• Title/Summary/Keyword: 검사장치

Search Result 1,047, Processing Time 0.028 seconds

MTF Evaluation according to change in posture and channel during CT examination for wrist Joint : X-axis and Z-axis changes around Isocenter (손목관절 CT 검사 시 자세 변화와 채널 변경에 따른 MTF 평가 : Isocenter를 중심으로 X-축, Z-축 변화)

  • Seo, Min Jae;Lim, Jong Chon;Jung, Dabin;Han, Dong Kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.811-817
    • /
    • 2020
  • This study aims to evaluate the Modulation Transfer Function (MTF) according to the change in the number of channels of the CT examination device by changing the posture of the patient to the X-axis and Y-axis in the wrist joint CT examination. Using a CT device and a wrist phantom, the test was performed by moving 0 (matched), 5, 10, and 15 cm in the X-axis around the isocenter, and the Z-axis was rotated by -20° and -40°. For the test, 16, -40 and 64 channels were used to check whether there was a difference for each number of channels. The examined images were compared by measuring the MTF values of the ulna and left and right sides of the radius. In the experiment where the isocenter was moved along the X-axis, the MTF value decreased with an increase in the moving distance, and the MTF value was found to be unaffected by the number of channels. In the experiment in which the wrist joint was rotated by -20° and -40° on the Z-axis, the degree of deviation and MTF were found to be irrelevant. It was not related to the number of channels either. In conclusion, the movement of the wrist along the X-axis should be restrained as much as possible for a wrist joint CT scan, whereas deviation around the Z-axis depending on the environment for the patient would not affect the MTF of the image.

A Multistriped Checkpointing Scheme for the Fault-tolerant Cluster Computers (다중 분할된 구조를 가지는 클러스터 검사점 저장 기법)

  • Chang, Yun-Seok
    • The KIPS Transactions:PartA
    • /
    • v.13A no.7 s.104
    • /
    • pp.607-614
    • /
    • 2006
  • The checkpointing schemes should reduce the process delay through managing the checkpoints of each node to fit the network load to enhance the performance of the process running on the cluster system that write the checkpoints into its global stable storage. For this reason, a cluster system with single IO space on a distributed RAID chooses a suitable checkpointng scheme to get the maximum IO performance and the best rollback recovery efficiency. In this paper, we improved the striped checkpointing scheme with dynamic stripe group size by adapting to the network bandwidth variation at the point of checkpointing. To analyze the performance of the multi striped checkpointing scheme, we applied Linpack HPC benchmark with MPI on our own cluster system with maximum 512 virtual nodes. The benchmark results showed that the multistriped checkpointing scheme has better performance than the striped checkpointing scheme on the checkpoint writing efficiency and rollback recovery at heavy system load.

Identifying Key Factors to Affect Vehicle Inspection and Maintenance(I/M) Test Results Using a Binary Logit Model (California Case Study) (이항로짓모형을 이용한 자동차 배출가스 검사결과에 미치는 요인분석(미국 캘리포니아 사례를 중심으로))

  • Chu, Sang-Ho
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.3 s.89
    • /
    • pp.189-195
    • /
    • 2006
  • For the past decades, vehicle emissions has been a major source of air pollution in urban areas Vehicle inspection and maintenance (I/M) test programs were developed for major metropolitan areas to reduce urban air pollution. However. there are a few studies of exploring major factors to influence I/M test failure. This study develops a logit model to identify key factors affecting overall test failure, using the vehicle I/M test data from California in October 2002. The model results indicate that vehicle age, odometer reading, engine size, vehicle make, presences of emissions control equipment, and test types have significant effects on the probability of I/M test failure.

Development of automatic inspection system of defects on inner surface of pneumatic cylinder-tubes by electronic endoscope (전자내시경을 활용한 공압실린더 튜브 내면의 결함 자동검사시스템 개발)

  • Lho, Tae-Jung;Koo, Bon-Joo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3376-3382
    • /
    • 2014
  • The system developed inspects automatically defects existing on an inner surface of anodically treated aluminum cylinder-tubes. This system consists of automatic inspection software, and electronic endoscope and a conveyor moving device. By applying the optimal brightness conditions to searching for various defects on the inner surface of cylinder tube, the recognition rate of major defects, such as scratch, oxide and weld line reached 99%. If the present visual inspection process is replaced with the automatic defects inspection system, the physical fatigue of the operator could be reduced and the productivity could be increased. The automatic inspection system developed could also improve the quality of the products.

