• Title/Summary/Keyword: 고상검출기

Search Result 16, Processing Time 0.019 seconds

Assessment of PCBs-containing solid wastes using official wastes test method (폐기물공정시험방법을 이용한 PCBs 함유 고상폐기물의 적용성 평가)

  • Kim, Kyeo-Keun
    • Analytical Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.261-268
    • /
    • 2010
  • This study was performed to evaluate the PCBs-containing wastes using official test method. Ninety samples of transformer oil and various solid waste were collected to assess the analytical results. In the analysis of PCBs-containing wastes, the PCBs levels were detected in the range of 7.6 mg/kg to 23.8 mg/kg for transformer oils, $0.02\sim0.54\;{\mu}g/100cm^2$ for plat solid wastes, and 0.01~0.071 mg/kg for amorphous solid waste. In the cupper wire waste of the transformer with oil concentration level of 23 mg/kg, the analytical result exceed PCBs regulation level of 0.04 mg/kg. The new proposed analytical method for PCBs containing waste can be forced to effective management of the wastes.

Compressibility of $FeS_{2}$ ($FeS_{2}$의 압축성 연구)

  • Kim, Young-Ho;Hwang, Gil-Chan;Cho, Hyen-Goo
    • Journal of the Mineralogical Society of Korea
    • /
    • v.19 no.3 s.49
    • /
    • pp.189-195
    • /
    • 2006
  • Compression work on a pyrite powder has been carried out using energy dispersive X-ray diffraction (EDXRD) with Mao-Bell type diamond anvil cell (DAC) and synchrotron radiation(SR) at room temperature. It has been reported the bulk moduli of pyrite show the large variations depending on the experimental conditions as well as the apparatus used. Thus, two kinds of sample in different pressure transmitting media of both NaCl and MgO powder emerged in alcoholic fluids were subjected to measure their compressibilities. Bulk moduli thus obtained are 138.9 GPa and 198.2 GPa, respectively, and this result contradicts to the anticipated values according to the hydrostaticity conditions of the sample chamber. This might be due to the alcoholic fluids phase transition mainly with the side effects from the difference of both solid state detector (SSD) used and E*d value applied. All experiments were performed at the Beam Line 1B2 of Pohang Light Source (PLS).

Quantification of Volatile Organic Compounds in Gas Sample Using Headspace Solid-Phase Microextraction (고상 미세 추출법을 이용한 가스시료 중 휘발성유기화합물의 정량 분석)

  • Kim, Jae Hyuck;Kim, Hyunook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.906-917
    • /
    • 2013
  • The purpose of this study is to quantify volatile organic compounds (VOCs) in gas sample using headspace solid-phase microextraction (HS-SPME) coupled to GC analysis. The optimal HS-SPME conditions was CAR/PDMS fiber and 30 min absorprion time for the analysis of various VOCs. In optimal conditions, 80 VOCs could be detected within 1 ppbv and even less than 0.0005 ppbv especially in the case of BTEX. However, fiber reproducibility on adsorption efficiency was 1~9.2% (between the same fiber) and 5.9~13.5% (between the other fiber). We successfully determined 35 VOCs in landfill gas with this method and found that VOCs of high concentration are emitting from vent pipe of closed/open landfill site under the HS-SPME conditions. This method may apply to VOCs/odor determination from various atmospheric environmental samples as well as landfills.

Polyphonic sound event detection using multi-channel audio features and gated recurrent neural networks (다채널 오디오 특징값 및 게이트형 순환 신경망을 사용한 다성 사운드 이벤트 검출)

  • Ko, Sang-Sun;Cho, Hye-Seung;Kim, Hyoung-Gook
    • The Journal of the Acoustical Society of Korea
    • /
    • v.36 no.4
    • /
    • pp.267-272
    • /
    • 2017
  • In this paper, we propose an effective method of applying multichannel-audio feature values to GRNNs (Gated Recurrent Neural Networks) in polyphonic sound event detection. Real life sounds are often overlapped with each other, so that it is difficult to distinguish them by using a mono-channel audio features. In the proposed method, we tried to improve the performance of polyphonic sound event detection by using multi-channel audio features. In addition, we also tried to improve the performance of polyphonic sound event detection by applying a gated recurrent neural network which is simpler than LSTM (Long Short Term Memory), which shows the highest performance among the current recurrent neural networks. The experimental results show that the proposed method achieves better sound event detection performance than other existing methods.

