• Title/Summary/Keyword: 골 재생

Search Result 276, Processing Time 0.022 seconds

Effect of Enamel Matrix Derivative on Guided Bone Regeneration with Intramarrow Penetration (골수내천공을 동반한 골유도재생술시 법랑기질유도체의 효과)

  • Lee, Young-Jong;Park, Joon-Bong;Kwon, Young-Hyuk;Herr, Yeek;Cho, Kyoo-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.34 no.2
    • /
    • pp.393-410
    • /
    • 2004
  • The purpose of this study was to investigate effect of enamel matrix derivative on guided bone regeneration with intramarrow penetration in rabbits. Eight adult male rabbits (mean BW 2Kg) were used in this study. Intramarrow penetration defects were surgically created with round carbide bur(HP long #6) on calvaria of rabbits. Defects were assigned to the control group grafted with mixture of the same quantity of demineralized freeze-dried bone allograft and deproteinized bovine bone mineral. Then, guided bone regeneration was carried out using resorbable membrane and suture. Enamel matrix derivative applied to defects was assigned to the test group. And treated as same manners as the control group. At 1, 2, 3 and 8 weeks after the surgery, animals were sacrificed, specimens were obtained and stained with Hematoxylin-Eosin for light microscopic evaluation. The results of this study were as follows : 1. At 1, 2 and 3 weeks, no differences were observed between the control group and the test group in the aspect of bone formation around bone graft. 2. Proliferation of blood capillary was faster in the test group than in the control group. 3. Bone regeneration in intramarrow penetration was faster in the test group than in the control group. 4. At 8 weeks, new osteoid tissue formation around bone graft was more prominent in the test group than in the control group. From the above results, enamel matrix derivative might be considered as the osteopromotion material and effective in the guided bone regeneration with intramarrow penetration.

The Effects of Tetracycline-loaded Silk Fibroin Membrane on Guided Bone Regeneration in a Rabbit Calvarial Defect Model (가토 두개골 결손부 모델에서 테트라사이클린 함유 실크 파이브로인 차폐막의 골유도 재생 효과)

  • Lee, Sang-Woon;Park, Yong-Tae;Kim, Seong-Gon;Kweon, HaeYong;Jo, You-Young;Lee, Heui Sam
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.5
    • /
    • pp.293-298
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the bone regeneration ability of 1% tetracycline (TC)-loaded silk fibroin membrane (SFM), in a rabbit calvarial defect model. Methods: Twenty New Zealand white rabbits were used for this study. Bilateral round defects were made on the rabbit parietal bone, using trephine bur with an 8 mm diameter. TC-loaded SFM or SFM was covered on the right parietal bone defect, and the left parietal bone defects were uncovered for the control. The animals were humanely sacrificed at 4 or 8 weeks postoperatively. A micro-computerized tomography (${\mu}$-CT) of each specimen was taken for analysis of bone regeneration. Hematoxylin and Eosin stain were done to observe histological findings. Results: From the ${\mu}$-CT results, regenerated bone volume ($mm^3$) of 1% TC-loaded SFM, SFM, and control were $7.80{\pm}5.87$, $8.79{\pm}3.44$, and $10.61{\pm}5.3$ at 4 weeks postoperatively, respectively (P>0.05). Regenerated bone volume ($mm^3$) of 1% TC-loaded SFM, SFM, and control were $36.56{\pm}8.50$, $25.86{\pm}8.17$, and $19.09{\pm}5.07$ at 8 weeks postoperatively, respectively (P<0.05). Conclusion: The 1% TC-loaded SFM showed more bone regeneration than the SFM and the uncovered control, in guided bone regeneration.

Osteoblast differentiation of human bone marrow stromal cells (hBMSC) according to age for bone tissue engineering (조직공학 재생골을 위한 연구에서 사람 골수 기원 간엽줄기세포의 나이에 따른 조골세포 분화능에 관한 연구)

