• Title/Summary/Keyword: 고준위 방사성폐기물

Search Result 350, Processing Time 0.024 seconds

Safety Assessment on Disposal of HLW from P&T Cycle (핵변환 잔류 고준위 방사성 폐기물 처분 성능 평가)

  • 이연명;황용수;강철형
    • Tunnel and Underground Space
    • /
    • v.11 no.2
    • /
    • pp.132-145
    • /
    • 2001
  • The purpose and need of the study is to quantify the advantage or disadvantage of the environmental friendliness of the partitioning of nuclear fuel cycle. To this end, a preliminary study on the quantitative effect of the partition on the permanent disposal of spent PWR and CANDU fuel (HLW) was carried out. Before any analysis, the so-called reference radionuclide release scenario from a potential repository embedded into a crystalline rock was developed. Firstly, the feature, event and processes (FEPs) which lead to the release of nuclides from waste disposed of in a repository and the transport to and through the biosphere were identified. Based on the selected FEPs, the ‘Well Scenario’which might be the worst case scenario was set up. For the given scenario, annual individual doses to a local resident exposed to radioactive hazard were estimated and compared to that from direct disposal. Even though partitioning and transmutation could be an ideal solution to reduce the inventory which eventually decreases the release time as well as the peaks in the annual dose and also minimize the repository area through the proper handling of nuclides, it should overcome major disadvantages such as echnical issues on the partitioning and transmutation system, cost, and public acceptance, and environment friendly issues. In this regard, some relevant issues are also discussed to show the direction for further studies.

  • PDF

A Study on the Determination of the Seasonal Heat Transfer Coefficient in KURT Under Forced Convection (강제대류시 계절에 따른 KURT 내 열전달계수 결정에 관한 연구)

  • Yoon, Chan-Hoon;Kwon, Sang-Ki;Hwang, In-Phil;Kim, Jin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.3
    • /
    • pp.189-199
    • /
    • 2010
  • In a high-level waste (HLW) repository, heat is generated by the radioactive decay of the waste. This can affect the safety of the repository because the surrounding environment can be changed by the heat transfer through the rock. Thus, it is important to determine the heat transfer coefficient of the atmosphere in the underground repository. In this study, the heat transfer coefficient was estimated by measuring the indoor environmental factors in the Korea Atomic Energy Research Institute Underground Research Tunnel (KURT) under forced convection. For the experiment, a heater of 5 kw capacity, 2 meters long, was inserted through the tunnel wall in the heating section of KURT in order to heat up the inside of the rock to $90^{\circ}C$, and fresh air was provided by an air supply fan connected to the outside of the tunnel. The results showed that the average air velocity in the heating section after the provision of the air from outside of the tunnel was 0.81 m/s with the Reynolds number of 310,000~340,000. The seasonal heat transfer coefficient in the heating section under forced convection was $7.68\;W/m^2{\cdot}K$ in the summer and $7.24\;W/m^2{\cdot}K$ in the winter.

Conceptual Modeling Coupled Thermal-Hydrological-Chemical Processes in Bentonite Buffer for High-Level Nuclear Waste Repository (고준위 방사성폐기물 처분장에서 벤토나이트 완충제에 대한 열-수리-화학 작용 개념 모델링)

  • Choi, Byoung-Young;Ryu, Ji-Hun;Park, Jinyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.14 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • In this study, thermal-hydrological-chemical modeling for the alteration of a bentonite buffer is carried out using a simulation code TOUGHREACT. The modeling results show that the water saturation of bentonite steadily increases and finally the bentonite is fully saturated after 10 years. In addition, the temperature rapidly increases and stabilizes after 0.5 year, exhibiting a constant thermal gradient as a function of distance from the copper tube. The change of thermal-hydrological conditions mainly results in the alteration of anhydrite and calcite. Anhydrite and calcite are dissolved along with the inflow of groundwater. They then tend to precipitate in the vicinity of the copper tube due to its high temperature. This behavior induces a slight decrease in porosity and permeability of bentonite near the copper tube. Furthermore, this study finds that the diffusion coefficient can significantly affect the alteration of anhydrite and calcite, which causes changes in the hydrological properties of bentonite such as porosity and permeability. This study may facilitate the safety assessment of high-level radioactive waste repositories.

