• Title/Summary/Keyword: 개폐

Search Result 1,128, Processing Time 0.038 seconds

The Effects of Improvement in Clay with High Moisture Contents Using the Filter Type Vacuum Consolidation Method (필터형 진공압밀공법을 이용한 고함수비 점토지반의 개량효과)

  • Oh, Sewook
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.9
    • /
    • pp.55-60
    • /
    • 2010
  • This study are carried out to an lab model tests to develop a construction method that solidifies high-water content cohesive soil by using filter type drain and vacuum pressure, and that stabilizes the ground by accelerating horizontal drain at incline or in tunnel. The calibration chamber was designed within length of 1.5m and height of 50cm, and a drainage hole for preconsolidation, a switchgear and a piezometer were installed at the bottom part of the chamber. Also, a settlement gage was installed at the top part so that it can measure the settlement by time. The calibration ground basis was made in a form of thin layer from kaolinite and bentonite in 9:1 ratio stirred at 130% water content condition. A filter type drain was installed at chamber center and a vacuum pressure of 0.8MPa was applied through a hose linked to the cap at the top part, then, the settlement was measured in every 1 hour interval. After experiment, the moisture contents were measured by position, then, verified the increase of solidity of the ground through a triaxial compression test on undisturbed profile. After 11 days from the effective date, it was observed that the settlement decreased by maximum 35mm and the water content ratio was reduced by 38% at most while the solidity of the ground increased by 5~8 times greater than before preconsolidation.

MAC Schemes for Best Effort Service in Wireless MAN: Design and Performance Analysis (무선 MAN에서 Best Effort 서비스를 위한 MAC 방식의 설계 및 성능 분석)

  • Park, Jin-Kyung;Shin, Woo-Cheol;Ha, Jun;Choi, Cheon-Won
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.11 s.353
    • /
    • pp.128-140
    • /
    • 2006
  • In the IEEE 802.16 Wireless MAN standard specifies the air interface of fixed point-to-multipoint broadband wireless access systems providing multiple services. Among the service classes supported between the base station and subscriber stations in the wireless MAN, the best effort service class is ranked on the lowest position in priority and is assisted by a MAC scheme based on reservation ALOHA. The wireless MAN standard, however, does not reveal every detail of the MAC scheme but only describes the skeleton of the MAC scheme. Focusing on the amount of resource that a subscriber demands by a request and the amount of resource that the base grants to a request we thus present a number of resource demand rules and resource grant rules. Also, we construct a candidate MAC scheme by implanting a pair of resource demand and grant rules into the skeleton of the MAC scheme. Meanwhile a difficult situation for the best effort service is expected wherein only scarce resource is available after most of the resource is already preempted by other services. Perceiving such a situation, we evaluate the throughput and delay performance of each candidate MAC scheme. Especially we develop an analytical method to approximately calculate the throughput in the saturated environment. From the numerical results, we observe that the candidate MAC scheme which adopts the non-gated exhaustive demand rule paired with the full grant rule attains superior performance at the expense of the fairness.

A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards (KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.63-72
    • /
    • 2017
  • This study fabricated a low-voltage 10 circuit distribution board based on the KEMC (Korea Electrical Manufacturers Cooperative) 2102-610 standard and performed a characteristics assessment of the developed 10 circuit distribution board to secure product stability. The developed 10 circuit distribution board is designed to have the characteristics of insulation materials, as well as resistance to corrosion ultraviolet radiation and mechanical impact. The developed distribution board is fabricated to have an appropriate protection class of enclosure, electric shock prevention and protection circuits, switchgear and its components, internal electrical circuits and connectors, external conduct terminal, insulation characteristics, temperature rise test, heat resistance, etc. The developed 10 circuit distribution board consists of a single phase circuit and 3-phase circuits. It is possible to measure in real time the leakage current generated from the load distribution line by installing a sensor module at the load side of each of the branched switchgears. In addition, it is possible to increase a circuit according to the use and purpose of the load and to also manage and check the load in real time. Temperature rise tests were performed on the developed 10 circuit distribution board at 18 places including the inlet connection, main circuit and distribution circuit bus bars and bus bar supports, etc. The highest temperature of $65.3^{\circ}C$ was measured at the R-Phase of the connection of the MCCB power supply for the branch circuit bus bar and a temperature rise of $61.6^{\circ}C$ was measured at the T-Phase of the load side. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state.

