Analysis of Characteristics and User's Evaluation for Lightweight Panel in Apartment (공동주택 경량칸막이 벽체구성재 분류별 사용자 평가 및 특성 분석)

  • Park, Hyeon-Ku
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.1
    • /
    • pp.181-191
    • /
    • 2010
  • Lightweight panels are currently used in many ways, such as inner walls of the skyscrapers and residential buildings in Korea. Moreover there has been an increasing of interest in developing construction method and quality improvement as many buildings became higher, because there are more advantages like constructability, finishability, and economic efficiency, etc. than previous heavy weight concrete wall. It is necessary to analyze the characteristics and evaluate the performance of lightweight panels when selecting proper methods and materials to building characteristics and builder's demand. However, there doesn't exist systematic data with a classification of lightweight panels' type and performance. The purpose of this study is to classify domestic lightweight panels by both type of exterior board and construction method, and also to evaluate each performance by surveying user's opinion.

An Experimental Study on Light- Weight Drywall for Improvement of Sound Insulation Performance (건식 경량칸막이 벽체의 차음성능 개선을 위한 실험적 연구)

  • 김태희;신일섭;조창근;송문수;손장열
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1083-1087
    • /
    • 2001
  • The purpose of this study is to obtain the basic data of existing light-weight Drywall through the evaluation and analysis of the light-weight drywall in reverberation chamber and to improve sound insulation performance of drywalls. Sound transmission loss of the total 11 types were analyzed in each frequency a-third octave band and evaluated sound insulation performance for each frequency. From data by analysis and calculation, STC value plotted on STC contour. We found that the improved light-weight drywall specimens ⓑ, ⓒ and ⓖ were satisfied with the domestic standard of sound transmission loss.

  • PDF

A Development of performance criteria tool for lightweight dry wall (건식경량벽체 요구성능 도출 도구 개발에 관한 연구)

  • Ji, Suk-won;Yoon, Sang-chun;Choi, Soo-kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.215-216
    • /
    • 2019
  • The following conclusions were reached through the research on the development of the required performance extraction tools for the application and utilization of various construction methods of lightweght dry wall. 1) Performance required for walls of apartment buildings can be divided into safety, habitation, durability and productivity. Among these, horizontal load resistance, shock resistance, anti-seismic performance, insulation, and acoustic characteristics are the main performance that correspond to dry walls. In addition, safety related to toxic gases and contaminants are required according to recent eco-friendly requirements. 2) To select a wall according to the required performance of an inner wall applied to an apartment, a map tool in the form of 2D matrices was constructed to enable the required performance to be applied, indicating that the wall location and wall material and its differentiating according to the old method.

  • PDF

Criteria of Impact Resistance of Lightweight Wall by the Large Soft Body (건식 경량벽체의 연질 충격체에 의한 내충격성 판정기준에 관한 연구)

  • Kim, Ki Jun;Song, Jung Hyeon;Choi, Soo Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.102-103
    • /
    • 2014
  • Due to the nature of the existing load, the criteria of assessing the intensity of the lightweight wall's impact resistance has been though of as obscure. The current study, therefore, focuses on the standardized assessment of the impact resistance to the force of the large soft body applying to the lightweight wall. The gypsum board wall showed a low level of the maximum residual displacement. It is, however, required to be careful about the selection of the finishing process since the high level of the maximum displacement is likely to cause harm to finishing materials. Unlike the gypsum board, the ALC block wall displayed a considerable rigidity while showing almost no maximum residual displacement. Even with the low level of the maximum displacement due to the stiffness, the ALC block wall is still likely to be affected by the vibration derived from any impact on the surface, which demands a need for additional study. The future experimental study, accordingly, will focus on the impact of the vibration on finishing materials, consequently leading to the accurate prediction of the possibility of potential damage to the lightweight wall caused by the large soft body.

  • PDF

A Review of the Types and Characteristics of Horizontal Load Affecting the Structural Safety of the Lightweight Dry Walls (건식 경량벽체의 구조안전성에 영향을 미치는 수평하중의 종류 및 특성 고찰)

  • Song, Jung-Hyeon;Roh, Yong-Woon;Kin, Ki-Jun;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.43-45
    • /
    • 2013
  • The purpose of this study is to obtain basic data for making performance criteria about the structural safety of lightweight dry wall later by examining types and characteristics of horizontal load acting on the wall. The subjects applying horizontal load to the wall are human and objects. The types of horizontal load are classified as static load and dynamic load depending on the difference of acting time. The magnitude of horizontal load "0.25kN/㎡" defined by KBC 2009 has no significant meaning since it is the unsubstantial nominal load. The result of examining types and characteristics of horizontal load is as follows. (1) Static load by human needs to have more systematic investigation including differences in wall hardness and human weight. (2) Dynamic load by human needs to raise the significance of study result by increasing the number of subjects. (3) Dynamic load by objects needs to accumulate the load specific data for various load subjects considering real situations.

