• Title/Summary/Keyword: 경계면 온도

Search Result 163, Processing Time 0.025 seconds

A Study on the Diluted Water from the Yangtze River in the East China Sea using Satellite Data (위성 자료를 이용한 제주도 주변해역에 나타나는 중국대륙기원 양자강 유출수(저염수)에 관한 연구)

  • Yoon, Hong-Joo;Cho, Han-Keun
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.8 no.4
    • /
    • pp.33-43
    • /
    • 2005
  • China Coastal Waters(CCW) usually appeared from June through October every years, and it appeared very strong in August. In the harmonic analysis for Sea level anomaly (SLA), the annual amplitude of the eastern part (8~9.5cm) in Jeju Island was lower than those of the western part (over 13cm). In the harmonic analysis for Sea Surface Temperature (SST), the annual amplitude of the eastern part($7{\sim}8.5^{\circ}C$) in Jeju Island was lower than those of the western part($5.5{\sim}6^{\circ}C$). For the Power Spectrum Density (PSD), SLA and SST remarkablely peaked on the annual period, semi-annual period and 3-monthly period. In summer and autumn, SLA of 1996 to 1999 was high in comparison to other years, and then it should be considered that the appearance of CCW was closely related to heavy rainfalls. The path of CCW formed this boundary of temperature between the yellow sea and the east china sea.

  • PDF

Development of Axial Power Distribution Monitoring System Using Two-Level Encore Detector (상하부 2개의 노외계측기를 이용한 축방향 출력분포 감시계통 개발)

  • Chi, Sung-Goo;Song, Jae-Woong;Ahn, Dwak-Hwan;Kuh, Jung-Eui
    • Nuclear Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.294-301
    • /
    • 1989
  • The Axial Power Distribution Monitoring System(APDMS) program was developed to calculate a detailed axial power distribution using two-level excore detector, cold leg temperature and control rod position signals. The unnormalized two-level excore detector signals were corrected for the rod shadowing factor determined by control rod position and for the temperature shadowing factor calculated based on cold leg temperature. A shape annealing matrix was then applied to the corrected excore detector response to yield peripheral power. After the core average power was obtained using linear relationship bet-ween core average and peripheral power, the boundary point power correction coefficient was applied to core average power in order to obtain boundary power for both upper and lower core axial boundaries. Then, the axial power distribution was synthesized by spline approximation. In spite of burnup, power level, control rod postion and axial offset changes, the comparisons of axial power distributions between BOXER simulation program and APDMS results showed good agreements within 5% root mean square error for Kori Unit 3 Cycle 4.

  • PDF

냉각수가 비등하지 않는 조건에서 용융물의 피막층 형성에 대한 2차원적 해석

  • 조재선;이병철;정창현;김희동
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.707-712
    • /
    • 1996
  • 중대사고시 원자로 압력용기내 또는 원자로 공동(cavity) 내에서의 노심용융물은 주입되는 물로 인하여 물과 접촉하는 표면이 냉각되면서 피막층(crust)이 형성된다. 이러한 피막층의 형성은 노심용융물과 냉각수 사이의 열전달 현상에 영향을 미치며 중대사고 발생시 사고 진행에 중요한 역할을 한다. 본 연구에서는 이러한 용융물의 피막층 형성의 해석모델을 수립하기 위해 전이현상과 전도와 대류를 포함하는 2차원 열전달과 상변화를 수반하는 문제를 포함하는 운동량방정식과 에너지방정식을 2차원으로 구성하였으며 에너지방정식은 엔탈피의 함수로 나타내었다. 그리고 이러한 2차원 지배방정식을 해석하기 위해 유한차분법 및 SIMPIER 알고리즘을 이용하였다. 비교대상으로는 한국원자력연구소에서 수행한 냉각수의 비등과 기체주입 효과가 고려되지 않은 실험을 대상으로 하였다. 계산결과 용융물의 피막층은 파동(wave) 형태로 형성되었으며 일정시간이 경과하면 변화가 없는 안정한 상태가 되었다. 용융물 내에서의 온도분포는 액체상태일 경우에는 하부가열면과 상변화가 일어나는 경계면부근을 제외하고는 거의 일정한 온도분포를 나타내고 있으며 용융물이 고화된 피막층에서는 급격한 온도변화를 보여주고 있다.

  • PDF

Shape optimal design of a 2-D heat transfer system with the isoparametric finite element (等係數 유한요소를 사용한 2차원 열전달시스템의 형상 최적설계)

  • 유영면;박찬우
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.1
    • /
    • pp.82-87
    • /
    • 1987
  • In this study a method of shape optimization is applied to two dimensional heat transfer system. For this the optimization problem is defined in a functional form including cost, constraints and the system governing equation. Then the material derivative concept in continuum mechanics and the adjoint variable method are employed for the shape design sensitivity analysis. With the sensitivity analysis results, an optimum is sought with the gradient projection optimization algorithm. The two dimensional isoparametric finite elements are used for accurate analysis and sensitivity calculations. The above method is employed to find the boundary shape to achieve a desired temperature distribution along a segment of the boundary subject to the maximum area constraint.

Coupled Thermal/Structural Analysis of Mechanical Ablation by Domain/Boundary Decomposition Method (영역/경계 분할법을 적용한 기계적 삭마 과정의 열구조 연계 해석)

  • Shin, Eui-Sup;Kim, Sung-Jun;Kim, Jong-Il
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.1
    • /
    • pp.1-8
    • /
    • 2011
  • A coupled thermal/structural analysis of mechanical ablation is performed based on domain/boundary decomposition and finite element method. The ablative material non-linearity and boundary non-linearity can be easily localized within a few subdomains and/or on the boundary interfaces. An enthalpy method is applied to simplify the effect of heat of pyrolysis in the ablative subdomains. In addition, maximum in-plane shear stress is considered as a surface recession criterion for the mechanical ablation simulation. The basic characteristics of the proposed method are examined carefully through numerical experiments.

