• Title/Summary/Keyword: 골 용해

Search Result 457, Processing Time 0.032 seconds

Prosthetic rehabilitation of a fully edentulous patient after maxillectomy: A case report (상악골 절제술을 시행한 완전 무치악 환자에서 폐쇄장치를 이용한 보철 수복 증례)

  • Yoon, Jung-Hoon;Kim, Jong-Jin;Baik, Jin;Cha, Hyun-Suk;Lee, Joo-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.88-93
    • /
    • 2017
  • Most patients with acquired maxillary surgical defects have difficulties such as functional impairments of mastication, speech, and deglutition as well as various degrees of facial deformity. The purpose of a prosthetic approach is to restore function and appearance with an obturator as normal as possible. This goal can be achieved when there is thoughful preoperative communication between a prosthodontist and a surgeon regarding a rehabilitation. In this case report, prosthetic rehabilitation was planned before the surgery for the patient diagnosed with squamous cell carcinoma in the right maxillary sinus with careful oral examination. Four months after maxillectomy, a definitive obturator was fabricated following the surgical and interim obturation phase. The objective of this case report is to describe the satisfactory results of the patient with improved rehabilitation of mastication, speech, deglutition, and appearance.

Prosthetic rehabilitation using an obturator in a fully edentulous patient who had partial maxillectomy (상악골 부분 절제술을 받은 무치악 환자에서의 구강폐쇄장치 수복)

  • Chung, Yoo-Jin;Kim, Jong-Jin;Baik, Jin;Cha, Hyun-Suk;Lee, Joo-Hee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.4
    • /
    • pp.331-337
    • /
    • 2018
  • Prosthetic rehabilitation of an edentulous patient who has a maxillary defect is difficult to achieve for many clinicians. The maxillary defect causes leakage of air during pronunciation and compromises denture stability, support and retention by reducing denture-bearing area and breaking peripheral seal. In these patients, the sizes and shapes of defects are very important factors which attribute to prognosis of maxillary obturators. This case report shows the prosthetic rehabilitation of the patient who had maxillectomy on the right maxillary sinus because of squamous cell carcinoma. The patient had a stepwise treatment protocol which started with pre-operative dental examination and followed by surgical, interim and definitive obturation phase. In this case, an acceptable level of retention could be obtained due to well-defined static defects and the preserved premaxillae and the patient was satisfied with the result of the treatment in the aspect of function and esthetics.

Effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized implants coated with heparin for improving alveolar ridge augmentation in beagle dogs: Radiographic observations (양극산화 임플란트 표면에 적용된 헤파린과 골형성단백질(rhBMP-2)이 치조골 증대에 미치는 효과: 방사선학적 평가)

  • Lee, So-Hyoun;Jo, Jae-Young;Yun, Mi-Jung;Jeon, Young-Chan;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.307-314
    • /
    • 2013
  • Purpose: The aim of this study was to evaluate the effect of immobilization of the recombinant human bone morphogenetic protein 2 (rhBMP-2) on anodized titaum implants coated with heparin to enhance the vertical alveolar ridge augmentation in the supraalveolar peri-implant defect region. Materials and methods: 18 pure titanium implants (7.0 mm in length, 3.5 mm in diameter) were manufactured for this study. All implants were anodized and designed insertion reference line marked with laser at the apical 2.5 mm from the fixture platform. Implantation of 6 noncoated anodized implants (Control group), 6 anodized implants physically adsorbed with rhBMP-2 by dip and dry method (BMP group) and 6 anodized implants chemically immobilized 3,4-dihydroxyphenylalanine (DOPA)-heparin/ rhBMP-2 (Hep-BMP group) was performed in the both mandibular of three male adult beagle dogs using split-mouth design. Radiologic examinations were performed immediately after implant placement and 4 and 8 weeks after implant placement. The amount of mesio-distal bone augmentation was evaluated by measuring the vertical distance from the platform to the marginal bone. Statistical analysis was performed using one-way analysis of variance (SPSS version 18.0) and multiple comparison analysis of The Kruskal-Wallis test and the Mann-Whitney U test. Statistical significance was established at the 5% significant level. Results: At the 4 weeks vertical alveolar ridge augmentation of Control group, BMP group and Hep-BMP group is $0.09{\pm}0.22mm$, $1.02{\pm}0.72mm$, and $1.29{\pm}0.51mm$, At the 8 weeks $0.11{\pm}1.26mm$, $1.11{\pm}0.58mm$, $1.59{\pm}0.79mm$ according to radiographic observations. The two experimental groups showed a significantly increasing in vertical bone height compared with the control group (P<.05). However, there is no significant difference between the BMP group and Hep-BMP group (P>.05). Conclusion: The rhBMP-2 coated implants were enhanced the vertical bone growth in the supraalveolar peri-implant defect area. However, there is no significant difference between chemically and physically coating method.

