• Title/Summary/Keyword: 공극분포

Search Result 385, Processing Time 0.03 seconds

An Experimental Study on the Microstructure Characteristics of Cementitious Composites by MIP (MIP를 통한 혼합 시멘트계 재료의 미세구조 특성에 관한 실험적 연구)

  • Kim, Tae-Sang;Jung, Sang-Hwa;Chae, Seong-Tae;Lee, Bong-Chun;Woo, Young-Je;Song, Ha-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.533-536
    • /
    • 2008
  • Recently, in Korea, there has been an increasing number of research papers published which are to improve durability of concrete, particularly by analyzing correlation between diffusivity of chloride and porosity/pore size distribution. In these studies, such test methods as mercury intrusion porosimetry(MIP), gas adsorption or image analysis method are used to analyze the microstructure of materials while MIP is most widely used for concrete. This study analyzes the results of porosity and pore size distribution of paste and concrete adding fly ash or blast furnace slag by using MIP equipment which is widely used for determining micro-porosity structure of cementitious materials. A variation in porosity and pore size distribution at the curing day 3, 7 and 28 has been observed by using MIP equipment for cement paste 35%, 40%, 45%, 50%, 55%, 60% of W/C when using $300kg/m^3$ of cement, 35%, 45%, 55% of W/C when replaced 60% with blast-furnace slag, and 35%, 45%, 55% of W/C when replaced 30% with fly ash. For long-term water cured normal OPC concrete and mixed concrete replaced 60% with blast-furnace slag powder, micro-structure of the sample has been analyzed by using MIP equipment when W/C indicated 40%, 45%, 50% respectively and the binder varied $300kg/m^3$, $350kg/m^3$, $400kg/m^3$, and $450kg/m^3$.

  • PDF

Primary study on evaluation of wetting front distribution for weathered soil (토층 사면에서의 침윤선 분포 특성 파악을 위한 실험 연구)

  • Kim, Man-Il;Chae, Byung-Gon;Seo, Yong-Seok;Kim, Hyeun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1395-1399
    • /
    • 2008
  • 국내 토층 사면을 대상으로 강우에 의해 발생되는 침투수 거동 특성을 분석함으로써 지속적인 토층의 물성 변화 계측을 통해 산사태 예 경보시스템을 구축이 가능하다. 본 연구에서는 산사태 예 경보시스템 구축의 사전 단계로써, 국내 대표적인 지질 매질인 화강암 풍화토, 편마암 풍화토와 주문진 표준사에 대해 공극률과 체적함수비 등의 토질 물성 변화를 고려한 실내 보정실험을 수행하였다. 실험조건은 공극률, 체적함수비 변화에 대한 측정센서의 측정 정밀도 향상과 이를 통해 국내 현장토에 대한 고유 보정기법을 제시하기 위함이다. 측정센서는 각 실험 조건별 물성 변화에 따라 전압을 측정함으로써 현장토에 대한 물성치와 상호 분석이 가능하도록 하였다. 주문진 표준사 뿐만 아니라 국내 현장토인 화강암 풍화토와 편마암 풍화토에 대한 체적함수비에 대한 보정식도 함께 제시하였다.

  • PDF

The Effect of Lateral Displacement on the Performance in the Controlled-PM LSM (횡변위가 제어-영구자석형 선형동기전동기의 특성에 미치는 영향)

  • Lee, Ju
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.5
    • /
    • pp.308-316
    • /
    • 1998
  • In this paper, the effects of lateral displacement on the thrust, lift force and (guide force) are investigated by 3-D Finite Element Analysis (FEA) in controlled-PM LSM which has some strong points that electrical power can be minimized and the thrust and lift force can be simultaneously obtained. The variations of airgap flux density and the forces concerning lateral displacement have been analyzed and the effect of lateral displacement and airgap length on the motor performance have been investigated in detail by analysis and experiment results. As the result of this study, the characteristics of PM-LSM concerning with the change of lateral placement and airgap have been made clear quantitatively.