  • Song, Gin-Ah;Ryoo, Hyun-Mo;Choi, Jin-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.243-249
    • /
    • 2010
  • Tissue engineered bone (TEB) can replace an autogenous bone graft requiring an secondary operation site as well as avoid complications like inflammation or infection from xenogenic or synthetic bone graft. Adult mesenchymal stem cells (MSC) for TEB are considered to have various ranges of differentiation capacity or multipotency by the donor site and age. This study examined the effect of age on proliferation capacity, differentiation capacity and bone morphogenetic protein-2 (BMP-2) responsiveness of human bone marrow stromal cells (hBMSC) according to the age. In addition, to evaluate the effect on enhancement for osteoblast differentiation, the hBMSC were treated with Trichostatin A (TSA) and 5-Azacitidine (5-AZC) which was HDAC inhibitors and methyltransferase inhibitors respectively affecting chromatin remodeling temporarily and reversibly. The young and old group of hBMSC obtained from the iliac crest from total 9 healthy patients, showed similar proliferation capacity. Cell surface markers such as CD34, CD45, CD90 and CD105 showed uniform expression regardless of age. However, the young group showed more prominent transdifferentiation capacity with adipogenic differentiation. The osteoblast differentiation capacity or BMP responsiveness was low and similar between young and old group. TSA and 5-AZC showed potential for enhancing the BMP effect on osteoblast differentiation by increasing the expression level of osteogenic master gene, such as DLX5, ALP. More study will be needed to determine the positive effect of the reversible function of HDAC inhibitors or methyltransferase inhibitors on enhancing the low osteoblast differentiation capacity of hBMSC.

Guided bone regeneration using two types of non-resorbable barrier membranes (두 가지 유형의 비흡수성 차단막을 이용한 골유도재생술의 비교연구)

  • Lee, Ji-Young;Kim, Young-Kyun;Yun, Pil-Young;Oh, Ji-Su;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.4
    • /
    • pp.275-279
    • /
    • 2010
  • Introduction: Guided bone regeneration (GBR) is a common procedure for the treatment of bone defects and bone augmentation. The nonresorbable barriers are well-documented barriers for GBR because of their stability and malleability. However, few GBR studies have focused on the different types of non-resorbable barriers. Therefore, this study examined the clinical results of different non-resorbable barriers for GBR; expanded polytetrafluoroethylene (e-PTFE) (TR-Gore Tex, Flagstaff, AZ, USA), and high-density polytetrafluoroethylene (d-PTFE) (Cytoplast membrane, Oraltronics, Bremen, Germany). Materials and Methods: The analysis was performed on patients treated with GBR and implant placement from January 2007 to October 2007 in the department of the Seoul National University Bundang Hospital. The patients were divided into two groups based on the type of non-resorbable barrier used, and the amount of bone regeneration, marginal bone resorption after prosthetics, implant survival rate and surgical complication in both groups were evaluated. Results: The implants in both groups showed high survival rates, and the implant-supported prostheses functioned stably during the follow-up period. During the second surgery of the implant, all horizontal defects were filled with new bone, and there was no significant difference in the amount of vertical bone defect. Conclusion: In bone defect areas, GBR with non-resorbable barriers can produce favorable results with adequate postoperative management. There was no significant difference in bone regeneration between e-PTFE and d-PTFE.

THE EFFECT OF $TGF-{\beta}1$ ON THE REGENERATION OF BONE IN GUIDED BONE REGENERATION (탈회동결건조골에 혼합한 형질 변형 성장인자($TGF-{\beta}1$)가 골조직 재생에 미치는 영향)

  • Chung, Sung-Min;Lee, Man-Sup;Park, Joon-Bong
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.2
    • /
    • pp.357-371
    • /
    • 1995
  • The purpose of this study was to observe the effect of $TGF-{\beta}1$ on the regeneration of bone in guided bone regeneration. Four adult dogs aged 12 to 24 months were used in this study. Experimental bone defects were created surgically with surgical bur and chisel on the 3th. premolars. In experimental group, bone defect were grafted with DFDB and $TGF-{\beta}1$. In control groups, bone defects were grafted with only DFDB. At 1,2,3 and 4 weeks, dogs were serially sacrificed and specimens were prepared with Hematoxylin-Eosin stain and Goldner's stain for light microsopic evaluation. The results of this study were as follows: 1. The infiltration of inflammatory cells was prominent in control groups at 1, 2 and 3 weeks. 2. The lining of osteoblast was observed at 2 weeks in control group, but at 1 week in experimental group. 3. In both groups, osteoid was formed at 2 weeks. In control groups, osteoid was fromed on only bone surface. but in experimental groups, osteoid were formed on both bone & DFDB surfaces. 4. In only experimental groups, The fusion of new bone & DFDB was only observed at 3 weeks. and the fusion of new bone & DFDG was more prominent at 4 weeks. But in control groups, No fusion of new bone& DFDB was oberved at 3 and 4weeks. From the above result, the $TGF-{\beta}1$ was effective in bone formation and increased inductive effect of DFDB in guided bone regeneration technique. Inductive effect of DFDB was increased with $TGF-{\beta}1$.

