• Title/Summary/Keyword: 경부 디자인

Search Result 19, Processing Time 0.021 seconds

Cervical design effect of dental implant on stress distribution in crestal cortical bone studied by finite element analysis (유한요소법을 이용한 임플란트 경부 디자인이 골응력에 미치는 영향 분석)

  • Kim, Kyung-Tak;Jo, Kwang-Heon;Lee, Cheong-Hee;Yu, Won-Jae;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.4
    • /
    • pp.385-393
    • /
    • 2009
  • Statement of problem: High stress concentration on the crestal cortical bone has been regraded as a major etiologic factor jeopardizing long term stability of endosseous implants. Purpose: To investigate if the design characteristics of crestal module, i.e. internal type, external type, and submerged type, affect stress distribution on the crestal cortical bone. Material and methods: A cylindrical shaped implant, 4.3 mm in diameter and 10 mm in length, with 3 different crestal modules, i.e. internal type, external type, and submerged type, were analysed. An axisymmetric scheme was used for finite elment formulation. A vertical load of 50 N and an oblique load of 50N acting at $45^{\circ}$ with the implant's long axis was applied. The peak crestal bone stress acting at the intersection of implant and crestal bone was compared. Results: Under vertical load, the crestal bone stress was high in the order of internal, external, and submerged types. Under the oblique loading condition, it was in the order of internal, submerged, and external types. Conclusion: Crestal module design was found to affect the level of the crestal bone stresses although the actual amount was not significant.

Influence of crestal module design on marginal bone stress around dental implant (임플란트 경부 디자인이 변연골 응력에 미치는 영향)

  • Lim, Jung-Yoel;Cho, Jin-Hyun;Jo, Kwang-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.224-231
    • /
    • 2010
  • Purpose: This study was to investigate how the crestal module design could affect the level of marginal bone stress around dental implant. Materials and methods: A submerged implant of 4.1 mm in diameter and 10 mm in length was selected as baseline model (Dentis Co., Daegu,Korea).A total of 5 experimental implants of different crestal modules were designed (Type I model : with microthread at the cervical 3 mm, Type II model : the same thread pattern as Type I but with a trans-gingival module, Type III model: the same thread pattern as the control model but with a trans-gingival module, Type IV model: one piece system with concave transgingival part, Type V model: equipped with beveled platform). Stress analysis was conducted with the use of axisy mmetric finite element modeling scheme. A force of 100 N was applied at 30 degrees from the implant axis. Results: Stress analysis has shown no stress concentration around the marginal bone for the control model. As compared to the control model, the stress levels of 0.2 mm areas away from the recorded implant were slightly lower in Type I and Type IV models, but higher in Type II, Type III and Type V models. As compared to 15.09 MPa around for the control model, the stress levels were 14.78 MPa, 18.39 MPa, 21.11 MPa, 14.63 MPa, 17.88 MPa in the cases of Type I, II, III, IV and V models. Conclusion: From these results, the conclusion was drawn that the microthread and the concavity with either crestal or trans-gingival modules maybe used in standard size dental implants to reduce marginal bone stress.

The effect of implant system with reverse beveled platform design on marginal bone stress distribution (임플란트 경부의 역사면 디자인이 변연골 응력분포에 미치는 영향)

  • Cha, Ji-Young;Cho, Jin-Hyun;Jo, Kwang-Hun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.266-272
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the effects of the surface morphology of the implant neck on marginal bone stress measured by using finite element analysis in six implant models. Materials and methods: The submerged type rescue implant system (Dentis co., Daegu, Korea) was selected as an experimental model. The implants were divided into six groups whose implant necks were differently designed in terms of height (h, 0.4 and 1.0 mm) and width (platform width, w = 3.34 + 2b [b, 0.2, 0.3 and 0.4 mm]). Finite element models of implant/bone complex were created using an axisymmetric scheme. A load of 100 N was applied to the central node on the top of crown in parallel with the implant axis. The maximum compression stress was calculated and compared. Results: Stress concentration commonly observed around dental implants did not occur in the marginal bone around all six test implant models. Marginal bone stress varied according to the implant neck bevel which had different width and height. The stress was affected more markedly by the difference in height than in width. Conclusion: This result indicates that the implant neck bevel may play an important role in improving stress distribution in the marginal bone area.