The Effect of Sympathectomy on Bone: -Evaluation with Quantitative Bone Scintigraphy- (흰쥐에서 교감신경절제술이 골에 미치는 영향 : -정량적 골스캔을 이용한 평가-)

  • Kim, Hak-Hee;Yang, Woo-Jin;Lee, Seong-Yong;Chung, Soo-Kyo;Park, Jang-Sang;Yim, Jung-Ik;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.1
    • /
    • pp.85-88
    • /
    • 1994
  • 근래 골조직에 있어서 자율신경의 기능에 대하여 많은 연구가 이루어지고 있으며, 골내의 자율신경의 해부학적 분포는 많이 알려져 있다. 그러나 임상적으로 반사적 교감신경 이상이나 레이노드 현상등과 같은 교감신경의 기능이상증에서나, 버거씨병 등의 치료 목적으로 시행되고 있는 교감신경 절제술 후, 자율신경기능의 변화가 사지골의 혈류나 골대사에 미치는 영향에 대하여는 아직도 논란의 여지가 있다. 저자들은 교감신경절제술 후 시간 경과에 따른 골에 미치는 영향을 알아보기 위하여 흰쥐에서 골대사와 혈류상태를 비교적 충실히 반영하는 정량적 골스캔을 시행하였다. 체중 $300{\sim}400g$의 수컷 흰쥐 10마리에서 복강을 통한 편측 요추부 교감신경절제술을 시행하였고, 수술 전과 후 1일, 3일, 1주, 2주, 3주, 4주에 양측 하지에서 각각 골스캔을 시행하고 교감신경 절제측 하지와 정상 하지에 대칭적으로 관심구역을 정하여 양측의 골스캔상 섭취계수를 비교하였다. 측정부위는 각 하지의 대퇴골간, 경골간 및 중족골로 하였다. 교감신경 절제술을 시행한 하지에서는 골스캔 소견상 수술 후 1일 또는 3일부터 동위원소 집적이 유의하게 증가되었으며 원위부로 갈수록 더욱 증가되었다. 그러나 3주 이후에는 정상측 수준으로 환원되었다. 교감신경절제술 후 골스캔상 동위원소집적이 증가되는 것은 골자체의 혈류가 증가되기 때문이며 이차적으로 골의 흡수를 유발하여 골밀도가 감소하는 것으로 생각되는데 이러한 변화는 시술 후 1일 째부터 관찰되어 사지골이 교감신경 절제에 매우 민감하게 반응하는 것을 알 수 있었다.9m}Tc$-MAA를 이용한 간 동맥 혈류 검사는 간암에서 색전술의 효과를 정확히 평가할 수 있는 유용한 검사법으로 이용될 수 있으리라 생각한다. 활성화 과정을 알아볼 수 있었으며 위상영상히스토그램을 통하여 이를 정량화하여 심실내 전기적 활성의 비동시성 여부를 추적관찰 할 수 있는 비관혈적검사임을 확인하였다.며, 3. $^{99m}Tc$으로 표지된 avidin과 streptavidin은 먼저 간으로 흡수된 후 대사된 다음 신장으로 배설된다는 사실을 알았다.damole에 의한 부작용은 흉통, 두통, 복통 등의 순이었고 전예에서 호전되었으며 생명에 위험을 초래할 수 있는 정도의 심장마비나 심부정맥은 한 예에서도 없었다. 결론적으로 dipyridamole은 약물부하 심근 SPECT 검사에 안전하게 사용할 수 있는 약물로 사료된다. 미소핵 빈도수가 증가하는 경향을 보였으나, 각 군간에 통계학적으로 유의한 차이는 없었다(p>0.05). 결론 : 임상적으로 치료를 중단하게 되는 1000mCi/60 Kg(16.67 mCi/Kg)를 투여한 군에서도 생쥐 골수내 미소핵이 발현되지 않는 것으로 보아, 방사성옥소는 비교적 안심하고 치료에 사용할 수 있는 제제로 사료되었다.반드시 비례하지만은 않아서 시간경과에 따른 추후 검사가 필요하리라 생각된다. 또한 방광요관역류가 있는 환아에서 DMSA 섭취율로 신기능을 평가할 때, 특히 영유아에서 연령에 따른 고려가 있어야 할 것으로 보인다.었다. 4) $^{99m}Tc-DISIDA$ hepatobiliary scintigram 음성율을

