• Title/Summary/Keyword: 검사장치

Search Result 1,054, Processing Time 0.031 seconds

A Comparison of Lens Centrations on Cornea with RGP Lens Fitting by the Measured Values using Keratometer and Corneal Topography (각막곡률계와 각막 지형도 검사에서의 측정값을 이용한 RGP 렌즈 피팅시 각막에서의 중심안정위치 비교)

  • Kim, So Ra;Park, Sang-Il;Lee, Se Eun;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2011
  • Purpose: The present study was conducted to compare the centration of RGP lens on cornea when lens was fitted based on keratometric astigmatisms measured by keratometer and the lens centration when fitted by corneal topography. Methods: Thirty eight eyes of 19 male and female in their twenties were applied RGP lens with 9.9 mm of diameter by the keratometric astigmatisms classified by the measurement with a keratometer. Then, lens centrations were estimated using high speed camera and compared with the lens centration when fitted by total keratometric astigmatism using corneal topography. The relationship of the steepest location of cornea and lens centration was further compared. Results: With the rule astigmatism, lens centration was not changed even with the difference in central and total keratometric astigmatisms. When the relationship of the steepest part of cornea measured by corneal topography and lens centration was analyzed, the lens centration in vertical direction was exactly correlated with the steepest part of cornea in 52.3% of subjects. In the case of non-correlation, the steepest part of cornea was mostly upper part of cornea, however, lens centration was located on lower part of cornea. The lens centration in horizontal direction was exactly correlated with the steepest region of cornea in 65.6% of subjects. In non-correlated case, the difference in cornea curvatures between the steepest and the flattest parts was smaller than 0.05 mm in 76.9% of subjects. Conclusions: From these results, we conclude that corneal topographic patterns may more contribute the centration of RGP lens on cornea than the difference in central and total keratometric astigmatisms.

The Differences of Anthropometric and Polysomnographic Characteristics Between the Positional and Non-positional Obstructive Sleep Apnea Syndrome (체위 의존성 및 체위 비의존성 폐쇄성 수면 무호흡증후군의 신체계측인자 및 수면구조의 차이)

  • Park, Hye-Jung;Shin, Kyeong-Cheol;Lee, Choong-Kee;Chung, Jin-Hong;Lee, Kwan-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.956-963
    • /
    • 2000
  • Backgrounds : Obstructive sleep apnea syndrome(OSA) can divided into two groups, positional(PP) and non-positional(NPP) obstructive sleep apnea syndrome, according to the body position while sleeping. In this study, we evaluated the differences of anthropometric data and polysomnographic recordings between the two types of sleep apnea syndrome. Materials : Fifty patients with OSA were divided two groups by Cartwright's criteria. The supine respiratory disturbance index (RDI) was at least two times higher than the lateral RDI in the PP group, and the supine RDI was less than twice the lateral RDI in the NPP group. This patients underwent standardized polysomnographic recordings. The anthropometric data and polysomnographic data were analyzed, statistically. Results : Of all 50 patients, 30% were found to be positional OSA. BMI was significantly higher in the PP group(p<0.05). Total sleep time was significantly longer in the PP group (350.6$\pm$28.2min, 333.3$\pm$46.0min, (p<0.05). Sleep efficiency was high in the PP group(89.6$\pm$6.4%, 85.6$\pm$9.9%, p<0.05). Deep sleep was significantly higher and light sleep was lower in the PP group than in the NPP group but no difference was observed in REM sleep between the two groups. Apnea index(AI) and RDI were significantly lower( 17.0$\pm$10.6, 28.5$\pm$13.3, p<0.05) and mean arterial oxygen saturation was higher in the PP group(92.7$\pm$1.8%. p<0.05) than in the NPP group. Conclusion : Body position during sleep has a profound effect on the frequency and severity of breathing abnormalities in OSA patients. A polysomnographic evaluation for suspected OSA patients must include monitoring of the body position. Breathing function in OSA patients can be improved by controlling their obesity and through postural therapy.

