• Title/Summary/Keyword: 건축주

Search Result 2,904, Processing Time 0.046 seconds

Problems and Improvement Directions of Fire Protection Designing and Supervising Jobs (소방 설계·감리업의 문제점 및 개선방향에 관한 연구)

  • Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8745-8752
    • /
    • 2015
  • Since many accidents have occurred in Korea in these days, many people have lost their health and have been damaged. The damages caused by fires which occur to many buildings where many people always reside takes a substantial share of the total damages. And since the proportions of the domestic fire protection designing/supervising industries are relatively much disregarded compared to other kinds of work, it is in the situation that there are many cases of serious damages because the fire protection equipment didn't exert the proper functions on fire after a building is constructed since the supervision against the poor construction along with the inadequate design. In order to improve such situations, in case of the design industry, the criteria on registration and workforce placement, the scope of operation, the design documents required when requesting the agreement to the construction permits, the responsibilities and authorities about the jobs of the fire protection facility designers must be improved and, in case of supervising industry, the registration criteria, the operation scope and the kinds, methods, targets and criteria of supervision, the criteria on the additional placement of assistant supervisors, the contents and scope of work must be improved, the PQ system and Public Supervision System must be reviewed and the systems for preventing any poor supervision must be improved in order to pursue the security of the people and their properties at the same level as the other kinds of work by preparing for the firm position and foundation of the fire protection design and supervision.

Augmented Reality Based Tangible Interface For Digital Lighting of CAID System (CAID 시스템의 디지털 라이팅을 위한 증강 현실 기반의 실체적 인터페이스에 관한 연구)

  • Hwang, Jung-Ah;Nam, Tek-Jin
    • Archives of design research
    • /
    • v.20 no.3 s.71
    • /
    • pp.119-128
    • /
    • 2007
  • With the development of digital technologies, CAID became an essential part in the industrial design process. Creating photo-realistic images from a virtual scene with 3D models is one of the specialized task for CAID users. This task requires a complex interface of setting the positions and the parameters of camera and lights for optimal rendering results. However, the user interface of existing CAID tools are not simple for designers because the task is mostly accomplished in a parameter setting dialogue window. This research address this interface issues, in particular the issues related to lighting, by developing and evaluating TLS(Tangible Lighting Studio) that uses Augmented Reality and Tangible User Interface. The interface of positioning objects and setting parameters become tangible and distributed in the workspace to support more intuitive rendering task. TLS consists of markers, and physical controller, and a see-through HMD(Head Mounted Display). The user can directly control the lighting parameters in the AR workspace. In the evaluation experiment, TLS provide higher effectiveness, efficiency and user satisfaction compared to existing GUI(Graphic User Interface) method. It is expected that the application of TLS can be expanded to photography education and architecture simulation.

  • PDF

Shear Behavior of Reinforced Concrete Deep Beams with Web Openings (개구부를 갖는 철근콘크리트 깊은 보의 전단거동)

  • 이진섭;김상식
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.6
    • /
    • pp.619-628
    • /
    • 2001
  • In building construction, openings of the story-height deep beams are usually required for accessibility and service lines such as air conditioning ducts, drain pipes and electric units. It is known that the main parameters affecting the load bearing capacity of deep beams with web openings are size, shape, location and reinforcements of openings. However, there have been no pertinent theories and national design codes for predicting ultimate shear strength of reinforced concrete deep beams with web openings. In this study, the shear behavior of simply supported reinforced concrete deep beams with web openings subject to concentrated loads has been scrutinized experimentally. A total of 34 specimens, the geometry of openings, its reinforcements and shear span to depth ratio, being taken as the experimental variables, has been cast and tested in the laboratory. The effects of these structural parameters on the shear strength and crack initiation and propagation have been carefully checked and analyzed. From the tests, it has been observed that the failures of all specimens were due to shear mechanism and the ultimate strength of specimens varies according to the location of openings, by which the formation of compression struts between the loading points and supports are deterred. All of the test results of specimens have been compared with the formulas proposed by previous researchers. The results were closely coincident with the formulas given by Ray and Kong's equation except for some X series specimens having a larger dimension of openings beyond the geometric limits of proposed equations.

