Change of Morphologic Pelvis and Deviation According to Gender, Age -Radiological Pelvimetry- (성별과 나이에 따른 골반 형태 변화와 골반 변위 -방사선영상을 이용한 골반 계측-)

  • Kang, Yeong-Han;Kim, Seon-Chil
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.91-96
    • /
    • 2011
  • The purpose of this study was to analyze the change of morphologic pelvis according to age and gender. Pelvis AP(anterior-posterior) projection were taken from 382 individuals (men: 194, women: 188) at the age of twenty and older. We measured four values of pelvis using CR (computed radiological system) including maximum pelvic breadth (MPB), sacral breadth (SB), transverse diameter of pelvic inlet (TD), and distance between femoral heads (DFH). Average (t-test, ANOVA) and Pearson correlation were calculated for comparison. While there was no significant difference of gender in case of MPB, significant differences were observed in SB (men 97.76 mm, women 102.00 mm), TD (men 138.0 mm, women 149.79 mm), and DFH (men 141.94 mm, women 150.39 mm). The DFH values were negatively correlated with the age (men r=-0.280, women r=-0.207). The morphological changes of pelvis were measured high in the men of 50's and in the women of 60's and 70's. The SB, TD and DFH were greater in the women than in the man. As the ages get higher, the deviation of pelvis were gradually increased, which indicates that the morphological changes of pelvis with respect to the age reflects an aging process.

Pelvic Measurement Indicators to Produce the Gonad Protection of Female Infants (유아기 여아의 생식선 차폐체 제작을 위한 골반 지표 계측)

  • Kwak, Jong-hyeok;Park, Chan-hyeok;Moon, deog-hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.101-107
    • /
    • 2016
  • It was performed in this study to provide basic information on production of accurate gonadal shield by measuring pelvic indicators of TDP SD ISP IAD 1CDP and 2CDP. when pelvis ap and hip ap examination was taken, there is no exact position of the reference point of the shield and anatomically more difficult to shield gonad in the case of female infants than male. Results analyzed by height in 70~80 and 110~120 were approximately 30mm 13mm 19mm 20mm 2mm and 7mm difference in TDP SD ISP IAD 1CDP and 2CDP respectively. This value was statistically significant (P<0.05). Results analyzed by age of 2~3 and 6~7 were different on SD ISP IAD and 2CDP by 17mm 10mm 12mm 16mm respectively. it was also statistically significant. However 1CDP was not statistically significant(P>0.05). the difference was nearly about 1mm. Analysis of results by weight of less than 10 and more than 20 showed difference on TDP SD ISP IAD 1CDP and 2CDP by 28mm 14mm 11mm 20mm 3mm and 8mm. it was statistically significant (P<0.05). From the above results, female infants pelvic indicator measurement can be used as reference value for shielding production and especially IAD can present a reference point on the shielding position. Pelvis indicators of female infant has a close correlation. In addition, as it is showen in the statistical difference analysis to have an accurate ovarian shield, gonad shield would be produced and used by height, age and weight.

Clinical and Roentgen Pelvimetry;A Correlation and Efficacy (X선골반계측;임상적 가치와 유효성여부에 관하여)

  • Lee, S.H.;Park, T.K.;Kwak, H.M.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.8 no.2
    • /
    • pp.35-43
    • /
    • 1981
  • In order to evaluate the clinical utilization and efficacy of X-ray pelvimeter, a study of selective information from 292 cases, who had clinical and X-ray pelvimetry, among 7346 single term deliveries in the years 1975 and 1978 was undertaken in Yonsei University Medical Center. The results revealed that there were no significant statistical difference between X-ray and clinical pelvimetry groups in terms of the outcome of labor and in regard to determining the pelvic size (p > 0.05). Most X-ray examination which caused significant fetal exposure were pelvimetries.

