• Title/Summary/Keyword: 계수도법

Search Result 103, Processing Time 0.021 seconds

Target Reliability Indices of Static Design Methods for Driven Steel Pipe Piles in Korea (국내 항타강관말뚝 설계법의 목표 신뢰도지수)

  • Kwak, Kiseok;Huh, Jungwon;Kim, Kyung Jun;Park, Jae Hyun;Lee, Juhyung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1C
    • /
    • pp.19-29
    • /
    • 2008
  • As a part of study to develop LRFD (Load and Resistance Factor Design) codes for foundation structures in Korea, reliability analyses for driven steel pipe piles are performed and the target reliability indices are selected carefully. The 58 data sets of static load tests and soil property tests conducted in the whole domestic area were collected and analyzed to determine the representative bearing capacities of the piles. The static bearing capacity formula and the Meyerhof method using N values are applied to calculate the expected design bearing capacity of the piles. The resistance bias factors were evaluated for the two static design methods by comparing the representative bearing capacities with the design values. Reliability analysis was performed by two types of advanced methods: First Order Reliability Method (FORM), and Monte Carlo Simulation (MCS) method using resistance bias factor statistics. The static bearing capacity formula exhibited relatively small variation, whereas the Meyerhof method showed relatively high inherent conservatism in the resistance bias factors. Reliability indices for safety factors in the range of 3 to 5 were evaluated respectively as 1.50~2.89 and 1.61~2.72 for both of the static bearing capacity formula and the Meyerhof method. The target reliability indices are selected as 2.0 and 2.33 for group pile case and 2.5 for single pile case, based on the reliability level of the current design practice and considering redundancy of pile group, acceptable risk level, construction quality control, and significance of individual structure.

An Auto-tuning of PID Controller using Fuzzy Performance Measure and Neural Network for Equipment System (전력설비시스템을 위한 퍼지 평가함수와 신경회로망을 사용한 PID제어기의 자동동조)

  • 이수흠;박현태;이내일
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.63-70
    • /
    • 1999
  • This paper is proposed a new method to deal with the optimized auto-tuning for the Pill controller which is used to the process-control in various fields. First of all, in this method, 1st order delay system with dead time which is modelled from the unit step response of the system is Pade-approximated, then initial values are determined by the Ziegler-Nichols method. So we can find the parameters of Pill controller so as to minimize the fuzzy criterion function which includes the maximum overshoot, damping ratio, rising time and settling time. Finally, after studying the parameters of Pill controller by Backpropagation of Neural-Network, when we give new K, L, T values to Neural-Network, the optimized parameter of Pill controller is found by Neural-Network Program.rogram.

  • PDF

Development and Identification of Pneumatic Excavator System (모형 공압굴삭기 시스템 구축)

  • Lee, Hong-Sun;Cheon, Se-Young;Lim, Tae-Hyeong;Kim, Sung-Su;Choi, Jeong-Ju;Yang, Soon-Young
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.3
    • /
    • pp.31-36
    • /
    • 2007
  • The excavator is complex machinery which has widely used in the construction site, deck of harbor and deep sea. The one of important issue of excavator system in recent is an automation of it in order to improve a working efficiency, a convenience working circumstance and work satisfaction. However, since there are large nonlinearities of control circuit, actuating cylinder, joiners of hydraulic units and changing loads etc., it is difficult to develope an automatic excavator system. Therefore, in this study, toy scale pneumatic excavator system is constructed and the remote control system is installed on it, before developing the automatic excavator system. In order to design the control system of the developed pneumatic excavator system, the transfer function is obtained using signal processing method and the controller gains of PID are decided based on CDM(coefficient diagram method). The obtained transfer function and the performance of the proposed control system is evaluated through experiments and computer simulation.