  • PDF

Invivo Dosimetry for Mammography with and without Lead Apron Using the Glass Dosimeters (유방촬영술에서 유리선량계를 이용한 납치마의 선량차폐 효과 측정)

  • Yu, Su-Jeong;Lim, Sangwook;Ma, Sun Young;Seo, Sun-Youl;Kim, Young-Jae;Kang, Young-Nam;Keum, Ki Chang;Cho, Samju
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.93-98
    • /
    • 2015
  • The purpose of this study is to see the usefulness of lead apron for critical organs near the breast under examining. For clinical experiment, 30 female volunteers who agreed to their participation in the experiments, were chosen and divided into two groups, 15 in group A and 15 in group B respectively. group A is to see whether each side of breast under mammography affects to other side glandular on the critical organs is same, because it is not allowed to scan the both breast for same person or to scan repeatedly. Group B is to see the effectiveness of lead apron during the mammography of right breast. Glass dosimeters were placed on the thyroid, the contralateral breast, and lower abdomen where near the breast during examining. The average glandular doses on the surface in mammography of the thyroid gland, the contralateral breast, the lower abdomen were 0.0692 mGy, 0.6790 mGy, and 0.0122 mGy, respectively, which was an extremely low level of glandular dose. In group B, as to the thyroid gland, average dose was decreased from 0.0922 mGy to 0.0158 mGy. The average dose of contralateral breast was decreased from 0.8575 mGy to 0.0286 mGy. The average doses of lower abdomen was decrease 0.0150 mGy to 0.0173 mGy. As to the lower abdomen, dose decreased from 0.0150 mGy before the use of an apron down to 0.0173 mGy after the use. As p-value was under 0.05, statistically significant difference was observed between the two groups. Wearing an apron can have the protective effects on the thyroid gland up to 20 times lower than not wearing one. Besides, it is also necessary to protect the other breast during the examination by wearing one.

The Study On Quality Control of Magnetic Resonance Imaging System (자기공명영상장치의 정도관리에 관한 연구)

  • Jeong, Cheon-Soo;Lim, Cheong-Hwan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.178-186
    • /
    • 2009
  • The quality control is needed to ensure the accuracy of medical information and achieved by evaluating the performance of and maintaining the system and practicing various measurements and evaluations. The Korean Institute for Accreditation of Medical Image, therefore, have held educational program for quality control of special medical equipments. The major of programs participants, however, are radiology specialists with only small number of radiological technologists from some hospitals, furthermore, the follow-up education and the share of information between participants and non-participants are insufficient in general, thus, the knowledge level of radiological technologists, regardless of their participation, is relatively low. This study carried out the questionnaire research for the 500 radiological technologists registered in Korean Society of MRI Technology, on the basis of 2008, and performed analysis for five months from May to Oct., 2008. The questionnaires were delivered by post to each radiological technologists and the response rate was 36%(n=180). The results of this revealed that the 86.7% of respondents felt the necessity of inspection on quality management, while only the 27.8% completed the educational program for manager of special medical equipment. and only the half(53.9%) had the knowledge about inspection on quality management. The completion of educational program had no correlations with sex, age, size of occupying hospital, the number of radiological technologists in occupying site and MRI laboratory, career year of general radiologist and in MRI laboratory, and the presence of biomedical engineering department in occupying hospital. The 78.0% of participants at the educational program for quality management held by the Korean Institute for Accreditation of Medical Image had the knowledge about inspection on quality management(p<.05) whereas the 43.9% of the hospitals held such program and the 54.4% of radiological technologists from those hospitals had related knowledge, which indicated that such programs held by hospitals had not effects on the knowledge level of radiological technologists. This indicates also that the contents, methods, and other conditional factors of educational programs are important for the outcome of them.

Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control (자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향)

  • Kang-Min Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.3
    • /
    • pp.257-265
    • /
    • 2024
  • In this study, we applied AEC(Auto Exposure Control), which is used in many chest examinations, to evaluate whether medical devices inserted into the body affect the dose and image quality of chest images. After attaching three HIMD(Human implantable medical devices) to the ion chamber, the Monte Carlo methodology-based program PCXMC(PC Program for X-ray Monte Carlo) 2.0 was applied to measure the effective dose by inputting the DAP(Dose Ares Product) value derived from the Pacemaker and CRT and Chemoport Additionally, to evaluate image quality, we set three regions of interest and one noise region on the chest and measured SNR and CNR. The final study results showed significant differences in DAP and Effective dose. There was a significant difference between Pacemaker and CRT when AEC was applied and not applied. (p<0.05) When applied, the dose increased by 37% for Pacemaekr and 52% for CRT. Chemoport showed a 10% increase in effective dose depending on whether AEC was applied, but there was no significant difference. (p>0.05) In the image quality evaluation, there was no significant difference in image quality between all HIMD insertions and AEC applied or not. (p>0.05) Therefore, when the HIMD was inserted into the chest during a chest x ray and overlapped with the ion chamber sensor, the effective dose increased, and there was no difference in image quality even at a low dose without AEC. Therefore, when performing a chest X-ray examination of a patient with a HIMD inserted, it is considered that performing the examination without applying AEC is a method that can be considered to reduce the patient's radiation exposure.

Two Dimensional Size Effect on the Compressive Strength of Composite Plates Considering Influence of an Anti-buckling Device (좌굴방지장치 영향을 고려한 복합재 적층판의 압축강도에 대한 이차원 크기 효과)

  • ;;C. Soutis
    • Composites Research
    • /
    • v.15 no.4
    • /
    • pp.23-31
    • /
    • 2002
  • The two dimensional size effect of specimen gauge section ($length{\;}{\times}{\;}width$) was investigated on the compressive behavior of a T300/924 $\textrm{[}45/-45/0/90\textrm{]}_{3s}$, carbon fiber-epoxy laminate. A modified ICSTM compression test fixture was used together with an anti-buckling device to test 3mm thick specimens with a $30mm{\;}{\times}{\;}30mm,{\;}50mm{\;}{\times}{\;}50mm,{\;}70mm{\;}{\times}{\;}70mm{\;}and{\;}90mm{\;}{\times}{\;}90mm$ gauge length by width section. In all cases failure was sudden and occurred mainly within the gauge length. Post failure examination suggests that $0^{\circ}$ fiber microbuckling is the critical damage mechanism that causes final failure. This is the matrix dominated failure mode and its triggering depends very much on initial fiber waviness. It is suggested that manufacturing process and quality may play a significant role in determining the compressive strength. When the anti-buckling device was used on specimens, it was showed that the compressive strength with the device was slightly greater than that without the device due to surface friction between the specimen and the device by pretoque in bolts of the device. In the analysis result on influence of the anti-buckling device using the finite element method, it was found that the compressive strength with the anti-buckling device by loaded bolts was about 7% higher than actual compressive strength. Additionally, compressive tests on specimen with an open hole were performed. The local stress concentration arising from the hole dominates the strength of the laminate rather than the stresses in the bulk of the material. It is observed that the remote failure stress decreases with increasing hole size and specimen width but is generally well above the value one might predict from the elastic stress concentration factor. This suggests that the material is not ideally brittle and some stress relief occurs around the hole. X-ray radiography reveals that damage in the form of fiber microbuckling and delamination initiates at the edge of the hole at approximately 80% of the failure load and extends stably under increasing load before becoming unstable at a critical length of 2-3mm (depends on specimen geometry). This damage growth and failure are analysed by a linear cohesive zone model. Using the independently measured laminate parameters of unnotched compressive strength and in-plane fracture toughness the model predicts successfully the notched strength as a function of hole size and width.

