• Title/Summary/Keyword: 경사효과

Search Result 833, Processing Time 0.031 seconds

Effect of Positive Pressure Ventilator Tilting Angle on the Flame Suppression and Smoke Density (Positive Pressure Ventilator 경사각 변화에 의한 화염억제 효율과 연기농도 변화)

  • Kim, Sung-Won;Lee, Kyoung-Duck;Shin, Chang-Sub
    • Fire Science and Engineering
    • /
    • v.20 no.4 s.64
    • /
    • pp.135-142
    • /
    • 2006
  • The experiment applied Positive Pressure Ventilation to rapidly exhaust heat and smoke inside the construction in the fire was done. Changes of heat discharge and smoke density were measured, with the various blowing condition like a fan tilting angle to find the effect of the parameter. Experimental apparatus were with PPV and water mist system for better efficiency, and investigate the effect of heat discharge and smoke removal. In the experiment, flame temperature has decreased when PPV was applied. Smoke density, generated from fire also decreased dramatically and the efficiency showed the highest rate at $0^{\circ}$ tilting angle. In addition, combination of PPV and water mist system highly improved the efficiency of evacuation on heat and smoke density, clearly was influenced by the tilting angle.

Vision Algorithm for Forward Collision Warning and Avoidance System (종방향 충돌 경보 및 회피 시스템을 위한 비젼 알고리듬)

  • 엄재원;배재욱;송병석;최태영
    • Proceedings of the IEEK Conference
    • /
    • 2000.09a
    • /
    • pp.897-900
    • /
    • 2000
  • 본 논문에서는 종방향 충돌경보 및 회피시스템(FCWA ; forward collision warning and avoidance)의 일환으로 가변적인 경사도를 가지는 고속도로상의 차선, 차량, 그리고 도로의 곡률을 효과적으로 검출할 수 있는 알고리듬을 제안하였다. 먼저 2D 영상좌표계에 나타나는 투영효과를 제거하기 위한 역투영(IPM; inverse perspective mapping)기법을 소개하였다. 또한 IPM과 필터로부터 차선과 차량을 효과적으로 검출할 수 있는 알고리듬을 소개하였다. 마지막으로 경사가 있는 실제도로영상에 대한 IMP의 수정된 파라미터 보정에 대한 개념 및 실제도로의 곡률 검출을 위한 기하학적 함수 추정기법을 설명하였다 실험결과 제안한 알고리듬이 실제도로영상에서 차선, 차량, 그리고 곡률의 검출에 효과적임을 확인할 수 있었다.

  • PDF

Analysis on Wave Pressure Reduction due to a Slit Capping (슬릿상부공에 의한 파력 감소 분석)

  • Shin, Dong-Min;Ha, Tae-Min;Cho, Yong-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.108.2-108.2
    • /
    • 2010
  • 최근 지역어민 또는 관광객들이 친수공간으로 이용할 수 있는 경사식 상부공의 시공이 많아지고 있다. 경사식 상부공은 수평파력을 저감하는 동시에 사면벽에 작용하는 파력을 제체의 안정에 이용할 수 있다. 그러나 직립식 상부공과 비교하여 전달파고가 커지는 문제점을 가지고 있다. 본 연구에서는 상부공에 슬릿을 주어 슬릿 유무에 따른 파력 감소에 대한 수치모의를 실시하였다. 수치모의에는 범용성이 높은 단면 2차원 해석모델인 수치파동수로(CADMAS-SURF)를 사용하였고, 입사파랑으로는 규칙파를 조파하였으며, 전면불투과벽, 슬릿부, 유수실 바닥, 유수실 후벽에서 파력을 측정하였다. 수치모의 결과 상부공에 슬릿이 있는 경우 뚜렷한 파력 감소 효과를 보였으며, 파력감소 효과로 인하여 케이슨의 중량을 줄일 수 있어 공사비 절감 효과도 기대할 수 있었다.

  • PDF

Characteristics of Soil Erosion on the Forest Fired Sites by Using Rainfall Simulator (인공강우장치를 이용한 산불발생지의 토양침식 특성에 관한 연구)