The Throughflow Effects on Natural Convection in Horizontal Porous Layer (수평 다공층에서 수직 관통류가 자연대류 열전달에 미치는 영향에 관한 연구)

  • 서석진
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.209-215
    • /
    • 1998
  • This paper investigated the vertical throughflow effects on natural convection due to heating from below in horizontal porous layer. The motion of the fluid in the porous layer is governed by Brinkman-Darcy equation. And compared Critical Rayleigh number in case of throughflow with no throughflow. Investigated Nusslet number, isothermalline and flow with the variation of the strength of throughflow in a constant Rayleigh number. In the numerical analysis, flow is assumed to be two-dimensional and unsteady. The numerical scheme used is a finite-difference method. In the experimental study, Temperature distribution was measured by use of Liquid Crystal film. As a results, indicated that throughflow influences largely on the temperature field and as the strength of throughflow increased, unstability of natural convection decreased. Also it could predict the strength of natural convection with the measured Nusselt number.

  • PDF

Numerical Simulation of Propylene Vertical Wall Fires (프로필렌 수직벽화재의 수치시뮬레이션)

  • Park, Woe-Chul
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.404-409
    • /
    • 2009
  • 수직벽 화재 예측의 정확성을 확인하기 위하여 화재 시뮬레이션용 전산유체역학 모델인 Fire Dynamics Simulator를 프로필렌 수직벽 화재에 적용하였다. 단위면적당 연소율 $7.0{\sim}29.29g/m^2-s$에 대한 버너 중심에서 측정한 온도분포와 비교한 결과, 최고온도가 낮게 예측되는 것 외에는 실험과 잘 일치하였다. 또 연소율의 증가에 따라 경계측의 두께가 일관되게 증가하였다.

  • PDF

The Design of DID Non-Face-To-Face Education Platform on Blockchain (블록체인 기반 DID 비대면 실습교육 플랫폼 설계)

  • Kong, Young-Jae;Chang, Hang-Bae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2021.11a
    • /
    • pp.352-354
    • /
    • 2021
  • 코로나 19의 확산으로 인해 온·오프라인의 경계가 희미해짐과 동시에 비대면 형태 서비스가 확산되고 있으며, 교육 분야에서도 비대면 화상 강의와 원격수업의 적용이 일상화되고 있다. 기존의 비대면 화상 강의 시스템의 경우, 피교육자 신원확인 미흡에 따른 비인가자 접근 및 교육 방해 행위가 발생하였고, 교육내용 및 보고서 등 교육자와 피교육자 간 송·수신 내용 노출의 위험성이 있으며, 대량의 트래픽 유발에 따른 수업 방해가 가능하여 보안상의 대책이 요구된다. 본 논문에서는 기존의 비대면 형태의 피교육자 신원확인 미흡에 따른 비인가 접근 및 교육 방해 행위와 교육자와 피교육자 사이의 송·수신 내용의 위험성을 해결하고, 대량의 트래픽 유발에 따른 수업 방해에 대한 보안대책으로 블록체인 기반 DID 비대면 실습교육 플랫폼 설계를 제안한다.

Development and Application of Ultra Small Micro-Cone Penetrometer (초소형 마이크로콘 관입시험기의 개발 및 적용)

  • Lee, Jong-Sub;Shin, Dong-Hyun;Yoon, Hyung-Koo;Lee, Woo-Jin
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.2
    • /
    • pp.77-86
    • /
    • 2008
  • The disturbance zone and measured values are affected by the size of the penetrometer. The local value may be measured by the smaller penetrometer. An ultra small Micro-Cone penetrometer (5mm in outer diameter) is designed and manufactured to characterize soil properties with minimum disturbance during penetration tests. The tip resistance is measured by using stain gauges attached near the Micro-Cone. In addition, the friction sleeve is adopted to effectively remove the skin friction from the tip resistance. Design concern includes the installation of stain gauges, circuits, penetration systems, penetration rate, sampling rate, operating temperature, and calibration. Application tests show that the clay interface, and the soil layers consisting of clay and sand are clearly detected by the Micro-Cone. Furthermore, the cone tip resistances measured by the Micro-Cone and the miniature cone (16mm in outer diameter) are similar. Note the resolution is much higher in the Micro-Cone. This study shows that the Micro-Cone may effectively detect the soil interface with high resolution, and with minimum disturbance.

Linear Stability of Variable-Viscosity Fluid Layer under Convection Boundary Condition (대류 조건하의 가변 점성 유체층의 선형 안전성)

  • 송태호
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.132-141
    • /
    • 1992
  • The critical condition for onset of Benard convection with variable viscosity .nu.=.nu.$_{0}$exp(-CT) has been obtained using a linear stability theory. The bottom wall is rigid while the upper surface may be either free or rigid. The two boundaries are subject to convective heat transfer. The critical Rayleigh numbers are presented up to maximum viscosity ratio of 3000. It is greater for smaller upper and/or lower surface Biot numbers. Its dependence on the viscosity ratio is complicated. However, a simple sublayer theory is found to be applicable for extremely large viscosity ratio. In such cases, the critical Rayleigh number and the critical wave number are functions of viscosity ratio and lower surface Biot number.r.