Treatment Efficiency Evaluation of Integrated Two-Phase Pilot-Scale Anaerobic Digestion Using Food Waste Leachate (Pilot Scale 일체형 2상 혐기성소화에서의 음폐수 처리효율 평가)

  • Song, Hancheul;Kim, Dongwook
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.24 no.2
    • /
    • pp.51-58
    • /
    • 2016
  • In the Integrated Two-Phase Anaerobic Digestion (ITPAD) process, acid and methane fermentation take place in one reactor, which has advantages to cope with organic load variation and reduce foot-print required, compensating disadvantages of Conventional Separated Two-Phase Anaerobic Digestion (CSTPAD). In the present work, organic matter degradation efficiency and biogas generation amount and other performance parameters of the ITPAD fed with food waste leachate were analyzed. In addition, feasibility study on the ITPAD method was performed by comparing its digestion efficiency with that of the CSTPAD. Organic matter alteration and biogas generation of the integrated method were examined for approximately 130 days based on the 5ton/day scaled pilot plant. Experiment results revealed that organic matter removal rate was 80% for mean food waste leachate input amount of $4.1m^3/day$. The biogas generation rate was $63.0m^3$ per ton of food waste leachate input, corresponding to the input VS amount of $0.724m^3/kg-VS_{added}$, and methane content of generated biogas was approximately 61.3%. The ITPAD has a comparable or higher organic matter removal efficiency compared to the conventional separated two-phase anaerobic digestion method. Consequently, the ITPAD method has a great need to commercialize a food waste leachate treatment technology against highly concentrated organic waste leachate.

Treatment of Waste Solution of Waste Refrigerant Decomposition Process Using Atmospheric Pressure Plasma (대기압 플라즈마를 이용한 폐냉매 분해 공정 폐수 처리)

  • Ko, Eun Ha;Yoo, Hyeonseok;Jung, Yong-An;Park, Dong-Wha;Kim, Dong-Wook;Choi, Jinsub
    • Applied Chemistry for Engineering
    • /
    • v.29 no.4
    • /
    • pp.479-483
    • /
    • 2018
  • Our group reported the thermal decomposition of R-22 ($CHClF_2$) refrigerants by nitrogen thermal plasma in previous studies. However, it was proposed that the wastewater generated from the end part of the process contains high concentration of fluoride ion which is a component of R-22. The additional post-treatment process to neutralize the $F^-$ ions in the wastewater was investigated in this study. The wastewater generated through the decomposition of R-22 with the same procedure in the previous work was treated using the neutralizer, $Ca(OH)_2$, and the atmospheric pressure plasma jet (APPJ) independently as a post-treatment process. Wastewater samples were collected directly after the treatment for ion-chromatography analysis to trace the change of the concentration of $F^-$ ion in the wastewater. The fluoride concentration in the wastewater showed the highest value when the single water was used as a neutralizer, and the concentration of fluoride in the wastewater was dramatically reduced when the post-treatments were performed.

Production of ${\delta}-Aminolevulinic$ Acid in Soybean Curd Wastewater by Rhodobacter capsulatus KK-10 (두부공업폐수에서 Rhodobacter capsulatus KK-10을 이용한 ${\delta}-Aminolevulinic$ Acid의 생산)

  • Cheong, Dae-Yeol;Choi, Yang-Mun;Yang, Han-Chul;Cho, Hong-Yon
    • Applied Biological Chemistry
    • /
    • v.40 no.6
    • /
    • pp.556-560
    • /
    • 1997
  • The removal efficiency of COD and the production of ${\delta}-aminolevulinic$ acid (ALA) were concurrently investigated for both purifying the soybean curd wastewater of high BOD and utilizing the wastewater as a renewable substrate of ALA production using Rhodobacter capsulatus KK-10. Its wastewater was a favorable media for the growth of photosynthetic bacteria in terms of its environmental characteristics having COD/BOD rate of 0.98, ratio of BOD : N : P=100 : 6 : 4, BOD/N ratio of 17.2, lactic acid of 1,080 ppm. Its COD value wastewater was decreased to 94% and dry cell weight was approached to about 1.2 g/l after cultivation of the photosynthetic bacteria for 4 days. By the addition of 15 mM levulinic acid (LA) into the wastewater at the middle log phase of cell growth, the amount of ALA secreted was 55 mg/l. The ALA production was considerably increased to 114 mg/l under the cultural condition of 15 mM supplementations of glycine and succinate with LA at the same period. Furthermore the maximum ALA production of 120 mg/l and COD removal efficiency of 92% were accomplished in the soybean curd wastewater enriched with one addition of 15 mM LA and three serial additions 15 mM ALA precursors.

