• Title/Summary/Keyword: 건축물 상태

Search Result 238, Processing Time 0.029 seconds

Integrated Health Monitoring System for Infra-Structure (도시인프라 구조물 건전성 통합 모니터링 시스템)

  • Ju, Seung-Hwan;Seo, Hee-Suk;Lee, Seung-Hwan;Kim, Min-Soo
    • Journal of the Korea Society for Simulation
    • /
    • v.19 no.2
    • /
    • pp.147-155
    • /
    • 2010
  • It often occur to nature disaster that like earthquake, typhoon, etc. around KOREA. A Haiti and Chile also metropolitan area of KOREA occur earthquake. in result, People consider nature disaster. Structures of present age are easily affected by nature disaster. So we are important that warn of dangerous situation as soon as possible. On this study, I introduce Integrated Health Monitoring System for Infra-structure. I develop Structure Health Monitoring System on web-site. Administrator always monitor structure on real-time using internet network. As Administrator using mobile device like PDA, Administrator always monitor structure. As using this system, Damage of nature disaster is minimized and is prevented post damage.

A Study on the adaptability of Carbon monoxide Detector (일산화탄소감지기의 적응성에 관한 연구)

  • Seo, Byung-Keun;Yoon, Myong-O
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.10a
    • /
    • pp.190-194
    • /
    • 2010
  • 화재감지기는 화재시 발생되는 열, 연기, 불꽃, 독성가스등의 다양한 연소생성물을 감시한다. 기술의 발전으로 화재 감지방식과 기능이 다양해지고 있으며, 이에 따라 다양한 방식의 감지기들이 개발되고 있다. 최근 진보된 감지기들은 화재로 발생 이전에서 부터 감지, 비화재보에 대한 방지는 물론 감지기의 상태 오염 감도 등의 다양 정보를 제공함으로써 유사시 신속하고 정확한 대응이 가능하도록 발전되고 있다. 이러한 진보된 감지기는 막대한 피해가 예상되는 장소, 대피하는데 많은 시간이 소요되는 장소에 적용되어 인명 및 재산피해를 절감 시키고 있다. 일산화탄소감지기 또한 진보된 감지기로 화재 초기 가연물이 연소할 때 발생하는 일산화탄소를 감시한다. 일반화재의 경우 화재 초기에 가연물이 서서히 연소시 불완전 연소로 인한 다량의 일산화탄소가 발생되기 때문에 기존 열, 연기, 불꽃감지기에 비해 빠른 반응을 보여 화재를 조기에 감지함으로써 조기 대응으로 인한 피해를 줄일 수 있을 것이다. 본 연구에서는 실물화재시험 자료를 바탕으로 CO감지기의 조기 감시능력을 확인하였다. CO감지기는 화재초기 발생되는 일산화탄소를 감지하므로 대피시간이 많이 필요한 장소(병원 노인요양시설 학교 백화점 등), 침대 폼메트리스 훈소화재 발생장소(호텔침실 기숙사 숙박업소, 병실 등)등에 적응성이 우수할 것으로 분석된다. 최근 설계되는 초고층 건축물 및 주요 시설물 등에서 화재 시뮬레이션과 가상시나리오 유형 분석을 통해 성능위주의 설계가 적용되고 있다. 그만큼 정확하고 신속한 감지가 중요하다 할 수 있다. CO감지기야 말로 그 기대에 가장 부합될 것으로 분석된다.

  • PDF

The Effect of Photoluminescent Exit Path Markings in Evacuation from Buildings (건축물 내에서 축광유도타일이 피난에 미치는 영향)

  • Hur, Man-Sung
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.5 no.3 s.18
    • /
    • pp.67-72
    • /
    • 2005
  • This study is intended to examine the effect of photoluminescent exit path markings in the event of failure of both the power and back-up power to the lighting and illuminated exit sign. To achieve the purpose, the test house was exhibited in Fire EXPO '05. 520 visitors were examined from May 26-29, 2005. The results of this study are as follows; The evacuation from buildings in dark conditions showed that 70% of men and 72% of women were crawled along the wall. Meanwhile, 88% of men and 83% of women were evacuated with ordinary walking in photoluminescent exit path markings. The photoluminescent exit path markings located on public buildings floors will aid in evacuation from buildings in the event of failure of the power to the lightings and illuminated exit signs.

An Investigation into the Actual Condition of Electrical Equipments Installation for the Inspection Method Development Based on IEC 60364 (IEC 60364기반 건축전기설비 점검기법 개발을 위한 현장실태 조사)

  • Jung, Jin-Soo;Han, Woon-Ki;Lee, Han-Sang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.5
    • /
    • pp.36-41
    • /
    • 2009
  • In this paper an Investigation into the actual condition of electrical equipment installation for the inspection method development based on IEC 60364. The analysis objects are the difference between electrical equipments installation in korea & electrical equipments installation based on the IEC 60364. The measurement elements are loop impedance, operating characteristic of circuit breaker and protective conductor continuance. As a result, the korea electrical equipments installation was almost same the TT system but some different of protective conductor continuance. Electrical equipments installed TN-C-S has noting problem about installation but manager dose not understand about IEC 60364.

Study on Fire Resistance of Beams filled with Concrete at Web Through Temperature Analysis and Load-bearing Fire Tests (온도해석과 재하가열시험에 의한 콘크리트 충전 보부재의 내화성능평가에 관한 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.82-88
    • /
    • 2010
  • Major structural elements such as columns and beams are designed to withstand the vertical and horizontal loads. Futhermore, when the structural elements were engulfed with fire the structural stability should be stand without failure. The beams have been developed in aspects of structural stability but an evaluation of fire performance was not done. So the data of fire resistance performance of beams filled with concrete at web on H-section is not known. The purpose of this paper is to analyse the correlation between temperature analysis and fire test with the beams and to show the fire resistance performance with two methods.