  • PDF

A Study on the Effectiveness of the Manufacture of Compensator and Setup Position for Total Body Irradiation Using Computed Tomography-simulator's Images (전산화 단층 모의치료기(Computed Tomography Simulator)의 영상을 이용한 TBI(Total Body Irradiation) 자세 잡이 및 보상체 제작의 유용성에 관한 고찰)

  • Lee Woo-Suk;Park Seong-Ho;Yun In-Ha;Back Geum-Mun;Kim Jeong-Man;Kim Dae-Sup
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.147-153
    • /
    • 2005
  • Purpose : We should use a computed tomography-simulator for the body measure and compensator manufacture process was practiced with TBI's positioning in process and to estimate the availability.,Materials and Methods : Patient took position that lied down. and got picture through computed tomography-simulator. This picture transmitted to Somavision and measured about body measure point on the picture. Measurement was done with skin, and used the image to use measure the image about lungs. We decided thickness of compensator through value that was measured by the image. Also, We decided and confirmed position of compensator through image. Finally, We measured dosage with TLD in the treatment department.,Results : About thickness at body measure point. we could find difference of $1{\sim}2$ cm relationship general measure and image measure. General measure and image measure of body length was seen difference of $3{\sim}4$ cm. Also, we could paint first drawing of compensator through the image. The value of dose measurement used TLD on head, neck, axilla, chest(lungs inclusion), knee region were measured by $92{\sim}98%$ and abdomen, pelvis, inquinal region, feet region were measured by $102{\sim}109%$.,Conclusion : It was useful for TBI's positioning to use an image of computed tomography-simulator in the process. There was not that is difference of body thickness measure point, but measure about length was achieved definitely. Like this, manufacture of various compensator that consider body density if use image is available. Positioning of compensator could be done exactly. and produce easily without shape of compensator is courted Positioning in the treatment department could shortened overall $15\{sim}20$ minute time. and reduce compensator manufacture time about 15 minutes.

  • PDF

A Study on the Additional Radiation Exposure Dose of kV X-ray Based Image Guided Radiotherapy (kV X선 기반 영상유도방사선치료의 추가 피폭선량에 관한 연구)

  • Gha-Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1157-1164
    • /
    • 2023
  • This study measures the additional dose for each treatment area using kV X-ray based OBI (On-Board Imager) and CBCT (Cone-Beam CT), which have excellent spatial resolution and contrast, and evaluates the adequacy and stability of radiation management aspects of IGRT. The subjects of the experiment were examined with OBI and CBCT attached to a linear accelerator (Clinac IX), and ring-shaped Halcyon CBCT under imaging conditions for each treatment area, and the dose at the center was measured using an ion chamber. OBI single fraction dose was measured as 0.77 mGy in the head area, 3.04 mGy in the chest area, and 7.19 mGy in the pelvic area. The absorbed doses from the two devices, Clinac IX CBCT and Halcyon CBCT, were measured to be similar in the pelvic area, at 70.04 mGy and 70.45 mGy. and in chest CBCT, the Clinac IX absorbed dose (70.05 mGy) was higher than the Halcyon absorbed dose (21.01 mGy). The absorbed dose to the head area was also higher than that of Clinac IX (9.08 mGy) and Halcyon (5.44 mGy). In kV X-ray-based IGRT, additional radiation exposure due to photoelectric absorption may affect the overall volume of the treatment area, and caution is required.

Implementation of the Posture Stability Monitoring System using Balance Ability Method (균형능력 측정 기법을 이용한 자세안정도 모니터링 시스템 구현)

  • Cha, Sang-Hoon;Choi, Su-Bin;Park, Eun-Ji;Park, Jun-mo;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.537-538
    • /
    • 2016
  • Recently, modern people a lot of frequency of work and seat life by academic is increased, addictive spine for the wrong attitude and the wrong habits are many pelvic disease occurrence. Therefore, in order to induce continuous correct posture to prevent this, the system that can be induced to determine the posture information based on the seating information is requested. In this paper, when the development and inappropriate attitude of the device that is capable of tracking measurement in order to evaluate the attitude stability is detected, let your users know, to correct their attitude through the real-time monitoring It was implemented of categorize to help application.