Application of On-Line SPE-LC/MSD to Measure Perfluorinated Compounds (PFCs) in Water (On-Line SPE-LC/MSD 시스템을 이용한 수중의 과불화 화합물(PFCs) 분석)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Jung, Jong-Moon;Jang, Seung-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.75-83
    • /
    • 2013
  • We applied a sensitive method based on on-line solid-phase extraction (SPE) and liquid chromatography/mass spectrometry (LC/MSD) using an electrospray interface for the determination of eleven perfluorinated compounds (PFCs) in water. The on-line connection suppressed the target loss by keeping the cartridge from drying, which resulted in improvement of the recovery and saving of the analytical time. For the on-line solid-phase extraction of 10 mL water samples, recoveries were between $80.4{\pm}5.2%{\sim}109.5{\pm}1.4%$ and limit of quantification (LOQ) were 3.6~15.9 ng/L for the PFCs. The total PFCs concentrations of the tributaries and main stream of Nakdong River water samples were in the range of $8.0{\sim}678.6{\mu}g/L$.

Detection and Classification of Open-phase Faults in PMSM Using Extended Kalman Filter and Multiple Model (확장칼만필터 및 다중모델 기반 영구자석 동기전동기 권선 개방 고장의 검출 및 분류)

  • Minwoo Kim;Junhyeong Park;Sangho Ko
    • Journal of Aerospace System Engineering
    • /
    • v.17 no.6
    • /
    • pp.100-107
    • /
    • 2023
  • Open-phase fault in a Permanent Magnet Synchronous Motor (PMSM) occurs due to disconnection of phases of motor windings or inverter switch failures. When an open-phase occurs, it leads to the generation of torque ripples and vibrations in the motor, which can have a critical impact on the safety of the vehicle (including aircraft) using a PMSM as an actuator. Therefore, rapid fault detection and classification are essential. This paper proposes a classification method for detecting open-phase faults and locating fault positions in a PMSM used in aircraft applications. The proposed approach uses an Extended Kalman Filter for fault diagnosis, and it subsequently classifies faults using a Multiple Model filter.

Sample Preparation for Quantitative Determination of Bisphenols in Canned Beverages Coated with Epoxy by RP-HPLC (RP-HPLC 에 의한 에폭시 통조림관 음료 중 비스페놀류의 분석을 위한 시료의 전처리)

  • Kang, Kyung-Mo;Lim, Heung-Youl;Shin, Hyo-Sun
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.1029-1034
    • /
    • 2000
  • A suitable method of sample treatments to minimize the analytical interferences was presented in order to determine bisphenols [bisphenol F (BPF), bisphenol A (BPA), bisphenol F diglycidyl ether (BFDGE), and bisphenol A diglycidyl ether (BADGE)] in various canned beverages coated with epoxy resin by the reversephase high performance liquid chromatography (RP-HPLC) equipped with a fluorescence detector and the gas chromatography with mass selective detection. The recovery test of bisphenols was performed using 1, 5, and 10 ${\mu}g/L$ bisphenols spiked beverages with the combined technique of the solid-phase extraction (SPE) and the liquid-phase extraction (LPE). Both BPA and BADGE showed quite adequate resolutions in HPLC-chromatograms. The recoveries of BPA obtained by LPE with diethyl ether were higher than those obtaind with methylene chloride on coffee, shikhye and fruit juice. For cola and tea, the recoveries of BPA obtaind by SPE were higher than those by LPE with diethyl ether. The recoveries of BADGE were less than those of BPA for all beverage samples treated by either SPE or LPE method. In survey of bisphenols for eighteen commercial canned beverage samples, BPA contents of coffee, cola, tea, shikhye, and fruit juice were in the range of $1.3{\sim}11.6,\;0.5{\sim}0.9,\;1.0{\sim}1.3,\;2.4{\sim}7.9$, and $3.0{\sim}3.4\;{\mu}g/L$, respectively, but there was no detection of BPA in beer sample.

