• Title/Summary/Keyword: 계획 지표

Search Result 1,081, Processing Time 0.034 seconds

A Proposal for Promotion of Research Activities by Analysis of KOSEF's Basic Research Supports in Agricultural Sciences (한국과학재단의 농수산분야 기초연구지원 추이분석을 통한 연구활동지원 활성화 제언)

  • Min, Tae-Sun;Choi, Hyung-Kyoon;Kim, Seong-Yong;Bai, Sung-Chul;Kim, Yoo-Yong;Yang, Moon-Sik;Chung, Bong-Hyun;Hwang, Joon-Young;Han, In-Kyu
    • Applied Biological Chemistry
    • /
    • v.48 no.1
    • /
    • pp.23-33
    • /
    • 2005
  • Agricultural sciences field in South Korea has many strong points such as numerous researchers, establishment of research infra-structure, excellence in research competitiveness and high technological level. However, there are also many weaknesses including insufficient leadership at related societies and institutes, deficiency of the next generation research group, and insufficiency in research productivity. There are many opportunities including increasing the importance of the biotechnological industry, activating international cooperation researches, and exploring the multitude of possible research areas to be studied. However, some threats still exist, such as pressure from the government of developed countries to open the agricultural market, the decrease of specialized farms, and intensification for researches to gratify economic and social demands. To encourage research activities in the agricultural sciences field in Korea, the following actions and systems are required: 1) formulation of a mid- and a long-term research master plan, 2) development of a database on the man power in related fields, 3) activation of top-down research topics, and associated increase of individual research grants, 4) development of special national programs for basic researches in agricultural sciences, 5) organization of a committee for policy and planning within the related societies, and 6) system development for the fair evaluation of the research results.

Research on the Loss of Irrigation Water Flowing in the Earth Channel (흙 수로내에서의 용수손실에 관한 연구)

  • 김철회
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.14 no.3
    • /
    • pp.2703-2715
    • /
    • 1972
  • 1. Title of Research Research on the Loss of Irrigation Water Flowing in Earth Channel. 2. Purpose and Importance of Research The purpose of this research is to obtain the accurate loss rated of irrigation water flowing in earth channels so as to give a criterion of designing rational and effective suplpy project of irrigations water. It is the present status that the loss rates of 10 to 20% are obscurely applied without any scientific proof. Therefore, the importance of this research lies in securing loss rates, which are experimentally proves to be suitable for specific local conditions. 3. Content and Scope of Research The selected test reach of the main channel is 1,000m long. Discharges were measured at up and downstream enps by using current meter. The test reach of the lateral channel is 500m long, and parshall flumes were set at both ends to measure inflow and outflow. Finally, for the supply ditch, the test section is 200m long, and sharp-edged rectangular weirs were provided at both ends to measure inflow and outflow. In addition, various factors influence on the loss of irrigation water in channel wer examined. 4. Results of Research and Proposition Results: 1. In the main channel, which is 1,000 M long, and has a slope of 1/3,000 and was constructed by cutting earth, its loss rate is 9.64%. 2. In the lateral, which has a slope of 1/1,500, and is 500m long, and was constructed by cutting, its loss rate is 15.55%. Its average seepage rate is 2.08cm/day. 3. In the supply ditch, which has a slope of 1/300, and is 200m long, and was constructed by filling earth, its loss rate is 12.34%, its average seepage rate being 3.37cm/day. Proposition: As could be seen in the results above-mentioned, it is contradictory to apply a loss rate of 20% for every main channels and 15% for every laterals without variation, as done so for in planning irrigation project. The fact, however, is that loss rates must be different according to localities and characteristics. Due to the fact that this experiment is small in its scope and is nothing but a preliminary one, it is hardly possible to draw decisive conclusions with the results obtained in this research. Loss rates, that are secured through more extensive research, should be used, in order to establish precise irrigation project. Moreover, such researches should be carried out for a number of loclities throughout the nation.