A Study on 3D Indoor mapping for as-built BIM creation by using Graph-based SLAM (준공 BIM 구축을 위한 Graph-based SLAM 기반의 실내공간 3차원 지도화 연구)

  • Jung, Jaehoon;Yoon, Sanghyun;Cyrill, Stachniss;Heo, Joon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.17 no.3
    • /
    • pp.32-42
    • /
    • 2016
  • In Korea, the absence of BIM use in existing civil structures and buildings is driving a demand for as-built BIM. As-built BIMs are often created using laser scanners that provide dense 3D point cloud data. Conventional static laser scanning approaches often suffer from limitations in their operability due to the difficulties in moving the equipment, the selection of scanning location, and the requirement of placing targets or extracting tie points for registration of each scanned point cloud. This paper aims at reducing the manual effort using a kinematic 3D laser scanning system based on graph-based simultaneous localization and mapping (SLAM) for continuous indoor mapping. The robotic platform carries three 2D laser scanners: the front scanner is mounted horizontally to compute the robot's trajectory and to build the SLAM graph; the other two scanners are mounted vertically to scan the profiles of surrounding environments. To reduce the accumulated error in the trajectory of the platform through loop closures, the graph-based SLAM system incorporates AdaBoost loop closure approach, which is particularly suitable for the developed multi-scanner system providing more features than the single-scanner system for training. We implemented the proposed method and evaluated it in two indoor test sites. Our experimental results show that the false positive rate was reduced by 13.6% and 7.9% for the two dataset. Finally, the 2D and 3D mapping results of the two test sites confirmed the effectiveness of the proposed graph-based SLAM.

Behavior of Reinforced Concrete Slabs Connected with Hinge Joints of Remodelling Buildings (리모델링 건물의 활절점에 의하여 연결된 철근콘크리트 바닥판의 거동 평가)

  • Sim Kyu-Kwan;Kim Sang-Sik;Lee Jung-Yoon;Choi kwang-Ho;Im Juhyeuk
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.5 s.89
    • /
    • pp.761-768
    • /
    • 2005
  • Lately outmoded and functionally obsolete buildings constructed in 1960s and 1970s are often remodelled and restored. Even though there are not serious structural defects in the existing buildings, many old buildings have been reconstructed to improve residence quality or to extend residence area of the buildings. The experimental or theoretical research on plane expansion of RC apartments is quite scare. In this research, 12 specimens and 19 RC slabs connected by hinged joints were tested. The new slab was connected to the existing slab by hinge joints injecting dowel bars between two slabs. Main parameters of the slabs are types of the dowel bars (D13 and D19), spacing of the dowel bars (150mm, 300mm, and 450mm), and the locations of the steel bars in the existing slabs. The test results indicated that the shear strength of the RC test slabs having various types of dowel bars was about twice that calculated by the ACI 318-02 code. All slabs failed in concrete spatting and the dowel steel bars did not reach their yield strengths.

Light Pollution Survey of Outdoor Lighting in Shopping Complex (쇼핑용 복합빌딩의 옥외조명으로 인한 광공해발생 실태조사)

  • Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.16-26
    • /
    • 2004
  • As the importance of outdoor lighting become more widely recognized, outdoor lighting has been installed in many buildings, plazas, landscape, and historical monuments in Korea, Outdoor lighting on showing complex, in particular, express its values as local landmarks. However, the excessive outdoor lighting in the large-scale shopping complex tends to cause light pollution. Many advanced countries are trying to create a comfortable lighting environment by the guidlines and regulations on outdoor lighting to prevent light pollution. For this research backgrounds, the light pollution of three showing complexes in Seoul have been investigated. For the purpose, luminance of building facade, horizontal illuminance, and vertical illuminance were measured with proper measurement instruments and compared the results with the CIE recommendations. The results of the study are as follows. As no cut-off luminaries are currently installed on pedestrian walks, some glare were occured partially. It also shows that the luminance of building facades are high to improve the degree of public awareness of buildings and advertisements. In other words, the luminance of the building facade, when compared with that of the CIE recommendations, is twice as high and the vatical illuminance of pedestrian walks is far higher than that of the CIE recommendations, which proves the existence of light pollution. As Korea has not yet provided proper regulations or guidelines for the control of light pollution, it is necessary to make appropriate codes for it.

