Abstract
Bucheon city has been rapidly urbanized and steadily enlarged. Also, the city depends on groundwater as an alternative water resource. The objective of this study is to characterize the hydrogeology in this city including the recharge of groundwater and hydraulic property of an aquifer in order to investigate the chemical characteristics and contamination of groundwater in the Bucheon area. Eleven groundwater wells in the Bucheon area were selected for applying certain hydraulic tests, such as pumping and recovery tests. Theis method and Theis recovery method were used to obtain hydraulic parameters, such as hydraulic conductivity, transmissivity by applying recovery tests. The playground of school and uncovered areas layed a major function of recharging areas. The groundwater well in these areas showed high recharge, transmissivity, and hydraulic conductivity. In a downtown area, groundwaier wells showed low pumping capacity and hydraulic parameters. Groundwater samples were collected from 48 different locations in the Bucheon area and that showed very various chemical composition in groundwater Their electrical conductivity showed various ranges from 70.4 to $1,287{\mu}S/cm$. The composition more significantly affected the groundwater due to the land use and urbanization than that of the aquifer rock type.
본 연구는 부천시를 대상으로 지하수의 함양량, 대수층의 수리학적인 특성, 심도 및 지하수 심도에 따른 수리, 화학적 특성, 지하수의 오염특성을 파악하기 위해 수행되었다. 수리시험의 대상공은 부천지역의 토지이용형태와 도시발달을 고려하여 충적층 2개 지점과 암반층 9개 지점, 총 11개 지점을 선정하여 양수시험과 함께 회복시험을 동시에 실시하였다. 대수층의 투수량계수, 수리전도도 등의 수리상수를 도출하기 위해 양수시험은 충적층은 Theis의 해법에 의해 해석하였으며 암반층은 Theis의 회복해법에 의해 해석하였다. 학교운동장, 녹지공간이 확보된 공원 지역내 양수정은 지하수량이 다른 지역보다 풍부하고, 투수량계수와 수리전도도가 높은 값을 보였는테 이 지역이 강수의 수직침투와 수평이동이 활발하여 도시지역에서 주요 지하수 함양지역임을 뒷받침한다. 도심권의 도로 및 건축물에 의해 포장된 지역 양수정에서는 수리상수 값이 낮아 지하수의 함앙이 어려운 지역으로 관찰되었다. 부천지역 48개 지점에서 채수한 지하수는 심층기반암이 화성암에 기인하여 지하수가 약산성화된 특성을 보였다. 부천시의 지역별 전기전도도는 $70.4{\sim}1,287{\mu}S/cm$의 범위를 보였으며 용해성 광물이나 일부 탄산염의 영향을 받아 대부분의 지역에서 다소 높게 검출되었다.