  • PDF

Evaluation of the accuracy of the HexaPOD evo RT system using Non-coplanar beams in lung cancer (폐암환자의 비동일평면 선속 빔 치료 시 HexaPOD evo RT system 의 정확성 평가)

  • Jang, Sewuk;cho, Kangchul;Lee, Sangkyoo;Kim, Jooho;Cho, Jeonghee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2015
  • Purpose : The aim of this study, evaluate the accuracy of HeaxPOD evo RT system using the non-coplanar beam. Materials and Methods : 13 treatment plans are used which applied non-coplanar beams and 10 treatment plans which coplanar beams are used. the correction value what adjust to 6D couch is determined by each patient's setup errors only rotation direction. The study executed followings. first, Applying the correction value, measure the point dose and calculate the ${\gamma}$-index(${\gamma}=3%$ / 3 mm, ${\gamma}=2%$ / 2 mm). second, acquire data as previous methods without correction by HexaPOD. Results : For comparing the two results, we find out the more precise applying HexaPOD by point dose 0.2% in coplanar and non-coplanar. in the case of ${\gamma}$-index<1(${\gamma}=3%$ / 3 mm), more precise 2.2% in coplanar and 7% in Non-coplanar. Particularly, ${\gamma}$-index<1(2% / 2 mm) show the difference 9.2% in coplanar and 15.1% non-coplanar between apply HexaPOD and dose not apply HexaPOD. Conclusion : Using the HexaPOD is more precise than without HexaPOD. It suggests that HexaPOD evo RT system is very useful for precise and high dose delivery.

  • PDF

Quality Assurance of Volumetric Modulated Arc Therapy for Elekta Synergy (Elekta Synergy 선형가속기를 이용한 입체적세기조절회전방사선치료(VMAT) 정도관리)

  • Shim, Su-Jung;Shim, Jang-Bo;Lee, Sang-Hoon;Min, Chul-Kee;Cho, Kwang-Hwan;Shin, Dong-Oh;Choi, Jin-Ho;Park, Sung-Ill;Cho, Sam-Ju
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.33-41
    • /
    • 2012
  • For applying the quality assurance (QA) of volumetric modulated arc therapy (VMAT) introduced in Eulji Hospital, we classify it into three different QA steps, treatment planning QA, pretreatment delivering QA, and treatment verifying QA. These steps are based on the existing intensity modulated radiation therapy (IMRT) QA that is currently used in our hospital. In each QA step, the evaluated items that are from QA program are configured and documented. In this study, QA program is not only applied to actual patient treatment, but also evaluated to establish a reference of clinical acceptance in pretreatment delivering QA. As a result, the confidence limits (CLs) in the measurements for the high-dose and low-dose regions are similar to the conventional IMRT level, and the clinical acceptance references in our hospital are determined to be 3 to 5% for the high-dose and the low-dose regions, respectively. Due to the characteristics of VMAT, evaluation of the intensity map was carried out using an ArcCheck device that was able to measure the intensity map in all directions, $360^{\circ}$. With a couple of dosimetric devices, the gamma index was evaluated and analyzed. The results were similar to the result of individual intensity maps in IMRT. Mapcheck, which is a 2-dimensional (2D) array device, was used to display the isodose distributions and gave very excellent local CL results. Thus, in our hospital, the acceptance references used in practical clinical application for the intensity maps of $360^{\circ}$ directions and the coronal isodose distributions were determined to be 93% and 95%, respectively. To reduce arbitrary uncertainties and system errors, we had to evaluate the local CLs by using a phantom and to cooperate with multiple organizations to participate in this evaluation. In addition, we had to evaluate the local CLs by dividing them into different sections about the patient treatment points in practical clinics.