Construction and Tests of the Vacuum Pumping System for KSTAR Current Feeder System (KSTAR 전류전송계통 진공배기계 구축 및 시운전)

  • Woo, I.S.;Song, N.H.;Lee, Y.J.;Kwag, S.W.;Bang, E.N.;Lee, K.S.;Kim, J.S.;Jang, Y.B.;Park, H.T.;Hong, Jae-Sik;Park, Y.M.;Kim, Y.S.;Choi, C.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.6
    • /
    • pp.483-488
    • /
    • 2007
  • Current feeder system (CFS) for Korea superconducting tokamak advanced research(KSTAR) project plays a role to interconnect magnet power supply (MPS) and superconducting (SC) magnets through the normal bus-bar at the room temperature(300 K) environment and the SC bus-line at the low temperature (4.5 K) environment. It is divided by two systems, i.e., toroidal field system which operates at 35 kA DC currents and poloidal field system wherein 20$\sim$26 kA pulsed currents are applied during 350 s transient time. Aside from the vacuum system of main cryostat, an independent vacuum system was constructed for the CFS in which a roughing system is consisted by a rotary and a mechanical booster pump and a high vacuum system is developed by four cryo-pumps with one dry pump as a backing pump. A self interlock and its control system, and a supervisory interlock and its control system are also established for the operational reliability as well. The entire CFS was completely tested including the reliability of local/supervisory control/interlock, helium gas leakage, vacuum pressure, and so on.

Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment (자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정)

  • Jang, Hong-Seok;Suh, Tae-Suk;Yoon, Sei-Chul;Ryu, Mi-Ryeong;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.1
    • /
    • pp.45-52
    • /
    • 1995
  • This study is to compare A point doses in human pelvic phantom by film dosimetry, computer planning and manual calculation by using of along-away table. We developed tissue equivalent human pelvic phantom composed of four pieces of cylindrical acryl tubes with water, to simulate intracavitary radiation (ICR) in patients with cervix cancer. When the phantom assembled from 4 pieces, it has a small space for inserting Fletcher-Suit-Delclos applicator like a human vagina. Fletcher-Suit-Delclos applicator inserted into the space was packed tightly with furacin gauzes, and three $^{137}Cs$ sources with radioactivity of $15.7mg\;Ra-eq$ were inserted into the tandem. For the film dosimetry, two pieces of X-OMAT V film (Kodak Co.) of which planes include point A, were arranged orthogonally in the slits between phantoms. A point dose and iso-dose curves were measured by means of optical densitometer. A point doses by film dosimetry, RTP system and manual calculation by using of along-away table were compared, and iso-dose curves by film dosimetry and computer planning were also compared. The dose of A point was 51.2cGy/hr by film dosimetry, 46.7cGy/hr by RTP system and 47.9 cGy/hr by along-away table. A point dose by computer planning was similar to the dose by calculation using of along-away table with acceptable accuracy $({\pm}3%)$, however, the dose by film dosimetry was different from two others with about 10% error. Since most clinical beams contains a scatter component of low energy photons, the correlation between optical density and dose becomes tenuous. In addition, film suffers from several potential errors such as changes in processing conditions, interfilm emulsion differences, and artifacts caused by air pockets adjacent to the film. For these reasons, absolute dosimetry with film is impractical, however, it is very useful for checking qualitative patterns of a radiation distribution. In future, solid state dosimeter such as TLD must be used for the dosimetry of ionizing radiation. When considerable care is used, precision of approximately 3% may be obtained using TLD.

  • PDF

LONG-TERM EVALUATION OF A $SnF_2$ GEL FOR CONTROL OF GINGIVITIS AND DECALCIFICATION IN ADOLESCENT ORTHODONTIC PATIENTS (청소년 교정환자들의 치은염 및 치아탈회 조절을 위해 사용한 겔형 불화주석($SnF_2$ gel)의 장기간 평가)

