• Title/Summary/Keyword: 고정핀

Search Result 130, Processing Time 0.024 seconds

A clinical report of hybrid telescopic double crown denture with friction pin in a failed double crown denture case (실패한 이중관 국소의치에서 하이브리드 텔레스코픽 이중관 국소의치를 이용한 임상증례)

  • Park, Jong-Hoon;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.2
    • /
    • pp.201-209
    • /
    • 2021
  • In removable partial dentures, many types of retentive systems have been studied and applied in clinical treatment. One of those systems is the double crown denture system which is widely used in European countries such as Germany and Sweden. Telescopic double crown dentures have several advantages such as convenience in maintaining oral hygiene, enabling to transfer occlusal force along the long axis of the abutment, and secondary splinting effect between the abutments which leads to higher clinical performance compared to conventional removal partial dentures. In this clinical case, the patient was initially restored with a maxillary hybrid telescopic double crown denture with friction pin using remaining natural teeth as abutments. After 7 years, due to lack of recall check-up and poor oral hygiene, the abutment teeth were affected by periodontitis and 4 out of 5 of the abutment teeth had to be extracted. 3 additional implants were placed and the original abutment tooth with the inner crown was maintained. The mandible had fixed prostheses including implants but nevertheless, with strategic implant placement, the patient adapted well and was satisfied with the new maxillary tooth-implant combined double crown denture.

Posterior Cruciate Ligament and Posterolateral Structure Reconstruction using Bilateral Hamstring Tendons (양측 슬괵건을 이용한 후방 십자 인대 및 후외측 지대 재건술)

  • In, Yong;Kim, Seok-Jung;Lee, Gyu-Yeong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.167-173
    • /
    • 2005
  • Purpose: The purpose of this study is to evaluate the clinical results of posterior cruciate ligament (PCL) and posterolateral structure (PLS) reconstruction using bilateral hamstring tendon autografts. Materials and Methods: From October 2002 to March 2004, ten patients were received PCL and PLS reconstruction simultaneously using bilateral hamstring autografts. PCL was reconstructed using ipsilateral hamstring tendon and fixed with cross pins and Intrafix (Mitek, Norwood, MA). PLS was reconstructed using contralateral hamstring tendon. The mean follow up was 17 months. Clinical assessments consisted of Lysholm knee scores, International Knee Documentation Committee (IKDC) evaluation form and posterior stress radiographs. External rotation of tibia was evaluated at $30^{\circ}\;and\;90^{\circ}$ knee flexion using Noyes and Barber-Westin's classification. Contralateral harvest site morbity was evaluated using IKDC evaluation form and flexion power of the knee. Results: Mean posterior displacement of tibia using stress radiographs was improved from 13.3 mm to 3.7 mm. In tibial external rotation evaluation, 7 patients were functional, 2 patients were partially functional and one failure. The average Lysholm knee score improved from 54 preoperatively to 86 postoperatively. At the final IKDC evaluation, 8 patients were graded as nearly normal, 2 were graded as abnormal. In contralateral harvest site morbidity evaluation, 2 patients complained of numbness around the wound but negligible. Conclusion: PCL and PLS reconstruction using bilateral hamstring autografts was considered as a good treatment method with minimal contralateral harvest site morbidity.

  • PDF

Energy Saving Effect for High Bed Strawberry Using a Crown Heating System (고설 딸기 관부 난방시스템의 에너지 절감 효과)