Up-cycling of Air-cooled Ladle Furnace Slag : Environmental Risk Assessment and Mortar Compressive Strength Assesment of Binary and Ternary Blended Cement Using Air-cooled Ladle Furnace Slag (전기로 환원슬래그 Up-cycling : 환경위해성 평가 및 환원슬래그를 혼합하여 제조한 2성분계 및 3성분계 혼합시멘트 모르타르 압축강도 평가)

  • Cho, Han Sang;Mun, Young Bum;Moon, Won Sik;Park, Dae Cheol;Kim, Hyeong Cheol;Choi, Hyun Kook
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.3
    • /
    • pp.159-164
    • /
    • 2015
  • This study investigated the environmental risk for up-cycling of air-cooled ladle furnace slag (LFS) and evaluated the mortar compressive strength of binary and ternary blended cements using LFS of 3, 5, 10 wt%. Based on the Soil Environment Conservation Act standard, there was no environmental risk of the up-cycling of LFS. Results of mortar compressive strength assesment showed that the compressive strength of two blended cements using LFS of lower than 5 wt% was about 1.1 times superior to that of un-substituted cement (ordinary portland cement, OPC); however the compressive strength of those with LFS of 10 wt% decreased with 10% compared with that of OPC.

Research on the Interior Environment Planning of a Postpartum Care Center. (산후 조리원 실내 환경 계획에 관한 연구)

  • Lee, Jong-Hee
    • Archives of design research
    • /
    • v.20 no.1 s.69
    • /
    • pp.253-262
    • /
    • 2007
  • The postpartum care center is a facility which made its debut only about 10 years ago but has now changed the nation's postpartum care culture. Women delivered of a child use the postpartum care center at this time since the low rate of childbirth has become a social phenomenon. However, while the postpartum care center is not supported legally and systematically, anybody can run it after they only file a report on businessman status with the tax office. So there are disordered wave of postpartum care startups which do not have basic facilities. Thus, this study is intended to suggest an interior environment plan considering an efficient space and users' benefits of a postpartum care center which has a characteristic difference from that of ordinary facilities in terms of targeted persons or operations but for which standards are not clear in terms of the Health and Welfare Law and the Medical Service Law. This study was conducted by investigating the actual condition of the entrance space, living space, common-use space, nursing space, administration and attached space in the six postpartum care centers selected from Seoul and Kyeonggi-do region and suggesting the direction of improvements, thus establishing the direction of interior designs and an interior environment plan. Hopefully, this study would be used as basic data on interior building plans, thus being helpful in enhancing the satisfaction of the postpartum care center user and operating the facility.

  • PDF

A Study on Reducing Method for Stack Effect in High-rise Building (고층 건축물 연돌효과 저감 방법에 대한 연구)