Study of Scatter Influence of kV-Conebeam CT Based Calculation for Pelvic Radiotherapy (골반 방사선 치료에서 산란이 kV-Conebeam CT 영상 기반의 선량계산에 미치는 영향에 대한 연구)

  • Yoon, KyoungJun;Kwak, Jungwon;Cho, Byungchul;Kim, YoungSeok;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.1
    • /
    • pp.37-45
    • /
    • 2014
  • The accuracy and uniformity of CT numbers are the main causes of radiation dose calculation error. Especially, for the dose calculation based on kV-Cone Beam Computed Tomography (CBCT) image, the scatter affecting the CT number is known to be quite different by the object sizes, densities, exposure conditions, and so on. In this study, the scatter impact on the CBCT based dose calculation was evaluated to provide the optimal condition minimizing the error. The CBCT images was acquired under three scatter conditions ("Under-scatter", "Over-scatter", and "Full-scatter") by adjusting amount of scatter materials around a electron density phantom (CIRS062, Tissue Simulation Technology, Norfolk, VA, USA). The CT number uniformities of CBCT images for water-equivalent materials of the phantom were assessed, and the location dependency, either "inner" or "outer" parts of the phantom, was also evaluated. The electron density correction curves were derived from CBCT images of the electron density phantom in each scatter condition. The electron density correction curves were applied to calculate the CBCT based doses, which were compared with the dose based on Fan Beam Computed Tomography (FBCT). Also, 5 prostate IMRT cases were enrolled to assess the accuracy of dose based on CBCT images using gamma index analysis and relative dose differences. As the CT number histogram of phantom CBCT images for water equivalent materials was fitted with a gaussian function, the FHWM (146 HU) for "Full-scatter" condition was the smallest among the FHWM for the three conditions (685 HU for "under scatter" and 264 HU for "over scatter"). Also, the variance of CT numbers was the smallest for the same ingredients located in the center and periphery of the phantom in the "Full-scatter" condition. The dose distributions calculated with FBCT and CBCT images compared in a gamma index evaluation of 1%/3 mm criteria and in the dose difference. With the electron density correction acquired in the same scatter condition, the CBCT based dose calculations tended to be the most accurate. In 5 prostate cases in which the mean equivalent diameter was 27.2 cm, the averaged gamma pass rate was 98% and the dose difference confirmed to be less than 2% (average 0.2%, ranged from -1.3% to 1.6%) with the electron density correction of the "Full-scatter" condition. The accuracy of CBCT based dose calculation could be confirmed that closely related to the CT number uniformity and to the similarity of the scatter conditions for the electron density correction curve and CBCT image. In pelvic cases, the most accurate dose calculation was achievable in the application of the electron density curves of the "Full-scatter" condition.

Three dimensional GPR survey for the exploration of old remains at Buyeo area (부여지역 유적지 발굴을 위한 3차원 GPR 탐사)

  • Kim Jung-Bo;Son Jeong-Sul;Yi Myeong-Jong;Lim Seong-Keun;Cho Seong-Jun;Jeong Ji-Min;Park Sam-Gyu
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.49-69
    • /
    • 2004
  • One of the important roles of geophysical exploration in archeological survey may be to provide the subsurface information for effective and systematic excavations of historical remains. Ground Penetrating Radar (GPA) can give us images of shallow subsurface structure with high resolution and is regarded as a useful and important technology in archeological exploration. Since the buried cultural relics are the three-dimensional (3-D) objects in nature, the 3-D or areal survey is more desirable in archeological exploration. 3-D GPR survey based on the very dense data in principle, however, might need much higher cost and longer time of exploration than the other geophysical methods, thus it could have not been applied to the wide area exploration as one of routine procedures. Therefore, it is important to develop an effective way of 3-D GPR survey. In this study, we applied 3-D GPR method to investigate the possible historical remains of Baekje Kingdom at Gatap-Ri, Buyeo city, prior to the excavation. The principal purpose of the investigation was to provide the subsurface images of high resolution for the excavation of the surveyed area. Besides this, another purpose was to investigate the applicability and effectiveness of the continuous data acquisition system which was newly devised for the archeological investigation. The system consists of two sets of GPR antennas and the precise measurement device tracking the path of GPR antenna movement automatically and continuously Besides this hardware system, we adopted a concept of data acquisition that the data were acquired arbitrary not along the pre-established profile lines, because establishing the many profile lines itself would make the field work much longer, which results in the higher cost of field work. Owing to the newly devised system, we could acquire 3-D GPR data of an wide area over about $17,000 m^2$ as a result of the just two-days field work. Although the 3-D GPR data were gathered randomly not along the pre-established profile lines, we could have the 3-D images with high resolution showing many distinctive anomalies which could be interpreted as old agricultural lands, waterways, and artificial structures or remains. This case history led us to the conclusion that 3-D GPR method can be used easily not only to examine a small anomalous area but also to investigate the wider region of archeological interests. We expect that the 3-D GPR method will be applied as a one of standard exploration procedures to the exploration of historical remains in Korea in the near future.