  • Moon, Jong Pil;Park, Seok Ho;Kwon, Jin Kyung;Kang, Youn Koo;Lee, Jae Han;Kim, Hyung Gweon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.420-428
    • /
    • 2019
  • This study is the heating energy saving test of the high-bed strawberry crown heating system. The system consists of electric hot water boiler, thermal storage tank, circulation pump, crown heating pipe(white low density polyethylene, diameter 16mm) and a temperature control panel. For crown heating, the hot water pipe was installed as close as possible to the crown part after planting the seedlings and the pipe position was fixed with a horticultural fixing pin. In the local heating type, hot water at $20{\sim}23^{\circ}C$ is stored in the themal tank by using an electric hot water boiler, and crown spot is partially heated at the setting temperature of $13{\sim}15^{\circ}C$ by turning on/off the circulation pump using a temperature sensor for controlling the hot water circulation pump which was installed at the very close to crown of strawberry. The treatment of test zone consisted of space heating $4^{\circ}C$ + crown heating(treatment 1), space heating $8^{\circ}C$(control), space heating $6^{\circ}C$ + crown heating(treatment 2). And strawberries were planted in the number of 980 for each treatment. The heating energy consumption was compared between November 8, 2017 and March 30, 2018. Accumulated power consumption is converted to integrated kerosene consumption. The converted kerosene consumption is 1,320L(100%) for space $8^{\circ}C$ heating, 928L(70.3%) for space $4^{\circ}C$ + crown heating, 1,161L($88^{\circ}C$) for space $6^{\circ}C$ + crown heating). It was analyzed that space $4^{\circ}C$ + pipe heating and space $6^{\circ}C$ + crown heating save heating energy of 29.7% and 12% respectively compared to $8^{\circ}C$ space heating(control).

Periodontal prosthesis on medically compromised patient with few remaining teeth: hybrid telescopic double crown with friction pin method (의과적 문제가 있고 소수 잔존치를 가지는 환자에서의 치주보철 임상증례: 프릭션핀을 이용한 하이브리드 텔레스코픽 이중관법)

  • Ha, Seok-Joon;Lee, Cheong-Hee;Cho, Jin-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.52 no.4
    • /
    • pp.359-365
    • /
    • 2014
  • Successful results of treatments using double crown prostheses for the partially edentulous patients who have a few remaining teeth have been reported in several journals. A double crown removable partial denture can be an alternative treatment for the patients with a poor periodontal condition of remaining teeth. Since a double crown removable partial denture can be applied without the risk of surgical operation to the medically compromised patients with a poor periodontal condition which is inadequate for dental implants, it has psychological and economical advantages. In this case, there were sufficient remaining teeth to be restored with fixed prostheses in maxilla, while there were a few remaining teeth with a very poor periodontal condition so that it was almost impossible to restore with a clasp removable partial denture using these remaining teeth in mandible. In addition, the patient had the medical history of surgical operation due to osteomyelitis in the mandibular anterior areas a year ago, thus difficult to conduct an implant placement. The main objective of this report is to introduce our case because a double crown partial denture using a few mandibular remaining teeth showed satisfactory results in functional and esthetical aspects during more than two years follow-up period in this unfavorable condition.

Effects of Chitosan on Fracture Healing in Fractured Rat Model. (골절모델 쥐에서 키토산 투여가 골절치유에 미치는 영향)

  • 서정욱;김은주;한상섭
    • Journal of Life Science
    • /
    • v.14 no.3
    • /
    • pp.385-390
    • /
    • 2004
  • Chitosan is abundant polysaccharide polymer in nature Chitosan has been the subject of much research regarding its potential as a nutritional adjunct and pharmaceutical ingredient. In the present study, we examined fracture-healing process with chitosan administration and low calcium diet in rats. Left femur was fractured and fixed with intramedullary pin. The rats were fed normal diet or low calcium diet and administered chitosan with the doses of 0, 50, 100 and 150ng/ml orally 5 times a week for 10 weeks. Soft X-ray and mechanical testing of all fractured femora was taken. Radiographical finding showed that the callus formation and process of fracture healing was present in all the fractured femora. Mechanical testing indicated that the maximum load and stiffness of femur in rat fed low calcium diet was lower than those of that in rat fed normal diet. No difference in maximum load and stiffness of fractured femora in chitosan treated rat were observed as compared to vehicle treated rat. Chitosan or/and low calcium diet did not affect the ratio of fractured/unfractured femur about maximum load and stiffness. The results suggest that chitosan dose not affect the bone mechanical strength and the process of fracture healing. Low calcium diet does decrease the bone mechanical strength.