  • Boyd, Robert L.;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.25 no.3 s.50
    • /
    • pp.235-245
    • /
    • 1995
  • The purpose of this paper is to review two recently reported, long-term studies of several chemical methods to control gingivitis and decalcification in adolescent orthodontic patients. The first study(gingivitis study) was designed to determine whether conventional toothbrushing and twice daily use of a brush-on 0.4 per cent $SnF_2$ gel containing more than 90 per cent available $Sn^{2+}$ would be more effective for controlling plaque accumulation and gingivitis in the presence of orthodontic appliances than conventional toothbrushing alone. The second study(decalcification study) was designed to compare the effectiveness of controlling decalcification in orthodontic patients with either a II00 ppm F tooth paste used alone, this same toothpaste and a 0.05 percent NaF rinse or this toothpaste and a 0.4 percent $SnF_2$ gel. In the gingivitis study, sixty-five consecutively treated adolescents who were to receive full-mouth fixed orthodontic appliances were assigned to two groups according to age and sex criteria. In the decalcification study an additional 30 subjects(95 total) were similarly assigned to a third group. The first group(control, n=35) used only toothbrushing with a standard fluoride(1100 ppm F) toothpaste. The second group used toothbrushing with a similar dentifrice supplemented with a 0.4 percent $SnF_2$ gel($SnF_2$ gel group, n=30) used twice daily for the entire 18-month study period. The third group(in the decalcification study only) used a similar toothpaste and 0.05 percent NaF rinse(NgF rinse group, n=30). Clinical assessments of plaque accumulation using the Plaque Index, gingival inflammation using the Gingival Index, and coronal staining were completed single-blinded before appliances were placed and 1, 3, 6, 9, 12 and 18 months after appliances were placed. Decalcification was assessed single blind on all labial surfaces of all erupted teeth before appliances were placed and 3 months after appliances were removed. The results of the gingivitis study indicated that the $SnF_2$ gel gorup had significantly lower scores for the Plaque Index(p<0.01) and Gingival Index(p<0.001) at all examinations during orthodontic treatment than did the control group. In the $SnF_2$ gel group, one subject developed mild coronal staining and two subjects developed moderate staining. In the decalcification study, when pre-treatment levels of decalcification were subtracted from post-treatment values, significantly lower decalcification scores(p<0.05) were found for both whole mouth and first molars in the NaF rinse and gel groups as compared with the control gorup(toothpaste alone). Although the gel group consistently had less decalcification than the rinse group, this difference only approached statistical significance.

  • PDF

Performance Test of Portable Hand-Held HPGe Detector Prototype for Safeguard Inspection (안전조치 사찰을 위한 휴대형 HPGe 검출기 시제품 성능평가 실험)

  • Kwak, Sung-Woo;Ahn, Gil Hoon;Park, Iljin;Ham, Young Soo;Dreyer, Jonathan
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.54-60
    • /
    • 2014
  • IAEA has employed various types of radiation detectors - HPGe, NaI, CZT - for accountancy of nuclear material. Among them, HPGe has been mainly used in verification activities required for high accuracy. Due to its essential cooling component(a liquid-nitrogen cooling or a mechanical cooling system), it is large and heavy and needs long cooling time before use. New hand-held portable HPGe has been developed to address such problems. This paper deals with results of performance evaluation test of the new hand-held portable HPGe prototype which was used during IAEA's inspection activities. Radioactive spectra obtained with the new portable HPGe showed different characteristics depending on types and enrichments of nuclear materials inspected. Also, Gamma-rays from daughter radioisotopes in the decay series of $^{235}U$ and $^{238}U$ and characteristic x-rays from uranium were able to be remarkably separated from other peaks in the spectra. A relative error of enrichment measured by the new portable HPGe was in the range of 9 to 27%. The enrichment measurement results didn't meet partially requirement of IAEA because of a small size of a radiation sensing material. This problem might be solved through a further study. This paper discusses how to determine enrichment of nuclear material as well as how to apply the new hand-held portable HPGe to safeguard inspection. There have been few papers to deal with IAEA inspection activity in Korea to verify accountancy of nuclear material in national nuclear facilities. This paper would contribute to analyzing results of safeguards inspection. Also, it is expected that things discussed about further improvement of a radiation detector would make contribution to development of a radiation detector in the related field.