• Title/Summary/Keyword: 공간 분해능

Search Result 198, Processing Time 0.033 seconds

An Evaluation For Spatial Resolution, Using A Single Target On A Medical Image (의료영상에서 단일 표적을 이용한 공간분해능 평가)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.631-636
    • /
    • 2016
  • Hitherto, spatial resolution has commonly been evaluated by test patterns or phantoms built on some specific distances (from close to far) between two objects (or double targets). This evaluation method's shortcoming is that resolution is restricted to target distances of phantoms made for test. Therefore, in order to solve the problem, this study proposes and verifies a new method to efficiently test spatial resolution with a single target. For the research I used PSF and JND to propose an idea to measure spatial resolution. After that, I made experiments by commonly used phantoms to verify my new evaluation hypothesis inferred from the above method. To analyse the hypothesis, I used LabVIEW program and got a line pixel from digital image. The result was identical to my spatial-resolution hypothesis inferred from a single target. The findings of the experiment proves only a single target can be enough to relatively evaluate spatial resolution on a digital image. In other words, the limit of the traditional spatial-resolution evaluation method, based on double targets, can be overcome by my new evaluation one using a single target.

Design of Gamma Camera with Diverging Collimator for Spatial Resolution Improvement (공간분해능 향상을 위한 확산형 콜리메이터 기반의 감마카메라 설계)

  • Lee, Seung-Jae;Jang, Yeongill;Baek, Cheol-Ha
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.661-666
    • /
    • 2019
  • Diverging collimators is used to obtain reduced images of an object, or to detect a wide filed-of-view (FOV) using a small gamma camera. In the gamma camera using the diverging collimators, the block scintillator, and the pixel scintillator array, gamma rays are obliquely incident on the scintillator surface when the source is located the periphery of the FOV. Therefore, the spatial resolution is reduced because it is obliquely detected in depth direction. In this study, we designed a novel system to improve the spatial resolution in the periphery of the FOV. Using a tapered crystal array to configure the scintillation pixels to coincide with the angle of the collimator's hole allows imaging to one scintillation pixel location, even if events occur to different depths. That is, even if is detected at various points in the diagonal direction, the gamma rays interact with one crystal pixel, so resolution does not degrade. The resolution of the block scintillator and the tapered crystal array was compared and evaluated through Geant4 Application for Tomographic Emission (GATE) simulation. The spatial resolution of the obtained image was 4.05 mm in the block scintillator and 2.97 mm in the tapered crystal array. There was a 26.67% spatial resolution improvement in the tapered crystal array compared to the block scintillation.

Dose Reduction According to the Exposure Condition in Intervention Procedure : Focus on the Change of Dose Area and Image Quality (인터벤션 시 방사선조사 조건에 따른 선량감소 : 면적선량과 영상화질 변화를 중심으로)

  • Hwang, Jun-Ho;Jung, Ku-Min;Kim, Hyun-Soo;Kang, Byung-Sam;Lee, Kyung-Bae
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.393-400
    • /
    • 2017
  • The purpose of this study is to suggest a method to reduce the dose by Analyzing the dose area product (DAP) and image quality according to the change of tube current using NEMA Phantom. The spatial resolution and low contrast resolution were used as evaluation criteria in addition to signal to noise ratio (SNR) and contrast to noise ratio (CNR), which are important image quality parameters of intervention. Tube voltage was fixed at 80 kVp and the amount of tube current was changed to 20, 30, 40, and 50 mAs, and the dose area product and image quality were compared and analyzed. As a result, the dose area product increased from $1066mGycm^2$ to $6160mGycm^2$ to 6 times as the condition increased, while the spatial resolution and low contrast resolution were higher than 20 mAs and 30 mAs, Spatial resolution and low contrast resolution were observed below the evaluation criteria. In addition, the SNR and CNR increased up to 30 mAs, slightly increased at 40 mAs, but not significantly different from the previous one, and decreased at 50 mAs. As a result, the exposure dose significantly increased due to overexposure of the test conditions and the image quality deteriorated in all areas of spatial resolution, low contrast resolution, SNR and CNR.

Micrometer Spatial Resolution Imaging System Using Synchrotron X-ray (Synchrotron X-선을 이용한 Micrometer 공간 분해능 영상시스템)