Pressure Control of Brake Circuit with Piezoelectric-hydraulic Pump Using Pressurization/Depressurization Characteristics (압전유압펌프가 적용된 브레이크 회로의 가감압 특성을 이용한 압력 제어)

  • Hwang, Yong-Ha;Hwang, Jai-Hyuk;Bae, Jae-Sung;Kwon, Jun-Yong
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.3
    • /
    • pp.8-15
    • /
    • 2017
  • In this paper, an equivalent brake hydraulic circuit with a piezoelectric hydraulic pump was constructed, and load pressure control for better pressurization/depressurization characteristics was conducted. To understand pressurization/depressurization characteristics of the equivalent hydraulic circuit, the relation between the load pressure and the input voltage was revealed experimentally. Experiments were also conducted to observe effect of the solenoid valve on depressurization characteristics. In the pressurization experiment, it was validated that transient response time required to achieve desired load pressure may be reduced through voltage control to change pressurization gradient. By applying the valve on/off time control and voltage control, it was also possible to reduce response time in the depressurization process. Therefore, transient response time may be improved within 10ms for pressurization and within 30 ms for depressurization using the control technique suggested in this study. The load pressure control method proposed in this study is useful for controlling load pressure of a hydraulic brake system with the piezoelectric hydraulic pump.

Study on the Current Safety Management Status and Safety Improvement of Gas Valve (가스밸브의 안전관리 현황 및 안전성 향상 연구 (모니터링을 중심으로))

  • Choe, Byeong-Gyu;Cha, Min-Chang;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.57-63
    • /
    • 2016
  • Though a valve is a very important part in a system to control properly, it has potential failure caused by gap from valve stem to ball connection, and abrasion, crack, fixation causing operational trouble and accidents. 64% of the valve failure in the real case was the failure of airtightness and most accidents of leakage and explosion were occurred while fixing the failure. While there are no proper safety manual, maintenance procedure and regulation for industrial valves excluding safety valve, safety management for the valves is left to the discretion of the maintenance company. Strict maintenance that removes hazards and emergency response procedure are required to prevent and reduce the loss of accident. This study suggests safety enhancement measures through valve monitoring by investigating the status of use of valve and current maintenance. Enhancement of gas safety management can be acquired by a monitoring system that provides diagnosis for valve status, monitoring real-time gas leakage, management of entire cycle lifetime that can reduce maintenance cost.

A Numerical Study on Pressure Fluctuation and Air Exchange Volume of Door Opening and Closing Speeds in Negative Pressure Isolation Room (음압격리병실에서의 병실 문의 개폐속도에 따른 실간 압력변동 및 공기교환량에 대한 해석적 연구)

  • Kim, Jun Young;Hong, Jin Kwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.1
    • /
    • pp.51-58
    • /
    • 2018
  • Purpose: In this study, through the comparison of the pressure fluctuation and air exchange volume in negative isolation room according to the type of the door and door opening/closing speeds, which is one of the main factors causing the cross contamination of the negative pressure isolation room, establishes standard operating procedures to prevent cross contamination in high risk infectious diseases and isolation room design. Methods: In this study, the air flow each of the room is analyzed using ANASYS CFX CODE for flow analysis. In addition, the grid configuration of the door is constructed by applying Immersed Solid Methods. Results: The pressure fluctuation due to the opening and closing of the hinged door was very large when the moment of the hinged door opened and closed. Especially, at the moment when the door is closed, a pressure reversal phenomenon occurs in which the pressure in the isolation room is larger than the pressure in the anteroom. On the other hand, the pressure fluctuation due to the opening and closing of the sliding door appeared only when the door was closed, but the pressure reversal phenomenon not occurred at the moment when the sliding door was closed, unlike the hinged door. As the opening and closing speed of the hinged door increases, the air exchange volume is increased. However, as the opening and closing speed of the sliding door is decreased, the air exchange volume is increased. Implications: According to the results of this study, it can be concluded that the pressure fluctuation due to the opening and closing of the hinged door is greater than the pressure fluctuation due to the opening and closing of the sliding door. In addition, it can be confirmed that the pressure reversal phenomenon, which may cause to reduce the containment effect in negative pressure isolation room, is caused by the closing of the hinged door. Therefore, it is recommended to install a sliding door to maintain a stable differential pressure in the negative isolation room. Also, as the opening and closing speed of the hinged door is slower and the opening and closing speed of the sliding door is faster, the possibility of cross contamination of the room can be reduced. It is therefore necessary to establish standard operating procedures for negative isolation room for door opening and closing speeds.