  • PDF

A Comparison of the Appearance in Implant Success according to Membrane Type during GBR(Guided Bone Regeneration) (골유도 재생술식(GBR)시 차단막 종류에 따른 임플란트 결과 비교)

  • Lee, Sunmi;Kim, Jiyoung
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.2
    • /
    • pp.41-47
    • /
    • 2014
  • Purpose : The aim was to compare the implant success rate according to membrane type through a clinical case of patients, who used bio-resorbable membrane and non-resorbable membrane. Methods : A survey was conducted targeting patients with the use of bio-resorbable membrane and non-resorbable membrane who visited H dental clinic in Busan for implant surgery and bone graft for 1 year from May 2010 to May 2011. A chart was made and surveyed for 100 people with non-resorbable membrane and for 75 people with bio-resorbable membrane. Results were compared. Results : 1. As for the measurement value of Periotest M${(R)}$, the value of -8~0 was measured with 92% in case of surgery by using non-resorbable membrane. The value of +1~+9 was measured with 8.0%. In case of surgery by using bio-resorbable membrane, Peiotest M(R) was measured with 78.7% as for the value of -8~0 and 16(21.3%) as for the value of +1~+9. In light of this, a case of using non-resorbable membrane was indicated to be higher(p=0.021) in success rate than a case of using bio-resorbable membrane. 2. As a result of periodontal conditions, namely, bleeding(p=0.914), swelling(p=0.500), inflammation(p=0.074), pain(p=0.571), and itch appearance(p=0.475) according to membrane type, all were insignificant. Conclusions : A case of using non-resorbable membrane is considered to be likely to be more effective than using bio-resorbable membrane during GBR(Guided Bone Regeneration) with the use of membrane in implant surgery.

Fabrication and Evaluation of Hybrid Scaffold by Nano-Micro Precision Deposition System (나노-마이크로 정밀 분사 시스템을 이용한 하이브리드 인공지지체의 제작 및 평가)

  • Ha, Seong-Woo;Kim, Jong Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.8
    • /
    • pp.875-880
    • /
    • 2014
  • Recently, three-dimensional scaffolds and nanofibers are being developed for bone tissue regeneration. In this study, we fabricated a hybrid scaffold using a nano-micro precision deposition system. The fabrication process involved the application of the solid freeform fabrication (SFF) technology and electrospinning. The hybrid scaffolds were combined using micro scaffolds and nanofibers. The nanofibers were deposited on each layer of the micro scaffolding using the electrospinning process. The micro scaffolds were fabricated using the SFF technology at a temperature of $100^{\circ}C$, pressure of 650 kPa, and scan velocity of 250 mm/s. Nanofiber fabrication was conducted by means of electrospinning using the flow rate, solution concentration, distance from the tip to the collector (TCD), and voltage. The nanofibers were fabricated using a flow rate of 0.1 ml/min, voltage of 5 kV, TCD of 1 mm, and 10 wt% of solution concentration. MG-63 cells were seeded into the hybrid scaffold for the purpose of its evaluation.

HISTOLOGICAL COMPARATIVE STUDY OF GUIDED BONE REGENERATION WITH GORE-TEX-TXMEMBRANE AND COLLACOTE® (Gore-TexTMmembrane과 COLLACOTE®를 이용한 골유도 재생술의 조직학적 비교 연구)

  • Kim, Tae-Kyu;Jang, Chang-Dug;Kim, Cheol-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.19 no.1
    • /
    • pp.15-24
    • /
    • 1997
  • The principle of guided tissue regeneration (GTR), as applied to bone healing, is based on the prevention of connective tissue from entering the bony defect during the healing phase. This allows the slower bone producing cells to migrate into and reproduce bone within the defect. GTR has demonstrated a level of success in regenerating bone defect. Several types of membrane barrier have been utilized to apply this principle in bone regeneration. The purpose of this study was to evaluate whether improved bone regeneration can be achieved with different membrane barriers ($Gore-Tex^{TM}$membrane, $COLLACOTE^{(R)}$). In the 10 NewZealand white rabbits, full-thickness bone defects on three sites of each rabbit calvaria were made. Experimental group 1 was covered with $COLLACOTE^{(R)}$, and group 2 was covered with $Gore-Tex^{TM}$membrane. Macroscopic, microscopic examinations were made serially on 1, 2, 3, 6, 12 weeks after operation. The results were as follows : 1. Macroscopically, both of experimental group 1, 2 were filled with bone-like mass but the defects of experimental group 1 disclosed markedly thinner than the original bone. 2. Microscopically, the defect of experimental group 1, 2 was filled with bony trabeculae without infection and adverse reaction. But multinucleated giant cell infiltration around $COLLACOTE^{(R)}$ was seen till 6th week. 3. Resorption of $COLLACOTE^{(R)}$ started from 3rd week and it was completely resorped on the 12th week.