  • 홍진오;정해조;정하규;제정호;김은경;유형식;김희중
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.2
    • /
    • pp.165-169
    • /
    • 2001
  • 최근 포항 방사광 가속기 연구소에 미세구조 X-선 영상 실험을 위한 5C1 방사광(Synchrtoron Radiation) 빔라인이 건설되었다. 광대역의 에너지 스펙트럼을 가진 방사광 X-선이 물체를 투과한 후 CdWO$_{4}$ scintillator에 의해 가시광선으로 바뀌고, 그 빛을 CCD 카메라로 받아들여 영상을 획득하게 된다. 방사광 X-선은 일반 의료진단용 X-선에 비하여 위상이 일치하고, 평행하며, 그 양이 풍부한 특성들을 갖고 있다. 방사광 영상시스템과 X-선 유방촬영 시스템에서 영상을 획득하여 영상특성들을 비교, 분석하였다. 고-분해능 X-선 시험 패턴(20 line pairs mm$^{-1}$), 유방촬영 팬텀, 파라핀에 고정한 인체 유방암조직과 포르말린에 고정한 인체 유방암조직, 그리고 capillary tube내 micro-bubbles등의 방사광 영상은 기존의 X-선 유방촬영시스템에서 얻은 영상보다 분해능이 뛰어나고 영상질도 우수하였다. 방사광 X-선 영상시스템은 micrometer 공간 분해능 영상을 획득할 수 있어 많은 기초분야의 영상연구와 의료영상분야에서도 활발하게 활용될 것으로 기대된다.

  • PDF

High Spatial Resolution Raman Spectroscopy by Tip-enhanced Effect

  • Park, Gyeong-Deok;Kim, Yong-Hwan;Park, Jin-Ho;Park, Jeong-Su;Lee, Yeong-Hui;Jeong, Mun-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.143-143
    • /
    • 2012
  • 일반적인 라만 분광 시스템은 회절 한계로 인해 공간 분해능이 떨어지며, 시료의 양이 적을 경우에 굉장히 미약하게 발생하는 라만 신호의 검출 감도가 떨어지는 단점이 있다. 본 연구에서는 이러한 문제점을 개선하기 위하여 tip-enhanced Raman spectroscopy (TERS)를 구축하였다. 구축한 TERS 시스템은 뾰족한 금속 탐침을 시료 위에 근접시켜 금속 탐침 내에 존재하는 전자와 여기 광 간의 플라즈몬 공명 현상에 의한 광 안테나 효과를 유도하여 라만 분광 시스템의 공간 분해능을 수십 나노미터 정도로 향상시켰으며, 기존의 라만 분광 시스템에서는 검출되지 않는 미약한 라만 신호를 검출할 수 있었다. 구축한 TERS 시스템을 이용하여 탄소나노튜브를 비롯한 다양한 반도체 시료의 라만 스펙트럼 및 라만이미지를 측정하였고, 금속 탐침이 시료위에 근접되지 않은 경우의 측정 결과와 라만 신호의 세기 및 라만 이미지의 공간 분해능을 비교하여 제안하는 TERS 시스템의 효용성을 검증하였다.

  • PDF

Development of Automatized Quantitative Analysis Method in CT Images Evaluation using AAPM Phantom (AAPM Phantom을 이용한 CT 영상 평가 시 자동화된 정량적 분석 방법 개발)

  • Noh, Sung Sun;Um, Hyo Sik;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.163-173
    • /
    • 2014
  • When evaluating the spatial resolution images and evaluation of low contrast resolution using CT standard phantom, and might present a automated quantitative evaluation method for minimizing errors by subjective judgment of the evaluator be, and try to evaluate the usefulness. 120kVp and 250mAs, 10mm collimation, SFOV(scan field of view) of 25cm or more than, exposure conditions DFOV(display field of view) of 25cm, and were evaluated the 24 passing images and 20 failing images taken using a standard reconstruction algorithm by using the Nuclear Associates, Inc. AAPM CT Performance Phantom(Model 76-410). Quantitative evaluation of low contrast resolution and spatial resolution was using an evaluation program that was self-developed using the company Mathwork Matlab(Ver. 7.6. (R2008a)) software. In this study, the results were evaluated using the evaluation program that was self-developed in the evaluation of images using CT standard phantom, it was possible to evaluate an objective numerical qualitative evaluation item. First, if the contrast resolution, if EI is 0.50, 0.51, 0.52, 0.53, as a result of evaluating quantitatively the results were evaluated qualitatively match. Second, if CNR is -0.0018~-0.0010, as a result of evaluating quantitatively the results were evaluated qualitatively match. Third, if the spatial resolution, as a result of using a image segmentation technique, and automatically extract the contour boundary of the hole, as a result of evaluating quantitatively the results were evaluated qualitatively match.

Limitations of time resolution and spatial overlap caused by group velocity mismatch in experiments using ultrashort UV and visible optical pulses. (자외선과 가시광선 극초단 펄스 실험의 군속도 차이에 의한 시간 분해능 및 공간 겹침의 제한)

  • 김성규
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.252-259
    • /
    • 1994
  • The method of calculating overlap dispersion caused by group velocity mismatch between uv and visible pulses in ultrafast pump-probe experiments is presented to discuss limitations of the time resolution and signal intensity. The calculations show arrangements using a single focusing lens shall result in undesirable time resolution and low signal intensity. Achromatic doublets result in unrealistic solutions. However, dramatic improvement in the time resolution and signal intensity is expected in the optical arrangements using separate lens for each pulse and in the arrangements using a cutoff secondary lens with a main lens. lens.