  • PDF

Study of heat transfer to the implant-bone interface induced by grinding of occlusal surface of implant gold prosthesis (금 합금 보철물의 교합면 삭제로 인한 임플란트-골 계면으로의 열전달에 관한 연구)

  • Jo, Jae-Young;Kang, Sun-Nyo;Jeong, Chang-Mo;Yun, Mi-Jung;Huh, Jung-Bo;Jeon, Young-Chan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: The purpose of this study was to analyze temperature change along the implant-bone interface induced by grinding the occlusal surface of implant gold prosthesis and to compare the temperature generated by grinding of prosthesis with different cooling methods. Materials and methods: The experimental gold prostheses were fabricated with dental gold alloy and castable abutment. The prostheses had 3 cylindrical protrusions on the occlusal surface with 1mm in height. Temperature was measured using 16 thermocouple wires attached to the implant fixture surface and the fixture was embedded in an acrylic resin block inside the $37^{\circ}C$ water bath. Cylinders were grinded for a period of 30 second with a low-speed handpiece with green stone point. One cylindrical protrusion was grinded without cooling, the second one was grinded with air blow, and the third one was grinded with water-spray. Results: The mean maximum temperature was measured more than $47^{\circ}C$ of the implant and the maximum temperature was measured at the cervical portion of the implant in the group without cooling. There was statistically significant difference between the group without cooling and the groups with cooling (P<.05). However, there was no significant difference at all portion of implant in the groups with cooling (P>.05). Conclusion: The results of this study support that the grinding of implant gold prosthesis without cooling may damage the peri-implant tissue. The continuous use of air blow and water-spray adjacent to prosthesis during the grinding of implant gold prosthesis may prove to be beneficial for cooling of the implant.

New Technique for the Reconstruction of Both Anteromedial & Posterolateral Bundles of ACL (전방십자인대의 전내측 다발 및 후외측 다발을 각각 재건하는 새로운 수술 수기)

  • Ha Chul-Won;Awe Soo-Ik
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.2
    • /
    • pp.195-199
    • /
    • 2002
  • This article is to report a new technique for reconstruction of the anteromedial and posterolateral bundles of anterior cruciate ligament by separate tensioning and fixation of the each bundle. Method : Tibial and femoral tunnels were made with conventional technique of anterior cruciate ligament reconstruction. Tibial tunnel was enlarged $5\~7$ mm in anterior-posterior direction to make oval it in cross section. When preparing the Achilles tendon allograft, bone plug portion was trimmed as the conventional technique. The tendinous portion was trimmed as two separate bundles by dividing the tendinous portion longitudinally, so the graft is shaped like 'Y'. The bone plug portion of allograft was inserted into the femoral tunnel and fixed with absorbable cross pins. Two ligamentous portionss of the distal part of the grafts were tensioned separately at the external orifice. Anteromedial bundle was fastened under maximum tension with the knee flexed 90 degrees by post-tie method. The posterolateral bundle was fixed by the same technique with the knee in full extension. Then, an absorbable interference screw was inserted between the two bundles upto the upper end of the tibial tunnel, to get more initial rigidity of the reconstructed graft as well as to locate the two bundles in more anatomic position.