  • Kim, Jin Soo
    • 한국방재학회:학술대회논문집
    • /
    • 2011.02a
    • /
    • pp.66-66
    • /
    • 2011
  • 중위도 이북의 건물에서 고층건물의 혹한기 연돌효과는 건물의 여러 가지 기능에 큰 영향을 미치며, 승강기 승강로는 화재시 차압 때문에 연기의 주된 전파통로가 된다. 외피의 밀폐성능을 높여 건물 내부의 연도효과를 줄일 수 있으나, 외피의 밀폐기능은 비상시 피난을 위해 피난경로를 개방하는 순간 일시에 무력화된다. 또한 건물 외피의 밀폐성능이 우수할수록 연돌효과 그 자체로써 건물외피에 미치는 구조적 영향이 커진다. 고층부의 연돌효과는 외피를 밖으로 밀어내는 작용이므로 풍하측에서는 마이너스 풍압에 더하여 건물 외피에 부담을 증가시킨다. 그러므로 고층건물에 발생하는 혹한기 연돌효과의 영향을 정리하자면 다음과 같다. ${\bullet}$ 건물 외벽 및 창문에 미치는 구조적 영향 ${\bullet}$ 제연 시스템의 기능 저해 ${\bullet}$ 승강기 문 개폐 장애와 소음 등 설비 기능의 부정적 영향 ${\bullet}$ 공조기능 장애 ${\bullet}$ 화재시 승강기 승강로 등 수직 샤프트를 통한 연기 전파 혹한기 건물 안팎의 온도차가 40K일 때 높이 600m인 초고층 건물 최상층에 발생하는 연돌효과에 의한 차압은 풍속으로 환산할 때 32m/s에 달한다. 그러므로 초고층 건물 설계시에는 최상층의 풍하측에 설계상의 예상 최대풍속에다 이러한 환산풍속을 더한 고속 풍력이 창문을 밖으로 밀어내는 것으로 보아야 한다. 또한 공조 및 환기시스템에서는 이러한 차압을 고려하지 않으면 고층부에서 환기 성능이 무력화될 수 있다. 다음과 같은 방법들을 이용하여 고층건물의 연돌효과를 효과적으로 줄일 수 있다. 1) 계단실의 연돌효과 저감 방법 계단실에 발생하는 연돌효과에 의한 차압은 계단실에 상승기류를 발생시킨다. 이러한 차압과 상승기류는 계단실 상하부를 개방하면 자연적으로 평형을 이루게 되므로 별도의 제어가 필요 없게 된다. 또한 화재감지기와 연동하여 상하부 외벽의 개구부를 열어두게 되면 피난상황에 따라 문이 여닫힘으로써 발생하는 압력상태의 변화를 고려할 필요가 없게 된다. 2) 승강기 승강로의 연돌효과 승강로의 상하부에 대규모 개구를 두면 대규모의 외기가 도입되어 상승 유동 후 배출되므로 승강로 내부 온도 저하로 연돌효과가 저감되고, 승강로로 유입된 연기는 대규모의 외기에 희석되어 농도가 낮아지고 대부분 외부로 배출된다. 3) 샤프트 복합효과를 이용하는 방법 거실 평면적에 비해 승강기나 계단이 아주 많고 누설틈새 등 개구의 면적 합계가 크면 샤프트들이 서로 복합효과를 이루어 연돌효과에 의한 차압이 줄어든다. 연돌효과 제어용 샤프트를 하나 더 보조적으로 설치함으로써, 보조샤프트에 의해 발생하는 차압으로 거실을 가압 혹은 감압하여 문제가 되는 차압을 어느 정도 상쇄할 수 있다.

  • PDF

A Study on the Hydraulic Properties of Aquifers in Bucheon Area (부천지역의 지하수 대수층의 수리적 특성에 관한 연구)

  • Kim, So-Hee;Lee, Yoon-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.626-633
    • /
    • 2006
  • Bucheon city has been rapidly urbanized and steadily enlarged. Also, the city depends on groundwater as an alternative water resource. The objective of this study is to characterize the hydrogeology in this city including the recharge of groundwater and hydraulic property of an aquifer in order to investigate the chemical characteristics and contamination of groundwater in the Bucheon area. Eleven groundwater wells in the Bucheon area were selected for applying certain hydraulic tests, such as pumping and recovery tests. Theis method and Theis recovery method were used to obtain hydraulic parameters, such as hydraulic conductivity, transmissivity by applying recovery tests. The playground of school and uncovered areas layed a major function of recharging areas. The groundwater well in these areas showed high recharge, transmissivity, and hydraulic conductivity. In a downtown area, groundwaier wells showed low pumping capacity and hydraulic parameters. Groundwater samples were collected from 48 different locations in the Bucheon area and that showed very various chemical composition in groundwater Their electrical conductivity showed various ranges from 70.4 to $1,287{\mu}S/cm$. The composition more significantly affected the groundwater due to the land use and urbanization than that of the aquifer rock type.