  • Lee, Heon Ho;Joo, Jae Duk
    • Journal of Korean Society of Forest Science
    • /
    • v.95 no.6
    • /
    • pp.649-656
    • /
    • 2006
  • The purpose of study is to measure soil erosion quantity for elapsed four years from the fire on forest fired sites of Dong-gu, Daegu. This study was conducted to investigate the characteristics of soil erosion by fire occurrence influencing on the soil erosion were. Also analysis result follows that the relations between soil erosion quantity and rainfall intensity, the slope and elapsed year. The results analysed were as follows: 1. Soil erosion by year of occurrence of forest fire was increased 1.9 to 5.7 times as rainfall intensity was increased by 30 m/hr, and 1.4 to 14.2% as degree of slope was increased by $10^{\circ}$. 2. In the first year of forest fire occurrence, soil erosion was fairly heavy for 10 minutes of initial rainfall of which rainfall intensity was 80 m/hr and degree of slope was $30^{\circ}$. The amount of soil erosion was gradually reduced as elapsed time. From two years after fire, the amount of soil erosion by rainfall intensity and degree of slope was nearly constant. 3. The amount of soil erosion by rainfall intensity and slope in accordance with elapsed time after fire was reduced 28.9 to 94.1% in three years after occurrence of forest fire as compared to the first year of fire. Soil erosion was fairly heavy by rainfall intensity and slope in the first year of fire, but it was gradually reduced from two years after fire. 4. In the analysis on influences of each factors on the amount of soil erosion on forest fired sites, the amount of soil erosion was significant differences in major impacts of each rainfall intensity, degree of slope and elapsed year after fire and interaction of rainfall intensity${\times}$degree of slope and rainfall intensity${\times}$elapsed year after fire, but no differences were observed in interaction of degree of slope${\times}$elapsed year after fire and rainfall intensity${\times}$degree of slope${\times}$elapsed year after fire. Rainfall intensity was the most affecting factor on the amount of soil erosion and followed by degree of slope and elapsed year after fire. 5. For correlation between soil erosion and affecting three factors, soil erosion showed significant positive relation with rainfall intensity and degree of slope at I % level, and significant negative relation with elapsed year after fire at 1 % level. 6. As a result of regression of affecting three factors on soil erosion. rainfall intensity was most significant impact factor in explaining the amount of soil erosion on forest fired sites, followed by degree of slope and elapsed year after forest fire. 7. The formula for estimating soil erosion using rainfall intensity, degree of slope and elapsed year after forest fire occurrence was made. S.E = 0.092R.I + 0.211D.S - 0.942E.Y(S.E : Soil erosion, R.I : Rainfall intensity, D.S : Degree of slope, E.Y : Elapsed year after forest fire occurrence)

Flow Induced Vibration and Suppression of Inclined Cylinder (유체유동에 의한 경사원주의 진동과 제진에 관한 연구)

  • 양보석;복정희일랑;암호탁삼
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1381-1390
    • /
    • 1992
  • This paper presents a dynamic characteristics of flow induced vibration of circular cylinder set with inclined angle against flow direction. The effect of the cylinder bounded by spiral fin and wire on the damping of flow induced vibration is investigated, i.e., inclined angle, spiral pitch angle and number of spiral thread are studied. As the results, the cylinder with spiral fin is most effective for the damping. Also the cylinder bounded by pitch angle 50.deg. and 2 spiral thread is most effective.

Effect of reference on the distortion of 3D slant perception of semitransparent motion-induced surface during disjunctive eye movement (원근방향 추적 눈 운동 시 참조자극이 자극운동 유도 표면의 삼차원 경사지각 왜곡에 미치는 효과)

  • 이형철
    • Korean Journal of Cognitive Science
    • /
    • v.14 no.3
    • /
    • pp.51-59
    • /
    • 2003
  • Various perceptual distortions in spatial vision occur during eye movements. Most of the studies on perceptual distortion have focused on the conjunctive eye movements. Recently, Li, Kham, Kim & Yoon (2002) reported that subjects experienced perceptual distortion of 3D slant of an object defined by the spatiotemproal pattern of occlusion. The present research examined whether the subjects experienced the same perceptual distortion in the target object whose luminance is different from that of background. It also examined the effect of the reference on the perceptual distortion of 3D slant of an object.

  • PDF

Flow and Heat Transfer Characteristics on Oblique Impingement Surface by Single Axisymmetric Jet (단일 축대칭제트에 의한 경사충돌면에서 유동 및 열전달 특성)

  • 이창호;황상동;조형희;정학재
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.1
    • /
    • pp.34-40
    • /
    • 1999
  • An experimental study has been conducted to determine the effects of inclined impinging jet on the local heat transfer coefficients. A single jet with nozzle diameter of 24.6 mm was tested for Reynolds numbers from 10,000 to 70,000 and nozzle-to-plate spacings of 2~6 jet diameters. The angle of inclination of the impingement surface relative to the horizontal surface was varied from $0^{\cire}$ (normal impingement) to $60^{\cire}$. The results indicate that the point of maximum heat transfer is moved up from the geometrical stagnation point of inclined surface by Coanda effect. The local heat transfer coefficients on the minor jet region decrease more rapidly than on the major jet region, thus creating an imbalance in the cooling capabilities on the two sides.

  • PDF

Gradient Noise Reduction in EEG Acquired During MRI Scan (MRI와 동시 측정한 뇌전도 신호에서 경사자계 유발잡음의 제거)

  • Lee H.R.;Lee H.N.;Han J.Y.;Park T.S.;Lee S.Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Purpose : Information about electrical activity inside the brain during fMRl scans is very useful in monitoring physiological function of the patient or locating the spatial position of the activated region in the brain. However, many additional noises appear in the EEG signal acquired during the MRI scan. Gradient induced noise is the biggest one among the noises. In this work, we propose a gradient noise reduction method using the independent component analysis (ICA) method. Materials and Methods : We used a 29-channel MR-compatible EEG measurement system and a 3.0 Tesla MRI system. We measured EEG signals on a subject lying inside the magnet during EPI scans. We selectively removed the gradient noise from the measured EEG signal using the ICA method. We compared the results with the ones obtained with conventional averaging method and PCA method. Results : All the noise reduction methods including the averaging and PCA methods were effective in removing the noise in some extent. However, the proposed ICA method was found to be superior to the other methods. Conclusion : Gradient noise in EEG signals acquired during fMRI scans can be effectively reduced by the ICA method. The noise-reduced EEG signal can be used in fMRI studies of epileptic patients or combinatory studies of fMRI and EEG.

  • PDF