Considerations in implant crestal module to preserve peri-implant tissue (임플란트 주위 조직 보존을 위한 임플란트 경부의 디자인에 관한 고찰)

  • Kim, Hong-Jun;Kim, Jee-Hwan;Kim, Sung-Tae;Lee, Jae-Hoon;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.4
    • /
    • pp.346-353
    • /
    • 2011
  • Purpose: The peri-implant soft tissue is remodeled by the initial marginal bone resorption affecting the prognosis and esthetic result of treatment. Thus various designs on implant neck design are studied to preserve peri-implant bone. The purpose of this study is to review on the causes of initial marginal bone resorption, the configuration of peri-implant soft tissue, and the implant crestal module favorable in preserving peri-implant tissue. Materials and methods: The studies on the causes of initial marginal bone resorption and the implant crestal modules are researched and reviewed using Pubmed database. The implant crestal modules including one piece and two-piece implant, internal and external hex abutment, taper and butt joint connection, scalloped design abutment, and platform switching concept are reviewed. Results: A number of clinical and experimental studies preferred one piece implant to two-piece in preserving initial peri-implant tissue. For two piece implants, internal hex abutment and taper joint connection appear more favorable than external hex abutment and butt joint connection relatively. Controversial issues still exist on scalloped design requiring more studies on it. Although the rationale is not certain, the concept of platform switching seems favorable in preserving initial peri-implant tissue based on clinical and experimental studies. Conclusion: Each implant crestal module contains its own advantages and disadvantages with various controversial issues. In the aspect of preservation of initial peri-implant tissue, however, one-piece implant seems beneficial. In cases when two-piece implant is more appropriate due to prosthodontic concerns or any other problems, the application of platform switching concept, internal connection abutment, and taper joint connection may be favorable for the preservation of peri-implant tissues.

Investigation of the Regression Analysis Method for a Quantitative Evaluation of Implant Crestal Bone Stresses (회귀분석법에 의한 임플란트 경부골 응력의 정량적 분석에 대한 연구)

  • Kim, Woo-Shik;Jo, Kwang-Hun;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.3
    • /
    • pp.299-310
    • /
    • 2008
  • In this study, the regression analysis method was tested for the estimation of peak stress at stress concentration area in the cervical bone. Submerge type EZ plus implant (Megagen. Daegu, Korea), 4.1 mm in cervical diameter and 9.6 mm in endosseous length, were axisymmetrically modelled together with surrounding alveolar bone of which the width was 10 mm. Vertical force of 100 N was applied to a head of crown above 8.5 mm from the outer surface of the cortical bone. Four different mesh models were composed of differently sized elements in vicinity of sharp corners, and they include 6 stress monitoring points that are located in the same geometrical points regardless of the differences in the meshes. Primary consideration was given to the stresses in the cortical bone surrounding the implant neck. The results showed that virtually all the stresses were concentrated in the cortical bone regardless of mesh designs. The peak stresses were successfully calculated by a regression analysis in a stable manner, as far as the mesh is designed to represent the acute gradient of stresses near the sharp corner.

The Scenary Design for the Service car of High Speed Train (고속전철 부속실 풍경 디자인)

  • 한송이;이선영;최혁수;이병종;정경렬
    • Proceedings of the Korea Society of Design Studies Conference
    • /
    • 2000.11a
    • /
    • pp.84-85
    • /
    • 2000
  • G7 고속전철개발 산업에서 계획된 부속실은 경부 고속전철(K-TGV)의 부속실을 그대로 사용하는 것으로서 좁은 통로와 획일적 공간, 불필요한 공간에 의한 승객 편의시설의 결여되었기에, 이의 수정보완이 요구되었다. 아래의 사진들은 K-TGV의 부속실 모습이다. (중략)

  • PDF

Influence of microthread design on marginal cortical bone strain developement: A finite element analysis (임플란트 경부 미세나사 디자인이 치밀골의 스트레인에 미치는 영향)