  • PDF

Synthesis and Luminescence Properties of $GdNbO_4$ : $Eu^{3+}$ Phosphors

  • Gwon, Bang-Gil;Jo, Sin-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.324-325
    • /
    • 2011
  • 최근에 고효율의 적색 형광체를 합성하여 형광 램프, 음극선관, X-선 검출기, 전계 발광 디스플레이에 응용하기 위하여 다양한 모체 결정과 활성체를 도핑하는 연구가 활발히 진행되고 있다. 본 연구에서는 $GdNbO_4$ 모체 결정에 $Eu^{3+}$ 이온 활성체를 주입하여 합성함으로써 새로운 적색 형광체의 발광 세기와 입자의 형상을 최적화 시키고자 한다. 형광체 분말 시료의 제조는 Eu의 함량을 0, 0.05, 0.10, 0.15, 0.20 mol로 변화시키면서 고상 반응법을 이용하여 합성하였다. 초기 물질 Gd2O3 (99.99%), $Nb_2O_5$ (99.99%), $Eu_2O_3$ (99.9%)를 화학 적량으로 측량하고 에탄올과 ZrO2 볼과 함께 플라스틱 병에 넣어 400 rpm의 속도로 24시간 볼밀 작업을 수행한 후에, 혼합된 분말의 볼을 걸러내고 60$^{\circ}C$에서 20시간 동안 건조하였다. 건조된 시료를 막자 사발에 넣고 잘게 갈아서 체로 걸러낸 다음에 세라믹 도가니에 넣고 전기로에서 분당 5$^{\circ}C$씩 승온하여 500$^{\circ}C$에서 10시간 동안 1차 하소한 후에, 계속 온도를 승온시켜 1,200$^{\circ}C$에서 3시간 동안 소결하여 합성하였다. XRD 회절 패턴의 경우에, $Eu^{3+}$의 함량에 관계없이 모든 세라믹은 JCPDS (22-1104)에 제시된 회절상과 일치하는 사방정계의 결정 구조를 가짐을 확인할 수 있었다. 주 피크는 28.4$^{\circ}$에서 최대값을 갖는 (121)면에서 발생하는 회절 신호이었다(Fig. 1). 적색 형광체 분말의 광학 및 표면 특성은 PL, PLE와 SEM으로 조사되었으며, 세라믹 분말의 형광 특성과 결정 구조, 표면 형상에 대한 자세한 논의가 제시될 것이다.

  • PDF

Analysis of anatoxin-a in aqueous and cyanobacterial samples from korean lakes by liquid chromatography with fluorescence detection (액체크로마토그래피-형광검출법에 의한 호소시료의 아나톡신-a 분석)

  • Lee, In-Jung;Lee, Chul-Gu;Heo, Seong-Nam;Lee, Jae-Gwan
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.225-230
    • /
    • 2011
  • Anatoxin-a is a cyanobacterial neurotoxin with a high toxicity produced by Anabaena, Aphanizomenon and Oscillatoria. Water bloom, formed by Anabaena has been occurring frequently in Lake Yeongchun. It is need to develop a sensitive method for determination of anatoxin-a to control potential hazard in raw water resources. In this study, we developed a highly sensitive analytical method of anatoxin-a using solid phase extraction (SPE) and high performance liquid chromatography (HPLC) with fluorescence detection. Anatoxin-a was converted into a highly fluorescent derivative using 4-fuoro-7-nitro-2,1,3-benzoxadiazole (NBF-F). The method was evaluated in terms of linearity of calibration curve, recovery and repeatability, and the adequate values were obtained. The method detection limit was $0.034\;{\mu}g/g$ and $0.022\;{\mu}g/L$ for algal and water samples, respectively. The concentrations of anatoxin-a were measured in algal and water samples from Lake Andong, Yeongchun and Daechung and ranged from $0.135\;{\mu}g/g$ to $10.979\;{\mu}g/g$ in algal samples and not detected in water samples.

Quantification of Odorants from Animal Husbandry using Solid-phase Microextraction (고상(固相) 미세 추출법에 의한 축산 관리시설에서 발생하는 악취성 가스 화합물의 정량적 평가)

  • Kim, Jae-Hyuck;Choi, Hong-Lim;Kown, So-Young;Lim, Hong-Lae;McConnell, Laura L.;Arispe, Susana;Park, Chul-Hwi;Kim, Hyun-Ook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.158-164
    • /
    • 2006
  • Offensive odor from CAFO(concentrated animal feeding operation) and its control have become a significant issue in Korea. Control of odors from the CAFO requires to identify major odorant and their generation mechanisms. In this study, an easy method to collect gas sample and to quantify its odorants is proposed. The method involves on-site odorant extraction with solid-phase microextraction and quantitation with GC/MSD or GC/FID. Analytes of the current study include: trimethylamine(TMA), carbon disulfide($CS_2$), dimethyl sulfide(DMS), dimethyl disulfide(DMDS), acetic acid(AA), propionic acid(PA) and n-butyric acid(BA). The resulting linearity($R^2$) of calibration curve for each analyte was good over the range from several ppbv to ppmv; 0.984 for TMA(0.056-1.437), 0.996 for $CS_2$(0.039-0.999), 0.994 for DMS(0.029-0.756), 0.995 for DMDS(0.024-0.623), 0.992 for AA(0.068-1.314), 0.955 for PA(0.047-0.940), and 0.976 for BA(0.036-0.712). Method detection limits were 5.67, 6.39, 5.78, 25.2, 0.098, 0.363 and 0.099 ppbv for AA, PA, BA, TMA, DMS, $CS_2$, and DMDS, respectively. With the developed method, odorants from poultry, swine, and cattle barns were analysed. All the compounds but DMDS were detected from the sample collected in the poultry barn, and their levels exceeded the representative published human olfactory threshold.