Geological Factor Analysis for Evaluating the Long-term Safety Performance of Natural Barriers in Deep Geological Repository System of High-level Radioactive Waste (지질학적 심지층 처분지 내 천연방벽의 고준위 방사성 폐기물 장기 처분 안전성 평가를 위한 지질학적 인자 분석)

  • Hyeongmok Lee;Jiho Jeong;Jaesung Park;Subi Lee;Suwan So;Jina Jeong
    • Economic and Environmental Geology
    • /
    • v.56 no.5
    • /
    • pp.533-545
    • /
    • 2023
  • In this study, an investigation was conducted on the features, events, and processes (FEP) that could impact the long-term safety of the natural barriers constituting high-level radioactive waste geological repositories. The FEP list was developed utilizing the IFEP list 3.0 provided by the Nuclear Energy Agency (NEA) as foundational data, supplemented by geological investigations and research findings from leading countries in this field. A total of 49 FEPs related to the performance of the natural barrier were identified. For each FEP, detailed definitions, classifications, impacts on long-term safety, significance in domestic conditions, and feasibility of quantification were provided. Moreover, based on the compiled FEP list, three scenarios that could affect the long-term safety of the disposal facility were developed. Geological factors affecting the performance of the natural barrier in each scenario were selected and their relationships were visualized. The constructed FEP list and the visualization of interrelated factors in various scenarios are anticipated to provide essential information for selecting and organizing factors that must be considered in the development of mathematical models for quantitatively evaluating the long-term safety of deep geological repositories. In addition, these findings could be effectively utilized in establishing criteria related to the key performance of natural barriers for the confirmation of repository sites.

Existence and Characteristics of Microbial cells in the Bentonite to be used for a Buffer Material of High-Level Wastes (고준위폐기물 완충재로 사용되는 벤토나이트의 미생물의 존재 및 특성)

  • Lee, Ji Young;Lee, Seung Yeop;Baik, Min Hoon;Jeong, Jong Tae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.11 no.2
    • /
    • pp.95-102
    • /
    • 2013
  • There was a study for biological characteristics, except for physico-chemical and mineralogical properties, on the natural bentonite that is considered as a buffer material for the high-level radioactive waste disposal site. A bentonite slurry that was prepared from a local 'Gyeongju bentonite' in Korea was incubated in a serum bottle with nutrient media over 1 week and its stepwise change was observed with time. From the activated bentonite in the nutrient media, we can find a certain change of both solid and liquid phases. Some dark and fine sulfides began to be generated from dissolved sulfate solution, and 4 species of sulfate-reducing bacteria (SRB) were identified as living cells in samples that were periodically taken and incubated. These results show that sulfate-reducing (or metal-reducing) bacteria are adhering and existing in the powder of bentonite, suggesting that there may be a potential occurrence of longterm biogeochemical effects in and around the bentonite buffer in underground anoxic environmental conditions.

An Influence Analysis on the Gap Space of an Engineered Barrier for an HLW Repository (고준위폐기물처분장 공학적방벽의 갭 공간이 미치는 영향 분석)

