• Title/Summary/Keyword: 경보기준

Search Result 265, Processing Time 0.025 seconds

Proposal of Early-Warning Criteria for Highway Debris Flow Using Rainfall Frequency (2): Criteria Adjustment and Verification (확률 강우량을 이용한 고속도로 토석류 조기경보기준 제안 (2) : 기준의 조정 및 적용성 검토)

  • Choi, Jaesoon
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.15-24
    • /
    • 2019
  • In the previous study, the rainfall data of 1 hour, 6 hours and 3 days were used as the rainfall criterion according to the grade to trigger the debris flow in the highway area, using the rainfall data of Gangwon area and the rainfall time-series data at the spot where the debris flow occurred. In this study, we propose an early warning criterion of the highway debris flow triggering through appropriate combination of three rainfall criteria selected through previous studies and adjustments of rainfall criterion in the highway debris flow triggering. In addition, simulations were conducted using the time-series rainfall data of 2010~2012, which had a large amount of precipitation for the five sites where debris flows occurred in 2013. As a result of the study, the criteria for the early warning of highway unsteadiness on the highway were prepared. In case of the grade-based adjustment, it is preferable to apply the unified rating to the grade B. Also, if the fatigue of the monitoring is not a problem, adjusting it to A or S may be a way to positively cope with the occurrence of highway debris flow.

IoT-based Smart Tunnel Accident Alert System (사물 인터넷 기반의 스마트 터널 사고 경보 시스템)

  • Ki-Ung Min;Seong-Noh Lee;Yoon-Hwa Choi;Yeon-Taek Hong;Chul-Sun Lee;Yun-Seok Ko
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.4
    • /
    • pp.753-762
    • /
    • 2024
  • Tunnels have limited evacuation areas, and It is difficult for cars coming from behind to recognize the accident situation in front. Since an accident is very likely to lead to a serious secondary accident, a IoT-based smart tunnel accident warning system was studied to prepare for traffic accidents that occur in tunnels. If the measured values from the flame detection sensor, gas detection sensor, and shock detection sensor in the tunnel exceed the standard, it is judged to be an emergency situation and an alert system is designed to operate. The accident information message was designed to be displayed on the LCD and transmitted to drivers inside and outside the tunnel through a Wi-Fi communication network. A performance test system was established and performance evaluation was performed for several accident scenarios. As a result of the test, it was confirmed that the accident alert system can accurately detect accidents based on given reference values, perform alert procedures, and transmit alert messages to smart phones through Wi-Fi wireless communication. And through this, its effectiveness could be confirmed.

Alarm Setpoint Determination Method of Gaseous Effluent Radiation Monitoring Systems Using Dose Factors Based on ICRP-60 Recommendations (선량환산인자를 이용한 기체유출물 RMS 경보설정 개선방안)

  • 박규준;김희근;하각현;엄희문
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.491-496
    • /
    • 2003
  • In Korea, the dose limits to the public were reduced according to ICRP-60 recommendations. The secondary quantities, Effluent Concentration Limits (ECLs) were derived and enacted to Korean Atomic Laws based on ICRP-60 recommendations. The Korea atomic laws require assurance that radioactive materials within gaseous effluents do not exceed dose limits and ECLs. This simply means that any effluent that would possibly contain radioactivity must be monitored. There are various methods to monitor the radioactivity of effluent monitor to satisfy the dose limits and the ECLs for gaseous effluents. The many factors (safety margin) should be considered in determining of the setpoint of effluent monitor, following these limits. In this study, we studied the determination method of alarm setpoint for gaseous effluent Radiation Monitoring Systems using dose factors considered the main pathway of radionuclides to compare the preceding determination method of alarm setpoint for gaseous effluent RMSs using dose assessment program considered all the practicable pathways of radionuclides.

  • PDF

Comparison of Analytical Methods for Ozone Precursors Using GC-MS and GC-FID (오존전구물질 VOC 분석의 분석방법(GC-MS, GC-FID) 간 비교연구)

  • 황승만;허귀석;이재환
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2001.11a
    • /
    • pp.249-250
    • /
    • 2001
  • 최근 대도시 지역에서의 오존농도가 환경기준을 초과하는 빈도가 날로 증가하고 있는 실정이며, 이에 국내의 경우 오존농도 증가에 대비하여 대기 중 오존농도가 일정기준(시간당 0.12 ppm)보다 높게 나타났을 때 신속하게 경보를 발령, 시민들의 건강과 생활환경상의 피해를 최소화하기 위해 오존경보제를 시행해오고 있다. 한편 전세계적으로 대도시 지역에서의 지표면 오존농도가 환경기준을 초과함에 따라 오존생성과 관련된 전구물질(precursor)에 대한 제어과정이 지표면 오존농도의 저감을 실현하기 위한 가장 시급한 과제로 대두되고 있으며, 특히 미국의 경우 1993년부터 광화학평가측정망(Photochemical Assessment Monitoring Stations;PAMS)을 설치하여 이들 물질에 대한 보다 집중적인 모니터링을 실시하고 있는 것으로 알려져 있다. (중략)

  • PDF

Prediction and Reduction of Alarm Sound Propagated through Elevator Shaft (엘리베이터 샤프트를 통한 경보음 전달 예측과 개선)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.89-96
    • /
    • 2019
  • In this study, alarm sound generated as a priority alert system propagation through an elevator shaft in apartment buildings were simulated using room acoustic simulation software. The simulations were conducted on three kinds of elevator hall plan with a different number of elevators and placement. First, the elevator shaft without sound absorption material was simulated as a condition of the present. When the distance from the alarm sound generating floor became farther, alarm sound level was decreased. However, the alarm sound level three-floor distance was about 54 dB(A)~56 dB(A) which were louder than a background sound level of typical apartment buildings. Sound absorption material placement proposed by previous studies were simulated and the alarm sound levels were decreased about 12 dB~16 dB. These levels were similar or lower than the background level of apartment buildings. From these results, it can be concluded that placing sound absorption material on the surface of the elevator shaft wall can be one of the methods to control the alarm sound as regulated in NFSC.