A Study on the Maintenance Improvement in Buildings - Focused on the Military Facilities - (건축물 유지관리 개선방안에 관한 연구 - 군시설물을 중심으로 -)

  • Lee Mi-Hye;Kim In-Ho;Kim Young-In;Lee Chan-Shik;Park Tae-Keun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • autumn
    • /
    • pp.311-314
    • /
    • 2001
  • The Military made an investment continuously in facilities construction since the Korea War but, a lot of Military-Facilities Construction have overlooked a long terms plan and detailed examination. The deteriorated facilities that becomes more than about 20 years of the military possession facilities is account about $25\%$ and these are real condition that is not achieving the function properly. Early Deterioration of Military-Facilities bring about waste of national defense cost, environmental pollution and so on. These are not very desirable for nations, societies and environment. Therefore, this study presented maintenance improvement of the Military Facilities for of a long life-cycle of Facilities

  • PDF

Effect of apparent cohesion in unsaturated soils on the ground behavior during underground excavation (불포화토 겉보기 점착력이 지하굴착시 거동에 미치는 영향)

  • Lee, In-Mo;Jung, Jee-Hee;Kim, Kyung-Ryeol;Kim, Do-Hoon;Hyun, Ki-Chang
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.2
    • /
    • pp.117-127
    • /
    • 2010
  • Gound excavation is frequently executed in unsaturated soil conditions. In this paper, the effect of apparent cohesion in unsaturated soils on the ground behavior during underground excavation is studied. The VPPE (Volumetric Pressure Plate Extractor) test, the unsaturated triaxial test and the trap-door test were carried out to figure out how the behavior of soils varies depending on the variation of apparent cohesion. The test results show that the ground behavior is almost identical if the soil is either fully dry or fully saturated. However, if the soil is partially-saturated with the increase of water content, the ground behaves quite differently. In summary, the apparent cohesion in unsaturated soils plays key roles when excavating underground structures.

Development of Pedestrian Evacuation Simulator with Variable Evacuation Speed along with Visibility (가시도에 따른 이동속도 변화 모듈을 적용한 피난 프로그램 개발)

  • Rie, Dong-Ho;Ro, Se-Ho;Kim, Ha-Young;Yoon, Sung-Wook
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2010.04a
    • /
    • pp.120-125
    • /
    • 2010
  • 건축기술의 발달에 따라 건축물은 심층화, 고층화, 대형화 하고, 내부 구조도 복잡화 되고 있으며, 화재시 인명안전에 대한 위험성은 증대 하고 있다. 최근에는 다양한 화재 및 피난 시뮬레이션 프로그램을 이용하여 화재시 건물내 사람들이 안전하게 대피 할 수 있는지를 평가하고 있다. 그러나 현재 사용되고 있는 피난 시뮬레이션 프로그램은 피난자의 종류 별 이동속도를 기준으로 한 안전성 평가는 가능 하지만, 화재시 발생하는 열 과 연기의 확산상태를 고려한 피난자의 이동속도는 적용되지 못하고 있다. 본 연구 에서는 화재 피난 시나리오에 SFPE 방화공학 핸드북의 3-362(연기속의 이동)를 참고하여, 가시도 변화를 적용한 피난자의 이동속도 저하를 구현하여 보다 현실적인 피난 프로그램을 개발하고자 한다.

  • PDF

정주형 플로팅 건축물의 부하계산 기법개발

  • Do, Geun-Yeong;Song, Hwa-Cheol;Won, Jong-Min;Kim, Gu-Sang;Kim, Ju-Yeon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2011.06a
    • /
    • pp.203-205
    • /
    • 2011
  • 부경제적 여유와 함께 사람들의 요구가 다양화 되면서 해양 레저에 대한 관심이 증가하고 있다. 삼면이 바다인 우리나라는 바다를 이용한 해양 레저의 잠재력이 매우 높기 때문에 해양 리조트 개발이 증가할 것으로 예상된다. 그러나 이미 포화상태에 이르렀으며 또한 환경문제를 내포하고 있는 매립에 의한 개발은 상당한 어려움이 따를 것으로 예상된다. 이에 대한 대안으로 플로팅 건축에 의한 개발이 확대될 것으로 기대되지만 플로팅에 의한 해상호텔에 대한 연구는 아직 초보적인 단계에 있으며 이용객의 쾌적성에 직접적인 영향을 미치는 공조 설비 용량을 선정하기 위한 부하계산에 대한 연구는 전무하다고 할 수 있다. 본 연구에서는 육상의 일반적인 호텔과 선박의 공조부하 계산법을 비교 분석함으로써 해상호텔의 공조부하계산방법에 대해 검토한다.

  • PDF

A Basic Study on Data Structure and Process of Point Cloud based on Terrestrial LiDAR for Guideline of Reverse Engineering of Architectural MEP (건축 MEP 역설계 지침을 위한 라이다 기반 포인트 클라우드 데이터 자료 구조 및 프로세스 기초 연구)

  • Kim, Ji-Eun;Park, Sang-Chul;Kang, Tae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.8
    • /
    • pp.5695-5706
    • /
    • 2015
  • Recently adoption of BIM technology for building renovation and remodeling has been increased in construction industry. However most buildings have trouble in 2D drawing-based BIM modeling, because 2D drawings have not been updated real situations continually. Applying reverse engineering, this study analysed the point cloud data structure and the process for guideline of reverse engineering of architectural MEP, and deducted the relating considerations. To active usage of 3D scanning technique in domestic, the objective of this study is to analyze the point cloud data processing from real site with terrestrial LiDAR and the process from data gathering to data acquisition.