Estimation of Modification Factor for Scale Effect of the Front of Flood Wave Propagation (홍수파 선단의 축척효과에 대한 보정계수 산정)

  • Jeong, Seok-il;Kim, Soo young;Lee, Seung Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.39-44
    • /
    • 2016
  • Recently, there has been increasing concern regarding the collapse of hydraulic structures due to abnormal climate conditions. Therefore, numerous studies of the collapse of hydraulic structures have been carried out. In particular, the velocity of the propagation of a flood wave-front is important for predicting the inundation safety and establishing an EAP (Emergency Action Plan). Although many hydraulic tests have been conducted for precise predictions of a flood wave-front, the scale effect from downsizing has not considered. In this study, the relationships between surface tension and the concentration of surfactant, between surface tension and the velocity of flood wave propagation, and between surface tension and the Weber Number were derived through hydraulic tests using a surfactant and image analysis equipment. Based on these relations, the modification factor for the scale effect of the front of flood wave propagation was suggested. The results highlight the necessity of a modification factor when the Weber Number is lower than 12.2, but the scale effect can be ignored when the Weber Number over 12.2.

Mesozooplankton Community Dynamics in Watan Stream, Yeonggwang, Korea (영광 와탄천의 중형동물플랑크톤 군집동태)

  • Lee, Dong-Ju;Kim, Say-Wa;Lee, Won-Choel
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.4
    • /
    • pp.425-432
    • /
    • 2009
  • Mesozooplankton dynamics were studied in Watan stream which flows into the Yellow Sea in Yeonggwang, Korea. Samples were collected at eight stations bimonthly during April 2006~February 2007. Mesozooplankton community was consisted of 45 taxa (8 cladocerans and 29 cope-pods). The abundance varied between the highest one ($31{\sim}127,587\;indiv.m^{-3}$) in October, and the lowest ($12{\sim}233\;indiv.m^-3$) in December. Diversity index showed to be the highest value in July (0.671) and the lowest one in August (0.368). A euryhaline species, Acartia hongi was dominant in brackish water stations (the highest abundance at $13.4^{\circ}C$ and 14.1 psu). In freshwater stations of the upstream, two cladoceran species of Polyphemus pediculus and Moina weismani occurred in high abundance in August. Dominant taxa of copepod were clustered to two or three groups mainly due to the difference of salinity gradients. Spatial distribution of mesozooplankton revealed to be determined by salinity gradients which were affected by opening and closing of the artificial dam in Watan stream.

Development of a Pressure Core Sampler with Built-in Data Logging System (데이터 기록 장치가 내장된 PCS (Pressure Core Sampler)의 개발)

  • Kim, Sang Il;Cho, Young Hee;Ki, Jung Seck;Kim, Dong Wook;Lee, Kye Kwang;Kim, Hae Jin;Choi, Kook Jin
    • The Journal of Engineering Geology
    • /
    • v.24 no.3
    • /
    • pp.423-429
    • /
    • 2014
  • Development of a reservoir pressure core sampler (PCS) with a built-in data logging system (DLS) for recording real-time temperature and pressure observations is critical in domestic hydrocarbon production to accurately measure and monitor reserves of shale gas, coalbed methane, and gas-hydrate. Another purpose of this new technology is to minimize the loss of gas from the core as the drill core is collected. This is accomplished by maintaining the pressure of the sample from the moment the drill core is obtained at depth, thus allowing an accurate analysis of shale gas, coalbed methane gas, and gashydrate within the core. Currently, the United States and European countries have monopolized the development and marketability of PCS technologies. We are thus developing a reservoir PCS by analyzing the operating principle and mechanisms of the existing PCS, and by conducting tests on the existing PCS. We further aim to develop a PCS with a maximum operating pressure of 100 bar, a maximum operating temperature of $-20^{\circ}C$ to $40^{\circ}C$, and a pressure loss rate of 10%.

Improvement of Katsuobushi smoking machine for the reduction of benzo(a)pyrene (가쓰오부시 훈연기 개선 및 벤조피렌 저감화)

  • Hong, Ju Hee;Hwang, Sang Min;Lee, Seung Ju
    • Korean Journal of Food Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.162-167
    • /
    • 2017
  • A Katsuobushi smoking machine was developed and evaluated to determine its benzo(a)pyrene reducing effect. The machine was equipped with two heaters for smoking and chamber heating. The smoke-generating system was equipped with a cadmium sulfide (CdS) smoke sensor, an on/off controller, and a rotating feeder with a smoke inlet. Raw bonito was steamed and then smoked under three smoke levels. After smoking at $45^{\circ}C$ for 108 h, the benzo(a)pyrene concentrations were 5.87, 7.83, and $11.41{\mu}g/kg$ at the low, middle, and high smoke levels, respectively. The benzo(a)pyrene concentrations after low-level smoking at 45, 65, and $85^{\circ}C$ for 108 h were 5.87, 4.82, and $3.27{\mu}g/kg$, respectively. Accordingly, the optimal conditions for benzo(a)pyrene reduction were a lower smoke level and higher smoking temperature. These optimal smoking conditions can be implemented with the newly developed machine, but is not possible using a conventional Katsuobushi smoking machine.