  • PDF

A Study on Change in Cement Mortar Characteristics under Carbonation Based on Tests for Hydration and Porosity (수화물 및 공극률 관측 실험을 통한 시멘트모르타르의 탄산화 특성 변화에 대한 연구)

  • Kwon, Seung-Jun;Song, Ha-Won;Park, Sang-Soon
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.5
    • /
    • pp.613-621
    • /
    • 2007
  • Due to the increasing significance of durability, much researches on carbonation, one of the major deterioration phenomena are carried out. However, conventional researches based on fully hardened concrete are focused on prediction of carbonation depth and they sometimes cause errors. In contrast with steel members, behaviors in early-aged concrete such as porosity and hydrates (calcium hydroxide) are very important and may be changed under carbonation process. Because transportation of deteriorating factors is mainly dependent on porosity and saturation, it is desirable to consider these changes in behaviors in early-aged concrete under carbonation for reasonable analysis of durability in long term exposure or combined deterioration. As for porosity, unless the decrease in $CO_2$ diffusion due to change in porosity is considered, the results from the prediction is overestimated. The carbonation depth and characteristics of pore water are mainly determined by amount of calcium hydroxide, and bound chloride content in carbonated concrete is also affected. So Analysis based on test for hydration and porosity is recently carried out for evaluation of carbonation characteristics. In this study, changes in porosity and hydrate $(Ca(OH)_2)$ under carbonation process are performed through the tests. Mercury Intrusion Porosimetry (MIP) for changed porosity, Thermogravimetric Analysis (TGA) for amount of $(Ca(OH)_2)$ are carried out respectively and analysis technique for porosity and hydrates under carbonation is developed utilizing modeling for behavior in early-aged concrete such as multi component hydration heat model (MCHHM) and micro pore structure formation model (MPSFM). The results from developed technique is in reasonable agreement with experimental data, respectively and they are evaluated to be used for analysis of chloride behavior in carbonated concrete.

Performance Moment Integration (PMI) for Prediction Performance Changes of a Loudspeaker Model Due to the Uncertainty of Design Variables (성능 모멘트 적분법을 이용한 설계 변수의 불확실성에 기인한 스피커 모델의 성능 변동 예측)

  • Kang, Byung-Su;Lee, Sang-kyun;Kim, Dong-Wook;Kim, Dong-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.766-767
    • /
    • 2015
  • 전자기 관련 제품에서 제작공차에 의한 성능변동의 확률론적 분포특성을 효율적으로 예측하기 위해 성능 모멘트 적분법을 도입하였다. 제안된 기법을 검증하기 위해 간단한 수학예제와 스피커 모델의 폴피스 사이 공극의 평균자속 밀도에 대한 확률론적 분포특성 예측을 수행하고, 이를 기존 확률론적 분포특성 예측 기법과 비교하였다. 또한 몬테카를로 수치모사법을 이용하여 도출된 성능의 확률론적 분포특성 예측 값을 재계산 후 비교함으로써 제안된 기법의 정밀도를 검증하였다.

  • PDF

Physical Properties of Major Bedrocks in Chungju-Goesan Area as Aggregates (충주-괴산일대에서 산출되는 주요 기반암의 골재로서의 물성특징)

  • Byoung-Woon You;Jaehyung Yu
    • Economic and Environmental Geology
    • /
    • v.55 no.6
    • /
    • pp.649-659
    • /
    • 2022
  • This study examined the granite, quartzite, phyllite, schist, and gneiss as aggregate resources among the original rock distributed in the Chungju-Goesan area. The granite distributed in the study area is mainly composed of Jurassic biotite granite, and the quartzite layer is from the Daehyangsan quartzite Formation distributed on the upper part of the Gyemyeongsan Formation and the Hyangsan-ri dolomitic limestone Formation. In addition, phyllite is pophyrytic phyllite-schist from the Hwanggangri Formation of the Okcheon group, schist is chlorite schist, from the Munjuri Formation of the Okcheon group, and gneiss is porphyroblastic gneiss which is the upper part of the Seochangri Formation. Aggregate quality evaluation factors of these rocks included fineness modulus, absorption, unit weight, absolute dry density, solid content, porosity, resistance to abrasion, and soundness. In the case of granite, it was found to be partially unsatisfactory in terms of unit weight, solid content, porosity, and resistance to abrasion. Gneiss was found to be out of the standard values in resistance to abrasion and schist in porosity and solid content. As for the overall quality of aggregate resources, it was analyzed that quartzite, gneiss, and phyllite showed excellent quality. Aggregate quality tests are performed simply for each rock, but the rock may vary depending on the morphology of the mineral. Therefore, when analyzing and utilizing the quality evaluation of aggregate resources, it will be possible to use them more efficiently if the rock-mineralological research is performed together.