Effects of Compatibilizer and Graphene Oxide on the Impact Strength of PC/ABS Blend (PC/ABS의 충격강도에 미치는 상용화제와 그래핀 옥사이드의 영향)

  • Park, Ju Young;Lee, Bom Yi;Cha, Hye Jin;Kim, Youn Cheol
    • Applied Chemistry for Engineering
    • /
    • v.26 no.2
    • /
    • pp.173-177
    • /
    • 2015
  • In this study, effects of both the grafted ABS-g-MAH and the added graphene oxide (GO) on the impact strength of polycarbonate (PC)/poly(acrylonitrile-butadiene-styrene) (ABS) blends were discussed. The PC/ABS blends and PC/ABS/GO composites were fabricated by using twin screw extruder with ABS-g-MAH as a compatibilizer. The ABS-g-MAH was prepared by melting extrusion of ABS and maleic anhydride (MAH) with DCP (dicumyl peroxide) as an initiator using twin screw extruder and the synthesis of ABS-g-MAH was confirmed by the presence of carbonyl group (C=O) peak at $1780cm^{-1}$ of FT-IR spectrum. According to the thermal, rheological, and impact properties of PC/ABS blends, 5 phr (parts per hundred resin) of compatibilizer was chosen as an optimum content for the PC/ABS/GO composites. It was observed that the thermal decomposition of ABS/PC/GO composites increased with GO contents, but there was no significant changes or a decrease in the impact strength. Also the composite fabricated by ABS/GO showed small increase in the impact strength. From the result of the dynamic rheometer to observe the processing properties, the complex viscosities of PC/ABS blend including the compatibilizer increased, but the complex viscosities of composites added GO were not changed.

Development of A Component and Advanced Model for The Smart PR-CFT Connection Structure (스마트 반강접 (PR) 콘크리트 충전 강재 합성 (CFT) 접합 구조물에 대한 해석모델의 개발)

  • Seon, Woo-Hyun;Hu, Jong-Wan
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.2 no.4
    • /
    • pp.1-10
    • /
    • 2011
  • This study investigates the performance of composite (steel-concrete) frame structures through numerical experiments on individual connections. The innovative aspects of this research are in the use of connections between steel beams and concrete-filled tube (CFT)columns that utilize a combination of low-carbon steel and shape memory alloy (SMA) components. In these new connections, the intent is to utilize the recentering provided by super-elastic shape memory alloy tension bars to reduce building damage and residual drift after a major earthquake. The low-carbon steel components provide excellent energy dissipation. The analysis and design of these structures is complicated because the connections cannot be modeled as being simply pins or full fixity ones they are partial restraint (PR). A refined finite element (FE) model with sophisticated three dimensional (3D) solid elements was developed to conduct numerical experiments on PR-CFT joints to obtain the global behavior of the connection. Based on behavioral information obtained from these FE tests, simplified connection models were formulated by using joint elements with spring components. The behavior of entire frames under cyclic loads was conducted and compared with the monotonic behavior obtained from the 3D FE simulations. Good agreement was found between the simple and sophisticated models, verifying the robustness of the approach.

Nanocomposite Water Treatment Membranes: Antifouling Prospective (수처리용 나노복합막: 방오의 관점에서)