  • PDF

EFFECT OF TEFLON MEMBRANE AND NYLON MEMBRANE ON GUIDED BONE REGENERATON IN RABBIT TIBIA (가토 경골 골결손부에서 Nylon Membrane과 Teflon Membrane의 골유도 재생 효과)

  • Kim, Kwan-Shik;Cho, Byoung-Ouck;Lee, Young-Chan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.26 no.2
    • /
    • pp.146-153
    • /
    • 2000
  • The purpose of present study is comparing the effect of Teflon Membrane and Nylon Membrane on bone regeneration in rabbit tibia. The 6 defects of $8{\times}8{\times}5mm$ size were drilled with dental handpiece in rabbit tibia, which on left side as an order of Control group(no coverage), Group 1(Nylon $5{\mu}m$ size), Group 3(Nylon $10{\mu}m$ size), and on right side Control group, Group 2($5{\mu}m$ Teflon), Group 4($10{\mu}m$ Teflon). Animals were killed at 7, 10, 14, 42 days to make specimens and observed the difference of healing potentials with light microscopy. The results were as follows ; 1. New bone formation has taken place at 14 days in Guided Bone Regeneration (GBR) group comparing to the Control group of massive inflammatory status. 2. Larger pore membrane allows more favorable healing potentials. Bone formation started earlier in larger membrane pore groups than smaller groups, until 14 days. 3. Bone forming potentials of Teflon membrane group was higher than Nylon membrane groups, Control group has the lowest bone forming potentials. 4. New bone formation was almost ended in 42 days, and there was no difference of bone formation between Nylon and Teflon membrane group of different size. There was no difference of bone formation at final stage(42 days) between Nylon membrane and Teflon membrane of same pore size. So nylon membrane may be clinically usable in guided bone regeneration case with further studies.

  • PDF

Experimental study on the effect of direct microcurrent to periodontal regeneration in class III furcation defects (3급 치근분지부 골결손에서 미세전류자극이 치주조직의 재생에 미치는 영향에 관한 실험적 연구)

  • Kim, Young-Jun;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.4
    • /
    • pp.845-866
    • /
    • 1997
  • Several experimental studies showed that the application of small amounts of electric current to bone stimulated osteogenesis at the site of the cathode and suggests that the application of electrical currents to periodontal defects could promote bone and cementum formation. The purpose of this study was to determine the effect of direct microcurrent to the periodontal regeneration of class III furcation defects in dogs. Class III furcation defects were surgically created on the third and the fourth premolars bilaterally in the mandibles of nine mongrel dogs. Experimental periodontitis were induced by placing small cotton pellets into the created defects for 3 weeks. The experimental sites were divided into three groups according to the treatment modalities: Group I-surgical debridement only; Group II-allogenic demineralized freeze dried bone grafting; Group III-allogenic demineralized freeze dried bone grafting and electrical stimulation. For fluorescence microscopic evaluation, calcein, oxytetracycline HCI and alizarin red were injected 2, 4 and 8 weeksfS days prior to sacrifice) after surgery. The animals were sacrificed in the 1st, 2nd, 4th and 8th week after periodontal surgery and the decalcified and undecalcified specimens were prepared for histological and histometrical examination. After the first and the second weeks, gingival recession was more severe in group I than groups II and III. After the fourth and the eighth weeks, there was no difference in the width of junctional epithelium and connective tissue attachment among the three groups, but the width of connective tissue attachment increased in group II at the eighth week, compared to the fourth week. The amount of bone repair in new attachment was significantly greater in group III, compared to groups I and II. New attachment formation was significantly greater in group III, compared to groups I and group II. These results suggest that electrical stimulation using microcurrent generator could be a useful tool for periodontal regenerative therapy in class III furcation defect.

  • PDF