  • PDF

Two Measurement Considerations for Counting of Background Radioactivity using the Thigh during Thyroid Uptake Rate Test (갑상샘 섭취율 검사 시 대퇴부를 이용한 배후방사능 계측을 위한 2가지 측정 고찰)

  • Do, Yongho;Cho, Youngkwon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.533-538
    • /
    • 2021
  • 99mTcO4- is used to measure thyroid uptake. When measuring background radioactivity of the thigh, the distance between the detector and the thigh was 20 cm at a position 10 cm above the knee from the knee to the pelvis. At 25 cm, many hospitals are measuring at different distances. The purpose of this study was to study the difference in effectiveness in obtaining the thyroid uptake rate by quantitatively analyzing the uptake rate measurement at two distances. As a result, the average thyroid uptake rate measured at 20 cm in the thigh of 50 patients was 3.532±4.312%, and the average thyroid uptake rate measured at 25 cm was 3.680±4.304%. As a result of the thyroid uptake rate test result, the femoral background radioactivity value measured at a distance of 20 cm was relatively higher than the background radioactivity value measured at a distance of 25 cm, and as a result, the thyroid uptake rate was 0.148% lower.

Histomorphometric study of machined titanium implants and calcium phosphate coated titanium implants (Machined 티타늄 임플란트와 calcium phosphate coated 티타늄 임플란트의 조직형태계측학적 연구)

  • Kang, Hyun-Joo;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The objective of this study was to investigate the effects of calcium phosphate coated titanium implant surface on bone response and implant stability at early stage of healing period of 3 weeks and later healing period of 6 weeks. Material and methods: A total of 24 machined, screw-shaped implants (Dentium Co., Ltd., Seoul, Korea) which dimensions were 3.3 mm in diameter and 5.0 mm in length, were used in this research. All implants (n = 24), made of commercially pure (grade IV) titanium, were divided into 2 groups. Twelve implants (n = 12) were machined without any surface modification (control). The test implants (n = 12) were anodized and coated with thin film (150nm) of calcium phosphate by electron-beam deposition. The implants were placed on the proximal surface of the rabbit tibiae. The bone to implant contact (BIC) ratios was evaluated after 3 and 6 weeks of implant insertion. Results: The BIC percentage of calcium phosphate coated implants ($70.8{\pm}18.9%$) was significantly higher than that of machined implants ($44.1{\pm}16.5%$) 3 weeks after implant insertion (P = 0.0264). However, there was no significant difference between the groups after 6 weeks of healing (P > .05). Conclusion: The histomorphometric evaluation of implant surface revealed that; 1. After 3 weeks early healing period, bone to implant contact (BIC) percentage of calcium phosphate coated implants (70.8%) was much greater than that of surface untreated machined implants (44.1%) with P = 0.0264. 2. After 6 weeks healing period, however, BIC percentage of calcium phosphate coated implants group (79.0%) was similar to the machined only implant group (78.6%). There was no statistical difference between two groups (P = 0.8074). 3. We found the significant deference between the control group and experimental group during the early healing period of 3 weeks. But no statistical difference was found between two groups during the later of 6 weeks.

Histomorphometry and Stability Analysis of Loaded Implants with two Different Surface Conditions in Beagle Dogs (하중을 가한 두 가지 표면의 임플란트에 관한 조직형태학적 분석 및 안정성 분석 (비글견을 이용한 연구))

  • Kim, Sang-Mi;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.337-349
    • /
    • 2008
  • Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions. This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in delayed loading conditions. A total of 36 solid screw implants (diameter 3.75 mm, length 10mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium Implants served as control. Gold crowns were inserted 3 months. Radiographic assessments and stabilitytests were performed at the time of fixture installation, $2^{nd}$ stage surgery, 1 and 3 months after loading. Histological observations and morphometrical measurements were also performed. Of 36 implants, 32 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (p=0.413) and RFA values. The mean BIC % in the Mg-implants was $54.4{\pm}20.2%$. The mean BIC % in the turned implant was $48.9{\pm}8.0%$. These differences between the Mg-implant and control implant were not statistically significant (P=0.264). In the limitation of this study, bone-to-implant contact (BIC) and bone area of Mg-incorporated oxidized implant were similar to machine-turned implant. The stability analysis showed no significantly different ISQ values and marginal bone loss between two groups. Considering time-dependent bone responses of Mg-implant, it seems that Mg-implants enhanced bone responses in early loading conditions and osseointegrated similarly to cp Ti implants in delayed loading conditions. However, further investigations are necessary to obtain long-term bone response of the Mg-implant in human.