Development of the Low Power Stand-Alone Smoke and Heat Detector for the Reliability Improvement (신뢰성 개선을 위한 저전력 열연 복합식 단독경보형 감지기 개발)

  • Jee, Seung-Wook;Kim, Si-Kuk;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.74-79
    • /
    • 2012
  • This study is described for development of the stand-alone smoke and heat detector (SASHD) according to the revised in 2011 type approval and performance inspection code for detector. The main improvement of the revised regulation is source. CMOS microcontroller with nano watt technology is use for development of the workable SASHD over 10 years. The low-power SASHD is developed by using the power-saving sleep mode of microcontroller, by making the low-power source voltage checker, heat detector and smoke detector. The stand-alone detector is developed by smoke and heat detector type for reduce false fire alarm. User can choose type of work between the heat detection mode and smoke & heat detection mode. The SASHD can communicate with each them using RS-485 communication supported from microcontroller. So, this study can develop the SASHD that is able to alarm more wide area when fire occurs and reduce a flash fire alarm.

Fire Alarm Sound Transmission in Apartment Units (공동주택에서의 화재경보음 전달)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.67-75
    • /
    • 2018
  • To reduce the number of casualties in the case of fire, an alarm sound needs to be delivered to the people who remain in the apartment unit. On the other hand, it was reported that the fire alarm sound generated in the elevator hall was not delivered sufficiently to the people staying in the apartment units. In this study, the background noise level and noise level generated in an apartment unit were measured during the day and night time. In addition, the transmission of the fire alarm sound into the each room of apartment units was simulated and compared with the background noise level. The fire alarm sound generated in the elevator halls was reduced by the fire door and doors, and was not transmitted sufficiently into the internal spaces of the apartment units. Starting evacuation action was difficult after hearing the fire alarm sound generated outside the apartment units. To improve the transmission of an alarm sound to the inner spaces of apartment units, an acoustic simulation was carried out for cases where the alarm sound generator was installed on a wall-pad in the living room and the alarm sound generator was installed on the ceiling of each rooms in apartment units. Background noise of + 15 dB and 75 dB (A) were satisfied when alarm sound generator was installed on the ceiling of each room.

Comparison of the flow estimation methods through GIUH rainfall-runoff model for flood warning system on Banseong stream (반성천 홍수경보 시스템을 위한 GIUH기반 한계홍수량 산정기법 비교연구)

  • Seong, Kiyoung;Ahn, Yujin;Lee, Taesam
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.5
    • /
    • pp.347-354
    • /
    • 2021
  • In the past few years, various damages have occurred in the vicinity of rivers due to flooding. In order to alleviate such flood damage, structural and non-structural measures are being established, and one of the important non-structural measures is to establish a flood warning system. In general, in order to establish a flood warning system, the water level of the flood alarm reference point is set, the critical flow corresponding thereto is calculated, and the warning precipitation amount corresponding to the critical flow is calculated through the Geomorphological Instantaneous Unit Hydrograph (GIUH) rainfall-runoff model. In particular, when calculating the critical flow, various studies have calculated the critical flow through the Manning formula. To compare the adequacy of this, in this study, the critical flow was calculated through the HEC-RAS model and compared with the value obtained from Manning's equation. As a result of the comparison, it was confirmed that the critical flow calculated by the Manning equation adopted excessive alarm precipitation values and lead a very high flow compared to the existing design precipitation. In contrast, the critical flow of HEC-RAS presented an appropriate alarm precipitation value and was found to be appropriate to the annual average alarm standard. From the results of this study, it seems more appropriate to calculate the critical flow through HEC-RAS, rather than through the existing Manning equation, in a situation where various river projects have been conducted resulting that most of the rivers have been surveyed.

Development and application of urban flood alert criteria considering damage records and runoff characteristics (피해이력 및 유역특성을 고려한 도시침수 위험기준 설정 및 적용)

  • Cho, Jeawoong;Bae, Changyeon;Kang, Hoseon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • Recently, localized heavy rainfall has led to increasing flood damage in urban areas such as Gangnam, Seoul ('12), Busan ('13), Ulsan ('16) Incheon and Busan ('17) etc. Urban flooding occurs relatively rapidly compared to flood damage in river basin, and property damage including damage to houses, cars and shopping centers is more serious than facility damage to structures such as levees and small bridges. In Korea, heavy rain warnings are currently announced using the criteria set by KMA (Korea Meteorological Administration). However, these criteria do not reflect regional characteristics and are not suitable to urban flood. So in this study, estimated the flooding limit rainfall amount based on the damage records for Seoul and Ulsan. And for regions that can not estimate the flooding limit rainfall since there is no damage records, we estimated the flooding limit rainfall using a Neuro-Fuzzy model with runoff characteristics. Based on the estimated flooding limit rainfall, the urban flood warning criteria was set. and applied to the actual flood event. As a result of comparing the estimated flooding limit rainfall with the actual flooding limit rainfall, the error of 1.8~20.4% occurred. And evacuation time was analyzed from a minimum of 28 minutes to a maximum of 70 minutes. Therefore, it can be used as a warning criteria in the urban flood.