  • PDF

Changes in Transpiration Rates and Growth of Cucumber and Tomato Scions and Rootstocks Grown Under Different Light Intensity Conditions in a Closed Transplant Production System (식물공장형육묘시스템 내 광량에 따른 오이와 토마토 접수 및 대목의 증발산량 및 생육 변화)

  • Park, Seon Woo;An, Sewoong;Kwack, Yurina
    • Journal of Bio-Environment Control
    • /
    • v.29 no.4
    • /
    • pp.399-405
    • /
    • 2020
  • Recently, it is difficult to produce uniform scions and rootstocks with high quality in a greenhouse due to weather extremes. The closed transplant production system is useful for producing scions and rootstocks with desirable morphological characteristics by environment control regardless of weather outside. In this study, we investigated transpiration rates and growth of cucumber and tomato scions and rootstocks grown under different light intensity conditions for precise irrigation control in a closed transplant production system. Hanging system to measure continuously the weight of plug tray consisting of seedlings and substrate with load-cell was installed in each growing bed. Using this system, we confirmed initial wilting point of cucumber and tomato seedlings, and conducted subirrigation when moisture content of substrate was not below 50%. The irrigation time of cucumber scions and rootstocks were 7 and 6 days after sowing, respectively. In tomato scions and rootstocks grown under PPF (photosynthetic photon flux) 300 μmol·m-2·s-1, the irrigation time were 5, 8, 11, and 13 days after sowing. Increasing light intensity increased transpiration rates and differences of transpiration rates by light intensity was higher in tomato seedlings. The growth of cucumber and tomato seedlings was promoted by increasing light intensity, especially, hypocotyl elongation and stem thickening was affected by light intensity. Cumulative transpiration rate of plug tray in cucumber and tomato seedlings was increased by increasing light intensity, and daily transpiration rate per seedling was regressed by 1st-order linear equation with high correlation coefficient. Estimation of transpiration rates by weighing continuously plug tray of vegetable seedlings can be useful to control more accurately irrigation schedule in a closed transplant production system.

A study on an evaluation model for industrial information systems by industry sectors (업종별 특성을 고려한 기업정보화 성숙모형)

  • 진경수;임춘성;박찬권
    • Proceedings of the CALSEC Conference
    • /
    • 2002.01a
    • /
    • pp.86-106
    • /
    • 2002
  • Informatization is a process that corporation's external environmental factors and internal environmental factors influence as complex. is a phenomenon that appears via this process. To evaluate that informatization was propeled well or informatization level is high can be dangerous work extremely by only once-over-lightly some factors, organization information ability is superior or infrastructure is constructed well. Therefore, an evaluation for industrial information systems that consider corporation's external environment and internal environment configurationally and objective estimation through this is required in national dimension. This research sorted types of business using types of business classification of 2001 EIII(Evaluation Indices of Industrial Informatization) laying stress on corporation's product and product production process for reflecting various industrial classification. And we are dividing whole our country corporations by manufacture industry, the construction industry, distribution industry, service industry, banking industry 5 types of business. To see such classed types industry classification from consistent viewpoint, we saw them within new framework, purchase, operation, physical distribution, marketing and sale. service etc. laying stress on primary businesses except support businesses of planning, financial management etc. To draw special quality of business center from primary business of each types of business, we draw industry classification Key Capability that centers when plans corporation's corporate strategy and information strategy. And we deducted industrial classification key production business connected with industry classification Key Capability. After drawing an evaluation items for industrial information systems in informatization analysis viewpoint laying stress on drawn businesses. Finally we did Case Study by making out an evaluation for industrial information systems questionnaire that considers special quality of manufacturing industry. Through EIII that consider the industrial classification, we could know that it explains the corporation's purchase, production, distribution in general and detail.