Development of 3D Inspection Equipment using White Light Interferometer with Large F.O.V. (대시야 백색광 간섭계를 이용한 3차원 검사 장치 개발)

  • Koo, Young Mo;Lee, Kyu Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.6
    • /
    • pp.694-699
    • /
    • 2012
  • In this paper, semiconductor package inspection results using white light interferometer with large F.O.V., in order to apply semiconductor product inspection process, are shown. Experimental 3D data repeatability test results for the same special bumps of each substrate are shown. Experimental 3D data repeatability test results for all the bumps in each substrate are also shown. Semiconductor package inspection using white light interferometer with large F.O.V. is very important for the fast 3D data inspection in semiconductor product inspection process. This paper is surely helpful for the development of in-line type fast 3D data inspection machine.

Study on the Exposure Field of Head and Neck with Measurement of X-ray dose Distribution for Dental Panoramic X-ray System (치과 파노라마 장치의 X선 공간선량분포 측정을 통한 두경부 피폭영역 조사에 대한 연구)

  • Oh, Yoonjin;Hong, Girang;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Recently, As people's interest in the health of teeth is increased in the medical field changed into aging society, the number of times for the radiological diagnosis is increased. It can be said that the radiation exposure dose of Korean population is increased. It is also growing concern about radiation exposure. Therefore, the basic data for the dental panoramic X-ray system, its investigation and measuring the radiation dose is needed. In this study, we used ALOKA PDM-117 dosimeter and estimated a two-dimensional dose distribution of the dental panoramic X-ray system (VATEC Pax-400). Dose evaluation about the distribution is confirmed from the point of radiation exposure of a patient. Dose distribution of the dental panoramic X-ray system irradiated chin and the facial region to high dose as well as the parts of teeth. It was founded that the eye lens which are sensitive to radiation are exposed to unnecessary radiation, considering the effect of scattered radiation. The results of this study will be used more accurate dose assessment in a variety of object size and location of measuring dose.

Design for Adhesive Carbon Heating Element X-ray Table with an Attached Heating Device (가열장치를 구비한 부착형 탄소발열체 X선 촬영대 고안)

  • Song, Jongnam;Kim, Eungkon
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.3
    • /
    • pp.131-137
    • /
    • 2015
  • The purpose of this study is to warm up the conventional X-ray table by inventing and design for X-ray table with an attached heating device using less unloaded X-ray, CNT (carbon nano tube) heating element. Configuration of the product design for adhesive carbon heating element X-ray is composed of a conventional X-ray table, carbon nano tube planar heating element, an electrode line, flame resisting protective film, and the bottom film. Characteristics and advantages of this invented product is to provide gentle feeling, the sense of security, and eliminating anxiety to the patient wearing a patient gown and feel the cool air while receiving the test. Thus we are strongly recommend to use this device in the clinical situation.

Identification of Structural Defects in Rail Fastening Systems Using Flexural Wave Propagation (굽힘파 전파 특성을 이용한 레일체결장치의 구조 결함 진단)

  • Park, Jeongwon;Park, Junhong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.1
    • /
    • pp.38-43
    • /
    • 2014
  • An experimental method based on flexural wave propagation is proposed for identification of structural damage in rail fastening systems. The vibration of a rail clamped and supported by viscoelastic pads is significantly influenced by dynamic support properties. Formation of a defect in the rail fastening system induces changes in the flexural wave propagation characteristics owning to the discontinuity in the structural properties. In this study, frequency-dependent support stiffness was measured to monitor this change by a transfer function method. The sensitivity of wave propagation on the defect was measured from the potential energy stored in a continuously supported rail. Further, the damage index was defined as a correlation coefficient between the change in the support stiffness and the sensitivity. The defect location was identified from the calculated damage index.