  • Yoon, Seok;Lee, Changsoo;Kim, Min-Jun
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.4
    • /
    • pp.19-26
    • /
    • 2021
  • The high-level radioactive waste (HLW) produced from nuclear power plants is disposed in a rock-mass at a depth of hundreds meters below the ground level. Since HLW is very dangerous to human being, it must be disposed of safely by the engineered barrier system (EBS). The EBS consists of a disposal canister, backfill material, buffer material, and so on. When the components of EBS are installed, gaps inevitably exist not only between the rock-mass and buffer material but also between the canister and buffer material. The gap can reduce water-retarding capacity and heat release efficiency of the buffer material, so it is necessary to investigate properties of gap-filling materials and to analyze gap spacing effect. Furthermore, there has been few researches considering domestic disposal system compared to overseas researches. In this reason, this research derived the peak temperature of the bentonite buffer material considering domestic disposal system based on the numerical analysis. The gap between the canister and buffer material had a minor effect on the peak temperature of the bentonite buffer material, but there was 40% difference of the peak temperature of the bentonite buffer material because of the gap existence between the buffer material and rock mass.

Simulation of Unsaturated Fluid Flow on the 2nd Phase Facility at the Wolsong LILW Disposal Center (경주 중저준위방폐장 2단계 처분시설의 불포화 환경하에서 침투수 유동 해석)

  • Ha, Jaechul;Lee, Jeonghwan;Yoon, Jeonghyoun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.3
    • /
    • pp.219-230
    • /
    • 2017
  • This study was conducted to predict and evaluate the uncertainty of safety after closure of the second phase surface disposal facility of the Gyeongju intermediate and low level repository in Korea. In this study, four scenarios are developed considering both intact and degraded states of multi-layered covers and disposal containers; also, the fluid flow by a rainfall into the disposal facility is simulated. The rainfall conditions are implemented based on the monthly average data of the past 30 years (1985~2014); the simulation period is 300 years, the management period regulated by institutional provisions. As a result of the evaluation of the basic scenario, in which the integrity of both of the containers and the covers is maintained, it was confirmed that penetration of rainfall does not completely saturate the inside of the disposal facility. It is revealed that the multiple cover layers and concrete containers effectively play the role of barrier against the permeation of rainfall.

Spent Nuclear Fuel Management in South Korea: Current Status and the Way Forward (사용후핵연료 관리 현안 및 정책 제언)

  • Hwang, Yongsoo;Chang, Sunyoung;Han, Jae-Jun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.5
    • /
    • pp.312-323
    • /
    • 2015
  • This paper presents future directions for spent nuclear fuel and high-level radioactive waste management. The successes and failures of siting nuclear waste repository experienced by the United States and other countries are reviewed with the current policy stance. Further, the needs for establishing management policy, considering the high-level radioactive waste produced by the dismantlement, nuclear security concerns, and cost-effectiveness analysis for the total nuclear fuel cycle, are emphasised. Technical discussions are organised into three main topics: interim storage, permanent disposal, and reprocessing. Licensing regimes are also investigated to suggest strategic plans for research and development programmes in the Republic of Korea.

Fabricability of the canister of high-level radioactive wastes (고준위폐기물 처분용기 제작성 분석)

  • 최희주;전관식;이양;조동건;이종열;최종원
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.163-170
    • /
    • 2005
  • 가압경수로형 사용후핵연료 처분용기에 대한 개념설계 및 안전성분석이 완료되어 이를 상용화하기 위한 단계로서 처분용기의 국내 제작성을 분석하였다. 용기의 내부구조물 제작성 확인을 위하여 실규모 용기의 직경 1/2, 길이 1/5인 소규모 용기를 설계하였다. 직경에 비해 길이가 크게 줄어 주조시 예상되는 사용후핵연료 바스켓의 변형을 관찰하기에는 적합하지 알았으나 이에 대한 문제는 향후 용기 규또를 확대하며 해결하여야 할 것으로 판단되었다. 용기의 제작 공정에 대해 검토하고 절차를 수립하였다 처분용기 내부구조물은 주조를 통해 제작할 계획이며. 이를 위한 주형틀 개념을 제시하였다. 개념설계 된 소규모 용기에 대해 구조 해석을 수행하고, 구조 해석 견과로부터 시험용기의 강도 시험을 위한 시편 채취 위치를 선정하였다. 용기 제조 후 시험 방안을 수립하였다.

  • PDF