Comparison of Correlation between Chloride Diffusion and Pores Characteristics in Concrete Cured under Extreme Condition (가혹 조건에서 양생된 콘크리트의 염화물 확산과 공극 특성의 상관관계 비교 )

  • So Yeong Choi;Seong Joon Yang;Il Sun Kim;Eun Ik Yang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.4
    • /
    • pp.54-61
    • /
    • 2023
  • In this paper, the compressive strength, pore characteristics, and chloride diffusion coefficient were measured at 28 days of age in order to examine the influence of curing conditions for the chloride diffusion and pores in concrete cured under extreme condition. According to the test results, the compressive strength was improved as the relative humidity increased. Additionally, higher compressive strength was observed when the specimens were cured at 35℃. However, the compressive strength of specimens cured at 45℃ was decreased. Meanwhile, the chloride diffusion coefficient decreased with an increase in curing temperature and relative humidity, indicating a difference compared to the trend observed for compressive strength. On the other hand, the excellent correlation showed between compressive strength and chloride diffusion coefficient, porosity and chloride diffusion coefficient when the concrete cured under water. However, when the concrete cured under extreme condition, this correlation was significantly reduced compared to the water curing case. In contrast, it has been determined that there is no significant correlation between the average pore size and chloride diffusion coefficient, regardless of the curing conditions.

Air Contents & Size Distribution of Air Voids in Concrete Using Image Analysis (이미지 분석에 의한 콘크리트의 공극 분포 및 공기량 분석)

  • Kwon, Hyouk-Chan;Jeong, Won-Kyong;Yun, Kyong-Ku
    • Journal of Industrial Technology
    • /
    • v.24 no.A
    • /
    • pp.157-164
    • /
    • 2004
  • Air voids in hardened concrete have an important influence on concrete durability such as resistance of freezing and thawing, permeability and surface scaling resistance. Linear traverse method and point count method in ASTM standard method have been widely used to estimate the air void system in hardened concrete. However, these methods are not used at present time, because they are is exhausted much time and effort. In previous study, air voids system of concrete was estimated by spacing factor. The purpose of this study organizes image analysis method by analyzing air contents, air voids distributions by diameters, air voids system as well as spacing factors after hardened concrete. The experimental variables institute of depth of specimen(top, middle, bottom), air contents(AE contents 0, 0.01, 0.03%).

  • PDF

A Study on the Drain Performance & Pore Structure of Cellular Mortar which Drain Material of the Composite Lining Method (Composite 라이닝 공법의 배수공 재료인 경량기포모르타르의 공극구조와 배수성능에 대한 고찰)

  • Choi, Hee-Sup;Ma, Sang-Joon;Lee, Heung-Soo;Seo, Shin-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.425-426
    • /
    • 2009
  • As a result of the Mercury Intrusion Porosimetry(MIP) test, FCR Batch with the continuous voids in excellent permeability is appeared with the Cellular Mortar that is most suitable which Drain Material of the Composite Lining Method.

  • PDF

Investigation and Theoretical Analysis of a Fire Accident Caused by Smoldering Combustion (Smoldering 연소로 인한 화재사고 조사보고 소개 및 이론적 해석)

  • 김연승;변영철;황정호
    • Fire Science and Engineering
    • /
    • v.13 no.3
    • /
    • pp.3-17
    • /
    • 1999
  • Smoldering is a non-flaming combustion mode, characterized by thermal degradation and c charring of the virgin material, evolution of smoke and emission of visible glow. A big fire may @ occur even in a confined environment having a limited amount of oxygen, due to smoldering c combustion through a porous solid material. This paper presents a theoretical analysis on the effect of smoldering combustion on fire occurrence based on a report about fire investigation of a real f fire accident. It is assumed that the propagation of the smolder wave is one-dimensional, d downward, opposing an upward forced flow and steady in a frame of reference moving with the s smolder wave. Smoldering combustion is modeled by a one-step reaction mechanism, without c considering pyrolysis. It is found that dominant parameters controlling smoldering combustion i include mass flux of oxidizer entering the reaction zone and void fraction of solid fuel. It is also found that the mechanism of transition to flaming is critically influenced by these two parameters.

  • PDF