Properties and antialopecic effect of eugenol-cinnamic acid derivative

  • Joon su Shin;Kim, Jong-Ho;Park, Jeong-Hwa;Son, Yeu-Dong;Park, Hyeung-Geun;Kim, Bak-kwang
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 1997.04a
    • /
    • pp.110-110
    • /
    • 1997
  • 새로운 발모제 개발에 관한 연구의 일환으로 현재 발모제로 쓰여지고 있는 Eugenol에 구충제로 쓰여지고 있는 cinnamic acid를 반응시켜 4-allyl-2-methoxyphenyl cinnamoyl ester(이하 Eucin이라 칭함)을 만들어 물성, 정량법 및 육모작용 등에 관하여 검토하였다. Eucin은 분자식 $C_{19}$ H$_{18}$ O$_3$ (mw : 294), mp 88-90$^{0}$ C인 백색분말로서 클로로포름, 디클로로메탄 등에 녹고, 메탄올에는 약간 녹으며 물 및 핵산에는 불용이었다. Eucin 메탄올용액의 EtOAc:n-Hexane (1:10) 에서의 Rf=0.24였다. 정량법은 흡광광도법 즉 1 - 5 $\times$ $10^{-5}$M Eucin 표준액에 대하여 최대흡광파장 282.4nm에서 각각 흡광도를 측정하여 구한 검량선식은 Y = 2.1709 $\times$ $10^4$X + 0.07725 (상관계수:997)이며, 또한 HPLC법으로 작성한 검량선식은 $Y_{area}$=3.1578 $\times$ $10^{9}$ X - 1.7958 $\times$ $10^3$(상관계수 : 0.9996)로서 양호한 직선성을 나타내었다. 그리고 육모시험결과는 미녹시딜에 비해 다소 떨어지는 모 복원효과를 나타내었으나, 차후 이 물질의 용해도 등을 개선함으로서 더 정화한 결과를 얻을 수 있으리라 사료된다.다.

  • PDF

Similarity of Sampling Sites by Water Quality (수질 관측지점 유사성 측정방법 연구)

  • Kwon, Se-Hyug;Lee, Yo-Sang
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.1
    • /
    • pp.39-45
    • /
    • 2010
  • As the value of environment is increasing, the water quality has been a matter of interest to the nation and people. Research on water quality has been widely studied, but focused on geographical characteristic and river characteristics like inflow, outflow, quantity and speed of water. In this paper, two approaches to measure the similarity of sampling sites by using water quality data are discussed and compared with two-years empirical data of Yongdam-Dam. The existing method has calculated their similarities with principal component scores. The proposed approach in this paper use correlation matrix of water quality related variables and MDS for measuring the similarity, which is shown to be better in the sense of being clustering which is identical to geographical clustering since it can consider the time series pattern of water quality.

Speed Controller Design of 2-Inertia System used Voltage Controlled DC Motor by CDM (계수도법을 이용한 전압제어 직류전동기 2관성 시스템의 속도제어기 설계)

  • 안영주
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.4 no.3
    • /
    • pp.55-60
    • /
    • 2003
  • In the controller design of position or velocity control system, the flexibility of the mechanical system is always the limiting factor to the higher performance. Most mechanical systems coupled with rotary shaft are 2-Inertia systems which are consist of motor and load inertia. These inertias make a torsion In rotary shaft and cause torsional vibration. To suppress vibration, various control strategies have been proposed mainly for controlling 2-inertia system. In this paper, a speed controller design for a 2-inertia system composed of voltage controlled DC motor and load inertia is made by using CDM(coefficient diagram method). First, the 2-inertia system model is derived. Then the CDM is used to design the proper controller. A validity of this approach is confirmed by simulation and experimental results.

  • PDF

Spectrophotometric Determination of Trace Amount of Sulfide by Formation of Iodide and Its Solvent Extraction with Mehtylene Green (요오드이온 생성 및 Methylene Green과의 용매추출에 의한 미량 황이온의 분광광도법 정량)

  • Kam, Sang-Kyu;Kim, Kyung-Youn
    • Analytical Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.261-269
    • /
    • 1994
  • The iodide formed stoichiometrically for sulfide by its oxidation with iodate was extracted as an ion-pair with methylene green into 1,2-dichloroethane and the extract was measured spectrophotometrically at 656nm for the determination of sulfide. Hydrogen sulfide separated from the sample matrix was introduced into a solution containing pH 3.5 acetate buffer and iodate, in which the hydrogen sulfide was completely converted into iodide. A linear calibration graph was obtained over the range $3{\times}10^{-7}{\sim}1.2{\times}10^{-5}M$ sulfide($0.0096{\sim}0.384{\mu}g$ of $S^{2-}/ml$) and the detection limit was $0.0032{\mu}g/ml$. The apparent molar absorptivity and a correlation coefficient(r) were $6.7{\times}10^4L\;mole^{-1}\;cm^{-1}$ and 0.999, respectively. When applied to the stream water samples, the proposed method gave a relative standard deviation of 1.59% at $5{\times}10^{-6}M$ sulfide level.