  • Kim, Soomin;Patel, Rajkumar
    • Membrane Journal
    • /
    • v.30 no.3
    • /
    • pp.158-172
    • /
    • 2020
  • In the aspect of saving energy and water, facilitating the separation membrane for the water treatment has been rising recently as one of the possible solutions. However, microbial biofouling effect is the biggest obstacle that hinders reaching higher permeability over a prolonged period of nanofiltration operation. To solve this problem and fully utilize the filtration membranes with enhanced performance, largely two kinds of solutions are studied and the first and the most commonly mentioned type is the one using the silver nanoparticles. Since silver nanoparticles are important to be well tailored on membrane surface, various methods have been applied and suggested. Using silver nanoparticles however also has the drawbacks or possible toxicity risks, raising the need for other types of utilizing non silver particles to functionalize the membrane, such as copper, graphene or zinc oxides, and amine moieties. Each attempt included in either kind has produced some notable results in killing, preventing, or repelling the bacteria while at the same time, left some unsolved points to be evaluated. In this review, the effects of metal nanoparticles and other materials on the antifouling properties of water treatment membranes are summarized.

Effects of Electrical Stimulation on the Mast Cell of Skin in Rats (전기자극이 흰쥐의 피부 비만세포에 미치는 영향)

  • Lee Jae-Hyoung;Jekal Seung-Joo;Park Seung-Teack
    • The Journal of Korean Physical Therapy
    • /
    • v.11 no.3
    • /
    • pp.81-87
    • /
    • 1999
  • The purpose of this study was to determine the effect of electrical stimulation on the number of MCs and percent of degranulated MCs in rat skin. Twelve male Sprague-Dawley rats were divided into two group; electrical stimulation group (n=6) and control group (n=6). Each animals hair on the back was removed. The electrical stimulation group received an positive rectangular pulsed electrical stimulation, while the control group was given the same treatment without electricity. The biopsy specimens were fixed in formalin, embedded in paraffin and stained with toluidine blue-nuclear fast red and alcian blue-safranin O. respectively. The MCs were counted using a light microscope and computerized image analysis system and calculated as the density and the percent. A t-test showed a significantly higher density of MCs in the electrical stimulated rats than control rats(p<0.05), and the percent of degranulated MCs in the electrical stimulated rats was higher than in the control rats (p<0.05) in toluidine blue stained sections. The density of MCs was significantly higher in the electrical stimulated rats than the control rats in alcian blue-safranin O Stained sections (P<0.01). An analysis of variance showed that the densities of CTMCs was significantly lower than the densities of MMCs and mixed MCs in electrical stimulated rat in alcian blue-safranin O Stained sections (p<0.05). These results suggest that the electrical stimulation may have potential for increasing the number of MCs and lead to degranulate the MCs in rat skin.

  • PDF

Electroacupuncture and "Duhuojisheng-tang" Administration for Postoperative Treatment in 3 dogs with Traumatic Spinal Cord Injury (외상성 척수 손상에 대한 척추 수술을 한 3마리의 개에서, 술 후 처치로써 전침과 독활기생탕을 적용한 증례)

  • Kim, Min-Su;Kim, Se-Hoon;Cha, Jae-Gwan;Kim, Nam-Soo;Kang, Hyung-Sub
    • Journal of Veterinary Clinics
    • /
    • v.28 no.3
    • /
    • pp.318-322
    • /
    • 2011
  • Three dogs with severe traumatic spinal cord injury (TSCI) due to falling wound were admitted to the Veterinary Medical Center, Chonbuk National University for evaluation of severe pelvic limbs paralysis without deep pain, normal defecation and urination. Based on physical examination, neurological assessment and computed tomogram (CT), the diagnosis was made as subluxation and compressed fracture. All the cases were surgically treated with dorsal laminectomy and a spondylosyndesis using pin and bone cements. For 2 weeks, the dogs didn't show any improvement. Consequently, the dogs were treated with electroacupuncture (EA) and Duhuojisheng-tang (DHJST). All the dogs got back the deep pain and presented wagged tail on 14-35 days after starting EA with DHJST. Especially, two of 3 dogs recovered almost normal ambulation and capacities of urination and defecation. But, one dog failed to regain normal ambulation due to inflammation of operative site which is thought to be caused by the bone cement. From these cases, it was thought that the combination of EA and DHJST mightbe one of the suitable therapies in dogs with no neurological improvement.