  • PDF

Monitoring of Restaurant Beef Labeling System (음식점 식육 원산지 표시 모니터링)

  • Hong, Jin;Leem, Dong-Gil;Kim, Mi-Gyeong;Park, Kyoung-Sik;Yoon, Tae-Hyung;No, Ki-Mi;Jeong, Ja-Young
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.2
    • /
    • pp.162-169
    • /
    • 2010
  • The compulsory beef labelling system has launched from January 1st 2007 by the amended Food Hygiene Law, we were checked the actual conditions of beef origin with a nationwide scale by the Hanwoo differentiation specific test method which was developed by Korea FDA using 90 SNP biomarkers. The test method is useful tool to differentiate the beef origin carrying out the mission of KFDA's annual food safety management guidance. Also we have technically transferred the Hanwoo differentiation specific test method to other institutes as well regional KFDA and established the training program as a regular course in Korea Human Resource Development Institute for Health and Welfare. The beef used in this study were collected according to the 2009 Food safety guidance in roast beef restaurants where business site area greater than 100 $m^2$. Total 216 samples were consisted of 48 samples of the Seoul area and 168 of the region. The monitoring result from restaurants in all the region of Korea showed that 3 of 216 Hanwoo-labelled beefs were found out as a non-Hanwoo (1.3%). This results are gradually deceasing trend compared with 34.0% in 2005, 30.1% in 2006, 3.2% in 2007 and 5.14% in 2008. From these data, the Hanwoo differentiation specific test method on the settlement of the compulsory beef labelling system has an important role. As a outcome of this project, we might be considered the early settlement of the compulsory beef labelling system, technically transferred to other institutes and the establishment of regular training program of the test method.

A Study on the ICAO international aviation safety policy, a change of paradigm and the government response to the direction (ICAO 국제항공안전정책 패러다임의 변화 분석과 우리나라 신국제항공안전정책 검토)

  • Chang, Man-Heui;Hwang, Ho-Won
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.28 no.1
    • /
    • pp.73-96
    • /
    • 2013
  • ICAO's Universal Safety Oversight Audit Programme (USOAP) was initially launched in January 1995, in response to widespread concerns about the adequacy of aviation safety oversight around the world. The recent reduction in aircraft accidents and effective role that is evaluated on the basis of these results, and in 2013 the existing 'snapshot approach' to 'regular monitoring system (USOAP-Continuous Monitoring Approach)' was converted to. ICAO aviation safety assessment of the state in today's international community 'aviation safety credibility' as objective indicators to judge the enormous impact on the aviation industry, the state is not satisfactory, especially if the results of the evaluation and expansion of code-share airline ban, reduced international air transit passengers, including premium increases business and economic penalties should. In addition, ICAO implementation of the existing laws and regulations(Prescriptive Approach), but based on the Risk-based prevention model, Proactive Approach introduced the concept of aviation safety system, including international aviation safety policy has been to switch paradigms. This new ICAO international aviation safety policy also applies to the Government of the Republic of Korea in line with the aviation safey policies have changed. In particular, the systematic implementation of safety management for the existing laws and regulations in the center of the safety oversight system of risk-based introduction of the concept of proactive safety management, and According to international standards ICAO aviation service providers operate their own Safety Management System was set out in Aviation Law ever. In addition, the aviation safety is at the center of the field of the safety of aircraft operations and maintenance for the promotion is promoting various safety policies. This new paradigm shift in the international aviation safety policy in line with our state in the international community with the most exemplary aviation safety system firmly established itself as a model, the Government will strengthen the competitiveness of our aviation plans to support. To do this, the government, airlines, aviation officials try all the practical effect would be expected.

  • PDF