  • PDF

Bone-implant contact and mobility of surface-fronted orthodontic micro-implants in dogs (성견에서 표면처리된 교정용 마미크로 임플랜트의 골 접촉률 및 동요도)

  • Park, Seung-Hyun;Kim, Seong-Hun;Ryu, Jun-Ha;Kang, Yoon-Goo;Chung, Kyu-Rhim;Kook, Yoon-Ah
    • The korean journal of orthodontics
    • /
    • v.38 no.6
    • /
    • pp.416-426
    • /
    • 2008
  • The purpose of this study was to evaluate the mobility and ratio of the bone-implant contact (BIC) of a sandblasted, large grit and acid-etched (SLA) orthodontic micro-implant. Methods: Ninety-six micro-implants (48 SLA and 48 machined) were implanted in the upper and lower buccal alveolar bone, and palatal bone of four beagle dogs. Two weeks after surgery, orthodontic force (150-200 g) was applied. Two beagles were sacrificed at 4-weeks and the other two at 12-weeks. Histomorphometric comparisons were made between the SLA experimental group and the machined micro-implant as a control group to determine the ratio of contact between the bone and implant. Micro-implant mobility was also evaluated using $Periotest^{(R)}$. Results: Periotest values showed no statistically significant difference in the upper alveolar and palatal bone between groups except for the lower buccal area. BIC in the upper buccal area showed no significant difference between groups both at 4-weeks and 12-weeks. However, both the groups showed a significant difference in BIC ratio in the rest of the experimental areas between 4 weeks and 12 weeks. The experimental group showed active bone remodeling around the bone-implant interface compared to the control group. Conclusions: There were significant differences in the BIC and the Periotest values between the surface-treated and machined micro-implants according to bone quality in the early stage.

Treatment of Giant Cell Tumor Around Knee - by Intralesional Excision Using High Speed Burr and Methylmethacrylate - (슬관절 주변에 발생한 거대세포종의 치료 - 고속 바(High-Speed Burr)와 골 시멘트를 이용한 병소 내 절제술 -)

  • Park, Jong-Hoon;Lee, Soo-Yong;Jeon, Dae-Geun;Cho, Wan-Hyung;Song, Won-Seok;Kim, Jin-Wook;Koh, Han-Sang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.160-167
    • /
    • 2005
  • Purpose : Distal femur and proximal tibia are the common sites affected by giant cell tumor of bone. There are a variety of treatment modality including wide excision and intralesional curettage. We evaluated the local recurrence rates and the post-operative functional scores of giant cell tumors around knee joint and investigated the identification of possible prognostic factors for recurrence. Materials and Methods: We reviewed 41 patients pathologically confirmed as giant cell tumors around knee joint that have undergone intralesional curettage using high-speed burr and methylmethacrylate. We evaluated the recurrence rate and post-surgical functional score and possible prognostic factors for recurrence, such as, gender, age, tumor location, size, subchondral invasion, intra-articular invasion and the Campanacci Grades. Mean follow up period was 50 (12-122) months. Results: The recurrence rate was 17% and mean recurrence onset was 10 months postoperatively. According to Musculoskeletal Tumor Society (MSTS) functional evaluation system, the average score was 27.8(93%) and 78% had excellent function. According to our study, suspected prognostic factors revealed not significant for recurrence. Conclusion: We found no significant recurrence related factors. Intralesional excision with high-sped burring and PMMA provides a low recurrence rate, similar to others in the literature, and good functional scores.

  • PDF

3-D FEA of three different single tooth abutments : Cement-retained Vs Screw-retained (3종의 단일치아 수복용 지대주의 삼차원 유한요소법적연구 : 시멘트 유지헝 대 나사 유지형)