  • PDF

Removal of Ammonia-Nitrogen Contained in Landfill Leachate by Ammonia Stripping(I) (암모니아 탈기공정을 이용한 침출수의 암모니아성 질소제거(I))

  • Lee, Byung-Jin;Cho, Soon-Haing
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1893-1904
    • /
    • 2000
  • Nitrogen compounds are one of the major pollutants which cause eutrophication problems of the river or lake and red tides problems of the ocean. Currently available technologies for the removal of nitrogen compounds are mostly biological treatment. However, biological treatment is only effective for the wastewater which contains low concentration of nitrogen compounds. Leachate from solid waste landfill or industrial wastewater which contains high concentration of nitrogen can not be effectively treated by most of the currently available biological treatment technologies. With this connection. the objective of this study is to examine the applicability of ammonia stripping technology for the removal of high concentration of ammonia nitrogen compounds of the leachate from solid waste landfill. It can be concluded that ammonia stripping technology which was placed before the biological treatment process was very effective for the removal of high concentration of ammonium compounds. The chemical cost for the ammonia stripping was 16 percent higher than MLE process, so other methods like sludge recycling are needed for the reduction of operation cost. Further details are discussed in this paper.

  • PDF

Optimum loading capacity and nitrification characteristics of the swine wastewater treatment process using soil microbe (토양미생물을 이용한 축산폐수 처리공정의 적정부하율과 질산화공정의 특성)

  • Ha, Jun-Soo;Shin, Nam-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.2
    • /
    • pp.183-187
    • /
    • 2000
  • Removal rate of nitrogen compound containing swine wastewater was 97 percent in case of high loading rate treatment of swine wastewater at studies for process development using soil microorganism. Minimum hydraulic retention time(HRT) for nitrification process was 11 days and solid retention time was 25 days. Nitrification was between 5 and 11 days but this time $NO_2-N$ was remained. Reactor condition was injured to nitrosomonas according to pH, $NO_2\;^--N$, and $NH_3\;^--N$ concentration but this condition was recover to pH controlling.

  • PDF

Swine wastewater treatment with soil microbes and its efficiency and dynamic parameters (토양미생물을 이용한 축산폐수 처리의 공정별 제거효율 및 동력학적 상수)

  • Park, Wan-Cheol;Shin, Nam-Cheol
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.2
    • /
    • pp.177-182
    • /
    • 2000
  • Removal rate of swine wastewater containing organic matter was 99 percent in case of high loading rate. The studies of swine wastewater treatment aim to development of process using soil microorganism. Microorganism was devoted to improve the treatment efficiency of the process. Biochemical oxygen demand (BOD) concentration of treated swine wastewater was under 150 mg/L in anaerobic reactor. Also, value of km and Y were $0.73\;hr^{-1}$ and 0.433 g/VSS/g BODrm/d at microorganism of post aeration tank in anaerobic reactor.

  • PDF

Treatment of high hexavalent chromium plating wastewater (고농도 6가 크롬 도금 폐수 처리)

  • Kang, Chang Duk;Sim, Sang Jun;Hwang, Suk Hoon
    • Clean Technology
    • /
    • v.7 no.1
    • /
    • pp.75-80
    • /
    • 2001
  • In this study, hexavalent chromium (Cr(VI)) plating wastewater in strong acidic condition was treated by reduction and alkalization. Ferrous sulfate ($FeSO_4$), known to reduce Cr(VI) to Cr(III) rapidly at acidic pH, was used as a reductant of Cr(VI). The optimum reduction condition of Cr(VI) was observed at iron to chromium dose ratio of 3:1 by mole concentration. The precipitation of Cr(III) as $Cr(OH)_3$, was achieved by the pH adjustment in the limestone aeration bed. The precipitates were removed less than the upper limit of chromium for effluent at pH over 5.0. The continuous removal of Cr(VI) was performed using the process consisting of reduction vessel, limestone aeration bed, and sedimentation tank coupled with metal screen membrane. As pH was maintained around 5.0 in the limestone aeration bed, insoluble chromic hydroxide flocs was formed continuously. Most chromic hydroxide flocs were filtered by the metal screen membrane with 1450 mesh size, and the treated water to meet the upper limits of chromium for effluent (Cr Conc. 0.25~0.90 mg/l) was obtained in 30 minutes. Periodic backwashing decreased the fouling on the membrane rapidly.