  • PDF

Spectrophotometric Determination of Scandium(III) with Eriochrome Cyanine R in the Presence of Cetyltrimethylammonium bromide (Cetyltrimethylammonium bromide에서 Eriochrome Cyanine R에 의한 스칸듐(III)의 분광광도법 정량)

  • Cha, Ki-Won;Park, Chan-Il;Kim, Jong-Whon
    • Analytical Science and Technology
    • /
    • v.9 no.2
    • /
    • pp.139-144
    • /
    • 1996
  • The spectrophotometric determination method of scandium with eriochrome cyanine R(ECR) and the composition ratio of the complex were investigated in the presence of surfactants. The absorbance increase and red shift of maximum adsorption wavelength of Sc(III)-ECR complex were observed in cetyltrimethylammonium bromide (CTMAB), but those changes were not observed in the sodium dodecyl sulfate(SDS) and Triton X-100. A volume of 5ml of $1{\times}10^{-3}M$ ECR and 10ml of $2{\times}10^{-4}M$ CTMAB are necessary for the determination of $1{\times}10^{-7}{\sim}3.0{\times}10^{-6}M$ Sc(III) at pH 6.5. The apparent molar absorption coefficient of the Sc(III)-ECR-CTMAB, temary complex at 610nm is $5.6{\times}10^5mol^{-1}cm^{-1}L$ and its detection limit is $1.0{\times}10^{-7}M$. The binary complex composition of Sc(III)-ECR is 1:2 and the ternary complex composition of Sc(III)-ECR-CTMAB is 1:3:1.

  • PDF

Determination of Trace Amounts of Zirconium by Flotation - Spectrophotometric Method (부유 - 분광광도법에 의한 지르코늄의 극미량 측정)

  • Pourreza, N.;Parham, H.;Shiri, S.
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.3
    • /
    • pp.283-286
    • /
    • 2010
  • A sensitive and reproducible method for the flotation-spectrophotometric determination of zirconium is reported. The method is based on the complex formation zirconium and xylenol orange (XO) which is floated in the interface of aqueous phase and n-hexane by vigorous shaking. By discarding the aqueous solution and n-hexane, the adsorbed complex on to the wall of a separating funnel was dissolved in a small volume of methanol solvent and its absorbance was measured at 429 nm. The effect of different parameters such as pH, concentrations of HCl, and XO, and volume of n-hexane flotation dissolvent, standing and shaking time were studied. The calibration curve was linear in the range of 7-120 ng $mL^{-1}$ of zirconium with a correlation coefficient of 0.9991. The limit of detection (LOD) was 5.8 ng $mL^{-1}$. The relative standard deviation (RSD) for seven replicate measurements of 50 and 110 ng $mL^{-1}$ of zirconium were 4.4 and 3.0%, respectively. The method was successfully applied to the determination of zirconium in water samples.

Determination of Phenobarbital in Intact Phenobabital Tablets using NIRS (근적외선 분광광도법을 이용한 페노바르비탈정제의 정량법에 관한 연구)

  • Cha, Ki-Won;Ze, Keum Ryon;Youn, Mi Ok;Lee, Su Jung;Choi, Hyun Cheol;Kim, Ho Jung;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.102-107
    • /
    • 2002
  • This paper describes a rapid determination of phenobarbital in intact phenobarbital tablets using partial least squares regression(PLSR) method of transmittance spectrum of near infrared (NIR) compared with the analytical data of liquid chromatograpy. The linearity, concentration range and precision of this analytical method are studied. The correlation coefficient of the calibration curve is 0.9983 and the standard error of calibration(SEC) is 0.14 %. Intra-day precision and Inter-day precision obtained in this method are CV = 0.45, CV =0.56, respectively.