  • Chun, Seung-Geun;Cho, Jin-Hyun;Jo, Kwang-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.215-223
    • /
    • 2010
  • Purpose: The present study was aimed to evaluate the level of cortical bone strain during the placement of an implant. The primary concern was to investigate if the extent of overloading area near the marginal bone could be affected by microthread fabricated at the cervical 1/3 of an implant. Materials and methods: Three dimensional finite element analysis was used to simulate the insertion of 3 implants. Control model was $4.1{\times}10$ mm implant (Submerged model, Dentis Co,, Daegu, Korea) equipped with a main thread only. Type I was with main thread and microthread, and Type II had similar thread pattern but was of tapered body. A PC-based finite element software (DEFORM 3D ver 5, SFTC, Columbus, OH, USA) was used to calculate a total of 3,600 steps of analysis, which simulated the whole insertion. Results: Results showed that the strain field in the marginal bone within 1 mm of the implant wall was higher than 4,000 micro-strain in the control model. The size of bone overloading was 1-1.5 mm in Type I, and greater than 2 mm in Type II implants. Conclusion: These results indicate that the marginal bone may be at the risk of resorption on receiving the implant for all 3 implant models studied. Yet, the risk was greater for Type I and Type II implants, which had microthread at the cervical 1/3.

Korea High Speed Train Design - focused on aerodynamic optimal form design development (한국형 고속전철 디자인 -공기역학적 최적형상 디자인개발을 중심으로-)

  • 이병종
    • Archives of design research
    • /
    • v.17 no.3
    • /
    • pp.123-132
    • /
    • 2004
  • This paper shows a study on the "Korean High Speed Train Design" method, its design process and the result in the form of aerodynamic optimal exterior design development of a prototype test train(HSR 350${\times}$). It was developed from 1996 until 2002, six years long in R '||'&'||' D project titled "Development of High Speed Railway Technology" The end result of the project is a prototype test train, which has two power cars, two motorized trailers and three trailers, had been tested successfully in the year 2003 to the highest speed limit 380km/h on high speed line. The improved conceptual design work of a new commercial train and next generation's train is also performed for future needs.uture needs.

  • PDF

Bidirectional Series Resonant Converter with Soft Switching Capability (소프트 스위칭 기능을 갖춘 양방향 직렬 공진형 컨버터)

  • Park, Hwa-Pyeong;Jung, Jee-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.13-14
    • /
    • 2017
  • 1차와 2차측의 위상 변조를 이용하는 Dual Active Bridge (DAB) 형태의 직렬 공진형 양방향 컨버터는 이미 구현되었다. 하지만 이는 좁은 영전압 스위칭 범위를 가지고 경부하시 전력변환 효율을 떨어뜨린다. 본 논문은 Sinple Phase Shift (SPS)와 Extended Phase Shift (EPS)를 사용하는 양방향 직렬 공진형 컨버터를 제안하고 이를 이용하여 전부하 구간동안 소프트 스위칭을 얻고자 한다. 정방향 및 역방향 전력 변환에 따른 영전압 스위칭의 조건을 분석하고 공진 탱크와 제어 자유도를 조절 방법에 대해 분석하고자 한다. 제안하는 분석 및 디자인 방법은 500 W 직렬 공진형 컨버터를 통해 검증하였다.

  • PDF

A Study on the Formations and Compositions of the Cyber Museum -Focusing on the case of oversea natural history museum- (사이버 뮤지엄의 형식과 구성에 관한 고찰 -자연사 박물관 분야에 대한 해외사례를 중심으로-)

  • 임경부;임채진
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 1999.04a
    • /
    • pp.7-10
    • /
    • 1999
  • The organization of modern society is suddenly changing from the modern society to the ultra modern informationalized society. Various social members must satisfy cultural and artistic desires to serve museum concept and function to move the informationalized society. A lot of natural history museum in the world build cyber space exhibition lines. Audiences do not directly visit but they view but they view the exhibit, get an education, participate in the cultrue programs and earn the museum's informations. Especially, in the case of national and public museums in Korea, they do not concerned the museum architecture before processing the character and collections of the museum. Cyber museums determine museum character, policy, information, collections converge of opinion voluntary collection and grasp of location, because cyber museum can be finished be4fore the work of the future museum.

  • PDF