rake, and the change in wall static pressure distribution according to the angle of attack were performed. Finally, the point at which the intake unstart occurred was confirmed by using the rear back pressure adjusting device, which simulates pressure rise in the combustor, and the results are summarized in this paper.

Design of the Submerged Outlet Structure for Reducing Foam at a Power Plant using a Numerical Model Simulating Air Entrainment (공기연행 수치모형을 이용한 발전소 거품저감 수중방류구조 설계)

  • Kim, Ji-Young;Kang, Keum-Seok;Oh, Young-Min;Oh, Sang-Ho
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.20 no.5
    • /
    • pp.452-460
    • /
    • 2008
  • Anti-foaming agents and foam fences have been used to remove the foam at the outfall of power plants, but there are some problems as consumption of maintenance costs and insufficiency of effect. Therefore, development of the methods how to remove the foam by stable coastal structure has been required. In this study, numerical simulation of air entrainment was carried out to design the submerged outlet structure for reducing foam using curtain walls. The air entrainment rate and the discharge of entrained air change according to the shape of weir and curtain wall. Hence, it is necessary to design the optimum section through comparison of each case. The optimum section which has the maximum rate of foam reduction was determined by the simulation results. In addition, it was found that the flow velocity at the submerged outlet is to be smaller than 1 m/s and the submerged depth of curtain wall is to be taller than height of the submerged outlet section.

Effect of Air Ejection on the Behaviors of Sows and their Piglets Related to the Crushing of Piglets by Sows (공기분사가 모돈과 포유자돈의 압사 관련 행동에 미치는 영향)

  • Jeon, J.H.;Yeon, S.C.;Chang, H.H.
    • Journal of Animal Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.691-696
    • /
    • 2005
  • Suckling piglets must avoid positions with high air velocity because they don’t have hypodermic fat. Therefore this study examined the effects of air ejection on the behaviors of sows and their piglets. Compressed air was released for 5s at 5s intervals between floor and udder of sows only when they were standing or sitting. Sixteen multiparous crossbred(Landrace×Yorkshire) sows and their piglets were used. Behaviors of sixteen sows and their piglets were recorded for 4 days postpartum, using the LED lamp(wavelength:950nm), CCD camera(Samsung SDC-411), multiplexer(Samsung SDM-080), and time lapsed VCR(Samsung SRV-30). The videotapes were scanned every 30s to obtain an instantaneous behavioral sample. The sow’s standing and sitting rates between control group(CG) and air ejection group(AEG) were not significantly different(P>0.05). This means that air ejection does not affect the behavior of sows. Frequency of the suckling piglets’ behaviors closely related to the crushing by sows was lower in AEG than in CG(P<0.05). These results suggest that air ejection may be available for reduction of the crushing of suckling piglets by sows.

Measurement of Air Velocity Using a Slanted Hot-wire (경사진 Hot-wire probe를 사용한 공기속도의 측정에 관한 연구)

  • Chang, Tea Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.1
    • /
    • pp.21-31
    • /
    • 1989
  • 본 연구에서는 경사진 hot-wire probe 의 특성값을 구하고 열선풍속계의 응답식으로부터 수평원통관내에서 3차원 흐름의 속도성분과 난류 강도 그리고 전단 응력을 pitot tube의 결과와 비교 연구하였다. 또한, 속도 및 난류 강도에 관한 유도된 식을 swirling flow에도 적용하여 만족한 결과를 얻었다.

  • PDF

업계탐방 - 분당서울대학교

  • O, Jeong-Gyu
    • 방재와보험
    • /
    • s.126
    • /
    • pp.68-69
    • /
    • 2008
  • 이번 탐방은 중앙지부의 추천으로 경기도 성남시 분당구 구미동 300번지에 위치한 분당 서울대학교병원을 방문하였다. 불곡산의 푸른 공기와 탄천의 맑은 물이 어우러진 넉넉한 자연의 품에 안긴 모습이 병원이라기보다는 휴양시설에 온 느낌이다. 이곳에서 방화관리를 담당하는 시설팀 이홍규 과장을 만나 시설현황과 안전관리현황, CEO의 경영철학 등에 관한 이야기를 나누어 보았다.

  • PDF

A Study on Substantiation Methodology for Extension of Time in International Mega-Project Claims (해외 대형건설공사 공기지연클레임의 공기연장기간 입증방법)

  • Kim, Young-jae;Kim, Tae-kyoung;Jo, Duk-sang;Lee, Hwang-ku
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.3
    • /
    • pp.165-176
    • /
    • 2015
  • Recently many Korean large-sized construction companies as well as specialty contractors have been expanding their business in the overseas market to mitigate impacts from long-term stagnation in the domestic market. Such as a result, it has been arisen as a major issue that contractors effectively manage the delays which have been commonly faced with in international mega-projects. Therefore it can be said that the ability of the delays management leads a success of project. This paper presents a review of literature for delay analysis methods such as time impact analysis(TIA) and raises practical problems to rationally substantiate the duration of extension of time(EoT) in international mega projects which have wide scope of works as well as complicated and detailed contract baseline programs by taking theoretical approaches. We suggest the two improvement concepts to substantiate the EoT claims which are effectively applicable to practical projects. The first is to sort out dominant delays among numerous delays in advance of applying a delay analysis. The second is to set up the delay sections with the advanced concept for analysing delays' effects by TIA. This study performed a case study on an actual international mega-project. to confirm the effectiveness of improvement concepts that this practical approach is applicable for the assessment of EoT. In conclusion, this paper supposes to provide practitioner in charge for an EoT claim with an advanced substantiation methodogy when they not only analyse the construction delays by using TIA, but also negotiate with stakeholders about with the assessment of EoT.