  • PDF

Permissible Criteria of the Stiffness of Lightweight Wall by the Horizontal Static Load (정적 수평하중에 의한 경량벽체의 최대변형량 허용기준에 관한 연구)

  • Song, Jung-Hyeon;Kim, Ki-Jun;Choi, Soo-Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.204-205
    • /
    • 2014
  • Among common test methods of assessing structure safety for existing lightweight walls, the criteria of the quality assessment of the horizontal static load resistance has been considered ambiguous. In the current study, therefore, an experiment was conducted to figure out the standardized assessment criteria of the lightweight wall's horizontal static load resistance. Based on the findings of the experiment with gypsum board and ALC block walls, an acceptable amount of each standard and the variables of the stud wall arising from the appropriate load (1000N) on the wall in a daily life were accounted for, arbitrarily setting the maximum deformation amount below 15mm.

  • PDF

A Study on the Fire Resistance and Sound Insulation Performance of Apartment House Interior Finish Wall Lightweight Drywall (공동주택 세대내 경량벽체 내화 및 차음 성능기준 설정)

  • An, Jae-Hong;Yeo, In-Hwan;Kim, Kyoung-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.2
    • /
    • pp.143-149
    • /
    • 2014
  • Recently, the structure system for apartment buildings in Korea has been changing from wall to post-beam structure. This study examines the fire resistance and sound insulation of light-weight dried wall, a component of post-beam structure. For the fire resistance and sound insulation in Korea, the Compartment wall of apartment house in the case of building regulation has regulations specify the detailed requirement of fire compartment walls in apartment, but do not specify that of interior walls. This study proposes the fire resisting rate of the interior wall into three grades in which the highest grade requires fire resistance of 30 minutes and also proposes the requirement of sound insulation performance into three grades in which the lowest grade requires 35dB.

Load Variation Characteristics about Rope Length of Large Soft Body of Lightweight Wall Impact Resistance test (건식 경량벽체의 내충격성 시험용 연질 충격체의 줄 길이에 따른 하중변동 특성)

  • Kim, Ki Jun;Song, Jung Hyeon;An, Hong Jin;Shin, Yun Ho;Ji, Suk Won;Choi, Soo Kyung
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.182-183
    • /
    • 2014
  • In case of large soft body impact test at the construction site, the test conditions are different from conditions at the laboratory, and the length of rope to hold the impact specimen must be changed. In a previous study, the fact that the size of impact load is varied by the length of rope on the large soft body impact specimen was confirmed. In this study, the length of rope and fall height were set as independent variables to conduct the load analysis test. It was determined that the load fluctuation was occurred depending on the length of rope under the fall height over 100 mm, and it is concluded that the additional setup of fall height to modify the actual impact load size is required when the length of rope is below 2.5 m. In this study, the modified formula to put equal size of impact load regardless of the length of rope was extracted through the experiment.

  • PDF

Study on the Fire Resistance of Light Weight Inorganic Polymer Concrete Panel Wall (Inorganic Polymer Concrete를 이용한 경량패널의 내화특성에 관한 실험적 연구)

  • Hwang, Ji-Soon;Kim, Woo-Jae;Kim, Dae-Hoi;Park, Dong-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.205-206
    • /
    • 2011
  • Inorganic Polymer Concrete, a type of Alkali activated cement and concrete, is known for various excellent performances, especially for better performance in the area of high temperature heat resistance(thermal characteristic) than portland cement concrete.In this study, light weight concrete panel was manufactured using this Inorganic Polymer Concrete and then evaluated for fire resistance with a small-scale heating furnace. Since the result showed excellent fire resistance, it is considered usable for manufacturing fire resistant concrete panel wall.

  • PDF

A Study on the Evaluation of The Load Resistancy of Lightweight Wall against Wall Attachments through Field Tests (현장실험을 통한 건식경량벽체의 부착물에 대한 하중 저항성 평가에 관한 연구)

  • Kim, Tae-Ik;Lee, Ju-Min;Kim, Sang-Heon;Choi, Soo-Kyung;Seo, Chee-ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.183-184
    • /
    • 2015
  • Recent structural approach of the House of Commons has been an increase in demand for dry wall light due to a change in load bearing composite structure of a flat plate type structure under the name of long-life housing, attach the attachment to the wall as the needs of the residents of reserved space increases things that are on the rise. However, depending on the strength of collapse accidents is shown wall and recent wall deposits are required, a load resistance evaluation method of the deposit of the need is the situation. Therefore, in this study, for the evaluation of the evaluation of dry lightweight wall as widely used gypsum board and ALC lightweight wall of two types of laboratory the wall through the previous studies to be installed in direct co-housing to the target and field experiments I want to evaluate the different points.