  • PDF

Reduction of Organic Sludge using High Efficiency Aeration System(HEAS) (고효율 포기 시스템을 이용한 유기성 슬러지의 감량화)

  • Oh, Sea-Bae;Lee, Sang-Houck
    • Journal of Digital Convergence
    • /
    • v.10 no.10
    • /
    • pp.221-227
    • /
    • 2012
  • In Korea, ocean dumping has been widely used as the ultimate disposal of sewage sludge. However, ocean dumping of food wasted and sewage sludge from 2013 is expected to legally restricted as London convention on marine pollution prevention has been effective in 2009. This research aims to examine the effect of HEAS in treating the environmental pollution load caused by organic high concentrated sludge. Thus, onsite laboratory scale treatability test using HEAS was adopted to treat the high concentrated organic sludge from sewage and industrial wastewater treatment plant. The research results showed that the HEAS is useful to reduce the environmental pollution caused by organic high concentrated sludge. Specific results are as follows. 1. The organic removal after the sludge digestion using the high efficiency aeration system was 55.2-85.8%. Although these results were lower than those from the general sewage treatment, the high efficiency aeration system could be evaluated as efficient, considering the object sludge contained the industrial waster water. 2. The average removal efficiency was about 25.2%. 3. It was revealed that sludge digestion by the high efficiency aeration system could effectively contribute to the sludge treatment cost. Especially, the high efficiency aeration system is more applicable to the onsite treatment of small sewage and wastewater treatment plant that contains high solid content sludge, industrial wastewater sludge, high fixed solid sludge.

Influence of Food Wastewater Loading Rate on the Reactor Performance and Stability in the Thermophilic Aerobic Process (음폐수 부하량에 따른 고온호기성 공정의 처리 양상)

  • Jang, Hyun Min;Choi, Suk Soon;Ha, Jeong Hyub;Park, Jong Moon
    • Applied Chemistry for Engineering
    • /
    • v.24 no.3
    • /
    • pp.279-284
    • /
    • 2013
  • In this study, the feasibility of a single-stage thermophilic aerobic process for the treatment of high-strength food wastewater produced from the recycling process of food wastes was examined to substitute anaerobic digestion process. Also, the removal and stability of thermophilic aerobic process were assessed according to the changes of hydraulic retention times (HRTs) and organic loading rates (OLRs). When the OLR increased from 9.2 to $37.2kgCOD/m^3d$, a pH value in R1 (HRT : 5 d) significantly decreased to 5.0, due to the organic acid accumulation. On the other hand, the pH value in R2 (HRT : 10 d) was stable and R2 showed the high removal of COD, organic acid and lipid, even though the OLR increased from 4.6 to $18.6kgCOD/m^3d$. In R1, the COD loading rates for COD removal was suddenly dropped, as the COD loading rate increased from 18.6 to $28.4kgCOD/m^3d$. In contrast, R2 showed that the COD loading rates for COD removal increased with regard to increment in the loading rates of 3.61, 7.05, 9.43 and $12.2kgCOD/m^3d$, indicative of the high COD removal efficiency. Therefore, the results demonstrated that over 10-d HRT, the high concentration of raw food wastewater was efficiently treated in the single-stage thermophilic aerobic process.

Effect of Calcium Sources for the Treatment of Wastewater Containing High Fluoride (고농도의 불소함유폐수 처리시 칼슘원에 따른 영향)

  • Kim, Seung-Ha;Kim, Keum-Yong;Ryu, Hong-Duck;Lee, Sang-Ill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.5
    • /
    • pp.307-313
    • /
    • 2011
  • As production of LCD increases, it has become necessary to find an economically efficient way of treating LCD wastewater with high concentration of fluoride. This study focuses on the calcium sources : $CaCl_2$, $Ca(OH)_2$ and $CaCO_3$ for the treatment of the LCD wastewater including high concentration of fluoride. Of course considering removal efficiency and economical aspect, study is continued. Then this study have objective giving aid to field. Consequently, each calcium source's removal efficiency was measured in various pH, calcium dosage, reaction time, and mixing intensity. The optimum operational conditions for $CaCl_2$ were found to be pH of 7, calcium dosage of 0.4[Ca]/[F] (mol / mol), 1 hr of operation and 200 rpm of mixing intensity. For $Ca(OH)_2$, they were pH of 7, calcium dosage of 30 mL/L, 1 hr of operation, and 200 rpm of mixing intensity. While $CaCO_3$ had operational conditions of pH of 4, calcium dosage of 30 mL/L, 1 hr operation and 200 rpm of mixing intensity. But it is recommended to use calcium sources according to various field conditions.