Development of Comparative Calibration System for Helium Leak Standard by Using Mass Spectrometer Type Leak Detector (질량분석기형 누출검출기를 이용한 헬륨투과형 표준 누출 비교 교정 장치 개발)

  • Hong, Seung-Soo;Lim, In-Tae;Kim, Jin-Tae;Shin, Yong-Hyeon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.151-156
    • /
    • 2008
  • Many kinds of mass spectrometer type leak detectors have been widely used for detecting leak of vacuum processes in semiconductor and display industries etc. The leak detectors should be often calibrated by the permeation type standard leak in order to ensure accurate and reproducible leak measurement. We have developed a comparative calibration system for permeation type standard leak by using mass spectrometer type leak detector and specification of the calibration method. Following this technique the reliable calibration for leak standard ran be performed even in fields.

Investigation of Response of Several Neutron Surveymeters by a DT Neutron Generator (DT 중성자 발생기에 의한 중성자 검출기 반응도 조사)

  • Kim, Sang-In;Jang, In-Su;Kim, Jang-Lyul;Lee, Jung-Il;Kim, Bong-Hwan
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • Several neutron measuring devices were tested under the neutron fields characterized with two distinct kinds of thermal and fast neutron spectrum. These neutron fields were constructed by the mixing of both thermal neutron fields and fast neutron fields. The thermal neutron field was constructed using by a graphite pile with eight AmBe neutron sources. The fast neutron field of 14 MeV was made by a DT neutron generator. In order to change the fraction of fast neutron fluence rate in each neutron fields, a neutron generator was placed in the thermal neutron field at 50 cm and 150 cm from the reference position. The polyethylene neutron collimator was used to make moderated 14 MeV neutron field. These neutron spectra were measured by using a Bonner sphere system with an LiI scintillator, and dosimetric quantities delivered to neutron surveymeters were determined from these measurement results.

Chest Wall Thickness Measurement of the LLNL Phantom for Ce Detectors (Ce 검출기를위한 LLNL 팬텀의가슴벽두께측정)

  • Lee, Tae-Young;Lee, Jong-Il;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.1
    • /
    • pp.3-9
    • /
    • 2000
  • The Korea Atomic Energy Research Institute acquired the Lawrence Livermore National Laboratory phantom for calibration of germanium detectors used for in vivo measurement of radionuclides deposited in human lungs. The manufacturer inscribed concentric circles as a phoswich detector positioning guides on the phantom's torso plate and its overlay plates, and provided the effective thickness of the chest wall for each plate measured at locations over the circles. However, since the germanium detectors are of different sizes, the areas considered for phoswich detectors were no. longer applicable for the locations of the germanium detectors on the phantom. Therefore, we re-evaluated the effective thickness of the phantom to determine if the manufacturer' s data are valid for germanium detectors in use for in vivo lung counting or if new values must be implemented. Differences no more than 3% in effective thickness were found between the germanium detector regions to be used at the Korea Atomic Energy Research Institute and the phoswich detector regions prescribed by the manufacturer.

  • PDF

Geometric distortion correction of fluorescein ocular fundus photographs (형광 안저 사진의 기하 왜곡 교정)

  • 권갑현;하영호;김수중
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.183-192
    • /
    • 1991
  • Ophthalmoscopy following the intravenous injection of fluorescein has gained great diagnostic importance in ophthalmology. This technique provides sequential evaluation of the anatomic and physiologic status of the choroidal and retinal vasculature. In order to detect the changes between fluorescein ocular fundus image frames, the direct subtraction of the two frames is inadequate because of geometric distortions and background gray level differences in two images. In this study, a scheme for the correction of the geometric distortions is proposed. Precise control point coordinate values for transformation functions are manually determined after the process including a series of blood vessel detection and thinning, and one frame is mapped to another, and then a geometric distortion corrected image is obtained. When the corrected image is used in interframe change detections, a sucessful result is ensured.