  • Lee, Jung-Min;Kim, Yung-Soo;Kim, Chang-Whe;Kim, Yong-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.2
    • /
    • pp.269-288
    • /
    • 1999
  • 현재 골 유착성 임플랜트는 안전하고 유용한 보철 수복 분야의 하나로 자리잡아 가고있다. 과거 완전 무치악 환자에게 있어서 저작 기능의 회복이란 면에 중점을 두었던 경향에서 현재 골유착 임플랜트의 높은 성공률에 의해 부문 무치악, 단일치 수복에 까지 다양하게 사용되고 있다. 특히 심미성과 인접치의 손상을 가하지 않는다는 면에서 단일치 수복에서 골유착 임플랜트 치료에 관심이 모아지고 있다. 단일치 수복에 있어서 심미성이 중요한 문제로 대두되면서 이런 수복에 사용될 수 있는 다양한 계통의 임플랜트들이 개발되어 사용되고 있다. 이중 가장 기본적인 Branemark 계통의 CeraOne 지대주, 최근에 개발된 전부도재 지대주인 CerAdapt 전부주조 지대주인 UCLA 계통등은 높은 성공률을 보이며 많이 사용되고 있다. 임상가들에 의해 나사유지형 보철물이 착탈성이란 관점에서 선호되고 있다. 시멘트유지형 보철물에서는 나사공이 없는 온전한 교합면을 유지한다는 면과 교합력을 받는 면적에 있어서 더 넓은 면을 가진다는 점등 더 많은 장점을 가진다고 주장하는 사람도 있다. 임상가들의 기호에 의해 선택되어지는 나사 유지형과 시멘트 유지형에 있어서 교합력이 야기하는 하중하에서 각각의 응력 분포를 분석할 필요성이 요구되었다. 이 연구는 단일치 수복에 사용되는 CeraOne, CerAdapt UCLA 계통에서 각각의 나사 유지형과 시멘트유지형에서의 응력분포를 삼차원 유한요소법으로 분석하고 상부 구조물에 가해지는 수직하중, 수평 하중, 경사 하중에 의해 야기되는 응력을 비교 분석한 것이다. 본 연구의 연구 결과는 다음과 같다. 1. CeraOne, CerAdapt, UCLA 지대주 모두 시멘트유지형보다 나사유지형에서 응력집중이 컸다. 2. CeraOne 시멘트유지형인 1번 모델에서 응력분산이 유리하였고, UCLA 나사 유지형인 6번 모델에서 가장 불리하였다. 3. 모든 모델에서 고정체 경부에서 가장 큰 응력 집중이 있었고 이것은 UCLA 지대주에서 가장 컸다. 4. 상부 구조물에서 주된 응력의 집중은 교합면에서 일어났다. 5. 골은 상부 피질골, 즉 고정체경부와 만나는 부위에서 가장 큰 응력의 집중이 일어났으며 수평, 경사 하중시 응력집중 양상은 힘을 가한 쪽의 반대쪽 고정체 경부에 응력이 집중되는 양상을 보였다. 6. 전체 모델과 골, 고정체 모두에서 수평 하중과 경사 하중시 보다는 수직 하중시 더 적은 응력값을 보였다.

  • PDF

Emergency preoperative angioembolization without computed tomography to treat unstable pelvic fractures with bowel perforation (장 천공을 동반한 혈역학적으로 불안정한 골반골 골절에서 전산화 단층촬영 전 시행한 혈관색전술의 지혈효과: 증례보고)

  • Park, Chan-Yong;Kang, Wu-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.417-422
    • /
    • 2019
  • Hemodynamically unstable pelvic fractures show a remarkably high mortality rate of 40% to 60%. However, their standard of care remains controversial. We report here a case of a 78-year-old woman who was admitted to the Emergency Department with pelvic pain following a fall. Based on pelvic radiography, she was diagnosed with an unstable pelvic fracture. Her blood pressure was 60/40 mmHg, and owing to her unstable vital signs, emergency angiography was performed without computed tomography (CT). Both internal iliac arteries were embolized without sub-branch selection for prompt control of pelvic bleeding. Following embolization, her vital signs were stabilized. Subsequent CT revealed free intra-abdominal air, suggesting bowel perforation had occurred and necessitating emergency laparotomy. An approximately 1 cm-sized free perforation of the small intestine was identified intraoperatively, and primary closure was performed. A retroperitoneal hematoma identified intraoperatively was not explored further because it was a non-expanding and non-pulsatile mass. The patient was admitted to the Intensive Care Unit and transferred to the general ward on postoperative day 3. In this case, the hemodynamically stable pelvic fracture with bowel perforation was successfully and safely treated by prompt angioembolization without conducting CT.