  • PDF

반도체 공정 플라즈마의 밀도 균일성 분석을 위한 공간 분해 발광 분광기

  • O, Chang-Hun;Ryu, Hun-Cheol;Lee, Hyeong-U;Kim, Se-Yeon;Lee, Heon-Jeong;Han, Jae-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.412-412
    • /
    • 2010
  • 플라즈마는 미세 전기 소자 제작에 있어 박막의 증착, 식각, 세정등 여러 가지 공정에서 널리 사용되고 있다. 미세 소자의 선폭의 감소와 높은 생산성을 위한 웨이퍼 면적의 대형화가 진행됨에 따라 플라즈마의 균일도는 공정 수율 향상의 관점에서 중요한 요소로 그것의 계측과 공정 중 실시간 감시에 필요성이 부각되고 있다. 플라즈마에 존재하는 라디칼의 밀도, 이온의 밀도, 전자 온도 등의 웨이퍼 상에서의 공간 분포와 공정 결과물과의 상관관계에 대한 연구는 현재까지 다양하게 진행 되었으며 특히, 라디칼의 공간 분포가 공정 결과물의 균일도와 큰 상관 관계가 있는 것으로 알려져 있다. 라디칼의 농도 분포를 계측은 레이저 유도 형광법, 발광 분광법, 흡수 분광법 등을 통하여 이루어져 왔으며, 특히 발광 분광법의 경우 계측의 민감성, 편의성등을 이유로 가장 널리 사용되고 있다. 그러나 현재 까지 진행된 발광 분광법을 이용한 라디칼의 공간 분포 계측은 그 자체로 공간 분포를 계측하는 것이 아닌 플라즈마 밀도의 축 대칭성을 가정하여 Abel inversion을 적용하거나, 광섬유를 플라즈마에 직접 삽입하는 방식을 사용하기 때문에 실제 반도체 제작공정을 비롯한 미세소자 공정 플라즈마의 라디칼 밀도 분포를 실시간, 비 접촉 방식으로 계측 하는데 한계가 있다. 본 연구에서는 반도체 공정 플라즈마의 밀도 균일성 분석을 위한 공간 분해 발광 분광기를 제안한다. 기존의 발광 분광법과 비교하여 공간 분해능 향상을 위하여 직렬로 설치된 다수의 렌즈, 개구, 그리고 핀홀을 이용하였다. 공간 분해 발광 분광기의 공간 분해능을 계산하였으며, 실험을 통하여 검증 하였다. 또, HDP CVD를 이용한 $SiO_2$ 박막 증착 공정에서 산소 라디칼의 농도와 증착된 박막의 두께 분포의 상관 관계를 계측 함으로써 공간 분해 발광 분광기의 플라즈마 공정 적용 가능성 입증 하였다.

  • PDF

Comparative Analysis of Land-use thematic GIS layers and Multi-resolution Image Classification Results by using LANDSAT 7 ETM+ and KOMPSAT EOC image (Landsat 7 ETM+와 KOMPSAT EOC 영상 자료를 이용한 다중 분해능 영상 분류결과와 토지이용현황 주제도 대비 분석)

  • 이기원;유영철;송무영;사공호상
    • Spatial Information Research
    • /
    • v.10 no.2
    • /
    • pp.331-343
    • /
    • 2002
  • Recently, as various fields of applications using space-borne imagery have been emphasized, interests on integrated analysis or fusion using multi-sources are also increasing. In this study, to investigate applicability of multiple imageries for further regional-scaled application, DN value analysis and multi-resolution classification by using KOMPSAT EOC imagery and Landsat 7 ETM+image data in the Namyangju-city area were performed, and then this classified results were compared to land-use thematic data at the same area. In case of classified results by using muff-resolution image data, it is shown that linear-type features can be easily extracted. furthermore, it is expected that multi-resolution classified image can be effectively utilized to urban environment analysis, according to results of similar pattern by comparative study based on multi-buffered zone analysis or so-called distance analysis along main road features in the study area.

3D Path-Planning for Weighted-Regions by Weighted-Octree Method (가중 8진트리를 이용한 가중치 지역에 대한 최적경로설정)

  • 임상석;이창규;황주영;박규호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.440-442
    • /
    • 1999
  • 본 논문에서는 가중치 3차원 공간을 가중치 8진트리를 이용하여 나타낸다. 가중치 8진트리는 가중치 영역을 계층적으로 나타내고 용이하게 분해능을 조절할 수 있게 한다. 즉 높은 가중치를 갖는 공간은 세밀하게 분해하고 낮은 가중치를 갖는 공간은 성길하게 분해하여 최적의 경로설정을 바른 시간에 할 수 있도록 한다. 이러한 8진트리를 바탕으로 하여 최적 경로 설정하는 종합틀(Framework)을 제시하고 실험을 통하여 그 결과를 제시한다.

  • PDF