  • PDF

Calibration of CR-39 for Measurement of Radon in Air (공기중의 라돈 농도 측정을 위한 CR-39의 교정)

  • Park, Y.W.;Chang, S.Y.;Ha, C.W.;Ro, S.G.
    • Journal of Radiation Protection and Research
    • /
    • v.14 no.2
    • /
    • pp.18-22
    • /
    • 1989
  • In order to calibrate the CR-39 Solid State Nuclear Track Detector (SSNTD), a closed -circulation type SSNTD-Calibration-System containing a radon-cup with the Millipore filter has been set-up, and the tracks produced on the SSNTD were measured for the known amount of radon concentration. Calibration factor for the time integrated radon concentration as a function of the track density on CR-39 was estimated to be $0.24{\pm}0.09(pCi/l)\;day/(Tr/cm^2)$.

  • PDF

단순 노외계측기 교정법

  • 하창주;정선교;성기봉;우해석;이상희;박현택;조희봉;박재원;윤준구
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.433-439
    • /
    • 1996
  • 노심 외각에 설치되어 노심 외각으로 누설되는 중성자를 검출하여 노심내의 출력 변화를 지시해 주는 노외계측기(Excore Detector)는 운전중 노심의 변화를 정확히 감지하도록 정기적으로 교정되어져야 한다. 노외계측기는 노내계측기(Incore Detector)를 통하여 측정되어진 축방향 출력편차(Axial Offset)를 이용하여 교정하고 있다. 기존의 방법은 노내계측기로 최소한 4회 노심 출력을 측정하여 최소자승법(Least Square Method)으로 상수들을 구한후 노외계측기를 교정한다. 여기서 소개되는 단순 노외계측기 교정법은 노내계측기로 2회 측정되어진 자료들을 이용하는 2점 교정법과 1회 측정되어진 자료들을 이용하는 1점 교정법으로, 계측기 반응상수(Detector Response Factor)를 계산한후 교정되어진 노외계측기의 출력편차를 측정값과 비교하였다. 위의 두가지 방법을 고리 3호기 9주기, 10주기에 적용하여 노심 운전영역(~$\pm$10%)에서 2점 교정법은 최대 1.40 %, 1점 교정법은 최대 0.63 %의 오차를 보여주고 있다. 단순 노외계측기 교정법은 노심출력을 1회 또는 2회 측정하므로 교정시간을 줄이고 제어봉의 사용을 억제하여 방사성 폐기물을 감소시키는 효과와 기존의 교정 방법과 같은 정확성을 기대할수 있다.

  • PDF

Development of Relative Calibration Method for Measurement of Radon and Application (라돈농도 측정을 위한 고체비적검출기의 상대교정법 개발 및 응용)

  • Park, Young-Woong;Yang, Hyun-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.243-250
    • /
    • 1997
  • A relative-calibration-method of solid-state-track-detector for measurement of radon in air has been developed, and the concentration of radon in each room of a 15th-floor-apartment was measured by using the relative calibrated SSTD. There is a tendency to decrease the concentration of radon when the floor is higher, but the main factor to reduce the concentration of radon in room appeared to be ventilation rate. Average concentration of radon of the 15th-floor-apartment was $1.50{\pm}0.51pCi/l$, and the highest and the lowest concentration of radon were $2.68{\pm}0.32pCi/l$, $0.69{\pm}0.16pCi/l$ respectively.

  • PDF

Measurement of Detection Efficiency of Plastic Track Detector to ${\alpha}-particle$ (고체비적검출기의 알파선 검출효율 측정에 관한 연구)

  • Park, Young-Woong;Yang, Hyun-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.3
    • /
    • pp.167-173
    • /
    • 1996
  • The calibration method for the detection efficiency of solid state track detector to alpha is presented, and the detection efficiency of CN-85 and LEXAN to alpha is measured by this method. The results are 97% and 57% in CN-85 and LEXAN, respectively. The reason for a better result in CN-85 in not only the high sensitivity but also the low energy dependency with comparing for LEXAN. The peak detection efficiency is 3MeV and 1.8MeV in CN-85 and LEXAN, respectively.

  • PDF