Membrane Module for Greenhouse CO2 Supply Removal Effect of Harmful Pathogen (Phoma sp.) (온실 CO2 공급용 Membrane Module의 유해병원균(Phoma sp.)의 제거효과)

  • Kim, Seong-Sik;Kim, Hee-Tae;Jo, Jae-Min;Cho, Won-Jun;Kim, Hyeon-Tae
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.33-33
    • /
    • 2017
  • 본 연구는 온실 $CO_2$ 공급용 Membrane Module이 대기 중 $CO_2$를 포집하는 과정에서 유해병원균을 제거할 수 있는지 알아보기 위해 실험을 진행하였다. 본 실험은 Membrane Module과 유해병원균의 유무로 총 4개의 실험구, 포집하는 시간에 따라 1 min, 3 min, 5 min, 각각 3회씩, 총 36회의 실험을 진행하였다. 실험은 경상대학교 내 온실($W{\times}D{\times}H$, $3000{\times}4000{\times}2500mm$)에서 진행하였고, 유해병원균은 잎점무늬병을 일으키는 병원균(Phoma sp.)을 사용하였다. 온실에 Membrane System을 설치하고 Membrane Module을 통해 외부공기 또는 유해병원균이 포함된 공기를 분리하여 온실 내로 공급하고, 공급한 $CO_2$ 내에 유해병원균의 유무는 에어샘플러를 이용하여 온실 내의 공기를 포집 후 배지에 배양하여 확인하였다. 유해병원균은 PDA배지를 이용하여 포집한 뒤 항온항습기(HB-105SG-O, HANBAEK SCIENTIFIC CO., Korea)에 $25^{\circ}C$, 50%로 48시간 배양하였다. PDA배지 내에 배양된 미생물은 Colony Counter(HYC-560, CORETECH, Korea)로 측정하였다. 결과 값을 분석하기 위해서 IBM SPSS Statistics의 이원분산분석(two-way ANOVA)을 이용하여 통계분석 하였다. 결과 값은 유해병원균을 공급하고 Membrane Module을 사용하지 않았을 때, CFU(Colony-Forming Unit)가 가장 높았고, 유해병원균을 공급하고 Membrane Module을 사용했을 때 CFU가 가장 낮았다. 통계분석을 실시한 결과, Membrane Module을 사용하지 않은 실험구에는 유의한 차이가 나타났고, Membrane Module을 사용한 실험구에는 유의한 차이가 나타나지 않았다. 따라서 Membrane Module이 대기 중 $CO_2$를 분리하여 온실에 공급하는 과정에서 공기 중에 포함된 유해병원균을 제거 할 수 있다고 판단된다.

  • PDF

화학제제를 깔짚에 첨가시 육계의 생산성과 계사내의 암모니아 발생에 미치는 영향에 관한 연구

  • 최인학;손장호;남기홍
    • Proceedings of the Korea Society of Poultry Science Conference
    • /
    • 2003.11a
    • /
    • pp.123-124
    • /
    • 2003
  • 6개의 화학제제를 육계의 깔짚에 첨가한 후 6주간의 사육기간 동안 육계의 생산성, 계사 내의 암모니아 발생량을 측정하여 6개의 화학제제를 대조구와 비교하였다. 본 실험은 A계사와 B계사 각각에 대조구(4케이지)와 시험구(4케이지)를 배치하였으며 대구대학교 동물사육실에서 실시하였다. 시험은 각 방에서 4반복으로 실시하였다. A계사는 화학제제 I (T$_1$)을 깔짚에 첨가하고 나머지는 대조구로 하였다. B계사에는 화학제제II(T$_2$)를 깔짚에 첨가하고 나머지는 대조구로 하였다. 대조구와 실험구는 철저히 막아서 공기가 서로 내통되지 않게 하였다. 화학제제 I (T$_1$)과 II(T$_2$)의 실험이 끝난 후 같은 방법으로 화학제제III(T3)과 IV(T4)도 실시하였으며 계속해서 화학제제V(T$_{5}$)와 Ⅵ(T$_{6}$)이 실시되었다. 총 시험기간은 2002년 10월 31일부터 익년 3월 22일까지 143일간 계속되었다. 6개의 화학제제를 각각 깔짚에 첨가하였을 때 대조구에 비교하여 육계의 생산성에는 아무런 차이가 없었다. 암모니아 가스 농도는 화학제제 I (T$_1$)과 II(T$_2$)의 경우 2주에서 6주까지 처리구와 대조구간의 차이를 나타내었다. 화학제제III(T$_3$)의 처리구는 5주 동안 암모니아 가스발생은 거의 없었으며 대조구와는 큰 차이를 나타냈다. 화학제제IV(T$_4$)와 V(T$_{5}$) 그리고 Ⅵ(T$_{6}$)에서도 처리구와 대조구간에 차이가 인정되었으나 처리IV(T$_4$)와 Ⅵ(T$_{6}$)의 경우는 처리구에서도 5주와 6주의 경우 암모니아 농도는 25 ppm이거나 그 이상을 유지하였다. 모든 처리구에서 계사내 암모니아 가스농도는 25 ppm보다 낮았으나 화학제제III(T$_3$)에서는 계사내의 암모니아 가스 발생량은 거의 0에 가까웠다. 결론적으로 6개의 처리들간의 비교는 할 수 없지만 화학제제III(T$_3$)의 경우에서 처리구는 암모니아 가스 발생량을 다른 처리구에 비교하여 가장 낮게 나타났다.

  • PDF